Loading...
HomeMy WebLinkAboutBLDE-23-004496 or Commonwealth of Official Use Only •_ [ Massachusetts Permit No. BLDE-23-004496 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/14/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 24 BARKENTINE CIR Owner or Tenant PASQUALE CARVELLO Telephone No. Owner's Address 24 BARKENTINE CIR, SOUTH YARMOUTH, MA 02664-5108 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(10 Panels 3.9 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or us required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 r E C EI jF ee- email permitQQ to eastmapermits@sunrun.com e-_ I o •ruuealtni of Va��ach.uaetbe Official�%�Use ,OnlLy r` s rt En 13 2023 ,, artment o f.fire)ervice3 Permit No. Cif/�-`f �i UMW/ Occupancy and Fee Checked 't�r•'- �: PREVENTION REGULATIONS [Rev. 1/07] 1�pl (leave blank) .y.C • ATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/09/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)24 Barkentine Cir Owner or Tenant Pasquale Carvello Telephone No. (617) 438-7228 Owner's Address 24 Barkentine Cir Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead ® Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar. 10 solar panels at 3.9 Kw DC. NO ESS. NO STRUCTURAL. Completion of the followingjable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. TotalNo.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection HeatingAppliances Security Systems:* No.of Dryers PP 1`� No.of Devices or Equivalent No.of Water Kam, No.of No. of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HPTelecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $5132 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No..978 594-3519 Address: 695 Myles Standish Blvd. Taunton. MA 02780 Alt.Tel.No.:978793'7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:3900W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SE SERVICE ENTRANCE •MODULES:(10)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN • MP MAIN PANEL PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 PV-3.0 LAYOUT •SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE 125 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER. GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •NEW 100A MAIN BREAKER DISCONNECT WITH NEW 125A •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. MAIN ENCLOSURE TO BE INSTALLED •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. 1H OF M4s SM SUNRUN METER o`'4 \MovAgsgt9°yG •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. e a CIVIL cs m� NO.56313 PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II / w N MODULES,ARE CLASS A FIRE RATED. 90 AECisTEO f"/ INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL css/oNALEN�'X� CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ERp:6/30/2024 AC AC DISCONNECT(S) 0 •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). STAMPED 02/07/2023 DC DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DEBATED CURRENT. 0 •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. ABBREVIATIONS •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n r u n AFC ARC FAULT CIgCURINTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING FLUSH ATTIC VENT VICINITY MAP S.MYLES STANDISH BLVD,TAUNTON,MA.0I7067331 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT PHONED FAX EXT EXTERIOR Ri5', METAL PIPE VENT INT INTERIOR CUSTOMER RESIDENCE: PASQUALE MSP MAIN SERVICE PANEL T-VENT nowt, 24 BARKENTINE CIR,CARVELL0 (N) NEW SATELLITE DISH • YARMOUTH,MA,02664 NTS NOT TO SCALE TEL.