HomeMy WebLinkAboutEngineer PlanNG ON XI 44.78 * NOTE: EVERIIFY INVERT BEFORE CONSTF UCTIONTIOF ANY LOCATION OFRTHE SEPT CMSYESTEM. ACCESS COVER WITHIN 6' TO FIN. GRADE ACCESS COVER (WATERTIGHT) EL.40.0f ELWITHIN 6' TO FIN. GRADE .40,0± MINIMUM .75' OF COVER OVER PRECAST TOP OF TANK = EL.37,07 RUN PIPE LEVEL %FOR FIRST 2' EXISTING 1,000 / GALLON SEPTIC I / 7 VERIFY IF FIELD ELRIEY4* TEE TANK (H- 10 > H-10 GAS oo EL.31,52 BAFFLE EL.31.69 o g CRUSHED STONE OR MECHANICAL DEPTH OF FLOW = 4' COMPACTION. (15,221 1.23) REQUIRED TEE SIZES: INLET DEPTH = 10' MIN. BELOW FLOW LINE OUTLET DEPTH = 14' MIN. BELOW THE FLOW LINE ( I MIN. SLOPC) (-2--Z MIN, SLOPE) (94t SLOPE) C SLOPE) F❑UNDATI❑N EXISTING SEPTIC TANK 43' D' BOX -2' 2' LEACHING FACILITY SYSTEM PROFILE (NOT TO SCALE) PROPOSED VENT TO BE LOCATED BY CONTRACTOR AT TIME OF INSTALLATION PROPOSED / .0BOX -i - 5' REMOVAL REQUIRED 42't DEEP rLr BOTTOM B LAY£X' SEE TEST hOLE LOG ENGINEER TO INSPECT d CERTIFY REMOVAL PROPOSED --SOIL A.8SORPTION SYSTEM 4 HIGH CAPACITY AM-& TRATORS H-20 VITH 3.5' OF STONE ALONG THE SIDES, OF STONE AT THE ENDS AND 14' Of" STONE BELZ7V P�7SED -- C£AMOUT VYE REUSE EXISTING -1,000 GALLON SEPTIC TANK LOT 34 - 2" DOUBLE WASHED PEASTONE -- 2% SLOPE REQUIRED OVER SYSTEM 3S' a SIDES 3' P ENDS 10, H-20 14' 3/4" TO 1 1/2" DOUBLE WASHED STONE 16' 3Z' P SIDES 3' E EImS EL.30.67 l.. 51 REAUVAL REQUIRED 421.t DEEP ' TO BOTTOM .9 LAYER 7.5' S££ TEST Air LDCi ENGINEER TO INSPECT & CE?TIFY REMOVAL 111 1 31�2� �30 3CTI 33 - EXISTING } TANY, " LEACH PIT(S 1 DECK T 37 J7 O APPROXIMATE LOCATION ' �2 (SEE NOTE 6) TH = 1 / DECK 10" IN BASEMENT i SLAB = EL.37.3f O EXISTING 1 M HOUSE LOT 36 TF = EL.44.78' 9.83, e� 10 '�o 1! LAtr i\7n r'E l 1 TIE RE T WALL ! , LOT 3 '1 \1 1 ,721 S f ED BENCHMARK \ 1 DRI 1 HYDRANT 1 TAG BOLT #632 ' 1 EL.44.87 ` ASSUMED SE o 6 HARBOUR HILL RUN off. 508-362-4541 fax 508-362-9880 down cape engineering, Inc. CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 SITE PLAN SCALE: 1 "=20' .I/' - .� r r r , i OF THI EL.22,0 t ;EPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED) NUMBER OF BEDROOMS: 3 DESIGN FLOW- 3 BR x 110 G/D/BR = 330 G/D USE A 330 G/P REQUIRED DESIGN FLOW ZPTIC TANK: 330 G/D (2) = 660 G/D USE PROPOSED 1,500 GALLON SEPTIC TANK Af H Na.