HomeMy WebLinkAboutBLDE-23-003454 \ Commonwealth of Official Use Only , Massachusetts Permit No. BLDE-23-003454 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked JRev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/21/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 66 NORTH RD Owner or Tenant WAGNER CARMELLA Telephone No. Owner's Address 66 NORTH RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Rooftop solar PV, 8.97kW,23 panels Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatinc Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: _No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: NATHAN A ASHE Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Please email permit to eastmapermits@sunrun.com / Official Use Only �ommonuiea�lh ol Maeaachuiella ' _- J � Permit No.A--,3 - 3'I SDI ill lbeoarineenl of`fc7 ire_)eruicet '% BOARD OF FIRE PREVENTION REGULATIONS RevOc.c I/07 jupancy and Fee Checked(leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to he performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 12/15/2022 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)66 N Rd Owner or Tenant Odair Marques • Telephone No. (508)280-8216 Owner's Address 66 N Rd Yarmouth MA USA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected,roof mounted,photovoltaic solar energy system consisting of 23 solar panels producing 8.97 Kw DC. NO ESS Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Transformers KVA KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of k mergency Lighting grnd. grntl. Battery-Units No.of Receptacle Outlets No.of Oil Burners FIRE AL.AR\is Nu.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW ,Local 0 Municipal ❑ Other Connection HeatingAppliances S curitl S‘items:* No.of Dryers PP No,Of Devices or Equn agent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $12244 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of pedury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.•978 594-3519 Address: 695 Myles Standish Blvd.Taunton,MA 02780 Alt.Tel.No.:978 594-3519 *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S'.License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent ,t 4 Telephone No. PERMIT FEE:$ `- -•-----• --- Please email permit to eastmapermits@sunrun.com DEC 2 0 2022 BUILDING L)tfARTMENT By. — • SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION r 1 •SYSTEM SIZE:8970W DC.7680W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(23)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET J •INVERTERS:(1)DELTA ELECTRONICS:E8-TL-US INSTRUCTIONS. PV-2.0 SITE PLAN •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. Mp MAIN PANEL •RAPID SHUTDOWN:(23)APSMART RSD-S-PLC ROOFTOP PV-3.0 LAYOUT MODULE LEVEL RAPID SHUTDOWN DEVICE •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703, •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS.IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL 18 or CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). or+" Mov,� cy AC AC DISCONNECT(S) +?" CIVIL A G"�•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). o �NOT.56313 DC DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. . ';2„$,..y[_��� •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. l'oAfssTONALLT'GY� CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)8 690.8(B)]. Up:6/30/2024 •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(13)(2). STAMPED 12/15/2022 ABBREVIATIONS E.7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT �c AFC ARC FAULT CIRCUIT INTERUPTER ( CHIMNEY S u n r u n AZIM AZIMUTH •-• COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #,6o1zo MI EALRTING FLUSH ATTIC VENT VICINITY MAP suS MYIES STANOMM MAIM TAUNTON MA(Mental ESS ENERGY STORAGE SYSTEM PVC PIPE VENT R1ONM( EXT EXTERIOR METAL PIPE VENT CUSTOMER RESIDENCE INT INTERIOR ODAIR MARQUES _MSP MAIN SERVICE PANEL ..... T-VENT 66 N RD,YARMOUTH,MA,02673 Iw NEW SATELLITE DISH NT6 •NOT TO SCALE TEL.