Loading...
HomeMy WebLinkAboutEngineer PlanACCESS COVERS MUST BE WITHIN 9' MINIMUM, 6' OF FINISH GRADE 3' MAXIMUM COVER 103.62 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE 4' DIAM PIP 2 • 060 DOUBLE WASHED STONE Y GAS o e 1 SAFFL£ Q 0 � 3 OUTLET 2-500 GAL LEACHING CHAMBERS D-BOX W/4 ' STONE AROUND. 12. 8 'X 25 'X 2' 1500 GAL SEP T / C TANK 6 " CRUSHED STONE OR COMPACTED BASE PROF l L E : NOT TO SCALE ' jRANS/TEL/TV INVERT ELEVATIONS. INVERT AT BUILDING: _101,12 INVERT IN SEPTIC TANK: ��.75 INVERT OUT SEPTIC TAIIK: 29.5 INVERT IN DIST. BOX: _.-9R.27 INVERT OUT DIST- BOX: n.C" 1 INVERT IN LEACH CHAI4PEP: 9,0.0 60TTOM OF LEACH CHAU EP: 96.0 <DJUSTED GROUND WA TER: N/A OBSERVED GPOUND i" A TER : N/A BOTTOM OF TEST HOLE. *l: 90.7 _ _ S /0�44 SO'E BM. CATCH BASIN ` _ �' OQ RIM-99.52 -_ 2-500 GALLON LEACHING CHAMBERS —4y4' STONE AROUND ` _ m 2S • 41 I �-.cr' ti � rs• e Tpol ti t D-BOX h ji 3 BY NE CORNER TOP STEP EL-103.94 ' O G COO GALLON OI��M _C IS• 1 SEPTIC TA/IK 1 1r i 1 I I t / r � �" LOT 4 20006 - * S . F . r f LOCUS MAP t i 1 c t o ' m pE"CK ` I s ' y CESSPOOLS ' — CLEANOUT � r 1 � f ti l i y s I I 0 /0 20 N DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 1 10 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REOUIRED: DESIGN PERC RATE ( 5 H I N/ I NCH SOIL TEXTURAL CLASS - I EFFL DENT L OAD / NG RA TE - 0. 74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED >'PO'✓IDED: 2-500 GAL LEACHING CHAMBERS W/4' STO,VE AROUND. A-471 S.F. 471 S.F. x 0.74 - 346 G.P.D. SOIL TEST PIT DA TA I ND 1 CA TES V_ I ND I CA TE"S PEPCOLA. T r 0"1 _ OBSERVED TEST GROUh'DiAtER TP */ 0. HORIZON TEXTURE COLOR KILL 5 - ................... .. .................. A L OAAfY I O YR SAND 2/2 ....... ....... ............... ..... B LOAA'Y IOYR SAND 6/8 26 " .... ............................... ..... C I MED I UM I O YR SAND 6/4 48, 126= NO CA TER DATE: NOVEMBER 27. 2001 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH 101.2 100.8 100.4 99.0 90.7 GENERAL NOTES: I. THIS PLAN IS FOR THE CESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN, J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM $HALL CONFO°M TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATION'S. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D-BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1-8P8-016-SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UrlLlTIES. 8. EXISTING CESSPOOLS TO BF PUMPED DRY AND BACKFILLED. 9. ALL UNSUITABLE NATE'RIAL (A d B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED rI TH SAND IN ACCORDANCE WITH TITLE 5. G k_* S EE P T/ C S )_11' S T EEM 0 E- S/ G /V 32 HOMES TEA O L A ME . MA P 10.2. PA R CEL 2 / YAR"OUTAPORT. "A. PRE -PA RED FOR : S T _ P f--/,mil /V / EE C O O P E R /.5.5 WEST 68TH ST.- APT 1229. IVY. IVY 10023 SCALE : / — 20 DECEMSE—R 2 1 . 2001 EAGI.._.- E SURVEY I NG , 1 NC 923 Route 6A Ya rmou t hipo r t MA. 02675 (508) 362-8 1 32 (508) 432-5333 40 I JOB NO: 0 / - l20 I FIELD :CFI /EEK CAL C: SAH/CFW CHECK : CFW a � ID .J A N 3 1 2002 HEALTH DEPT.