Loading...
HomeMy WebLinkAbout24-A041 3 Covey Drive Approved.L TOWN OF YARMOUTH 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 124APR 1549:00 REC ��� Telephone (508) 398-2231 Ext. 1292^-Fax (508) 398-0836 NG'S HIGHWAY HISTORIC DISTRICT COMMITTEE MAR 2 2 2024 APPLICATION FOR rAHIVIUUI I-, CERTIFICATE OF APPROPRIATENESS OLD IN 'S g I HWAY a for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMIT 4 CopieS OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Categories That Apply; Indicate type of Building: Commercial X Residential 1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage Shed X Solar Panels Other: 2) Exterior Painting: Siding Shutters Doors _Trim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work: 3 Covey Dr Yarmouth MA 02675 Map/Lot # 136-35 Owner(s): nale Genhagan Phone #:919-381-7222 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 3 Covey Dr Yarmouth MA 02675 Year built: 1985 Email: Preferred notification method: Phone X Email Agent/contractor: Sunrun Installation Services 1 Stephen A Kelly Phone # 978-793-7881 Mailing Address: 695 Myles Standish Blvd Taunton MA 02780 Email: eastmaapermits(Q7sunrun.com Preferred notification method: Phone X Email Description of Proposed Work: Installation of an interconnected rooftop solar system total of 22 panels. Front of the home will have 9 panels in symmetrical design with 3 rows of 3 panels. Panels on front of the home will be visible from Covey Dr and Setucket Rd. There will be 13 panels on the rear of them which is blocked by foliage and trees Signed (Owner or agent): Date: 3121 /2024 r Ownerlcontractorlagent is aware that a permit is required Wom the Building Department. (Check other departments. also.) D If application is approved, approval is subject to a 1l}-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later - All new construction will be subject �spection by OKH OKH-approved plans MUST be available on -site for framing & final inspections. Rcvd Date: Amount go. W Cash1CK 0 1 OW/1 Rcvd by: 1,151 46 Days: �' 7 Date Signed: 0• L Approved Approved with Modifications Denied Reason for Denial. Signed. DIED APR 2 2 2024 tAIRMUUi t. APPLICATION #: A-AO41 J TOWN OF YARMOUTH N It OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 Telephone (508) 398-2231 Ext.1292 Fax (508) 398-0836 STATEMENT OF UNDERSTANDING CHANGES TO AN OLD KING'S HIGHWAY APPROVED PLAN As property owner/contractor/agent for construction at 4 cwe�'l nrivz Map/Lot t CIA # 2 f . 