Loading...
HomeMy WebLinkAboutBLDE-23-003635 ‘I) Commonwealth of Official Use Only Massachusetts Permit No. BLDE-23-003635 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK • All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:1/4/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 46 SQUIRREL RUN Owner or Tenant PHILIP LEE Telephone No. Owner's Address 95 HANK WILSON RD, CADYVILLE, NY 12918 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(20 Panels 5.8 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters ,Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Brett A Duguay Licensee: Brett A Duguay Signature LIC.NO.: 22079 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:41 ELK RUN, MIDDLEBORO MA 023463065 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 (bit crilo Ie^a) i/eo%r. P * ,t Commonwealik of?�addac eitd Off i J s.c* �� c� 1 ��7] Permit No. -� -mod� E a _ �I— 2eparfineni of ire Serviced _ e' ;—�- BOARD OF FIRE PREVENTION REGULATIONS Occupancy and he ,� � 9 [Rev. 1/07] (le ,lank) 03 202 APPLICATION FOR PERMIT TO PERFORM ELEC a���DA-- .All work to be performed in accordance•with the Massachusetts Electrical Code(MEC),527 CMR T 120 t '--_ — • (PLEASE PRINT IN INK OR PE ALL INFORMATION) Date: 9 r� City or Town of: \ ��m�r '�`�1 �a�a di By this application the undersigne gives��ce of his or her intention to perform To the Inspector electrical o Wires: Location(Street&Number) L � St work described below. ,Owner 'or Tenant A . l �l u � �u'� �' - '�` '� 1 + )� `� Q `` Telephone No.GI� 5�1 •3�0�0 Owner's Address\AV ' Ma_1( % n S\ . \ 1^L vdu T m ( AL -As Is this permit in conjunction with a building permit? Yes No 1��\�11i� ��;;� Eli (Check Appropriate Box) Purpose of Building f I�u„. Utility Authorization No, Existing Service Amps - / . Volts Overhead ❑ Undgrd❑ No.of Meters New Service .Amps / Volts Overhead ❑' Undgrd D No.of Meters Number of Feeders and Ampacity �Lovcaatiio�n1 and tore of Propose(' Electrical (W�or\k:�,,� a �1 1 ll\ lX \1� �1V v) . i6 L ,�Suc�� c. . Completion of the followingtable tae may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total • Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA • No.of Luminaires Swimming Pool Above ❑ In- No.of Emergency Lighting . „rnd. grnd. ❑ Battery Units • No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and • Initiating Devices No.of Ranges Total No.-of Air Cond. Tons No.of Alerting Devices •No.of Waste Disposers Heat Pump Number Tons I KW No.of Self-Contained Totals:1 �`"-`�'-�"""'"' """ Detection/Alerting Devices No.of Dishwashers • $pace/Area Heating KW Local❑ Municipal Connection ❑ Other No.of Dryers • Heating Appliances KW Security Systems:* No.of Water No.of No.of Devices or Equivalent No. of Heaters KW Data Wiring:Signs Ballasts No.of Devices or Equivalent • No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: • Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value f Electrical Work: (When required by municipal policy.) Work to Start: ( ' Inspections to be'requested in accordance with MEC Rule 10,and upon completion. INSURANCE C V RAGE: Unless waived by the owner,no permit for the performance of electrical work may, issue unless the licensee provides proof of eci liabili insurance including"completed operation?'coverage or its substantial equivalent. The undersigned certifies that such coy ge is in force,and has exhibited proof of same,to the permit issuing office. CHECK ONE: INSURANCE BOND 0 OTHER ❑ (Specify:) I certify, under the pains and penalties of erjury,that the in rmation.on this application is true and complete. FIRM NAME: 60 c c Ong)i `3JN\( 1 # �S�1(nnr- �_�._.Cr LIC.NO.: 0)0) R I Licensee: W ail.„ , Signature ° A c�a�s J LIC.N O.: (If applicab ter exem he lice se number Ale.) Cp \ �Ck, C� nti .Tel.No.:�� ! �f_ Address: ` ►>n r- , �� (SPA *Per M.G.L.c. I47,s.57-61,security wo k r quires Department of Public Safety"S"License: It.L c.No. �� � , OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑ owner ❑ owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $150.O I DESCRIPTION OF SYSTEM CONSTRUCTION NOTES • SYSTEM SIZE: 8000W DC, 5800WAC • CONTRACTOR SHALL COMPLY WITH FEDERAL OSHA, AND LOCAL REGULATIONS PERTAINING TO WORK PRACTICES, PROTECTION OF • MOUNTING TYPE: IRONRIDGE FLASHFOOT 2 WITH IRONRIDGE XR-100 RAILS WORKERS AND VISITORS TO THE SITE. • ELECTRICAL TYPE: GRID TIED • ALL NECESSARY PERMITS SHALL BE OBTAINED, AND ALL RELATED PERMIT FEES SHALL BE PAID BY CONTRACTOR PRIOR TO • CUSTOMER NAME: LAGREE, SUSAN COMMENCEMENT OF WORK. WORK REQUIRED INCLUDES ALL LABOR AND MATERIALS, EQUIPMENT ETC. NECESSARY AND ADDRESS: 46 SQUIRREL RUN ST., YARMOUTH PORT, MA 02675 REASONABLY INCIDENTAL TO COMPLETE THE SOLAR PROJECT. • • ALL EXISTING CONDITIONS, DIMENSIONS AND QUANTITIES AT SITE MUST BE FIELD VERIFIED BY CONTRACTOR BEFORE COMMENCING WORK. CAZEAULT SOLAR IS NOT RESPONSIBLE FOR SITE INACCURACIES. IF ANY DISCREPANCIES ARISE, SOLAR ROOF DYNAMICS DESIGN CRITERIA • SHALL BE NOTIFIED PRIOR TO COMMENCEMENT OF WORK. • ALL MATERIALS INSTALLED ONSITE, SHALL BE IN NEW AND UNUSED CONDITION AND OF HIGH QUALITY IN EVERY RESPECT. • MANUFACTURER'S MATERIAL, EQUIPMENT, ETC. SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND SYSTEM SIZE: 8000W • WIND SPEED: 140 MPH INSTRUCTIONS. • EXPOSURE CATEGORY: C • CONTRACTOR AND WORKMEN SHALL WEAR ALL REQUIRED PERSONAL PROTECTIVE EQUIPMENT AT ALL TIMES WHILE ON-SITE MODULES: • SNOW LOAD: 30 PSF • CONTRACTOR SHALL COMPLY WITH ALL FIRE SAFETY REGULATIONS AS THE LAW PRESCRIBES. • OCCUPANCY: II • THE CONTRACTOR SHALL BECOME FAMILIAR WITH ROOF STRUCTURAL PLAN, UTILITY AS-BUILT PLANS AND THE LOCATIONS OF ALL (20) SOLARIA POWER XT-400R-PM EXISTING UTILITIES AND STRUCTURES. INVERTER: • THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES OR STRUCTURES. ENPHASE iQ8PLUS-72 2 US CODES • EQUIPMENT STAGING AREA, LADDER ACCESS AREA, INDOOR ATTIC ACCESS, NOISE LEVELS, PARKING AREA, WORK HOURS ETC ALL WORK SHALL BE PERFORMED IN COMPLIANCE TO ALL SHOULD BE DISCUSSED WITH OWNER PRIOR TO COMMENCEMENT OF WORK. • GOOD HOUSEKEEPING IS ALWAYS EXPECTED. TRASH SHOULD BE REMOVED AS FREQUENTLY AS NEEDED TO ENSURE A TIDY AND SURFACE TYPE: ROOF PERTINENT REGIONAL AND LOCAL CODES, REGULATIONS, LAWS, AND SAFE WORK ENVIRONMENT. ORDINANCES AS REQUIRED BY THE STATE OF MASSACHUSETTS: • ALL WORK SHALL BE INSTALLED IN CONFORMANCE WITH CONSTRUCTION SPECIFICATIONS. AHJ: YARMOUTH TOWN 2015 INTERNATIONAL BUILDING CODE (IBC). CONTRACTOR: ELECTRICAL NOTES: 2015 INTERNATIONAL RESIDENTIAL CODE (IRC). • THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A 2015 INTERNATIONAL FIRE CODE (IFC). QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE . 2016 INTERNATIONAL MECHANICAL CODE (CMC) 2016 INTERNATIONAL PLUMBING CODE (CPC) ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECIEVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(E) AND 705.6) aaearr(ei t 2020 NATIONAL ELECTRICAL CODE (NEC) • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A ASCE/ANSI 7-10MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER e LINE SIDE TAP CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. solar STRUCTURES VECTOR • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS ADDRESS:92 GROVE STREET,GLOUCESTER,MA01930 ■ n • t n ■ ■ R . AP��H OF MAss PHONE:978-281-4625 �� q0 AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. ee W.OwL(M. 13402C ..r[. i0r . .soil 990-r77e • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. PROJECT NAME: . UrwwB40�C www.veCrow.cCau ç JACdB S. GVSE Project Number: U3014.0377.221 • OR • ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 314.15A). ., LAGREE, SUSAN Vector Structural Engineering has'eviewed the existing structure with loading SEPARATION DISTANCE MEASUREMENT FROM BOTTOM OF PANEL TO TOP OF ROOF COVERING SHALL BE MINIMUM 3 .• WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT the racking system,racking connections,and all other structural is by others. PROJECT ADDRESS: Mechanical,architectural,andlothernonstructuralaspofthesign are Fe P, 4, WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT. WIRING by others.Electrical is by others,unless stamped by Dean Levo'Sen• 0� E \ METHODS FOR PV SYSTEM CONDUCTORS MUST BE RUN PERPENDICULAR (90°) TO THE ROOF PENETRATION POINT. (NEC 690.31(E)) 46 SQUIRREL RUN ST., VICINITY MAP 11/03/2022 • BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. YARMOUTH PORT, MA 02675 { .^-•-w—W-"Tf \ ; '-- • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. TEL.# 978 soi 368o APN# YpRM 1zas000sn0000 • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 AND IFC 2015 r * 'g... • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. JOB NUMBER: 11769 Y � THE MEANS OF ID CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. 690.4) I � (NEC( DRAFTER: Y LI ;; '"+� ° • MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY • ` - .3\,- 4 SOLAR EQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED. 1 i' 7 , :. , ., ,, f ,r --t REVISION HISTORY 1 r 1` ! ,.." ^`� S ABBREVIATIONS REV DESCRIPTION DRW DATE MAC MAGNETIC 0 DRAFTER REVIEW AH 10-05-22 ""''Yarmo�'uth ' INDEX A AMPERE MSP MAIN SERVICE PANEL 1 COMMENTS INCORPRATED NN io is zz '' 1,4 ., � .,. " ` # PAGE DESCRIPTION AC ALTERNATING CURRENT (N) NEW 2 COMMENTS INCORPRATED AH 10-29-zz ' ' •' ® � AFC! ARC FAULT CIRCUIT INTERRUPTER NTS NOT TO SCALE 46 Squirrel RL,n `‘T' 4. - - PV-01 COVER PAGE AZIM AZIMUTH OC ON CENTER 3 4 t St, Yarmouth port, MA... ~``'� PV-02 SITE PLAN COMP COMPOSITION PRE-FAB PRE-FABRICATED I . ��.. i DC DIRECT CURRENT PSF POUNDS PER SQUARE FOOT 5 (i-/ . ) i' #, , �.' PV-03 STRUCTURAL DETAILS (E) EXISTING PV PHOTOVOLTAIC 6 f '`"" \ • - PV N. -3.1 MOUNTING PLANE DETAILS EXT EXTERIOR TL TRANSFORMERLESS - It;» �` ,'----, • FRM FRAMING TYP TYPICAL PV-04 ELECTRICAL DIAGRAM SHEET ��� ' 1` _ INT INTERIOR V VOLTS A •' r f. `" � CALCULATIONS COVER SHEET i \ (_Y PV-05 ELECTRICALLBW LOAD BEARING WALL W WATTS `' t. .1 ' . A A .,- . (1 7', ,/ PV-6 SIGNAGE SCHEDULE REV: 2 I •'� ''•, ` PV-6.1 PLACARD ! -,.- ; ; . --_1' �\ I PAGE PV-1 .0 c-- . t rs�' ...4 . .� . '\., • '' � i. ' � PV-7.0 DATASHEET - _ ' MOUNTING PITCH TRUE ROOF TYPE ROOF #OF PLANE AZIMUTH STORY MODULES SITE PLAN-SCALE:1N6"=1'-0" MP-01 28° 105° ASPHALT SHINGLE ONE 20 ® MP ) VECTDR (E)RESIDENCE © m (N)CONDUIT w*-F es,w ,p till RUN(IN ATTIC) e n a 1 n e c N e ARRAY AZIMUTH eno�o,`jH OF ASs�,,,w,ao,owaa.�o" DRIVEWAY LCJ 105 DEGREE'S yGm ��4'_'/ I SYSTEE0R.PM • 4. �� 114'-3"a.11/03/2022 � r VSE Project Number:U3014.0377.221 ' t •� SURFACE TYPE.ROOF Vector Structural Engineering ties reviewed the existingZ. 0'-3" structure wen loading from the solar array and screw J •* �� AHJ: YARMOUTH TOWN rconnections to the existing framing.The desgn o/the N acking system,ra kmg connect.,ache all other CL ...rural is by others.Mechanical.architecture!,and all / .• CONTRACTOR: Other npuwctural aspects of the design are by others. J / Cr Electrical is by others,unless Stamped by Dean Levorsen. (i Ct o / ea�eauC1 `///���^J 102'-3" solar & home P ,�% • I ADDRESS:92 GROVE STREET,GLOUCESTER.MA 01930 / O PHONE:9T&2S,J825 F • PROJECT NAME: _ ® _43' x LAGREE,SUSAN / hillir. PROJECT ADDRESS: i46 SQUIRREL RUN ST., /-----"------- YARMOUTH PORT,MA 02675 34'` •� 102'-10" TEL R: 978-501-3680 APN M vn.rnwuhwaxnonp �•• / JOB NUMBER:11769 LEGEND AND ABBREVIATIONS / , DRAFTER: SOLAR MODULES IMSPI MAIN SERVICE PANEL 1—f RAIL I REVISION HISTORY UM UTILITY METER REV DESCRIPTION DRW DATE !\ , 0 DRAFTER REVIEW AH 10-0522 SM SMART METER 1 COMMENTS INCORPRATED NN 10-18-22 ATTACHMENTS _R 24r-8rr I I MICRO INVERTERS FIRE SETBACKS ` `„ / a COMMENTS INCORPRATED Ail 10-29-22 , a LA LADDER ACCESS 5 WALKWAY ` / q ^ 6 7 IACBI AC COMBINER BOX 8 —PL—PROPERTY LINE , Ac AC DISCONNECT (N)MP-01 121'4" _, SHEET — EXTERIOR CONDUIT RUN _, SITE PLAN —nJUNCTION BOX —INTERIOR CONDUIT RUN (E)PROPERTY LINE REV:2 / \ / /// \\l I— INTERIOR EQUIPMENT ..4 PAGE PV_2.0 L J SHOWN AS DASHED . STRUCTURAL NOTES: ATTACHMENT DETAILS-1:SCALE-NTS - SNO. MOUNTING SYSTEM - -- -- -- - TOP VIEW TOP VIEW IRONRIDGE RAIL 1 MOUNTING TYPE IRONRIDGE FLASHFOOT 2 I _ MODULE FRAME A i� � MODULE FRAME 2 MOUNTING WEIGHT PER MODULE(LBS.) 9.84 END CLAMP �1,0 1 � � MID CLAMP ijI,/ SOLAR CELLS 3 TOTAI MOUNTING WEIGHT(LBS.) 197 sown cELLs ,�� � 4 MAX.ATTACHMENT POINT SPACING 48 IN. 5 MAX RAIL OVERHANG 24 IN. SYSTEM SIZE:8000W ,,t_-,_, STRUCTURE DETAILS MODULES: SNO. „ 4W;� _ SOLAR MODULE 1 TOTAL SYSTEM WEIGHT(LBS.) 1117 SNO. SITE DETAILS (20)SOLARIA POWER XT-400R-PM 2 TOTAL#OF ATTACHMENTS 58 1 FRAMING TYPE RAFTERS 111\ � INVERTER: 2 RAFTER SIZE 2"X 8" IRONRIDGE XR-100 RAILS ENPHASE IQ8PLUS-72-2-US 3 WEIGHT PER ATTACHMENT(LBS.) 19.26 -3 RAFTER SPACING 16 IN.O.0 4 UNDER 45 LBS. YES IRONRIDGE FLASHFOOT 2 SURFACE TYPE:ROOF 4 RAFTER SLOPE 28' ` WEIGHT PER SQUARE FOOT FLASHING AHJ:YARMOUTH TOWN 5 2.62 5 FASTENERS PER ATTACHMENT 1 ASPHALT SHINGLE (LBS./SQ.FT.) -_ RAFTERS CONTRACTOR: 6 FASTENER SIZE 5/16" 6 UNDER S LBS./SQ.FT. YES 7 EMBEDMENT DEPTH 2.5"(MIN.) LAG SCREW EMBEDMENT --::- SNO. SOLAR MODULE SPECS n 1 MODULE TYPE SOLARIA POWER XT-400R-PM SIDE VIEW a eL4et CV Cl.solar & home 2 MODULE WEIGHT(LBS.) 46 ADDRESS.92 GROVE STREET,OIOUCEBTER MA 01930 PHONE:976291-4823 3 MODULE AREA(SQ.FT.) 21.30 END CLAMP MID CLAMP 4 MODULE IN ARRAY 20 MODULE FRAME aft a MODULE FRAME PROJECT NAME: �19! LAGREE,SUSAN 5 TOTAL MODULE WEIGHT(LBS.) 920 IRONRIDGE RAIL t� IRONRIDGE RAIL 6 TOTAL MODULE AREA(SQ.FT.) 426 PROJECT ADDRESS: SIDE VIEW SIDE VIEW 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 TEL.