(508)280-8216 CC ON CENTER FIRE SETBACKS APN:YARM-000038-000064 PRE-FAR PRE-FABRIOATEO ;;rs PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT J HARDSCAPE bb N Rd,West 223R 088MARQ Pv PHOTOVOLTAIC Yarmouth,MA 02673'.. zs DESIGNER' (415)580-6920 ex3 ISO RAPIDSRUTDCAM1 DEVICE —PL— PROPERTY LINE SUNIL KUMAR n TRANSFORMERLESS SOLAR MODULES:NTS YARMOUTHWEST SHEET SCALE TAP TYPICAL REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS W WATTS REV.A 12i14!2022 LPN LANDSCAPE -— PAGE POR PORTRAIT TOPSPEED MOUNT Irk,. :.II F;,, PV-1.0 SITE PLAN-SCALE=3/32"=1'-0" SITE PLAN DETAIL-SCALE=3/128"=1'0" M �;j (E)RESIDENCE IACI PM INV 4 / N z R Q cr AIM" o° giv`zfall 11�MrMP °0"o4 "�c iot ` �A�'�yG SE ��— :cd c CML t N0.58313 ....;:'.::-.'... 'q :2..we_ v ''O �FOISlE0.� ��! 'SSON,LEN1s`� Exa 6/30/2026 STAMPED 12/1512022 1111MIN _ sunrun (N)ARRAY AR-01,, o #1 80120 - wTiLDE oe a*rroIa.�BLVD.TMxran.ay.MOM,�,,-_. FAX 0 ../ CUSTOMER CUSTOMER RESIDENCE: ODAIR MARQUES Ilir 66 N RD,YARMOUTH,MA,02673 ._.... _. ! ARRAY TRUE PV AREA O • PITCH AZIM (SOFT) TEL.(508)280.8216 AR-01 28° 97° 476 APN:YARM-000038-000064 PROJECT NUMBER: 223R-O66MARQ DESIGNER: (415)580-6920 ex3 SUNIL KUMAR SHEET NOTE:ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE SITE PLAN INSTALLED ON EACH MODULE PER NEC 690.12 REV:A 12/16/2022 PAGE PV-2.O iempre_—_.0eZ i. ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span SpacingEdge Overhang Overhang SNOW LOAD:30 PSF COMP SHINGLE- WIND SPEED: AR-01 TOPSPEED1-Story 2X8 RAFTERS 5'-11" 20" TOPSPEED,SEE DETAIL SNR-DC-30004 2 1'-5" 0'-10" 140 MPH 3-SEC GUST. S.S.LAG SCREW D1-AR-01-SCALE:114":1'-0" (4)1/4"WOOD SCREWS FULLY AZIM:97" PENETRATING THROUGH WOOL PITCH:26° DECK 4.-5" - - 34'-10" -- --- .--- I o�4' yAv414`F. --0 0 0 0 0 0 0 0 0 0 0 0 — o� CIVIL'�.1.e 'a i t ��NO.56313 • • .wyL. j cs'DO AFGI6IEP,�4� I 4siortALE"c'\ 0 0 O O O Q O 0 r- 0 0 0 0 1 Up:6/30/2024 I STAMPED 12/15/2022 0 0 0 O _ 0 .- _E3 O 0 O O 14'7' sunrun � J0 0 0 0 0 0 0 0 0 ' 8180120 o CUSTOMER RESIDENCE. 0 0 (_) 0 0 0 0-- • ODAIR MARQUES 66 N RD,YARMOUTH,MA,02673 7"-' INSTALLERS SHALL NOTIFY ENGINEER OF ANY TEL.(508)280-8216 POTENTIAL STRUCTURAL ISSUES OBSERVED ApN.Y 8)2 000o39-000064 PRIOR TO PROCEEDING W/INSTALLATION PROJECT NUMBER. Note: 223R-O66MARQ MOUNT NUMBER FOR LEADING DOWN SLOPE EDGE SHALL MATCH DESIGNER (415)580-6020 ex3 REQUIREMENTS LISTED ABOVE SUNIL KUMAR INSTALL PER TOPSPEEDTM INSTALLATION MANUAL SHEET CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK LAYOUT (SNR DETAIL SNR-DC-00453)WITH MAX OVERHANG OF 6"h. SEE SITE PLAN FOR NORTH ARROW REV A 12/14/2022 PAGE PV-3.0 "mNae_w,s—_.,0 137 120/240 VAC SINGLE PHASE SERVICE OMETER#: EVERSOURCE 2286670 UTILITY NOTE:TOTAL PV BACKFEED=40A GRID I USED FOR INTERCONNECTION // SUPPLY SIDE TAP CALCULATIONS f I EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY DELTA ELECTRONICS: DISCONNECT REVENUE E8-TL-US 1 METER 7680 WATT INVERTER JUNCTION BOX PV MODULES ///�`J��� OR EQUIVALENT �� 3 Z n r/ TRINA SOLAR:TSM-390DE09C.07 ti EXISTING X `� / (23)MODULES < 125A MAIN o,m, IJ O ✓ `T _ .