41 Approval Date: ��A:Z2=L I certify that I understand the following requirements regarding any changes that may be required for this project: In accordance with paragraph 2(a) of section 1.03(General Procedures) of the OKH 972 CMR Rules and Regulations: Only minor changes may be approved by the Committee without the filing of a new application and a new hearing. Minor changes Include alterations that can be done without a detrimental impact on the overall appearance of the project such as altering a single window or door change or a minor change of colors. All minor changes by amendment will require the local Committee's or its designee's approval. All changes to previously OKH approved plans require notification to and approval from the local OKH Committee. Change requests must be submitted to the Committee in writing on the appropriate request form, which may be obtained from the OKH office. All change approvals must be obtained before incorporating the change Into the project. If the change has been implemented prior to receipt of OKH approval, a Minor Change approval or Certificate of Appropriateness application for the revised plans is still required and will result in a doubled filing fee for the appropriate category of work. Failure to comply with the above statements will result in the Building Department issuing a stop -work order or delaying the issuance of an Occupancy Permit or final inspection approval. I have read and understand the above statements. Date: Signed FA�OPWVE"� 1 45, ' PR 2 2 NZ4 Signed Y A 1vi0 T H 10KH COMMITTEEWpkation Forms%Statement of Understanding 2015 doex (Chairman, Old King's Highway Committee) Updated 12/2015 Telephaae (509) 398.2231 Ext. 1292 Fox (508) 3984336 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 45-DAY TIMEFRAME WAIVER Application #: 2Lf- Acxf Project Address: 3 Covey Dr Application Received Date: ✓� �� 45 Day Decision Deadline: ■ FCEIVE M - 2 2 202z IANe, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: Rooftop Solar 22 Panels Date: 3/21/2024 Signed: Owner Owner Co ractor/Age TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 2023 MEETING SCHEDULE Y APPRMED APR 2 2 2024 �ARmUU r h e'Iftirir, . ?4,AD41 8.2018 TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS' LIST Applicant's (Owner) Name: Dale Geohagan Property Address/Location: 3 Covey Dr Yarmouth Port MA 02675. Hearing Date: 4/2>1 Notices must be sent to the applicant and abutters (including owners of land on any public or private street or way) whose property directly abuts or is across the street from the applicant. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: wwaw .yarmouth.ma. us Applicant Information: Abutter Information: MAR 222 a � AhN jti r WAY OLD KING 91 �V �I APP APR 2 2 2024 , ARNIUU l i' Map Number 136 35 Lot Number 144 9 36 7 1 Lk .� 136 136 69 136 8 136 34 Y Application #: , TOWN OF YARMOUTH p d 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451 ,3 1361 371 1 1 MILNE SUSAN TR SUSAN MILNE TRUST 8285 SANDPINE CIR PORT ST LUCIE , FL 34952 1361 361 1 ! SODERBERG DANA J SODERBERG LEANN E 7 COVEY DR YARMOUTH PORT, MA 02675-2255 1361 351 1 1 LESTER TASHANE GEOHAGAN DALE 3 COVEY DR, YARMOUTH PORT, MA 02675 1361 341 1 1 BOUCHER ROBERT K CIO BOUCHER ROBERT K TR 218 SETUCKET RD YARMOUTH PORT, MA 02675-2258 1441 591 ! 