•: 978-501-3680 APN M-.,.e«w123mm17u,oro VECTOR JOB NUMBER:11769 Y ECTOR DRAFTER: e n • I nee • • ASPHALT or SHINGLE �� °" a'°'°o "":• •�"�ro REVISION HISTORY PV MODULE ,4`1NOF gss4c lov oaAFrEala�wD'IW lo�sxx SEE(ATTACHMENT-1) G, '•3P' yc, 1 COMMENTS INCORPRATED NN 1018.22 FOR ENLARGED VIEWs:16e O s y 2 COMMENISINCoaPMTED AM 102922 �p 3 iiii II 4 �0 y�Q- pX EP + '� 7' FSS/ONAL EN�' 6. mo 7 11/03/2022 e / �/ VSE Project Number.U3014.0377.221 SHEET Vector 5i,,c,ural ct Number:U3„ existingewed the . STRUCTURAL DETAILS structure with loading from the solar array and screw rusections to the existing framing.The design of the REV:2 cking system,racking connections.end all other a4uaurei is by others.Meehan.,architectural.and an PAGE other nonstructural aspects Elamm®lby others..uyye or the design are by oehera. PV-3.0 unless stamped by Dean Leworsen. MOUNTING PLANE-1:SCALE-3/16"=1'=0" WE 5 ARRAY AZIMUTH 105 DEGREES 68'-7n SYSTEM SIZE:8000W /3" 36'-r 4'TYP. 32' MODULES: 3 _ (20)SOLARIA POWER XT-400R-PM _4L-1-1-1.-1_1-1-�-1-1--1-1-4—T--1 4—,I I 1 1-1 -1 1 —1 h INVERTER: 11 11 I 1 1 I 1 I I I 1 I l I r ► I r I I I I I - - _ ---- ENPHASEIQBPLUS-72-2-US 1I I _ I I_ I _I_ I---r-+- I I _I 11 1 I I r T rZ T-F1-ram r1--rt-1---r-1- --1— — 1— — 1_ 1- I I I I -.-f- I I I I SURFACETYPE:ROOF I I I I I I I I I � I I I ° I ITT r�- -r--�-r-i ,�-- 12'-2e --t- t t"I t-1- ❑ { 1—• 1-1—• r 1—. AHJ:YARMOUTH TOWN 16' r 1 r r-I T r l 1 I 11 1 I I I I I I I I I I 1 I I 4: —I--4I —1—• CONTRACTOR: 1 I 1 1 I I 1 I 1 1 1 1 I 1 I I 1 1 I 1 I I I I I I I I I I 14-8e t r- -1-1- --1-1--1-1- 1 1 1 1 1 I 1 I I I 1 1 1 1 I 1.4 ._I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I 1 I I I I I I .-1--1-.-1--1-. ea ea + homy 1 I I I I 1 I I I I I I I ' 15'-8" 1 I 1 i 1 1 ADDRESS 92 G OVEHONER9E T,GL 6yCESTER.MA 01930 3'-7- 1 ! 1 1 1 1 1 1 1 1 1 1 1 1 IJ I I I I 1 1 11 PROJECT NAME: 22' I I k 30'-10• LAGREE,SUSAN 2'-8e i 63'-4" a' 2,-8, PROJECT ADDRESS: I- 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 2"X8" RAFTERS @ 16" O.C. , MP-01 TEL.e: 978-501-3680 APNa:rxaw+reussmnnasm *ECTOR DOANUMBER:11769 ■ •n i n e • R • DRAFTER: nr ID Allow ` SOLARIA POWER REVISION HISTORY .40IL OF 40 XT-400 MODULES REV DESCRIPTION DRW DATE yN ,r 47.4"I' 0 DRAFTER REVIEW AH MOS-22 1 COMMENTS INCORPRATED NN 10-18-22 �-.A+�►5R 2 COMMENTS INCORPRATED AM 30-19-22 to y 1 PLO 4? G}r ` - E \ g 5 .88/ONAL ENG 6 11/03/2022 8 VSE Project Number:U3014.0377.221 LEGEND SHEET MOUNTING PLANE Vector Structural Engineering hes reviewed the existing DETAILS structure with loading from Na solar"nay end screw • connections to the existing kerning.The design of the 0❑ -VENT,ATTIC FAN(ROOF OBSTRUCTION) racking system.resins connections,and all other REV:2 structural a by others.eechemcal,archdectunl,and all -ROOF ATTACHMENT other nonabcu.ual aspects of Me design an by others. PAGE PV-3.1 Electrical le by others.unless stamped by Dean Levorsen. ———— -RAFTERS ELECTRICAL DIAGRAM: KEY EQUIPMENTIOW' O (E)MAIN SERVICE PANEL 200A RATED WITH MAIN BREAKER 1 200A RATED OB (N)INVERTER-ENPHASE IQ8PLUS-72-2-US[240V] 20 CD (N)MODULE-SOLARIA POWER XT-400R-PM 20 OD (N)SMART METER 200A RATED 1 O (N)AC COMBINER BOX-ENPHASE IQ COMBINER 4/4C 80A RATED WITH(2)20A/2P BREAKERS 1 SYSTEM SIZE:8000w O (N)60A RATED NON-FUSED AC DISCONNECT 1 MODULES: (20)SOLARIA POWER XT-400R-PM NOTES: INVERTER: 1. ENPHASE 10 ENVOY FOR SOLAR PRODUCTION MONITORING ONLY. ENPHASE IQ8PLUS-72-2-US 2. JUNCTION BOXES ARE NOT SHOWN,BUT MAY BE USED FOR TRANSITION POINTS THROUGHOUT SYSTEM. SURFACE TYPE:ROOF AHJ:YARMOUTH TOWN DO(N)10 MICROINVERTERS IN BRANCH CIRCUIT 1 CONTRACTOR: i I ... i I I...-•---., (E)MAIN SERVICE -� ``— PANEL(200A RATED) (E)UTILITY METER /�^I�� m� � -- --,� � WITH 2O0A RATED �p2R3828� ( VQ^e/y.0 Qt dItiJ/� lirg p10 THWN-2 p10 THwN-2 MAIN BREAKER \V V{7- M. ■ IN 3/4'FMC/EMT IN 3/4'FMC/EMT L1=BLACK Li BLACK MOD solar& home L2-RED L2 RED N=WHITE N•WHITE 27 (N)10 MICROINVERTERS IN BRANCH CIRCUIT 2 #10 THWN-2,O=GREEN p10 THWN-2.G-GREEN ADDRESS 92 GROPHONE._ _FESTER,MA 01930 978-28 PROJECT NAME: 1 ---- - ... I , 1 nu■fu■■o� I iiionofo■ f ----' f I (N)NON-FUSED AC • LAGREE,SUSAN (, _� DISCONNECT —— —— —J BOA RATED P 3.5.40,BREAKER t"Lf PROJECT ADDRESS: ■ J y 46 SQUIRREL RUN ST., (N)JUNCTION ® I N I I N I YARMOUTH PORT,MA 02675 BOX (N)ENPHASE ID COMBINER 4/4C I G I AC COMBINER BOX I— A-- ———Y— TEL-t. 978-501-3680 APNI:....11D*o�+f� MA RATED) - 11769 EiEooE UTILITY GRIDJOB NUMBER: / RED BLACK L215) DRAFTER: BED 1f a Q RED Lz SMARTR200A METERD U, RATED REVISION HISTORY REV DESCRIPTIONDPW DATE ENPHASE O CABLES 0 DRAFTER REVIEW AH 1005.22 2P 1 COMMENTS INCORPRATED NN 1418-22 _� I 2 COMMENTS INCORPRATED AH 10-29-22 3 IT (4)412AWG THWN-2 8 (1)412 AWG THWN-2 GND. 410 THW N-2 SHEET (1)3/4'FMC/EMT CONDUIT IN 3/41 FMC/EMT OR NM CABLE LI-BLACK ELECTRICAL DIAGRAM L2=RED N=WHITE REV:2 p10 THW N-2,G=GREEN PAGE PV-4.O NOTE:ALL CONDUIT ON ROOF MUST BE 0.5"-3.5"HIGH ABOVE THE ROOF SURFACE. APPROXIMATE NOMINAL CONDUCTOR TEMP CORR. AREA OF INTERNAL AREA FILL FACTOR AMBIENT TEMP.ADDER TOTAL RATING IN DERATED OCPD #OF CONDUIT/ FACTOR CONDUCTOR CONDUCTOR CONDUIT OF CONDUIT IN (NEC 2020 TEMP.IN (NEC 2020 TEMP IN AMPERE CURRENT (NEC-2020 DESCRIPTION SIZE (NEC CONDUCTORS SIZE SQ.INCH(NEC WIRE FILL TABLE DEGREE Table DEGREE (NEC-2020 (NEC-2020 RATING IN ARTICLE-6 CHAPTER-9 PER CONDUIT CHAPTER-9 PERCENT 310.15(B)(3)(a)) CELCIUS 310.15(13)(3)(c)) CELCIUS TABLE-310.15(B) AMPERE 90.8) TABLE-5) TABLE-04) TABLE-310.1 5(B)(2)(a)) (16)) JUNCTION BOX TO AC 12 AWG 0.0133 4 3/4"EMT 0.533 9.98% 0.8 28 22 50 0.82 30 19.68 20A COMBINER BOX _ _ AC COMBINER BOX TO POINT OF 10 AWG 0.0211 3 3/4"EMT 0.533 11.88% 1 28 0 28 1 40 40.00 35A INTERCONNECTION SYSTEM SIZE:8000W CONDUCTOR AMPACITY CALC'S: MODULES: JUNCTION BOX TO AC COMBINER BOX: AC COMBINER BOX TO POINT OF INTERCONNECTION: (20)SOLARIA POWER XT-400R-PM EXPECTED WIRE TEMP.(C):50 EXPECTED WIRE TEMP.(C):28 INVERTER: AMBIENT TEMP.CORRECTION PER NEC 310.15(B)(2)(a):0.82 AMBIENT TEMP.CORRECTION PER NEC 310.15(B)(2)(a):1 ENPHASE IQ8PLUS-72-2-US CIRCUIT CONDUCTOR SIZE:10 AWG CIRCUIT CONDUCTOR SIZE:12 AWG CIRCUIT CONDUCTOR AMPACITY PER NEC 310.15(B)(16):40A SURFACE TYPE:ROOF CIRCUIT CONDUCTOR AMPACITY PER NEC 310.15(B)(16):30A #OF CURRENT CARRYING CONDUCTORS IN CONDUIT:3 #OF CURRENT CARRYING CONDUCTORS IN CONDUIT:4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a):1 AHJ:YARMOUTH TOWN CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a):0.8 CONTRACTOR: REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X MAX.INVERTER OUTPUT CURRENT= `:1.25 X MAX.INVERTER OUTPUT CURRENT= 1.25 X 1.21A X 20 =30.25A ff 1.25 X 1.21A X 10 =15.13A 0;1_2eaZ.4(nn:C DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLES CFP solar :`:: home DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLES TEMP.CORR.PER NEC 310.15(B)(2)(a)X ADDRESS 92 GROVE STREET,GLOUCESTER,MA01930 TEMP.CORR.PER NEC 310.15(B)(2)(a)X CONDUIT FILL CORR.PER NEC 310.15(B)(3)(a)X PHONE:BTB 2B1d626 CONDUIT FILL CORR.PER NEC 310.15(B)(3)(a)X CIRCUIT CONDUCTOR AMPACITY PER NEC 310.15(8)(16)= PROJECT NAME: CIRCUIT CONDUCTOR AMPACITY PER NEC 310.15(6)(16)= 1 X 1 X 40A=40A LAGREE,SUSAN 0.8 X 0.82 X 30A=19.68A CONDUIT SIZING: PROJECT ADDRESS: AC COMBINER BOX TO POINT OF INTERCONNECTION: 46 SQUIRREL RUN ST., JUNCTION BOX TO AC COMBINER BOX: CIRCUIT CONDUIT SIZE:3/4"FMC/EMT YARMOUTH PORT,MA 02675 CIRCUIT CONDUIT SIZE:3/4"FMC/EMT TOTAL INTERNAL AREA OF CONDUIT:0.533 SQ.INCH TOTAL INTERNAL AREA OF CONDUIT:0.533 SQ.INCH TEL.t 978-501-3680 APN