HomeMy WebLinkAboutBLDE-23-002984 -
Commonwealth of Official Use Only
fi: Massachusetts Permit No. BLDE-23-002984
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/1/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 455 WINSLOW GRAY RD
Owner or Tenant MATTHEW MARAIS Telephone No.
Owner's Address 455 WINSLOW GRAY RD, SOUTH YARMOUTH, MA 02664
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters _
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (21 Panels 7.665 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law. But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
A 24.24 -,s-c /1-41).
2g2)3 ��
RECEIVED
NOV `� O 2 Q/ Kn/� / Official Use Only
I' J ealth ol///a3eachuseltd
z,1L cc��rr�� c�77 Permit No.
=.= ; The ar, •nl of ire Services
..-alpiefUILDING DEPARTMENT Occupancy and Fee Checked
; 'Y: :e.:.:e e. - ' 'EVENTION REGULATIONS [Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 11 ) a s I a a
City or Town of: yar mc4h To the Inspector of Wires:
E By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) Li 5 5 Lk\.,A n I Ow 6,r G, vet
Owner or Tenant rn('i .W p,l J m(i x Q 1 5Telephone No.71y a .h013`7
Owner's Address VQ & WeeNta2
Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box)
SPurpose of Building Utility Authorization No.
Existing Service DO Amps no /aLj volts Overhead k❑ Undgrd n No.of Meters
�5 New Service Amps, / Volts Overhead n Undgrd I I No.of Meters
V Number of Feeders and Ampacity
LJ Location and Nature of Proposed Electrical Work: 1 5+j lQ+,(Y Of c� l(-+exc fl f9{ '
. .r
Completion of the followin&table may be waived by the Inspector of Wires.
•
r Ceil.-Susp.of Recessed Luminaires No.of Ceil Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
d No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
E.! No.of Switches No.of Gas BurnersTota No.of Detection and
Initiating Devices
-�— No.of Ranges No.of Air Cond. Tonsl No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Connection Municipal ❑ Other
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
0 No.of Water KW No.of No.of Data Wiring:
.�-- Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunicaions Wiring:
No.of Devicet s or Equivalent
OTHER:
J Attach additional detail if desired,or as required by the Inspector of Wires.
Od Estimated Value of Electrical Work: 3 0,0 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
i the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
.8 undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
certify,under the pains and penalties of perjury,that the information on this application is true and complete.
IS I
FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al
Licensee: Nathan Ashe Signature �.,-� LIC.NO.:21136A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-5943519
Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
(:)-
e I.
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE N DESCRIPTION PM R •SYSTEM SIZE:7665W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(21)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
LTD:LR4-60HPH-365M INSTRUCTIONS.
PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
MP MAIN PANEL SE6000H-USSN
PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436
SP SUB-PANEL •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
WITH NEW 225 AMP MAIN PANEL WITH 200 AMP MAIN
LC PV LOAD CENTER BREAKER. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
-- - •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
N OF,HAS
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL ry"0VAs 'k
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ° L 4o0yom
CML H
n AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). N0.56313
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 100 EO srzpy kt,
O DC DISCONNECT(S) Ff'YSTONALEN°�-
•11.43 AMPS MODULE SHORT CIRCUIT CURRENT.
Exp:6/30/2024
CB IQ COMBINER BOX •17.85 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(A)&690.8(B)]. STAMPED 11/25/2022
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
ABBREVIATIONS r 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
A AMPERE
L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER r '1, CHIMNEY s r
un
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT #180120
(E) EXISTING FLUSH ATTIC VENT VICINITY MAP
6P5 IMES STAN06H KM TAUNTON,NA,021e0-7131
ESS ENERGY STORAGE SYSTEM , PVC PIPE VENT 4) <.�I—'I PHONE
EXT EXTERIOR .44 FAxO
METAL PIPE VENT CUSTOMER RESIDENCE:
INT INTERIOR
MADISON MARAIS MSP MAIN SERVICE PANEL >C T-VENT 4 5WINS OW GRAY RD,
(N) NEW -= YARMOUTH,MA,02664
7 SATELLITE DISH
NTS NOT TO SCALE ., r-..(+.