�i J —�. '�li�/ (1)STRING OF(8)MODULES f ACILITY PANEL (Y (1)STRING OF(7)MODULES LOADS m. 4OA FUSES I I (1)STRING OF(B)MODULES o`l..awo SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L(23)APSMART RSD-S-PLC MODULE 3R,BOA UTILITY SIDE OF CIRCUIT COMPLIANT LEVEL RAPID SHUTDOWN DEVICES 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 sun r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 .w.e a GO 0 CUSTOMER RESIDENCE: OOAIR MARQUES 68 N RD,YARMOUTH,MA,02673 MODULE CHARACTERISTICS TEL.(508)280.8218 TRINA SOLAR:TSM-390DE09C.07: 390 W APN:YARM-000038-000064 OPEN CIRCUIT VOLTAGE. 40.8 V MAX POWER VOLTAGE: 33.8 V PROJECT NUMBER: SHORT CIRCUIT CURRENT: 13.35 A 223R-O66MARQ DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUNIL KUMAR SYSTEM SIZE: 8970 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 361 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 270 V MAX ALLOWABLE DC VOLTAGE: 480 V -- SYSTEM OPERATING CURRENT: 34.62 A REV.A 12I14I2022 SYSTEM SHORT CIRCUIT CURRENT. 50.06 A PAGE PV-4.0 7.10ale_vra .O.87 NOTES AND SPECIFICATIONS' /WARNING INVERTER 1 •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 880.OR PHOTOVOLTAIC DC DISCONNECT IF REQUESTED BY THE LOCAL AHJ. ELECTRICAL SHOCK HAZARD •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM SYSTEM VOLTAGE 480 VDC WORDS.COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION. •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT THE OPEN POSITION INVERTER(S).DC DISCONNECT(S). INVOLVED. PER CODEIS).NEC 2020.690.53 •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z5354-2011,PRODUCT SAFETY LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S). •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPLICABLE). PER CODE(S).NEC 2020 690.13(8) WARNING: PHOTOVOLTAIC A ARNING POWER SOURCE LABEL LOCATION DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN.ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. _ - - - - - -- - AND PV SOLAR ELECTRIC PER CODE(S)NEC 2020:690.31(D)(2),IFC 2012 SYSTEM 6051114CAUTION : LABEL LOCATIONUTILITY SERVICE METER AND MAIN SERVICE PANEL AWARNINGPER RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS , OVERCURRENTDEVICE LABEL LOCATION. SOLAR PANELS- -�' \�/ INSTALLED WITHIN 3'OF RAPID SHUT DOWN ON ROOF 1 LABEL LOCATION: SWITCH PER CODE(S),NEC 2020 890.58(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012.605.11.1,IFC 2018:1204.5.3 1 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020 _ q _. 705 12(8)(3X2) AWARNING #180120 . SOLAR PV SYSTEM EQUIPPED PHOTOVOLTAIC SYSTEM MAIN PANEL (INT) OM `�s""""°"°°'"�""°"""°"°""' COMBINER PANEL WITH RAPID SHUTDOWN M° DO NOT ADD LOADS CUSTOMER RESIDENCE: ODAIR MARQUES LABEuocATloN. —SERVICE ENTRANCE 66 N RD,YARMOUTH,MA,02673 PHOTOVOLTAIC AC COMBINER(IF 4iib • R ) PERCODE(S. 3" TURN RAPID SHUTDOWN PER CODEIS):NEC 2020 705.1210)12X3)Ic) SWITCH TO THE"OFF" TEL.(508)280.8216 POSITION TO SHUT DOWN APN.YARM-000038-000064 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:32.00 AMPS SHOCK HAZARD IN THE INVERTER (EXT) 223R•O6BMARQ d I 1 NOMINAL OPERATING AC VOLTAGE 240 VAC ARRAY. E PV PRODUCTION METER LABEL LOCATION: FUSED AC DISCONNECT DSUNIL KUMAR (4)5)580-8820 ez3 AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF 66 N RD, YARMOUTH, MA, 02673 INTERCONNECTION. _ SHEET PER COOE(S):NEC 2020:690.51 LABEL LOCATION: PER CODE(SI:NEC 2020 705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED REV:A 12/142022 PER CODE(S).NEC 2020-890.56(C) PAGE PV-5.0 r.,flSQ.im°_•o87