VA.11,101”1.0.710000 CIRCUIT CONDUCTOR SIZE:10 AWG THWN-2 JOB NUMBER:11769 CIRCUIT CONDUCTOR SIZE:12 AWG THWN-2 APPROXIMATE AREA OF CONDUCTOR:0.0211 SQ.INCH DRAFTER: APPROXIMATE AREA OF CONDUCTOR:0.0133 SQ.INCH AS PER NEC TABLE-1,CHAPTER 9: REVISION HISTORY AS PER NEC TABLE-1,CHAPTER 9: #OF CONDUCTORX AREA OF CONDUCTOR=<40%OF REV DESORPTION DRW DATE #OF CONDUCTORX AREA OF CONDUCTOR=<40%OF AREA OF CONDUIT 0 DRAFTER REVIEW AU 10-05-22 AREA OF CONDUIT 3 X 0.0211 SQ.INCH< 0.4 X 0.533 SQ.INCH 1 COMMENTS INCORPRATED NN 10-18-22 4 X 0.0133 SQ.INCH< 0.4 X 0.533 SQ.INCH 0.0633<0.2132 2 COMMENTS INCORPRATED AR 10-29.22 0.0532<0.2132 1 a S 6 Inverter Specifications 7 Branch 1 Branch 2 Total 8 (10)ENPHASE (10)ENPHASE Main.Panel Connection SHEET IQBPLUS-72-2-US IQ8PLU5-72-2-US _ - ELECTRICAL CALCS Max AC Power 2900 W 2900 W 5800 WMain Bus Rating 200 A Main Solar Breaker Size Max AC Current 12.10 A 12.10 A 24.20 A Main Bus X 120% 240 A Main Solar Breaker size 35 A REV:2 Max AC Current X 1.25 15.13 A 15.13 A 30.25 A Main Breaker Rating 200 A Breaker less than max feed? OK PAGE PV-5.0 Solar Breaker Size 20 A 20 A 35 A Maximum Solar Feed 40 A REQUIRED SIGNAGE: A WARNING © PHOTOVOLTAIC DC DISCONNECT ELECTRIC SHOCK HAZARD RATED MAXIMUM POWER-POINT CURRENT: DO NOT TOUCH TERMINALS. O RATED MAXIMUM POWER-POINT VOLTAGE: 0 TERMINALS ON BOTH LINE AND MAXIMUM SYSTEM VOLTAGE: LOAD SIDE MAY BE ENERGIZED MAXIMUM CIRCUIT CURRENT: IN THE OPEN POSITION SYSTEM SIZE:8000W MODULES: A WARNING A PHOTOVOLTAIC AC DISCONNECT (20)SOLARIA POWER XT-400R-PM ELECTRIC SHOCK HAZARD MAXIMUM AC OPERATING CURRENT:24.2 A 7 INVERTER: ENPHASE IQ8PLU5-72-2-US THE DC CONDUCTOR OF THE PV O NOMINAL AC OPERATING VOLTAGE:240V SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SURFACE TYPE:ROOF PHOTOVOLTAIC DC DISCONNECT O AHJ:YARMOUTH TOWN AWARNING A CONTRACTOR ELECTRIC SHOCK HAZARD O SOLAR DISCONNECT O S: 'er.. -`: IF A GROUND FAULT IS INDICATED, //��� NORMALLY GROUNDED CONDUCTORS MAY l - Q eaaCt BE UNGROUNDED AND ENERGIZED WARNING: 1 O ��•// Cr'-solar& home PHOTOVOLTAIC POWER SOURCE ADDRESS:02 GROVE STREET.GLOUCESTER.MA 01930 ® WARNING ® NOTE:REFLECTIVE LABEL REQUIRED EVERY 10FT. DC SIDE AC SIDE PHONE 9T&291d825 PHOTOVOLTAIC SYSTEM EQUIPPED PROJECT NAME: INVERTER OUTPUT CONNECTION OR w DO NOT RELOCATE THIS WITH RAPID SHUTDOWN SYSTEM z (AGREE,SUSAN w OVERCURRENT DEVICE u) a PROJECT ADDRESS: PHOTOVOLTAIC SYSTEM 12 H- a ct z 46 SQUIRREL RUN ST., ® WARNING A, kWh METER x F v YARMOUTH PORT,MA 02675 0 DUAL POWER SUPPLY O w CD W w O w o w Z El.#: 978-501-3680 APR 9:.MMM,=, , SOURCES:UTILITY GRID AND z z Z o w JOB NUMBER:11769 PV SOLAR ELECTRIC SYSTEM z m 0J Ov > w 0 Z U w 0 DRAFTER: J O Z N W D m p Tn F- w0 0 w 0 U w 0 O Z Z Q O O O U i "4O F' REVISION HISTORY SIGNAGE REQUIREMENTS J Z a 8 0 a a CODE REFERENCES(NEC) REV DESCRIPTION DRW DATE 1 X X X X 690.17(E) 0 DRAFTER REVIEW AH 10-05-22 1. RED BACKGROUND 1 COMMENTS INCORPRATED NN 10-10-22 2. WHITE LETTERING 2 X X X 690.35(F) 2 COMMENTS INCORPRATED AH 10-29-22 3. MIN.3/8"LETTER HEIGHT 3 X 690.5(C) 3 4. ALL CAPITAL LETTERS 4 X X X 705.12(D)(2)(b) 5. ARIAL OR SIMILAR FONT 5 X X 705.12(D)(3) 5 6. WEATHER RESISTANT PER UL 969 6 X 690.53 6 7 X X X 690.54 s 8 X X 690.13(B),IFC 605.11.3 SHEET 9 X X 690.13(B),IFC 605.11.3 SIGNAGE 10 X 690.31(G)(3),IFC 605.11.1.2 REV:2 11 X X 690.56(C) PAGE 12 PV-6.0 CAUTION SYSTEM SIZE:8000W MODULES: (20)SOLARIA POWER XT-400R-PM INVERTER: POWER TO THIS BUILDING IS ALSO SUPPLIED ENPHASEIQ8PLUS-72-2-US FROM THE FOLLOWING SOURCES WITH SURFACE TYPE:ROOF DISCONNECTS LOCATED AS SHOWN- AHJ: YARMOUTH TOWN CONTRACTOR: Sll ii M eaaeaET uQf PV•RRAY• ••• solar hom IC:O INVE'TER \ . I ADDRESS 02G PHHONEBB-281i8 SESTER.MA 01930 N N PROJECT NAME: �: LAGREE,SUSAN _ ce w PROJECT ADDRESS: 3 ct 46 SQUIRREL RUN ST., MN ? N YARMOUTH PORT,MA 02675 EE TES.e: 978-SO1-3680 APN x:+" JOB NUMBER:11769 DRAFTER: AC COMBINER BOX INTERIOR SMART METER EXTERIOR UTILITY METER(EXTERIOR) REVISION HISTORY AC DISCONNECT EXTERIOR MAIN SERVICE PANEL(INTERIOR) REV DESCRIP0ON DEW DATE 0 DRAFTER REVIEW AR 10-05-22 1 COMMENTS INCORPRATED NN 10-18-22 2 COMMENTS INCORPRATED AR 10-29-22 3 4 .. -__- 5 6 7 8 SHEET PLACARD REV:2 PAGE PV-6.1 SOLARIA Solaria PowerXT'''I DC Panel SOLARIA Solaria PowerXT°-400R-PM oi SYSTEM SIZE:8000W fi. Performance at 5It(1000W%m',25"C.AM 1.54 Mechanical characteristics MODULES: 2 Solaria PowerXT- a0ae-PM Cell Type Mon0crysreIIme Silicon _la Max Power(P,na,) IWI 400 Dimensions(LxWxH) 64J1'xa74'xts7" (20)SOLARIA POWER XT-400R-PM ty,S'+. Efficiency I%) 20.2 1644mm x 1204mm x 40mm -- (I'�a Open Circuit Voltage(V.) WI 51.1 Weight 21 kg/46lbs INVERTER: (,. a"' Short Circuit Current(lu) IA) 9.82 Glass Type/Thkkness ARCoated.Tampered/2.84mm iay.fir`" Frame Type Black Anodized Aluminum ENPHASE IQ8PLUS-72-2-US • Max Power Voltage(Vren) IVJ 42.4 Cable Type/Length 12 AWG PV Wire(UL)/t000mm Solana PowerXT'-400R-PM Max Power Current(I,) IAi 9.4i Power Tolerance NI .p/.3 Connector Type MC4 Junction Box IP67/4 diodes SURFACE TYPE:ROOF Performance a,50111S00Vi;In,20'C Amb,Wind 1 m/s)AM 1.5) Front Load 5400Pa/113 ps1• - Achieving over 20%efficiency,Solaria PowerXT solar panels are one of the highest power panels in the residential and commercial solar Max Power(Pmax) DV) 295 Rear Load 2400 Pa/50 pal. AHJ:YARMOUTH TOWN market.Compared to conventional panels.Solaria PowerXT panels have fewer gaps between the solar cells;this leads to higher power Open Circuit voltage(va) IV) 48.t - and superior aesthetics.Solaria PowerXT Pure Black'panels are manufactured with black backsheet and frames,enhancing a home or Short Circuit Current(lao) IA) 7.92 a.rw rn saia�„ro"w.ia^a..vn rw ar.�. CONTRACTOR: building's architectural beauty. Max Power Voltage(Vmp) IV] 40.0 Certifications UL 61730/UL1741/CEC •^ Max Power Current(I,no) IAI 7.59 .. CAN/CSA-C22.2 Fire Type Qe'Q(AL 1703) 1 "'- • 1 Higher Efficiency,Higher Power NKr I°CI 45 4/2 Warranty 25years. ( uC( Solaria PowerXT panels achieve over 20%efficiency;conventional panels achieve 15%- Temp.Coetf.of P.., 1%/°CI -0.39 'w"inj°"a0it wx"ip1spign & �t 17%efficiency.Solaria PowerXT panels are one of the highest power panels available. Temp.C .of Vrc 1%/C -0.29 Packaging soar hf3ia r, Temp.Cacactf. ' ti.of lac 1%/CI 0.04 Stacking Method Horizontal I Palletized ADDRESS-92 GROVE STREET,GLOUCESTER,MA 01930 Lower System Costs Design Parameters Panels/Pallet 25 PHONE9782914626 Solaria PowerXT panels produce more power per square meter area This reduces Operating temperature I°C) -40 to v85 Pollee Dims(L x w x H) 66.57'x 48.7'x 48.4' Max System Voltage Iv) 1000 1691mm x 1238mm x1230 ram PROJECT NAME: installation costs due to fewer balance of system components. Pallet Weight 590 kg/1300 lbs Max Fuse Rating IAI 20 Pallets/dOft Container 16 LAGREE,SUSAN Improved Shading Tolerance Bypass Diodes Irl 4 Panels/40-ft Container 450 Sub-strings are interconnected in parallel,within each of the four panel quadrants, IV Curves vs Irradiance(400W Panel) -- }„•wa, -- PROJECT ADDRESS: which dramatically lowers the shading losses and boosts energy yield. _— �-, • • 46 SQUIRREL RUN ST., Improved Aesthetics .