TEL.(508)737-9958
OC ON CENTER FIRE SETBACKS APN:YARM-000058-000210
PRE-FAB PRE-FABRICATED
PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT I W , F 223R-455MARA
HARDSCAPE .[iy55 Winslow Gray
PV PHOTOVOLTAIC Rd SoirtL I:Yarmouth (-219
F18tWCh DESIGNER: (415)5805920ex3
ROD RAPID SHUTDOWNDEVICE —PL- PROPERTY LINE
SOLAR MODULES AMAN SONI
R TRANSFORMERLESS I f•.N 0 C F t•. . ` :
SCALE:NTS "' '�
TYP TYPICAL - _r -- SHEET
V VOLTS REV NAME DATE COMMENTS COVER SHEET
111I
W WATTS O I —
I REV:Al 11/26/2022
LAN LANDSCAPE I SNR MOUNT -; PAGE
PV-1.O
POR PORTRAIT SNR MOUNT&SKIRT
Tempate_vmv0n_I 0.86
SITE PLAN-SCALE•1/16"=1'-0"
�fTl� �4,s Mov4 6N
0 CIV
IL * t
NO.56313
>SIL
9 �EOtS1EeEe 4`"�
o�FSONAIEM�'`�
PL PL
PL �� PL Eap:6/30/2024
STAMPED 11/25/2022
P (N)ARRAY AR-02
(E)RESIDENCE
1 ___ INV
I 'i 0 ri
Li 0
e—
„ rMP
-,L, \° SE AC PM sunrun
°a .
(N)ARRAY AR-01 #180120
ass rnvLes srnHois"aLw,rauurou,ue,62760433+
•
CUSTOMER RESIDENCE:
MADISON MARAIS
455 WINSLOW GRAY RD,
YARMOUTH,MA,02664
FL ----\
'-� FL
ARRAY TRUE MAG PV AREA TEL.(508)737-9958
--�— PL `— FL PITCH AZIM AZIM (SOFT) APN:YARM-000058-000210
WINSLOW GRAY RD AR-01 25° 178° 192° 294.1 PROJECT NUMBER
223R-455MARA
AR-02 25° 358' 372' 117.7
DESIGNER: (415)580-8920 ex3
AMAN SONI
SHEET
SITE PLAN
REV:Al 11/26/2022
PAGE PV-2.0
Template w n a.0.86
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
Name Type Height Type Span SpacingDetail OC Spacing OverhangOC Spacing Configuration
P 9 Overhang SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X4 RAFTERS 6'-4" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREW
AR-02 COMP SHINGLE-RLU 1-Story 2X4 RAFTERS 6'-4" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 5/16"xl/4"MIN.EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436
D1-AR-01-SCALE:3/16"=1'-0" 06 OFM�1
AZIM:178• INSTALLERS SHALL NOTIFY ENGINEER OF �.+ MOvq Gc
PITCH:26' ANY POTENTIAL STRUCTURAL ISSUES F° ` C1 yGM
1# 1 28 11' 1 2-0"} OBSERVED PRIOR TO PROCEEDING W/ o CIVIL '�
1 INSTALLATION. " NO.56313 '^
•IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" r6srorre0.0.
BOUNDARY REGION OF ANY ROOF PLANE EDGES
(EXCEPT VALLEYS),THEN ATTACHMENTS NEED E■o:6/30/2024
= _ _ TO BE ADDED AND OVERHANG REDUCED WITHIN STAMPED 11/26I2022
THE 12"BOUNDARY REGION ONLY AS FOLLOWS:
�_ _ inr.
10,_3„ ONALLOWABLE PLA S TO BE REDUCED NB 50%ING INDICATED
••ALLOWABLE OVERHANG INDICATED ON PLANS
1111111= M TO BE 1/5TH OF ALLOWABLE ATTACHMENT
IniSPACING INDICATED ON PLANS.
