Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND ,= _-' - PROPOSED CONTOUR AUG 2 4 20® 11+ PROPOSED SPOT GRADE T13M = EL. 1 I .7 (NAVD88) 98 -- EXISTING CONTOUR I/ TOP OF LANDING HEALTH DE 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE 125.68' is TEST PIT PROP. 5FT. I / 9.6 SOIL REMOVAL ;�--- rV 9. �co Q � 11. p'? VI/ EI-iST sFR� '� �qc �cF i y 9.8 9 I C / 9.4 \ 9.3 �\ 10.5 1�---,—�� 8.7 LOT 13 AREA = 24829 sf+— 7. 1 \ & 5.2 9 SCALE 1"=30' Permit valid for REPAIR Of SE►IIc S\"I!Nl 'f1NLV, due to State .Htd Lu,al septic rAt,:ui. cs. Board of health review sad approval ,,-quirrd .nr any future additionhenm ,Iions,.,i: ration, to sewage facilitiesandlerstracm.es/dwc ..X. Varmoul6Heahl, Departmeot APPROVFI) Name I hale GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. B. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING ONSTRUCTION. 0. EXISTING LEACHING TO BE CRUSHED, PUMPED AND REMOVED. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY t NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING !4. ALL PIPE TO BE 4" SCH 40 O 1/8-/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER r. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING ,, 7. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL 6.90 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. WEST YARMOUTH ROUTE 28 3/<f :4,V. LOCUS 65 HERITAGE DR. 4 % 4t R0, LOCUS MAP LOCUS INFORMATION PLAN REF: 150/22 TITLE REF: D1069889 PARCEL ID: MAP 017 PAR. 026 FLOOD ZONE: AE "EL 11" COMMUNITY PANEL: 25001CO588J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 65 HERITAGE DRIVE WEST YARMOUTH, MA PREPARED FOR JOHN PERRONE AUGUST 14, 2020 tN OF MASggch V OF S RUMBA �N DARIN o No t! //,No. 1140 t4 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle50gmail. com www.meyerandsons.com SHEET 1 OF 2 967 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:6.87 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D-BOX PERIMETER OF THE SAS. PROPOSED S.A-S. T.O.F. EL.=13.2 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER t� OF yes OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. F.G. EL.=1 F.G. EL.=11.0t F.G. EL: 10.0f F.G. EL: 9.BMAX.) ARREN M. 1140 9' MIN COVER/ L - 25' 36' MAX COVER L - 22' O S-IX (MIN.) EL 10.20 O S-1X (MIN.) L - 10'(MA7O O S-ix (MIN.) INSTALL TWO INSPECTION PORTS (MIN.) 4'SCH40 PVC 4'SCH40 PVC 40SCH40 PVC AUG 2 4 2020 fo 14 INV.=9.18 48' LIQUID INV.=8.93 3.3" TO INVERT HEALTH DEPT ��� Le1Et � PRDOBOOXED GAS INV.=8.30 4 ROWS OF 8 UNITS AT 4.0'/UNIT a 32.0'/ROW JELA& IW.=8.50 DB-5 INV.= 7.88 SOIL ABSORPTION SYSTEM (PROFILE) PROP 1,500 GALLON SEPTIC TANK 48" RESTORE VEGETATIVE COVER EXIST. OUTLET BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS NOTES: BREAKOUT=TOP ELEV.=8.27 34" 1 CONTRACTOR SHALL VERIFY ALL EXISTING INV. ELEV.= 7.88 PIPE INVERTS PRIOR TO CONSTRUCTION 2) D-BOX SHALL BE SET LEVEL AND TRUE TO / BOTTOM ELEV.= 7.60 EXISTING SUITABLE MATERIAL GRADE ON A MECHANICALLY COMPACTED SIX t/ INCH CRUSHED STONE BASE, AS SPECIFIED IN T IN. ABOVE BOTTOM OF EXCAVATION OR G.W. 2.83' EFFECTIVE WIDTH 4 x 2.83' 11.32 , r r 310 CMR 15.221(2) (5.27' PROVIDED) USE 4 ROWS OF 8 INFILTRATOR QUICK 4 PLUS PROFILE 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK GROUNDWATER EL.=2.37 = STD LP (3.3" INVERT) UNITS -NO STONE WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED OR UNDERSIZED. 48 4) INSTALL INLET &OUTLET TEES W/ SEPTIC SYSTEM PROFILE l GAS BAFFLE AS REQUIRED TYPICAL SECTION N.LS• 8„ SECTION I END CAP DESIGN CRITERIA **NO PROPOSED INCREASE IN FLOW** SOIL LOG 7 NUMBER OF BEDROOMS: 4 BEDROOM DWELLING/4 BEDROOM DESIGN DATE: JULY 21, 2020 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: MALLORY LANGLER, YARMOUTH HEALTH INFILTRATOR QUICK 4 PLUS STD LP (3.3" INVERT) UNITS DAILY FLOW: 440 G.P.D. DESIGN FLOW: 440 G.P.D. D". TP-1 Depth GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) 9.50 o• MODEL QUICK4 LP PROPOSED SEPTIC TANK: 440gpd x 200% = 880 gpd (USE EXIST. 1,000G TANK) 10VR 4 1 LENGTH 48" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT 842 13• EFFECTIVE LENGTH 48" TO CHANGE WITHOUT NOTICE PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (440) = 594.59 S.F. sum m DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. 1`rnR / 3 SIDE WALL HEIGHT .3" 74 OVERALL HEIGHT 8" DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) 7'00 1 30" OVERALL WIDTH 34" PRIMARY S.A.S. USE 4 ROWS OF 8 — INFILTRATOR QUICK 4 STD LP (3.3" INVERTi ME a/SW CAPACITY PROPOSED SEPTIC SYSTEM SITE PLAN .UNITS WITH NO STONE -D.so 120" BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 32 UNITS x 4.00 LF x 4.73 SF/LF = 605.44 SF PERC RATE <2 MIN/IN. (-Cl- HORIZON) 65 HERITAGE DRIVE, WEST YARMOUTH, MA GROWW ATFR OBSOM AT 100' EL 1.17 Prepared for: John Perrone TOTAL AREA = 605.44 SF W°L MN-29 ZONE: A DESIGN FLOW PROVIDED: 0.74GPD/SF(605.44SF) = 448.02 GPD > 440 GPD req'd LLva, 7.5 AOA1S1Lom 1.2 AMPMU GRouNOwaER EL 2.37 Design and Site Plan by: MEYER B SONS, INC. SCALE NTS DRAWN D.M.M. • I, Darren M. Meyer, RS., CSE, hereby osrlify that I am curve* approved by MADEP pursuant to 310 CMR 15.017 PO BOX981 DATE: CHECKED SHEEP NO. to conduct =0 evaluadone and that the above analysis has been performed by me consistent with the EASTSANDWICH, MA 02537 requirements of 310 CMR 15.017. 1 further certxy that I have possed Me Soil Evol. Exam in October, IM. 50a362-2922 08/14/20 D.M.M. 2 of 2