-- 9 YARMOUTH PORT,MA 02675 Compared to conventional panels,Solaria PowerXT panels have a more uniform appearance and superior aesthetics. ' ._ _._____-__ ...__ TEL.w: 978-501-3680 APN x:.Aawaelawm°nrman • 6..!. JOB NUMBER:11769 Durability and Reliability i., Solder-less cell interconnections are highly reliable and designed to far exceed ' DRAFTER: be industry leading 25 year warranty • . ��. REVISION HISTORY REV DESCRIPTION DIM DATE ^'"�''""^- ~'- wf"'�"g"•' 0 DRAFTER REVIEW AH 10-05.22 75-ye8i Power,Perta and Lesorrnr,Wade i (imml — 1 COMMENTS INCORPRATED NN 10-18-22 r' I T 1 Industry warranty II About Solaria 2 COMMENTS INCORPRATED AH 10-29-22 Established in 2000,The Solana Corporation has created one of the industry's most respected KAAaeEon e. w ' ~1=4 3 IP portfolios,with over 250 issued and pending patents in PV solar cell and module technology. (74'''' 1 A. I � Ia Headquartered in Oakland,California,Solaria has developed a technology platform that I ff�i�� - o s unlocks the potential of solar energy. 000R1'°I"L"okii T�°�,^ 6 ae..nan uvucwo n.•rrew. veers FRAME PROFILE 7 The Spina Corporation 1700 Broadway.Oakland,CA94611 P.(510)270-2507 www.solaria corn Copyright C 202D The Solaria Corporation The Solaria Corpaaeon 1700 Broadway,Oakland.CA94611 P.(510)270 w.1507 wwsolaria cam Copyright 02020 The Solaria Corporation B Produn specifications are subject to change without notice. SOL-64r-0005 Revel 4-2020 Product apeclecanons aresubleet to change without notice. SOL-OAI-0005 Rev 01 4-2020 SHEET MODULE DATASHEET REV:2 PAGE PV-7.0 . • EN PHASE ® IQ8 Series Microinverters Commonly used module pelrings' w 235-350 235-440 260-480 295-500 321 Module compatibility 60-ce11/120 half-cell 60-ce11/120 hall-cell,66-cell/132 half-cell and 72-cf iePPT voltage range V 27-37 29-45 33-45 36-45 y Operating range 8 25-48 25-58 Min/max start voltage v 30/48 30/58 Max input DC voltage v 50 60 Max DC current'[module No] A t5 SYSTEM SIZE:8000W P. Overvoltage class DC port II MODULES: ;4 • DC port backfeed current m. 0 (20)SOLARIA POWER XT-400R-PM Ell M PV array configuration Ind Ungrounded array;No additIonal DC side protection required:AC side protection requir INVERTER: Ir. ' '` ._ '"" ENPHASEIQ8PLUS-72-2-US -• I P Peak output power VA 245 300 330 368 Max continuous output power VA 240 290 325 349 Nominal(L-L)voltage/rangev 240/211-2e4 SURFACE TYPE:ROOF Max continuous output current A 1.0 1.21 1.35 1.45 AHJ:YARMOUTH TOWN Nominal frequency 0 60 CONTRACTOR: IQ8 Series Microinverters Extended frequency range a+ 50-68 Easy to install - y.L AC short circuit fault current over 2ee1k �.►%;. Our newest 108 Microinverters are the industry's first microgrid-forming,software- •Lightweight and compact with 3cycles Arms ^ ,-,,.--- defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors Max units per 20A(L-U branch circuit'. 16 13 n 11 / �,ly�p�llr u/J f power to AC power efficiently.The brain of the semiconductor-based microinverter -Power Line Communication `v_M. �+vL G Is our proprietary application-specific integrated circuit(ASIC)which enables the rote)Harmonic distortion <s% (PLC)between components owrvoitage class AC port III solar& home microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced •Faster installation with simple ADORE&9:@GROVE BTREET,1-eelsE87ER,MA 01930 55nm technology with high speed digital logic and has super-fast response times AC port backfeed current mA 30 PHONE:97&281-4625 to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling Power factor setting to PROJECT NAME: energy systems. High productivity end reliability Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging •Produce power even when the Peek efficiency 5 97.5 07.6 97.6 97.6 LAGREE,SUSAN Enphase grid is down* CECweightedeinciency , 97 97 97 97.s PROJECT ADDRESS: •More than one million cumulative Nigh-time power consumption mw 60 hours of testing 46 SQUIRREL RUN ST„ •Classlldouble-insulated Ambient temperature range -40.Cto.30oC(-40°Fto•140°F) YARMOUTH PORT,MA 02675 Part of the Enphase Energy System.108 Series 108 Series Microinverters redefine reliability enclosure Relative humidity range 4%to 100%(caldenel ) TEL.N: 978-501-3Fi80 APN#.1.1.0401.0038.13E0^9 Microinverters integrate with the Enphase lO Battery, standards with more than one millioncumulatloe •Optimized for the latest high- DC Connector type MCI Enphase lO Gateway.and the Enphase App monitoring hours of power-on testing.enabling an industry- JOB NUMBER:11769 and analysis software. leading Dented warranty of up to 25 years. powered PV modules Dimensions(H.W.D) 212 nun(8.3')x 175 min(8.9')a 30.2 min 021 Weight 1.034(2.381W DRAFTER: Mlcrogrid-forming Cooling Natural convctlon-no tans V) •Complies with the latest Approved foreg wet locationsec REVISION HISTORY advanced grid support" REV DESORPTION DRW DATE •CERTIFIED Pollution a.gnee PD3 Remote automatic updates for o DRAFTER REVIEW All 104M-22 WO FLY the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric antics 1 COMMENTS INCORPRATEO NN 10-18-22 Connect PV modules quickly and easily to 108 Series 108 Series Microinverters are UL Listed as Environ.category/UV exposure rating NE MA Type 6/outdoor 2 COMMENTS INCORPRATED All 10-29-22 Microinverters usingthe included 0-DCC-2 ed. PV Rapid Shut Down Equipment and conform with •Configurable to supportawide per pi peen range ofgrid profiles 3 cable with dug-n-pisy MC4 connectors. various regulations.when installed according to 9 p 4 manufecturer'einetructlon.. •Meets CA Rule 21(UL 1741-SA) Cu Rule 21(UL 1741-SA).UL 62109-1.UL1741/IEEE1547.FCC Pert 15 Class B.ICES-0003 Class I 5 requirements Certifications This product A UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 6 690.12 end C22.1-2018 Rub 64-218 Rapid Shutdown of PV Systems,for AC and DC conductor 7 manufacturers Instructions. 02022 Enphase Energy.Al rights reserved.Enphase.the Enphase logo,108 Mkrolnverters.and other •Only when Installed with 10 System Controller 2.meets (1)The10811-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See 8 names are trademarks of Enphase Energy.Inc.Data subtect to charge. UL 1741.10811-208V operates only in grid-tied mode. the compatibility calculator at https://link.enphase.com/module-canpatlbility(3)Maximum continuous input SHEET ••Io8 Sense Mlctoinvetters supports split phase.240V. DC current u 10.6A(4)Nominal voltage range can be extended beyond nominal If required by the utility.