1 TOWN OF YARMOUTH 1146 ROUTE 28 SOUTH YARMOUTH. MA 02664- 463 1361 681 1 1 COOK DALE A COOK LELIBETH C 1 UNCLE JIMMYS LN, YARMOUTH PORT, MA 02675 Please use this signature to certify this list of properties directly abutting and across the street from the parcel located at: 3 Covey Dr., Yarmouth Port, MA 02675 Assessors JIAap 136, Lot 35 Andy MagKado, Director of Assessing April 9, 20024 RECEIV� APR Q � 2024 OLD K!!UG S HIGHWAY APPROVED APR 2 2 2024 YARMOU i h A�'AN I a 5 0 0 9 0 W4 t M m Jc ran �p�LINS QpNV POPD �....y MY5 0 �l 3� n $ Nx LA RECEIVED MAR 2 2 2024 rAHIVIUU i r, OLD KING'S HIGHWAY ca -. NO rl4 O0 {'V N u Ln i LOLD�PVR2 2 2024GSOUGlj-fWAY C r n I;CF-IVEI) MAR 2 2 2024 Y ARiV Ou-i r. OLD KING'S HIGHWAY Home is on ft writer of Setudcet Rd and Covey Or. Proposes solar system consists of 22 panels. Front of the home roof plane will have 9 panels in a symmetrical design 3 rows of 3. The rear of the home will have a total of 13 panels. Panels on The front of the home are visible from both Covey Or and from Setuckat Rd. The rear of the home Is mostly hidden behind Veal and foliage. A iti PRr4 M ED APR 2 2 2024 - rr R CrrlvF-o,.. I MAR 2 2 2024 YYARJ'YLOU I r' OLD y 4, IIINAY - Below is view from Sakickat Rd headino towards C&mv m thm rinhi APPROVED APR 2 2 2024 fARMOUTH nr m iziKintic Wif'-WWAY Below Is on S&tLpckei Rd Heading loweAs Covey Dr on the left. House Is hidden behind foliage 2 Lf- � Q ) Fi-ECTIVE6 MAR 2 2 2024 I i AMv1UU i rN OLKING' HIGHWAY App0Vt APR 2 2 202 (ARMvu I n SHEETINDEX LEGEND SCOPE OF WORK GENERAL NOTES -ALL VKORK SMALL COMPLY VNTH MA OTH ED. CMR 780(20151RCABCIEBCI 7-10 ASCE S 2015 NDS 2023 NEC AM 2023 MA ELECTRICAL CODE S27 CMR 12.00 2023 TIFPA 70 MATH MA AMENDMENTS). MUNWAL CODE. AND ALL MANUFACTURERS LISTINGS AND INSTALLATION INSTRUCTIONS. , PHOTOVOLTAIC SYSTEM VNLL COMPLY VKTTH NEC 2023. • ELECTRICAL SYSTEM GROUNDING VNLL COMPLY KITH NEC 2023. , PHOTOVOLTAIC $Y$IUN EM IS GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THEINVERTER. SYSTEM COMPLIES NTH 6N.35. , MODULES CONFORM TO AND ARE LISTED UNDER UL $1730, • INVERTER CONFORMS TO AND IS LISTED UNDER UL 174I. PAGE DESCRIPTION SERVICE ENTRANCE ® MAIN PANEL SP SUBfhNEL ® ,$Y$TEM $IZE IIB00NOC BOOR'VAC , MODULES (22) HAMMiA O-CELLS O.PEAK DUO BLH M1.410•I7900 • INVERTERS: (U SOLAREDGE TECHNOLOGIES SE6000+UggN • RACKING RL UNIVERSAL SPEEDSEAL TRACK ON r.OMP SEE DETAIL SNR4X-M36 PV•10 COVER SHEET W--2.0 SITE PLAN nLi 0 777 PV4.0 ELECTRICAL ��'0 SIGN' GE _ LC PVLOADCENTER , RACKING CONFORMS TO AND IS LISTED )RIDER LPL 2703. • SNVNRAG( RACKING SYSTEMS. IN COMBNAnON N1TH TYPE I. OR TYPE II _ _ MODULES ARE CLASS A FIRE RATED. BUNKUM METER •RPID 3"UTDO MI REOUREMENTS MET NAEN INVERTERS AND ALL CONDUCTORS ARE VATHIN ARRAY BOUNDARIES PER NEC 890.12(l). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER NO. III D). DEDICATE. —..TER • ARRAY DC CONDUCTORS ARE SIZED FOR OERATED CURRENT. • 12,18AMP8MODULE SHORTCIROIAT CURRENT. • 1523 AMPS DERATED SHORT CIRCUIT CURRENT [0110.8IA) 6690.8I ft INV INVERTER(S) F • PV INSTALLATION COMPLIESVNTH THE NEC 2021 ARTICLE 000.12NBH2N21 CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 60 VOLTS IMTHIN 30 SECOND OF A RAPID $HuTOOV+N INT1AT10N AC DISCONNECTLSI DC DISCONNECTLSI CB 10 COMBINER - r1111111 EQUIPMENT L J SHONN AS DASHED CHIMNEY ATTIC VENT O FLUSH ATTIC VENT -ABBREVIATIONS f ...1<.M sunrun 6 ram +ri .a.mi n�rt PVC PIPE VICINITY MAP s180120`p'�� p' wma o VENT • METAL PIPE VENT m T»VENT L"`��•• CUSTOMER RESIDE DALE GEOHAGAN IMP eewr no..ac nnw ,,. 4 {1 T - 4 �i m meal �` area w eW i9t.ICEAvg SATELLITE DISH Y '-' 4 f� * ._ 3 COVEY DR. YARMOUNH. MA �n_ rEw N 02675 M. Wfrolu.[ FIRE SETBACKS Tti_ t HARD$CAPE PL— PROPERTY LINE SOLAR LFJI Es SNR MOUNT SNR MOUNT 6 SKIRT '+ 9 �. k, # ix \w' ��� 1 T • % I � y r wv i ' .. • q ' - 9 •' s .- REV NAME PAU COMMENTS TEL (910) ARM4 01Q Y hPN hRi4001]60006X p1CMw 116` PR UMBER 713R-003OEOH w .>o wo ewu c uv'Io+.rtoawowKc DESIGNER 1a1s156669A.i1 GABRIEL MAHCRO SHEJA SHEET COVER SHEET n *wwaaaans �„x REV A 3117f102A PAGE PV-1.0 iPane+rt .oA x-AN I NITS 2Ut?ML41 SIM PLAN .SCALE - wir - v-v . 9 (M) ARRAY ,E FENCE ROOFPAnlWAY5 Y TYP) FIRE F (3. TYP) ,E -.N. ARRAY AR-M ARRAY TRUE 'AA6 PYAREA PITCH AZIM AMM ISCIFT) 1 91' 190.2 1 T%4)1 ,F7 34 271' ;U.8 -E-FENC NOTES: R- SIDENCE DOES HOT CONTAIN ACTIVE FIRE SPRINKLERS ARRAY DETANA: TOTAL ROOF SURFACE AREA IM SOFT ' TAL PV ARRAY AREA: 46S 0 50 FT • PERCENTAGE PV COVERAGE .ri)TAL - ARRAY AREAfT*TAL ROOF "FACE AREA- I OC - 35 3% a E D APPR (E) DRIVE WAY R41 ROOF PATHWAYS .3, TYP) SE 7 \---- , -9 APR 2 2 2024 �ARMOU rh ROOF INFO FRAMING INFO Name TYPa Hdy1t Typo AR-01 COMPSHINOLE-RLU I -Sorry 2X8 RAFTERS AR-02 COMPSHtNGLE-RLU 14AM MRAFTERS D7 -AR-0T -SCALE- Im— T'-0- AZIM:77' PITCH: 3W RECEIVED j t MAR 2 2 2064 f Anivivu 1 i . OLD KING'S HIGHWAY SP^ SPeAY D-W RL UNIVERSAL SPEEOSM TRACK ON IT r ie. COMP SEE DETAIL SNR-DC-MA36 RL UNIVERSAL. SPEEDSEAL TRACK ON COMP SEE DETAIL SNR4)C-00636 02-AR-02•SCALE:Iff- V-0- A;IM:257 PITCH 3A' ELD 222024 vlOU7h ATTACHMENT INFORMATION Max Leal ftm Mo La ndb Oc spaaaq OYeftN V - 1 7-1- V-r 2.1• V ItK1A STRUCTURAL NOTES: LOAD: 3PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W IF INSTALLATION. ;T. . IF ARRAY (EXCLUDING SKIRT) IS WTHN 17 BOUNDARY REGIONOF ANY ROOF PLANE EDGES (EXCEPT VALLEYS). THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCEDIMTHN THE 17 BOUNDARY REGION ONLY AS EMBEDMENT FOLLOWS * ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY $q% .. ALLOWABLE OVERHANG INDICATED ON PLANS TO BE l5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. Swdn6 aarhrg1 cA eo+wA a'-Q 7- V STAGGERED A'-D' 7-7 STAGGERED CT�a w � a�.