D2-AR-02-SCALE:3/16"=1'-0"
AZIM:358° sun run
PITCH:25° 1't _i 23,-2„ __.... ___.__.r 24'-3"
#180120
•
115 MYLES STANDEE BLVD.TAUNTON.MA,0]]10-7331
PHONED
FAX
_________ 0 EI CUSTOMER RESIDENCE:
MADISONMARAIS
) 455 WINSLOW GRAY RD,
YARMOUTH,MA,02664
TEL.(508)737-9958
---- 6'TYP ❑ APN:YARM-00005e-000210
a PROJECT NUMBER:
_ 6'3" 223R-055MARA
3'-11" ''. DESIGNER: (415)580 8920 ex3
I
/ . AMAN SONI
SHEET
11'-7" 30.5" -- LAYOUT
SEE SITE PLAN FOR NORTH ARROW. REV:Al 11/26/2022
PAGE PV-3.0
Templale_ve n_0 0 66
120240 VAC
SINGLE PHASE
SERVICE
METER#:
< ® EVERSOURCE 2369105
UnuTY
GRID
(1 NEW 200A MAIN
DISCONNECT
1
1...„
i-LOAD SIDE TAP
)LOCKABLE
1 NEW 200A MAIN BLADE TYPEL (N)MA SMART
BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES:
DISCONNECT REVENUE SE6000H-USSN
METER 6000 WATT INVERTER JUNCTION BOX PV MODULES
''.--N NEW
(-3 METER
3 i 2 OR EQUIVALENT (1) LONGI GREEN ENERGY TECHNOLOGY
�� PANE225A MAIN A, --�� // CO LTD:LR4EOHPH-S65M
L �� (21)MODULES
® — �77- —� 11 / OPTIMIZERS WIRED IN:
FACILITY -- 35A FUSES __J_-r-I_(1)SERIES OF(11)OPTIMIZERS
LOADS
- -z`a«a� SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(10)OPTIMIZERS
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401
120240VAC CONNECTS TO TOP LAOS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHNITHWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
MSS MYLES STANDISH BLVD,TAUNTON,MA,027S0-7331
PHONE 0
FAX 0
CUSTOMER RESIDENCE:
MADISON MARAIS
455 WINSLOW GRAY RD,
YARMOUTH,MA,02664
MODULE CHARACTERISTICS TEL.(508)737-9958
LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: APN:YARM-000058-000210
MIN INPUT VOLTAGE: 8 VDC
TECHNOLOGY CO LTD:
365 W MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
PH-365
MAX INPUT ISC: 11.75 ADC 223R-055MARA
OPEN CIRCUIT VOLTAGE: 40.7 V
MAX POWER VOLTAGE: 34.2 V MAX OUTPUT CURRENT: 15 ADC 415 580-6920 ex3
SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: ( )
SYSTEM CHARACTERISTICS-INVERTER 7 AMAN SONI
SYSTEM SIZE: 7665 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE: 480 V
REV:Al 11/26/2022
SYSTEM OPERATING CURRENT: 20.17 A
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
7emplate_ve n_40.36
AWARNING INVERTER 1
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
MAXIMUM SYSTEM VOLTAGE 480 VDC 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
TERMINALS ON LINE AND LOAD IF REQUESTED BY THE LOCAL AHJ.
SIDES MAY BE ENERGIZED IN LABEL LOCATION: •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). WORDS,COLORS AND SYMBOLS.
PER CODE(S):NEC 2020:690.53 •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
METHOD AND SHALL NOT BE HAND WRITTEN.
LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT
INVERTER(S),AC/DC DISCONNECT(S), INVOLVED.
AC COMBINER PANEL(IF APPUCABLE). •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
PER CODE(S):NEC 2020:690.13(B) SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
•DO NOT COVER EXISTING MANUFACTURER LABELS.
WARNING: PHOTOVOLTAIC
AWARNING POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012:
SYSTEM 605.1 t.7.4
LABEL LOCATION: CAUTION :
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
ZNWARNING
POWER SOURCE OUTPUT CONNECTION_ FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS I\
OVERCURRENT DEVICE LABEL LOCATION: \�
INSTALLED WITHIN 3'OF RAPID SHUT DOWN
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:fi90.56(C)(2),IFC Pi ` s u n r u n
ADJACENT TOO PV BREAKER AND ESS 2012:605.11.1,IFCC202016:1204.5.3
OCPD(IF APPUCABLE).
PER CODE(S):NEC 2020: 4'
705.12(6)(3)(2)
AWARNING SOLAR PV SYSTEM EQUIPPED - #160120
PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN III I SOLAR PANELS ON ROOF WOVE 0 6TMYM6M BLVD,TALNfd4 MA 02760.7331
COMBINER PANEL F.0
DO NOT ADD LOADS III IICUSTOMER RESIDENCE:
LABEL LOCATION: 111111 in MADISON MARAIS
455 WINSLOW GRAY RD,
PHOTOVOLTAIC AC COMBINER(IF (I 1 YARMOUTH,MA,02664
PER CODE(S):
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) TURN RAPID SHUTDOWN LINVERTER (EXT)
SWITCH TO THE"OFF" ry• TEL.(508)737-9958
POSITION TO SHUT DOWN PRODUCTION METER AP N:YARM-000058-000210
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECTI lin PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT:25.00 AMPS SHOCK HAZARD IN THE SERVICE ENTRANCE 223R-455MARA
NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. (MAIN PANEL (INT) 415)580-8920 ex3
DESIGNER:
LABEL LOCATION: 455 WINSLOW GRAY RD, YARMOUTH, MA, 02664 AMANSONI
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. - -- - -.. __ __-_ --._-_ __ _ SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S) NEC 2020 705.10,710.10 SIGNAGE
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
REV Al 11/26/2022
PER CODE(S):NEC 2020:690.56(C) -
PAGE PV-5.0