(5) INVERTER DATAS H E ET IO8SE-DS-0001-D1-EN-US-2022-03-17 1086-208 supports split phase.208V only. Limits may vary.Refer to local requirements to define the number of microinvertete per branch In your area. l08! REV:2 PAGE PV-7.1 Enphase IQ Combiner 4/4C G9t3 Sheet MODEL NUMBER Enphase Networking to Combiner(x-10 AMn2+o-4) C12.0b NwIandconsumption l +2plinlmonyoring(W.2uaboeclod integratedarsolar hie lO e PV ow.the IC Battery system steANSI 10 S M.C.SY)and 2 and topdflectheat ng(a/]SY),Includesas,lver solar shield to match the IC Bsnery ryslemarM IQ System Controller 2endtotlnflM neat IQ Combiner 4C(x-1Q-AM1240-4C) 10 Combiner 4C with Enphase lO Delewry printed circuit board for integrated revenue gradePV production metering (ANSI C12.20+/.0.5Y)and consumption monitoring(+/.2.51.).Includes Enphase Mobile Connect cellular modem _- (CELLMOOEM-M1-06SP-05),a plug-end-play IndusMel-grade cell modem for systems up to 60 mkrol,wa,iers. (Available In the US.Canada,Mexico,Puerto Rico,end the US Virgin Islands,where bete Is edequete cellular service In Enphase The Enphase IQ Combiner 4/4C with Enphase me ne. ua«ea)Esludaeasilw,r¢mar salald to match Mel0 Battery endl05ystem Controller and to deflect heal SYSTEM SIZE:8000W IQ Safeway and integrated LTE-Mt cell ACCESSORIES AND REPLACEMENT PARTS (not incl c d tl saps t ly) __..._ oleelCLLM00EM-M1.63F-0swbn5 -"—__pl .__ MODULES: IQ Combiner 4/4C Ensemble C Ian.Nit IncludesCOMM,. Sprint plan for modem(included only with IQ Combiner 4C) COMMS-CELLMODEM MT06 Ensemble sit. CELLM00EMM1065P-05 4G based LTEM Ilular modernwilh5-yea Sprint data plan (20)SOLARIA POWER XT-400R-PM X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-61 06AT05 -4G Wised LTE-M1 cellular modern with 5-year AT&T data plan X-IQ-AM1-240 4C ebe.10A.2-era Support EatonBR21D,aR215,BR220,BR230,BR240.BR250.andBROWcircuitbreakers INVERTER: into a single enclosure and streamlines(0 BRNt0A4-2a0V Circuit breaker,2po.,tOA.Eaton 8R210 5R14-15A-2-240V Circuit breaker,'pole,15A,Eaton 1311215 ENPHASE I Q8PLUS-72-2-US microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2 pole.20A.Eaton eR220 1311K-15A-2P-240V.B Circuit breaker,2 pole.05A,Eaton imam with hold down On support providing a consistent,pre-wired solution for BRK-20A-2P-240V-0 Clrcult breaker,2 P018.20A,Eaton 8112206 with hold down kit support residential applications.It offers up to four EPLC-01 Power line career(commonlcsaoebridgepew).quamny-one pair SURFACE TYPE:ROOF xA-SOLARSHIELD.ES Replacement solar shield for 10 Combiner 4/4C 2-pole Input circuits and Eaton BR series XAPLUG-120.3 Accessory receptacle for Power Line Carrier In 10 Combiner 4/4C(required for EPLC-01) AHJ:YARMOUTH TOWN busbar assembly. XA-ENV-PCBA-3 Replacement o Gateway primed circuit board(PCB)Mr combiner 4/4C CONTRACTOR: ;Y`i X-i NA.H0,125A Hold down kO for Eaton circuit breaker with screw¢. ry ELECTRICAL SPECIFICATIONS ---__,---_- ---__,--_`-___`_,___.-.- �.: , • S i'.. Smart Rating __--._ Continuo.MST `_� •Includes IQ Gateway for communication and control System voltage 120/240 VAC,ao Hz •Includes Enphase Mobile Connect cellular modem Eaton BR aeries briber rating 125A ( — a ea iQE (CELLMOOEMM1-06-SP-05),included only with IQ Max.continuous curremtadog 65A `•/ solar & home Combiner4C Mex 000Snuous currmuekq(xgNlrom PW.lorape) 6+A •Includes solar shield to match Enphase IQ Battery Max.fuse/circuit rating(output) MI ADDRESS-92 GROVE STREET,GLOUCESTER,MA 01930 ---a... aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four'Tole Eaton BR series Distributed Generation(DG)breakers only(not Included) PHONE:978-201.4625 ii ' •Flexible networking supports WI-Ff, Mex.total branch circuit Meeker rating(input) generalion y Ethernet,or cellular 6n BOA of distributed /gsA with locaws breaker included PROJECT NAME: Production metering CT 200 A solid core pre-Installed end wired to lO Getaway •Optional AC receptacle available for PLC bridge•ii*f •A; Provides production metering and consumption monitoring CT(CT-200.SPLIn A pair of 200 Aspat on,currant transformers LAGREE,SUSAN monitoring MECHANICAL DATA Dimena.na(Wors0) -T-_ -------�375 x 995 x 16 B cm(1425 1.5 46.631.fleigli Is 21.06'(53.5 m)with mounting breckals PROJECT ADDRESS: Simple Weight go65.$) 46 SQUIRREL RUN ST., Ambient temperature range -40°C to a464C(.40°10 115.E) fl' •Centered mounting brackets support single Cooling Naw,eiporweeton,plus heat shield YARMOUTH PORT,MA 02675 stud mounting• Enclowre environmental wins Outdoor,NOTE-tensed.NEMF type 3R-poNceroonare construction•supports bottom,back and side conduit entry A wire sties •20 A 10 50 A breaker inputs la to 4 AMC copper conductors TEL.a: 978-$01-3680 APNa'.vwwN�A�•Up colour 2-pole branch circuits for 240 VAC •60 Abreaker branch input 4to 1/0 AwG cooper conductors • II • plug-In breakers(not included) •Melot com bined JOB NUMBER:11769 XAQ-AMl 240-4C •80A total PV or storage branch circuits •Neutral end ground 14 to 1/0 Copper conductors Always follow local code requirements far conductor suing. DRAFTER: Mir Altitude To 2000 meters(6,560 MO Reliable INTERNET CONNECTION OPTIONS •Durable NRTL-certified NEMA type 3R enclosure Integrated wi FI eui nbyp/n REVISION HISTORY •Elva-yoat limited warranty Cellular CELLMOOEM.M1-06.5P-05.CELLMOOEM-M1-06-AT-05(4G based cellular modem).Note that an Enphase REV DESCRIPTION DRW DATE Mobile Connect cellular modern Is required lot all Ensemble Estnlienions. •Two years labor reimbursement program coverage Ethernet Optional,0033.cans(or Cat 6)UTP Ethernet cable(not included) 0 DRAFTER REVIEW AH 10.0$-22 Included for both the IQ Combiner SKU's COMPLIANCE 1 COMMENTS INCORPRATED NN 10-18-22 •Ul listed �_ Compliance,IQ combiner UL 1741,CAN/CSA C22.2No.1071,47 CFR,Pan5,Class B.ICES 003 2 COMMENTS INCORPRATED AU 10-29.22 Production mamba.mai ct22ry 0e class 0.5(PV production) 3 Consumpton mewing: elm 2.6 2.5 _O Compliance.IQ Gateway LP 60601-1/CANCSA222 No.61010-1 4 To learn more about Enphase offerings,visit anpheso0som E N PH A S E To learn more about Enphase offerings,visit enuisaga roID C.N P H AS E 02021 051040e Energy ace,igbss,eserved Enphase the enpnase loge.IV Conxwrer 414C.and mat names are trademarks of Enphase Energy,Inc.Dela sublw'l Is Mange.10,21 2021 a SHEET ENPHASE IQ COMBINER REV:2 PAGE PV-7.2 IRONRIDGE Roof Mount System IRON RIDGE Engineering Design Guide System Parts XR1000 Rail SYSTEM SIZE:8000W XR1000 is a heavyweight among solar rnounbng rails,built to handle extreme climates and spans 12 feet or more for commercial applications. MODULES: Property Value (20)SOLARIA POWER XT-400R-PM r: L., Material 6000 Series Aluminum `htx, noun aearA Anodized d INVERTER: '' i 9 i .y Beam Height 3.00' ENPHASEIQ8PLUS-72-2-US Weight/Linear Foot 0.945 Lbs Total Cross Sectional Area 0,8071n. I Section Modulus(X-axis) 0s30m' SURFACE TYPE:ROOF Moment of Inertia(X-axis) 0.8431n "Ye�allar6�y Moment of Inertia(Y-axis) 0.1821n AHJ: YARMOUTH TOWN Torsional constant 0.4361n CONTRACTOR: Polar Moment of Inertia 0.3299In I XR100 Rail XR100 Is the ultimate residential mounting rail.h supports a range of wind and snow mrdtlonS,while also maxfizing spans (a�e a u Q E Property Valoe solar a. home Material 6000 Series Aluminum Finish Ckar 8 Black Anodized ADDRESS.92 GROVE STREET,GLOUCESTER.MA 01930 PHONE:97B-281-525 Built for solar's toughest roofs. Beam Height 2.44 weighuunearFoot o.68Lbs PROJECT NAME: Anchored by the strongest rails in solar,the IronRidge Roof Mount System provides the durability and - ---- Total Cross-sectional Area