�oswna. sunrun i CUSTOMER RESIDENCE DALE GEOHAGAN 3 COVEY DR, YARMDUTH.MA W675 fEL 7917113D1.TI72 U'N YARM-00013a-000035 PROJECT NUMBER 223R-0WGEON DESIGNER I41 S15804 .-3 GABRIEL MAHPRO SHF A SHEET LAYOUT REV A 3r17f21124 PAGE PV-3.0 e)q-?04) MAR F' Y Ntyw+emu I t OLD K1N�'S N1�,4iWAY _ 120Q10 VAC SINGLE PHASE SERVICE METER 1. --- O EVERSOURCE 231 5203 NOTE. TOTAL PV BACHFEED= UTILITY 31.25A GRID USED FOR INTERCONNECTION EXISTINGEA I CALCULATIONS / I l SERVICEERRBREAI(ER ' LWO BIDE TAP (N)LOCKABLE SLADE TYPE FUSED AC SOLAREDGE TECHNOLOGIES. ` DISCONNECT SEE000111G8 SN EXISTING 200A 5000 WATT INVERTER MAINSREANER L T ti EXISTING 225A 35A FUbE3 --- y MAIN PANEL SOUARE D LOAD RATED DC DISCONNECT 225A MAIN BUS 0222NRB WITH AFCI, RAPID SHUTDOWN FACE.ITY 3R. WA COMPLIANT LDADg - 12N210VAC CONDIRTSCHEDULE II CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE 4III0 AWO PVWRE NONE 0: In AM BARE COPPER 2 SW EMT OR EOUV 4IR10A41GTHHNITHYNb2 Now 11; 10 AWG 7HI44THN71-2 3 3N-EMT OR£aLTV (2)BAWGSHHRYTHWN-2 (1I 10AWG3HHWTHNN-2 I-S AWG THHNrtM'M-2 MODULE CHARACTERRTTCS gyp OPTIMIZER C11ARA TICS: HANVWI54 O'CELLS, O.PEAI( Dlq BLK MIN INPUT VOLTAGE: 8 VOC ML[iINR 100 ,� W OPEN RCUT VOLTAGE IS.SV MI= OTAGE E0 VOC MAX : POWER VOLTAGE: 3l.09V MAXOUTPUTCRIHRENT; 15ADC SHORT CIRCUIT CURRENTIZISA SYSTEM H_.4RACTERISTTCB-INVERTER I SYSTEM 912E MOW SYSTEM OPEN CIRCUIT VOLTAGE; 13 V MSXALLOLWBLE OC VOLTAGE: 400 V SYSTEM SHORT CIRCUIT CURRENT- 30A APP RnD APR 2 2 2024 AiNC 11M OAEWNAI[nT !:� �1 PV MODULES HANNSLA O-CELLS O.PEAX DUO BLN ML.Gi0-rt/00 = � 122) MODULES OPTIMIZERS VHRED IN. ' "I SERIES OF (9)OPTIMIZERS II) SERIES OF R73) OPTIMIZERS - SOIAREDOE POWER OPTIMIZERS Sy0 24-,� 1 0,PEAK DUO BLK ML=GlO+ SERIES 385-410Wp 1132Cells 20.9% Maximum Module Efficiency MODEL Q.PEAK DUO BLK Ml: G10+ 6 busbar cell technology The ideal solution for: Rooftop arrays on residential bu Idings 12 busbar cell technology RFC lv MAR 2`GZ.:" OnnfV1V V I . . f LD KING'S HI H I Qcells Breaking the 20% efficiency barrier I'�I JI II II 11 Q.ANTUM DUO 2 Technology with zero gap cell lay" boosts module efficiency up to 20.9% ED A reliable investment Inclusive 25-year product warranty and 25-year linear Warranty performance warranty`. Enduring high performance Long-term yield securwy with Anti LeTID Technology. acems Anti PID Technology? and Hot -Spot Protect Extreme weather rating High-tech aluminium alloy frame. certiried for high snow (5400 Pap and wind loads (4000 Pa). I., Innovative all-weather technology Optimal yields, whatever the weather with excellent law -light and temperature behaviour The most thorough testing programme in the industry Ocells is the l e solar modu a programme in t to pass the most cvmprehens ve quality programme in the industry. The APPRnVED new -Quality Controlled PV- of the independent certification ti Institute TOV Rhe--nland. APR 2 2 2024 'See data sheet on rear