Loading...
HomeMy WebLinkAboutBLDE-23-003899 Ci'l Commonwealth of Official Use Only Massachusetts Permit No. BLDE-23-003899 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked £Rev.1/07j APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:1/18/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 28 COLBURNE PATH Owner or Tenant MOORE KERRY 1 Telephone No. Owner's Address 28 COLBURNE PATH,WEST YARMOUTH,MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(18 Panels 7.02 KW DC)(NO ESS) Completion of the following table maybe waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- CINo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and lnttiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Ton, No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Sivas No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors- Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: "Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 CIV 9- "4I2 3 &LANS Aan) Please email permit to eastmapermits@sunrun.com . . r Commonwealth o/ KliachaielLi Official Use Only _ �,lit c �J Permit No. t72.73-"Y"ri iiiiiilli 2eparin ent o�__>ipe Services Occupancy and Fee Checked - 4 BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 1/12/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location (Street & Number) 28 Colburne Path Owner or Tenant Kerry Moore Telephone No. (774) 212-1111 Owner's Address 28 Colburne Path Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps 120/ 240 Volts Overhead pi Undgrd ❑ No. of Meters 1 New Service Amps / Volts ON erhead ❑ Undgrd ❑ No. of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar energy system consisting of 18 solar panels producing 7.02 Kw DC. NO ESS Completion of the following table may be waived by the Ins ector of Wires. -Notal Trann sformers KVA No. of Recessed Luminaires No. of Ceil:Susp Tr an(Paddle) Fans f VA No. of Luminaire Outlets No. of Hot Tubs Generators KVA No. of Luminaires Swimming Pool Above ❑ In- ❑ No. of Emergency Lighting grnd. grnd. Batters Units No. of Receptacle Outlets No. of Oil Burners FIRE ALARMS \o. of Zonesof i No. of Switches No. of Gas Burners No. Initiatinnggon Dete and In Devices No. of Ranges No. of Air Cond. Total No. o f AlertingDevices Tons No. of Waste Disposers Beat Pump Number Tons._...._KW ' No. of Self-Contained p Totals: �� m Detection/Alerting Devices No. of Dishwashers Space/Area Heating KW Local ❑ Municipal 1-1 Other Connection _ No. of DryersHeating Appliances KW Security Systems:* No.of Devices or Equivalent No. of Water k« No. of No. of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent sae Bathtubs No. of Motors Total HP Telecommunications Wiring: No. Hydromassage No. of Devices or Equivalent OTHER: Roof Mounted Solar Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $9238 (When required by municipal policy.) Work to Start: ASAP Inspections to be requested in accordance with MEC Rule 10, and upon completion. INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND 0 OTHER ❑ (Specify:) I certify, under the pains and penalties ofperjury, that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services Inc. LIC. NO.: 4316 Al Licensee: Nathan Ashe Signature LIC. NO.: 21136 A (If applicable, enter "exempt" in the license number line.) Bus4 . Tel.No.: 978 594-3519 Address: 695 Myles Standish Blvd. Taunton. MA 02780 Alt. Tel. No.: 978 793-7881 *Per M.G.L. c. 147, s. 57-61, security work requires Department of Public Safety "S" License: Lic. No. WNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally RE C :■ e• . . . .' iriv. i s y my signature below, I hereby waive this requirement. I am the (check one) 0 owner ❑ owner's agent. ----- : 14 /. eiW Si nature Telephone No. I r Ng1 '7 2023 Please email permit to eastmapermits@sunrun.comPERMIT FEE: $ BUILDING DEPARTMENT By - -- — SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION roil •SYSTEM SIZE:7020W DC.6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015IRC/IBCAEBC), SERVICE ENTRANCE •MODULES:(18)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION PV-1.0 COVER SHEET NA •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2 0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:TOPSPEED,SEE DETAIL SNR-DC30004 PV-3 0 LAYOUT •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5 0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G), ODC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(A)&690.8(B)). •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). ABBREVIATIONS E 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER ';:j- 1 CHIMNEY • S u n r u KM ALMUTH COMP COMPOSITION DC DIRECT CURRENT , ATTIC VENT #,eo,zo (El EXISTING --I FLUSH ATTIC VENT VICINITY MAP STANDS.W YO.TAUNTON.NA.onaarnl ES S ENERGY STORAGE SYSTEM PVC PIPE VENT RTC.0WO 5 EXT EXTERIOR .. METAL PIPE VENT INr INTERIOR • -. _ CUSTOMER RESIDENCE: T-VENT KERRY MOORE MSP MAIN SERVICE PANEL 28 COLBURNE PATH, tN NEW _ Q SATELLITE DISH YARMOUTH,MA,02673 NTS NOT TO SCALE " TEL( GC ON CENTER �T: FIRE SETBACKS APN:YARM-000066 -0OOt87 PREFAB PREFABRICATEp JECT NUMBE PBF POUNDS PER SQUARE FOOT i ..' .- P2203R 28MOOR R. . , � HARDSCAPE PT PHOTOVOLTAIC :-• Rep RAPID SHUTDOWN DEVICE -PL— PROPERTY LINE DESIGNER: (415)580b920 ex3 n TRUNSFORAERlESS SOLAR MODULES MADISON STEVENS SCALE:NTS SHEET ITT TYPICAL REV NAME DATE COMMENTS COVER SHEET V VOLTS WATTS W REV:A 1/11/2023 LIM LANDSCAPE - TOPSPEED PAGE POE MOUNT PORTRAIT it PV-1.0 remFNM•enlM_aan , Live - `2-3 'o ,),) 'a m v z z N n D m m m u 0 cOIBURNE PATH \----- D ; . P ° A I Eo �I ISvJ rin: \ c 2 I -lir • „_, __ ,, id L_________ u i n D A D A N N O O n ZI 2.< �; N ;c m v A p IQ I. A GU m:U 1J 41 -/(� 8 < mm KN ^1O ?r >mmC .1$ co w tin m D -1 8Z Oo z> 30�0 �" o CO m nl-' Ft'. Occmm gIC '9 = 4 p oc g8 =zoz 73 p D G fil rtJ AW S; �mN a 0 r�Z ' �� O N ' 3S m "' c,_ m g C Z S w i m 9 F. ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Detail SNOW LOAD:30 PSF Span Spacing Edge Overhang Overhang WIND SPEED: • AR-01 COMP SHINGLE- 1-Story 2X6 RAFTERS 10'-9" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 2 1'-5" 0'-10" 140 MPH 3-SEC GUST. TOPSPEED _ S.S.LAG SCREW AR-02 COMP SHINGLE- 1-Story 2X6 RAFTERS 10'-9" 16" TOPSPEED.SEE DETAIL SNR-DC-30004 2 1'-5" 0'-10" WASHER WOOD SCREWS FULLY TOPSPEED PENETRATING THROUGH WOOD D1-AR-01-SCALE:1/8"><1'-0" DECK AZIM:262° PITCH:30° -{34 23 2' } • INSTALLERS SHALL NOTIFY ENGINEER OF --- ANY POTENTIAL STRUCTURAL ISSUES 2 OBSERVED PRIOR TO PROCEEDING WI 0 0 6 0 0 INSTALLATION. ---0 o o 0 rt MOUNT NUMBER FOR LEADING DOWN SLOPE 10'-11" EDGE SHALL MATCH REQUIREMENTS o 0 LISTED ABOVE INSTALL PER TOPSPEEDTM j INSTALLATION MANUAL CONTRACTOR MAY A.J SUBSTITUTE SNAPNRACK DECKTRACK 2'2" MOUNTS _Y (SNR DETAIL SNR-DC-30004)WITH MAX OVERHANG OF 6" D2-AR-02-SCALE:1/8"=1-0" AZIM.82° sunrun PITCH 30° -{3'-6" 1T-5" 15'-2" } #180120 2'-10" 0fl WIESSTIHpe1 BLVD.TAINICK weTg7.U1 BTRUC _ PHONE e 1a OF yusfcy�+1 CUSTOMER RESIDENCE: ONL 4 VINCENT Gv� KERRY MOORE u' MWUMVANEZAcrvii. N --- -I I E PATH, VARMOUTHNMA,02673 C�NIL 28 ; %f':„,,P eLk , ct t........