ose2 In' versatility to handle virtually any residential or commercial rooftop. Section Modulus(X-axis) 0.297In' LAGREE,SUSAN The unique curved profile of the XRS Rail increases its strength while also giving it an attractive look,making sWlWyy ,wu. Moment of Inertia(X-axis) 0.3901n' it very customer-friendly,In addition,IronRidge Rails are certified for integrated grounding,which eliminates Moment of Inertia(Y-axis) 0.085 In' PROJECT ADDRESS: separate module grounding components and procedures,making it very installer-friendly. Torsional Constant 0.214 In' Polar Moment of Inertia 0.1261n 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 Strongest Rails PE Certified XR10 Rail p TEL.a: 978-501-3680 APN P:....,xwramcommm al Longer spans between attachments, v Pre-stamped engineering letters XR10 is a low-profile mounting rau,perfectly matched to woos with light snow.ft achieves a Not spena,whue staying light and economical. fewer roof penetrations. available in most states. JOB NUMBER:11769 Property Value Material 6000 Series Aluminum DRAFTER: Simple Assembly Design Software Finish Clear Anodized Beam Height 1.75' © Versatile and adjustable components Online tool generates a complete bill weight/linear Foot 0.436 Lbs REVISION HISTORY simplify any array design. of materials in minutes. - - - - _.. Total Cross-Sectional Area 03fi31n' REV DESCRIPTION DRW DATEI Section Modulus(X-axis) 01361n' 0 DRAFTER REVIEW AH 10-05-22 aelialla --% Integrated Grounding 20 Year Warranty Moment of Inertia(X-axis) 0.124In' 1 COMMENTS INCORPRATEO NN 30-18-22 O-�- Moment o(Inertia(Y-axis) 0.0321n' 2 COMMENTS INCORPRATED AH 30-29-22 UL 2703 system eliminates separate Twice the protection offered by Torsional Constant 0.0761n' 3 module grounding components. competitors. Polar Moment of Inertia 0.033In' 4 5 • 6 supporta I Ironhdge.com I (B00)227-9523 PpeS 2014 v1.64 7 s SHEET RACKING DATASHEET REV:2 PAGE PV-7.3 Tech Brief IRON RIDGE UFO Family of Components System Diagram Simplified Grounding for Every Application • 4 3 SYSTEM SIZE:8000W The UFO family of components eliminates the need for —_ MODULES: separate grounding hardware by bonding solar modules a iiir (20)SOLARIA POWER XT-400R-PM directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground INVERTER: Mount—are fully listed to the UL 2703 standard. El 0 0:--m-_:0 0 4 TA ENPHASE IQ8PLUS-72-2-US UFO hardware forms secure electrical bonds with both the module and the rail,resulting in many parallel grounding paths throughout the system.This leads to safer and more SURFACE TYPE:ROOF reliable installations. AHJ:YARMOUTH TOWN .—_ �— �':) O--:CO:_---o 0 • II' CONTRACTOR: 41: .A Stopper Sleeve The Stopper S Universal Fastening'Dialect(UFO) — /� .... ..- Sleeve snaps onto the UFO,convertingThe UFO securely bonds solar modules to XR \( �)_ a intoRails.It comas assembled and lubricated,end V eQ^�� aborbed end dan,p. oanlnewderengaminadwerreghn. _:► o o--_m==—o 0 _ �= solar & home 111114. \�'•� ADDRESS.92 GROVE STREET,GLOUCESTER,MA 01930 PHONE.978-2e1-4e25 PROJECT NAME: 0 UFO 4 Stopper Sleeve •Grounding Lug m Bonded Splice Ground Wire _ LAGREE,SUSAN /f ." PROJECT ADDRESS: �• $'O 2 Approved Enphase microlnverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the 46 SQUIRREL RUN ST., same rail end connected to the same Engage cable is required.Refer to installation manuals for additional details. YARMOUTH PORT,MA 02675 TEL.k: 978-501-3680 APN k..aw Certification . „ JOB NUMBER:11769 �i»,�n� UL Certification '. ', The IronRidge Flush Mount, Fi 11 tUi Flt..I Mot nt Tilt Mount Ground Mount `. ^ rs �. Tilt Mount,and Ground Mount �Rags V V XR10000ny DRAFTER: --- -- Bonded Splice Systems have been listed to UL Each Bonded Splice uses "-1L 2703 by Intertek Group plc. . UFO/Stopper d W' vr sell-drilling screws to form ' - a sere connecl .No �' G•+" � Bonded Splice _ _ REVISION HISTORY secure wn nondng strap needed. - , UL 2703 is the standard for .NIA REV DESCRIPTION Ilaw DATE / evaluating solar mounting Grounding lugs 1 per Row 1 per Row 1 per Array - 0 DRAFTER REVIEW AH 1005.22 systems.It ensures these devices 1 COMMENTS INCORPRATED NN 10-10-22 Mlerolnverters Enphase-M250-72,M250-60,M215-60,C250-72 will maintain strong electrical and &Power Dadon-MIG240,MIG300,G320,G640 2 COMMENTS INCORPRATED AH 10-29-22 - eA, A s Lug Bonded Attachments mechanical connections over Optimizers SolarEdge-P300,P320,P400,P405,P600,P700,P730 3 44.-wi an extended period of time in � ea -- 4 : connects an enure row The bonding boltenach Fire RatingClass A Class A N/A of PV modules to the are bonds the L-loot to the extreme outdoor environments. 5 grounding conductor. raft It Is Installed with theTested or Evaluated with over 400 Framed Modules sera selet es the meetly Modules s Nee a Go to IronRidge.00m/UFO L. Refer to installation manuals fora detailed list. 7 a SHEET UFO DATASHEET REV:2 PAGE PV-7.4 IRONRIDGE FlashFoot2 2)Assy,Flashing II j 0 9.0 SYSTEM SIZE:8000W ,`` - \ MODULES: 0 / \ (20)SOLARIA POWER XT-400R-PM T. INVERTER: I - - -1 0 ENPHASE IQ8PLU5-72-2-U5 0 19-1_ SURFACE TYPE:ROOF O/� _ _ t AHJ:YARMOUTH TOWN /6 _ I _ CONTRACTOR: d (2:D PrePelTYvan. ----w.,....Y.� Material Value "� `- 'eft. ': Rneh MR/Block 4� ea�eauCf REM NO. DESCRIPTION Oily In Kitsolar home ADDRESS:92 GROVE STREET,GLOUCESTER,MA 01530 1 BOLT LAG 5/16 X 4.75" 4 PRONG 9]8-81J825 2 ASSY,FLASHING 4 3 ASSY,CAPFOOT 4 PROJECT NAME: 4 WASHER,EPIDM BACKED 4 3)Assy,Capfoot 4)Washer,EPDM Backed LAGREE,SUSAN FLASHFOOT2 .40-.1 I I PROJECT ADDRESS: - I 46 SQUIRREL RUN ST., Part Number Description1s6 0.35 --•- Fo--.14 YARMOUTH PORT,MA 02675 F-FF2-001 it,Ip s, ashF oot2 IMilllI TEL.R: 978-501-3680 APN R:vuslwa>.moruom FM-FF2-001.8 KB,4pes,RashFoo121BeckJ 33 Q JOB NUMBER:11769 DRAFTER: 1)Bolt,Lag 5/16 x 4.75 0.75 4 26 _1 5/16 THD Oi,b3 '1 REVISION HISTORY I•i a Propel* Vane Property Vane REV DESCRIPTION OIIW DATE 7/16" 0 GRAFTER REVIEW AH 10-05-22 Head 4 75 1 Material Aluminum Material 300 Series Stainless Steel Finish Milt/BlackFinish Clear 1 COMMENTS INCORPRATED NN 10-18-22 Properly Value2 COMMENTS INCORPRATED AN 10-29-22 Material 300 Series Stainless Steel a 4 Finish Clear S v1.0 v1.0 6 7 8 SHEET ATTACHMENT DATASHEET REV:2 PAGE PV-7.5 IRON RIDGE Hidden End Cam Easy,Tool-Less Installation A A.PLACE CAMO Slide CAMO into rail track far enough to clear the \-;;;Nt .^p module frame.CAMO requires 6"of clearance from SYSTEM SIZE:8000W Most solar installations use mounting Standard Fastener et� ') end of rail. rails and fasteners to secure modules to the building structure,but these critical MODULES: components often protrude from the sides a (20)SOLARIA POWER XT-400R-PM of the modules,giving arrays a coarse look. INVERTER: B.PLACE MODULE CAMO is an invisible fastener that secures ENPHASE IQ8PLUS-72-2-US solar modules flush to rail ends,creating a Place module on rails and align flush with rail ends 0A1Pilliiiih. clean,sleek appearance.CAMO works with r'. (module cells not shown in image to provide clarity). nearly all solar modules and installs without The module can overhang the rail no more than 1/4". 