for lufther infor motion ' MT lcsl can cttions according to IEv rT5 62804-12015. mclhod A {--1500 V. 96 h) rwr�w� SWiI' T O,PEAK DUO BLK ML-G10+ SERIES ■ Mechanical Specification Format 74.Oln a 41.1In r 1.261n (including frame) (1879 mm - 1045mm + 32 mm) Weight 48.51bs (22.Okg) Front Cover 0.13 n (3.2 mm) thermally pre -stressed glass with anti -reflection technology Back Cover Composite film Frame Black anodised aluminium Cal 6 x 22 monocrystalllne OANTUM solar halt cells Junction box 2.09-3.98in w 1.26-2.36in x 0.5"11in 453.101mm x 32.60mm - 15-18 mm). IP67, with bypass diodes Cable 4mm' Solar cable; (9249.2in(1250mm),(-)2r49.2in{1250mm) Connector SUlubli MC4, IP68 ■ Electrical Characteristics RMFIVED MAR 2 2 2K'4- 1 hnlyIV u I I - a.e..r,es••depa-ire..1 n..e 1 ealrexsa..e 1 eernNI..i 1.er-0 .wrr4w-n +I � t]CP1eel -04- T =16 1t1 " POWER CLASS 385 380 895 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STCI (POWER TOI ERANCE -5Wr-0W) Power at MPP' P,,,,p (W) 385 390 395 400 405 410 Short Clrcult Current' Iu [A] 11.04 1107 11.10 1114 11.17 11.20 Open Circuit Voltage' Voc [V] 4519 4523 45.27 45.30 45.34 45.37 ' CLrrentatMPP I, [A] 10.59 10.65 10.71 10,77 10.83 10.89 Voltage at MPP V, [V] 36.36 36.62 36.88 37.13 37.29 37.64 Efficiency' n 1%) .19.6 219.9 z20.1 ;•20.4 r20.6 }209 MINIMUM PERFORMANCE AT NORMAL OPERArI%G CONDITIONS, 4MOT2 Power at MPP P.. Im 288.8 292.6 296.3 3001 303.8 307.6 - Short Circuit Current I, (A) 8.90 8.92 8.95 8.97 9.00 9.03 Open Circuit Voltage Vcc [V] 42.62 4265 4269 4272 4276 42.79 Curnnnt at MPP I, (A) 8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP V,1 M 34.59 34.81 35.03 35.25 35.46 35.68 'Mea-urvmr!nt tolerances Pw, 3 3%:1,,_: V. t 5%at STC:1000W1m2. 25x2 -C AM 1.5 according to IEC 60904-3 •'800W-4-I', NMOT. spr-rir im AM 15 Qcells PERFORMA4#C1= WARRANTY 4> j At least 98%of nominal power during firstyear. Thereafter maa +a•---- ----------------i 0.5%degradation per year. Al ICAS193.5%01 nominal powe4 up to 10 years. Al least 86 %of z 9 nominal power up to 25 years. All data within measurement n tolerances, roll warranties In 8 accordance with the warranty terms of the atolls sales 20 a1 organ Sahel of your respectWe 5 r.•. x, Country. -Swad" wM d euYSRee W tM 5 PV cortpagn with rtr hlghy t Preductlen capecxy In 2021 IFeWwq 20211 TEMPERATURE COEFFICIENTS Temperature Coefficient of lac a t%+K] Temperature Coefficient of P, If [iS+K] ■ Properties for System Design Maximum System Voltage Vase [V] Maximum Series Fuse Railing [AOv, Max. Design Load, Push/Pule lbs:-11' Max. Test Load, Pushl Pulp [Ibs1f6l 'See Installation Manual ■ Qualifications and Certificates UL 61730, CE-compliant, Oua Controlled PV T(hl Rheinland PERFORMANCE AT LOW IRRADIANCE �, ar „ I ug w --- -y-- >4 toe 40p for e00 1000 neADfANCE Iwrm'- TTPIceI ff O&4 ptftm-uder low Irr"d acondthr In o0n1aar4onro STGT[rtduuanl QS'C 