- SIDE AREA: 2 x 2' x (9.83'+31') = 163.3 SF BOTTOM AREA: 9.83' x 31' = 304.7 SF SIDES: 163.3 SF + BOTTOM: 304.7 SF TOTAL: 468 SF PROPOSED CAPACITY: 468 SF x 0.74 G/D/SF = 346.3 G/D O.K. SEPTIC SYSTEM DESIGN DATA BRACE WITH P.T. 4"X4" POST STAINLESS STEEL STRAP-` AND SCREEN BOARD OF HEALTH M /\ CONNECT TO D-BOX WITH 4 SCH40 PVC AND VENT SYSTEM VENT NOT TO SCALE l 2 DATE LEGEND 'X\Oo WATER SHUT OFF VALVE - EXISTING WATER LINE t�- APPROXIMATE LOCATION HYDRANT ENCHMARK tiY'� "So GAS SHUT OFF VALVE TO BE LOCATED EXISTING GAS LINE TO BE LOCATED -35--` EXISTING CONTOUR +41.26 EXISTING SPOT GRADE LOW OVER HEAD WIRES ELECTRICCABLE T.V. --mot - PROPOSED CONTOUR X 22.10 PROPOSED SPOT GRADE TH1 SOIL TEST HOLE 5 EE TEST HOLE LOG(S) ASSESSORS MAP 91, PARCEL 157 NOTES: 1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS APPROXIMATE. PRIG; TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE (1-888-344-7233) A;JD ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR EQUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. 2. ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5 AND YARMOUTH HEALTH REGULATIONS. 3. VERTICAL DATUM IS NG'✓D, ELEVATION ASSUMED FROM QUAD. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H 10. 5. THIS PLAN IS FOR A. PROPOSED SEWAGE DISPOSAL SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 6. PUMP DRY AND REMOVE OR FILL WITH SAND ANY EXISTING LEACH PIT(S). 7: ALL SEPTIC PIPING SCH-40-4" PVC UNLESS NOTED. 8. COMPONENTS NOT TI7 BE BACKF ILLED OR CONCEALED WITHOUT L. !••I-^-•!�:. e ULif" L:r il. hL'+r n�:✓ ic^i-�i�Jiu�v 6LTNiivL1) FROM BOARD 'OF HEA. TH. 9. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 10. PIPE JOINTS TO BE M".DE WATERTIGHT. 11. WATER TEST D-BOX FOR LEVELNESS. 12. * NOTE: EXISTING INVE`�T OUT OF SEPTIC TANK EL.35.74t, ELEVATION AND LOCATION ARE APPROXIMATE, VERIFY EEINVERT BEFORE COLNSTRUCTIOCCN OF ANY PORTION OF THE SEPTIC SYSTEM. 13. REPLAC. TEES IF NOEFOEDLT0 CONFORM TO TITLE V, AND INSTALL GAS BAFFLE. DEPTH 6-0 THI ELEVATION 0' 34.0 12, 18' 42' 72' 144' SOIL CLASS: I (SANDS, LOAMY SANDS) 33.0 PERC RATE: < 2 MPI (5 MPI DESIGN) PRESOAK: 0:00:00-0:07:15 (24 GAL. < 15 MIN.) 9': 0!07:15 32.5 BOTTOM PERC: AT 50' EL.29.8 NO WATER OBSERVED 30.5 DATE: 12/15/99 ENGINEER: MICHAEL S. FARIA, SE 28.0 (DOWN CAPE ENGINEERING) WITNESS: KELDA WELSH EXCAVATOR: BORTOLOTTI CONSTRUCTION + 22,0 REC[ERMFD VEST HOSE LOG NOT TO SCALE DEC 2 8 1999 HEALTH DEPT. TITLE 5 SITE PLAN OF LAND IN SOUTH YARMOUTH, MA PREPARED FOR CARL GREENE LOCATED AT 14 HARBOR HILL RUN SOUTH YARMOUTH, MA SCALE: 1 "=20DATE: 12-21-99 REVISED: ______ 20� 0 � 20 40-�`� 60 Feet