1- SURFACE TYPE:ROOF tools or torque specifications.It simply rotates into place to structurally secure and AHJ:YARMOUTH TOWN electrically bond with the module. O. CONTRACTOR: --- C.SLIDE CAMO ai" :.; Pull CAMO towards rail end,at a 45 degree angle,so ? //^w A " -. linear bonding pin contacts the module flange edge. ` l — QaeQ uQi qr ✓ V solar & hoi . '>< '' ADDRESS:92 GROVE STREET,GLOUCESTER,MA 01930 D PHONE:978-281-4828 D.SECURE CAMO •ochtc, , PROJECT NAME Rotate handle with an upwards motion until CAMO LAGREE,SUSAN snaps into rail track.Ensure CAMO bonding pins are (-1 fully seated on top of module frame. PROJECT ADDRESS: 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 Cam-Locking Design Tested&Certified TEL.#. 978-501-3680 APN 01 NOMBOODS71.D. UL 2703 JOB NUMBER:11769 ride CAMO into the rail hack and rotatetho - oneo the mod handle ulo ul. �jty o.to lock DRAFTER:` CAMO conforms to STD UL 2703(2015)requirements and fits modules with bottom flanges that meet specifications shown in the frame compatibility diagram on the left. REVISION HISTORY Frame Compatibllty: REV DESCRIPTION DRW DATE See IronRidge Installation Manuals for full ratings and a list of X=1.2-2.2 mm certified compatible modules. D DRAFTER REVIEW AH 10-05-22 Y=15-40 mm 1 COMMENTS INCORPRATED NN 10-18-22 O 2 COMMENTS INCORPRATED Ali 10-29-22 3 Ei1rr � - rvertd a Mprl R i�1 r rI 6 7 8 SHEET HIDDEN END CLAMP DATASHEET _ REV 2 PAGE PV-7.6 BILL OF MATERIALS: BILL OF MATERIAL EQUIPMENT MAKE QUANTITY PICKED RETURNED MODULE SOLARIA POWER XT-400R-PM 20 INVERTERS ENPHASE IQ8PLUS-72-2-US 20 MOUNTING POINTS IRONRIDGE FLASHFOOT 2 58 MOUNTING RAILS IRONRIDGE XR-100 RAILS 14 SYSTEM SIZE:8000W END CLAMPS MODULE END CLAMP STANDARD 32 MODULES: MID CLAMPS MODULE MIDDLE CLAMP SET STANDARD 24 (20)SOLARIA POWER XT-400R-PM AC DISCONNECT 60A RATED NON-FUSED AC DISCONNECT 1 INVERTER: ENPHASE IQ8PLUS-72-2-US SMART METER SMART METER 200A RATED 1 AC COMBINER AC COMBINER BOX-ENPHASE IQ COMBINER+80A 1 SURFACE TYPE:ROOF RATED WITH(2)20A/2P BREAKERS AHJ: YARMOUTH TOWN CONTRACTOR: Ca e el CI ow solar & home ADDRESS.92 GROVE STREET.GLOUCESTER,MA 01930 PHONE 97E4281-1825 PROJECT NAME: LAGREE,SUSAN PROJECT ADDRESS: 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 TEL.#: 978-501-3680 APN#:YAereuoinemenmuo JOB NUMBER:11769 DRAFTER: REVISION HISTORY REV DESCRIPTOR DRW DATE 0 DRAFTER REVIEW AH 10-05-22 1 COMMENTS INCORPRATED NN 10-18-22 2 COMMENTS INCORPRATED All 10-29-22 3 6 7 8 SHEET BILL OF MATERIALS REV:2 PAGE FL-01 SYSTEM SIZE:8000W STRING - 1 5,' MODULES: (20)SOLARIA POWER XT-400R-PM .. INVERTER: ENPHASE IQ8PLUS-72-2-US SURFACE TYPE:ROOF AHJ:YARMOUTH TOWN CONTRACTOR: hiliiiiip eaec�cuQf sour home0 ADORERS'92 GROVE STREET, 1-4825GLOUCESTER.MA 01930 PHONE:92&291L836 PROJECT NAME: IAGREE,SUSAN PROJECT ADDRESS: iiiii 46M SQUIRREL ,MA 02YARMOUTH PORT,MA 02675 TEL.8. 978-501-3680 APR A:MRMewuumn7wmn JOB NUMBER:11769 DRAFTER: RPTIONN HISTORY lift REVDESCRIPTIONDRW DATE 0 DRAKEINC0RR W AN 10-18-22 1 COMMENTS INCORPRATED NN 10.18-22 2 COMMENTS INCORPMTED AH 10-29-22 . 3 STRING - 2 6 2 8 SHEET CREW ROOF PLAN REV:2 PAGE FL-02 J DRAW IN FINAL LOCATION OF EQUIPMENT 1. PANELS 2. STRINGS 3. INVERTER(S) 4. MAIN PANEL 5. SUBPANEL(IF PRESENT) 6. DISCONNECT(IF PRESENT) 7. ROOF ELECTRICAL PENETRATION 8. CONDUIT ROUTES 9. COMMUNICATION WIRE RUNS 10. MONITORING EQUIPMENT SYSTEM SIZE:8000W MODULES: (20)SOLARIA POWER XT-400R-PM INVERTER: ENPHASEIQ8PLUS-72-2-US O SURFACE TYPE:ROOF AHJ: YARMOUTH TOWN CONTRACTOR: �.� °a2eaarCt. sour I hom ADDRESS.92 GROVE STREET.GLOUCESTER,MA 01930 PHONE'.978-281J625 PROJECT NAME: LAGREE,SUSAN PROJECT ADDRESS: 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 0 TEL.It 978-501-3680 APN 0'.r.nonoinwwnme JOB NUMBER:11769 DRAFTER: O REVISION HISTORY REV DESORPTION DRW DATE 0 GRAFTER REVIEW AH 10-05-22 1 COMMENTS INCORPRATED NN 10.18-22 2 COMMENTS INCORPRATED AR 10-29-22 3 a 5 6 7 8 SHEET AS BUILT REV:2 PAGE FL-03 Inverter ZigBee Sticker MOUNTING PITCH TRUE ROOF TYPE ROOF #OF MAPPING INSTRUCTIONS: PLANE AZIMUTH STORY MODULES Model 1. REMOVE THE'SQUARE'OPTIMIZER OR ENPHASE STICKER AND PLACE ASPHALT MP-Ol 28" 105" SHINGLE ONE 20 NEATLY ON THE APPROPRIATE NUMBERED SPACE. Serial# 2. WRITE THE CORRESPONDING NUMBER ON THE APPROPRIATE PANEL WITHIN THE ARRAY. 3. ATTACH THE SQUARE INVERTER STICKER(AND ZIGBEE STICKER IF #of Modules I REQ'D)IN SPACE PROVIDED. per String: String Information String 1 Panel 1-10 SYSTEM SIZE:8000W String 2 Panel 11-20 MODULES: (20)SOLARIA POWER XT-400R-PM INVERTER: ENPHASEIQ8PLUS-72-2-US SURFACE TYPE:ROOF AHJ:YARMOUTH TOWN CONTRACTOR: 1 2 3 4 5 6 7 8 9 10 11 ( ataeQuGf V au-solar& home ADDRESS:92 GROVE STREET,GLOUCESTER.MA 01930 PHONE:978-281d625 PROJECT NAME: LAGREE,SUSAN PROJECT ADDRESS: 12 13 14 15 16 17 18 19 20 46 SQUIRREL RUN ST., YARMOUTH PORT,MA 02675 TEL.9. 978-501-3680 APN 9:VARuw.2uum7.0E0 JOB NUMBER:11769 DRAFTER: REVISION HISTORY REV DESCRIPTION DRW DATE 0 DRAFTER REVIEW AH 10.05-22 1 COMMENTS INCORPRATED NN 10-18-22 2 COMMENTS INCORPRATED AH 10-29-22 3 4 5 6 7 8 SHEET MICRO INVERTER MAP REV:2 PAGE FL-04 CREW LEAD: INVERTER INFORMATION PHOTO CHECKLIST DATE: INVERTER STRING VOLTAGE Y N PHOTO CHECKLIST DONE(SEE RIGHT)? 1 BRAND: 1 INVERTER MAIN PANEL WIRING BREAKER TIE IN LOCATION Y N PERMIT LEFT FOR INSPECTION? MODEL: 2 SERIAL NUMBERS WIRING WHERE? LOCATION: 3 STRING DIAGRAM CONDUIT CONNECTION Y N JOBSITE CLEANED UP? SERIAL: 4 MOUNTING LABELING 5 CONDUIT CONNECTIONS GEC Y N CONDUIT PAINTED? 6 LABELING Y N STICKERS&PLACARDS INSTALLED? CONDUIT(SHOW FULL RUN) SYSTEM SIZE:8000W 2 BRAND: 1 DISCONNECT ATTIC CONDUIT MODULES: Y N DAMAGE REPAIRS NEEDED? MODEL: 2 WIRING EXTERIOR CONDUIT (20)SOLARIA POWER XT-400R-PM Y N JOB PHOTOS TAKEN LOCATION: 3 MOUNTING(CLEARANCES) INVERTER: SERIAL: 4 CONDUIT CONNECTION CONDUIT PENETRATION ENPHASE IQ8PLUS-72-2-US Y N OPTIMIZER/MICROINVERTER MAP FILLED OUT? BEFORE SEALANT 5 LABELING AFTER SEALANT Y N CLIENT WALK THROUGH COMPLETED? 6 SURFACE TYPE:ROOF JUNCTION BOXES Y N YARD SIGN INSTALLED? 3 BRAND: 1 FLASHING AHJ:YARMOUTH TOWN WIRING Y N WAS SYSTEM LEFT ON? MODEL: 2 WEEP HOLE UP CLOSE CONTRACTOR: LOCATION: 3 CONDUIT CONNECTION STEPPED BACK `=M*....0.. SERIAL: 4 LABELING " -• a eauCE 5 lorP solar & home OTHER ITEMS NEEDED? COMBINER BOXES ROOFING MATERIAL 6 WIRING ADDRESS 92 GROVE STREET,GLOUCESTER.IAA 01930 4 BRAND: 1 UNDER ARRAY BEFORE PHONE 978-261-1625 WEEP HOLE MODULES MODEL: 2 AROUND ARRAY PROJECT NAME: CONDUIT CONNECTION LOCATION: 3 LABELING AFTER MODULES LAGREE,SUSAN SERIAL: 4 PROJECT ADDRESS: RAIL MOUNTING ARRAY WIRING 5 46 SQUIRREL RUN ST., HARDWARE HOME RUNS 6 STEP BACK VIEW JUMPERS YARMOUTH PORT,MA 02675 ATTIC PENETRATIONS TEL.#: 978-S01-3680 APN# ..RMM0123.1.80L° GROUNDING WIRE JOB NUMBER:11759 OPTIMIZERS DRAFTER: FINISHED ARRAY REVISION HISTORY REV DESCRIPTION DRW DATE 0 DRAFTER REVIEW AH 10-05-22 1 COMMENTS INCORPRATED NN 10-18-22 2 COMMENTS INCORPRATEE AH 10-29-22 3 4 5 6 7 8 SHEET JOB CHECK SHEET REV:2 PAGE FL-05