1000Wmr1'i +0.04 Temperature Coefficient of Vuc 0 ;%:K; -0.27 -0.'4 Nominal Module Operating Temperature NMOT :T ] 109 e 5 4 (43 z 3 -C) 1000 (1EC)+1000(ULi PV module classification CAM 9 20 Fire Rating based on ANSI `UL 61730 TYPE 2 75 (3600-'a)'55 (2660Pal permitted Module Temperature -40'F up to +185'F 11345400Pa}+84 (40001`a) an Continuous Duty {--40'v' up to+85'Q MC 61215.2o16, IEC 6T730:if116, 40:1, U.S Patent No. 9,893,215 (solar cea5). Q "'W" JAPPROVED APR 2 2 2324 fARMOU Qcells pursues minimizing paper output in consideration of the global environment. NIXrWWA Wn IMhuc0iImn afell-dCo,aeaourtschf",w&afor heaminfemnemnenaPpwred tnveeemnoffluepmouct Hemha0CEUSA-ka Inc 400 Specewn Canter Orlm. SW 14M,hMe. CA 92618. USA TE- 61949748 S9 96 1 EMAIL tgc*epIry*gc*ft nn .'r•T 7 www.gcaftx= �� (],4Q` 1cells qQr / f " ' / &WARNING ELECTRICAL SHOCK HAZARD TEFV,WMS CN LBE ARID LOAD SIDES µAY BE ENBRGQEDN THE OPEN POSIIIGN LABEL L0 TION INVERTER(S) . AC=DGCONNELT{S1. AGCCYSNERRANELOFAPPIM V PER CODEM NEC m $ Ee0Met. TOTMT1. iTY.1aICI WARNING DUAL POWER SVPPLY SOURCES: UTILITY ORID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION. UTARY SERVICE METER AND TRAM SERVICE PAHEL PER CODEISINEC MS 705.3q'CI WARNING POT BoUwAOUT"COBaCTCII DO NOT RELOCATE THIS �A EOVERCURRENT DEVICE MM(IFIAPKKARl BRE). AND ESS PER COOE1aO NEC TOT] Tm_IIlBNO WARNING PHOTOVOLTAIC P0WFR ,;nuRf:F LABEL LOCATION. NTERKNI AND EXTERKIR OCCONDUR EVERY 18 FT. AT EACH TURN. AIIDVE AND EELCYA RENETAATIDNE PI EVERYA RIC B 1 MIANRq DG CFCYRS. AEA CODEM NEC TIUs an.TiIDN21 TABEL LatATld1 NSTALLEER co SOFaNUTDOYN MIS ' 2 PER OODE141 NECEt »Ea TRi +h0NT1. 1'C m1e ,m.ss MFE MAR 2 2 2""' - I nnlvlvu I I OLD KING'S HI Y SWEATER I HHUIUVULTAIG DG DISCONNECT YAilY.11 SYSIEU.'OLIKE VDC LABEL LOCATION IAON SERVICE DISCONNECT A SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN � TIIRFL RAPO SITl1IpOlA'N AWCH M 7HE'0W POSIEIOH TO SHW DD Mi PY SYSTEM AND REDUCE %*=HAZARD N TEE ARRAY. LABEL LO ATHM ON00140Y011ETHATIN ;FTIFRCYTNEWRVCE DWCDNNECTINOAIEMS TOYNHWN THE PVS NWML ME CONNECTED. PER 4M* NEC M3 TBD ITID NOTE S M D SFEf�jFIGY011a • I IONS AND LABELS SPECTRE IATTE RE0wlftEuEHf$me Ren OF TN! NEC TxI ARTICLE I LRWuE YNSFEE ERECT NaTRyCTKNa ME REOUEIEO BY SELTKN N0, OR IF AEOAND L D EY THE LL AD AHI. • IKONS AND IAHELS SHALL ADEOVMELYINARN 01 MA2AROS VBNO EFFECThE LABEL,.COLOIIS AND SYYEDIe. METHOD AND BELL NW HARAFFYIEDTO TN!EOYIPYENT OR YIKIELC LAKL AND gx xOT BeEE NANOTMRTEM. • lAE[L aN.LL EI DF IUFFK:IENf ouRABEm iOVATNSTAxD TTIE lNVEIONNENT NTVOLVED. SIGN PIQDI<T E�FETY MN9ANDaAINIA UNLESOMERMESPMFTED, • PO xOT COVER lFWTNO YANYFALTNIER LNEu. CAUTION. MULTIPLE SOURCES OF POWER SOLAR PANELS ON ROOF INVERTER (EXT) AC DISCONNECT SERVICE ENTRANCE MAIN PANEL (INT) 3 COVEY DR, YARMOUTH, MA, 02675 PER CODEM NEC M3 MS.10al APP--�- W-WEE APR 2 2 2024 rARIVIVO I r, OR ;O,A64 1