(508)444-6888 DC ON CENTER FIRE SETBACKS APN:YARM-000019-000048 PRE-FAB PREFABRICATED PROJECT NUMBER. PSF POUNDS PER SQUARE FOOT i . HARDSCAPE 223R-024CARV PV PHOTOVOLTAIC —PL— PROPERTY LINE O RSD RAPID SHUTDOWN DEVICE SOLAR MODULES �I,"ke".u"'I'�8 DESIGNER: (415)580-6920ex3 TL TRANSFORMERLESS LEANDRO ALCAPARAZ „d,,,,, SCALE:NTS 24 Barkentine Cir, TYP TYPICAL .1. South Yarmouth,MA REV NAME DATE COMMENTS SHEET SHEET V VOLTS 02664,United States W WATTS — ,, . . 1, ., • REV:A 2/7/2023 LAN LANDSCAPE TOPSPEED POR PORTRAIT PAGE PV-1.0 MOUNT Temp'are_ve on_a.0.87 c----Ea) ,E.,__-2z--cc SITE PLAN-SCALE=1/18"=1'-0" 1L FL •.PL4. PL PL C.1 4 d r l. .', 4° °d _ fl, • \ d• • • 0 4 g 0LSH OF Mggs4 op MOVA5y.4 c9G (E)RESIDENCE ,I CIVIL cy \ • • NO.56313 0 14 R ��? o� s EFSS/ONALO 1\a Exp:6/30/2024 \ PTA-1 il I I \ STAMPED 02107/2023 P P (N)ARRAY AR-01 sunrun #180120 OMMVlEsSTAND IBM BLVD.TALMON,NA o]rM7331 Puea FARO CUSTOMER RESIDENCE: PASQUALE CARVELLO �M� \ . 24 BARKENTINE CIR, YARMOUTH,MA,02664 ®EB� TEL.(508)444-6888 APN:YARM-000019-000048 PROJECT NUMBER: 223R-024CARV PL FL PL PL PL DESIGNER: (415)580-8920 ex3 LEANDRO ALCAPARAZ ARRAY TRUE MAG PV AREA SHEET PITCH AZIM AZIM (SOFT) SITE PLAN AR-01 25° 81° 95° 206.9 REV:A 2/7/2023 PAGE PV-2.O remplare ve n_4.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span Spacing Edge Overhang Overhang SNOW LOAD:30 PSF COMP SHINGLE- WIND SPEED: AR-01 TOPSPE 2-Story 2X6 RAFTERS 14'-6" 16" TOPSPEED,SEE DETAIL SNR-DC30004 3 1'-5" 0'-10" 140 MPH 3-SEC GUST. S.S.LAG SCREW D1-AR-01-SCALE:3/16".1'-0" (4)#14 X 2.25"SS SEALING AZIM:81° INSTALLERS SHALL NOTIFY ENGINEER OF ANY WASHER WOOD SCREWS FULL) PITCH:25° POTENTIAL STRUCTURAL ISSUES OBSERVED PENETRATING THROUGH WOOC PRIOR TO PROCEEDING W/INSTALLATION. DECK MOUNT NUMBER FOR LEADING DOWN SLOPE EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE.INSTALL PER TOPSPEEDT° INSTALLATION MANUAL.CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK (H OFMgs MOUNTS(SNR DETAIL SNR-DC-00453)WITH �t� MOVAss. . MAX OVERHANG OF 6' =3°y?� ° CIVIL N0.56313 l'o,,.4FO/SiE0.E ��`� FSSIONALOO 2,-7„-,' 29' 5' Exp:6/30/2024 STAMPED 02/07/2023 2'3" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O 0 0 0 O O O 0 0 0 7'3" O 0 0 o 0 0 0 O0 0 O0 O 00 sunrun #180120 7'-1 D" 808 MYLES STAND.BLVD,MAR.,MA 0178LL7331 ❑ 0 PHONE0❑ FAX CUSTOMER RESIDENCE: PASQUALE CARVELLO -.,- 24 BARKENTINE CIR, YARMOUTH,MA,02664 TEL.(508)444-6888 APN:YARM-000019-000048 PROJECT NUMBER: 223R-024CARV DESIGNER: (415)580-8920 ex3 LEANDRO ALCAPARAZ SHEET LAYOUT REV:A 2/7/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 Tempate_w on 4.0.87 120/240 VAC SINGLE PHASE SERVICE < OMETER#: EVERSOURCE 2308660 UTILITY NOTE:TOTAL PV BACKFEED=20A GRID- USED FOR INTERCONNECTION (1 NEW 100A MAIN BREAKER CALCULATIONS DISCONNECT WITH NEW 1 125A MAIN ENCLOSURE SIDE TAP 1 ___—LOAD (N)LOCKABLE 1 NEW 100A MAIN BLADE TYPE (N)MA SMART BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: I DISCONNECT REVENMETER 3800 WATT INVERTER JUNCTION BOX PV MODULES �„� OR EQUIVALENT o NEW 125A MAIN 3 3 Q A (10) SOLAR:TSM-390DE09C.07 PANEL f AAA A * // (10)MODULES < -�- e\o. — -� O y _ ✓• --T-- -�- —�-- - / OPTIMIZERS WIRED IN: FACILITY " I I (1)SERIES OF(10)OPTIMIZERS LOADS 20A FUSES �mOo c SQUARED 24W METER SOCKET LOAD RATED DC DISCONNECT D221NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS 3R,30A UTIUTY SIDE OF CIRCUIT COMPLIANT S440 120/24OVAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUN. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 598 MYLES STANDISH BLVD,TN.MCN,MA 02780.7331 PHONE 0 MO CUSTOMER RESIDENCE: PASQUALE CARVELLO 24 BARKENTINE CIR, YARMOUTH,MA,02664 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(508)444-6888 TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC APN:YARM-000019-000046 OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC PROJECT NUMBER: SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC 223R-024CARV DESIGNER: (415)5808920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 LEANDRO ALCAPARAZ SYSTEM SIZE: 3900 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 10 V SYSTEM OPERATING VOLTAGE: 380 v ELECTRICAL MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 10.26 A REV:A 2/7/2023 SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 Tsmpl•te w/aloB 4.B.B7 /TWA R N I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR �.' ____._______.___,_—_-._ __._._-__ .__._ .._. IF REQUESTED BY THE LOCALAHJ. MAXIMUM SYSTEM VOL LACE. 480 'MC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:890.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:890.13(B), 705.20(7),706.15(C) WARNING WARNING: PHOTOVOLTAIC DUAL POWER SUPPLY POWER SOURCE,wasmas SOURCES:UTILITY GRID LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AND PV SOLAR ELECTRIC AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SYSTEM ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:890.31(D)(2) LABEL LOCATION: UTILITY SERVICE METER AND MAIN CAUTION : SERVICE PANEL.PER CODE(S):NEC 2023:705.30(C) AWARNING 1 Luismisam S SHUTDOWN SWITCHMULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION R SOLAR PV SYSTEM ,"\ DO NOT RELOCATE THIS OVERCURRENT DEVICE lifNI LABEL LOCATION. LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC I SOLAR PANELS s u n r u n OCPD DE(S):ICABLE). 2018:1204.5.3 I ON ROOF PER CODE(S):NEC 2023:705.12(B)(2) -4.. n WARNING SOLAR PV SYSTEM EQUIPPED #180120 THIS EQUIPMENT FED BY WITH RAPID SHUTDOWN086 "°E"" "BLVD.'"""°",""°"°"33 MULTIPLE SOURCES.TOTAL MAIN PANEL INT F` ° RATING OF ALL OVERCURRENTI (INT) DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE PASQUALE CARVELLO SHALL NOT EXCEED AMPACITY OF BUSBAR I 24 BARKENTINE CIR, LABEL LOCATION: TURN RAPID SHUTDOWN I YARMOUTH,MA,02664 PV LOAD CENTER OF APPLICABLE)AND SWITCH TO THE"OFF" SOwMO SERVICE LINVERTER (EXT) TEL.(508)444-6888 ANY PANEL THAT UTIUZES"THE SUM POSITION TO SHUT DOWN ENTRANCE PV PRODUCTION METER APN:YARM-000019-000048 OF BREAKERS RULE". PV SYSTEM AND REDUCE PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE FUSED AC DISCONNECT PROJECT NUMBER: I ARRAY. Eu! 223R-024CARV PV SYSTEM DISCONNECT DESIGNER: (415)5606920 exMAXIMUMACOPERATINGCURRENT. 16AMPS24 BARKENTINE CIR, YARMOUTH, MA, 02664 LEANDROALCAPARAZ NOMINAL OPERATING AC VOL TALE, _240 VAC LABEL LOCATION: LABEL LOCATION: SHEET AC L DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) SIGNAGE INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S):NEC 2023:890.54,CEC 2022:690.54 2/7/2023 PER CODE(S):NEC 2023:690.12(D) REV:A PAGE PV-5.0 Template verso°4.°.87