_......... I TEL(774)212-1111 o""`E" Signed 01/11/2023 5' APN:VARM000068-000187 I PROJECT NUMBER: 223R-028MOOR 23'-10" { DESIGNER: (415)580-6920 ex3+ MADISON STEVENS SHEET LAYOUT REV:A 1/11/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 remase t"rabn_1.087 120/240 VAC SINGLE PHASE SERVICE O METER#: NOTE:TOTAL PV BACKFEED=31A EVERSOURCE 2283258 USED FOR INTERCONNECTION CALCULATIONS UTILITY GRID I -SUPPLY SIDE TAP 1I EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE8000H-USSN 1 METER 6000 WATT INVERTER JUNCTION BOX PV MODULES �Th EXISTING ti/,/A X n () OR EQUIVALENT (� TRINA SOLAR:TSM-390DE09C.07 125A MAIN f y,,11,,/// OPTIMIZERS WIRED IN: (18)MODULES l ` �� PANEL \ate 1I O — �� �� - FACILITY 35A FUSES I I (1)SERIES OF(110)OPTIMIZERS LOADS a o SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT T D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 Bib M ES 9Tud5N aW.TWMG1.w.UTAOn]t anal a inxo CUSTOMER RESIDENCE: MODULE CHARACTERISTICS KERRY MOORE TRINA SOLAR:TSM-390DE09C.07: 390 W 28 COLBURNE PATH, OPEN CIRCUIT VOLTAGE: 40.8 V S440 OPTIMIZER CHARACTERISTICS: YARMOUTH,MA,02673 MAX POWER VOLTAGE: 33.8 V MIN INPUT VOLTAGE: 8 VDC SHORT CIRCUIT CURRENT: 13.35 A MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC: 14.5 ADC TEL.(774)212-1111 MAX OUTPUT CURRENT: 15 ADC APN:YARM-000086-000187 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 223R-028MOOR SYSTEM SIZE: 7020 W DESIGNER: (415)580-8920 ex3 SYSTEM OPEN CIRCUIT VOLTAGE: 10 V SYSTEM OPERATING VOLTAGE: 380 V MADISON STEVENS MAX ALLOWABLE DC VOLTAGE: 480 V SHEET SYSTEM OPERATING CURRENT: 18.47 A ELECTRICAL SYSTEM SHORT CIRCUIT CURRENT: 30 A EV.N 1/11/2023 PAGE PV-4 0 1 emnrIe vssim_to.e7 INVERTER I NOTES AND SPECIFICATIONS. •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE s, PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD --- ----- IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS.COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECTIS) •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT , PER CODE(S)NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DSCONJECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:890.13(B) WARNING: PHOTOVOLTAIC af' W/ARNINdir POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT. SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. - - AND PV SOLAR ELECTRIC PER CODE(S)NEC 2023:890.31(D)(2),IFC 2012: SYSTEM . 605.11 1.4 cAuTION . LABEL LOCATION: I UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2023.705.12(C) RAPID SHUTDOWN MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM INA \_ DO NOT RELOCATE THIS � OVERCURRENT DEVICE LABEL LOCATION. INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION. SWITCH PER CODE(S):NEC 2023:880.51$C)(2),IFC „ $u n r u n ADJACENT TO PV BREAKER AND ESS 2012:805.11.1,FCC 201 2018:1204.5.3 PER OCPD CODE(S)F : NEC202 III -SOLAR PANELS ON PER CODE(S): EC 2023: 4., 705 1203)(3X2) , ROOF i A l `4:ii . SOLAR PV SYSTEM EQUIPPED 1 #180120 e06 wlLa Rwpel ales,r•1#.1.VA ebaYlllt PHOTOVOLTAICINER PANELEM WITH RAPID SHUTDOWN INVERTER (EXT) a DO NOT ADD LOADS ,/ CUSTOMER RESIDENCE: MAIN PANEL INT MOORE LABEL LOCATION- ( ) 28 PATH, PHOTOVOLTAIC AC COMBINER(IF NM SERVICE ENTRANCE APPLICABLE) YARMOUTH,MA,02873 PER CODE(S)NEC 202370512(D)(293)(c) 3 TURN RAPID SHUTDOWN AC DISCONNECT SWITCH TO THE"OFF" wq TEL.(774)212-1111 POSMON TO SHUT DOWN PRODUCTION METER APN,YARM-000086-000187 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:25.00 AMPS SHOCK HAZARD IN THE II 223R-028MOOR NOMINAL OPERATING AC VOLTAGE. 240 VAC ARRAY. DESIGNER. (415)580-6920 ex3 LABEL LOCATION. 28 COLBURNE PATH, YARMOUTH, MA, 02673 MADISON STEVENS AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. ' - —_ SHEET PER CODE(S):NEC 2023:890.54 tEL LOCATION. ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10,710.10 S I G N AG E DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 1/11/2023 PER CODE(S).NEC 2023:690.56(C) PAGE PV-5.0 ramp✓_w..v__aem