HomeMy WebLinkAbout2024 P202 Holding Tank DetailTHREADED ROD ANCHORED TO UNDERSIDE REMOVABLE GAP CONCRETE DECK, STRUCTURAL LAL R =DRAIN HV7 DUTY UNISTRUT SPANNING STRUCT ROF SUPPORTS (300 LB. MIN.-TYP) - AMTROL THERMAL EXPANSION VACUUM RELIEF VALVE TANK MODEL ST-12 CONFORMS TO ANSI Z21.12 - - - -- -- - -- - - FULL SIZE OF —► DRAIN - - COLD WATER SUPPLY -- _ �� _THERMOMETER W/WELL - UNION CONNECTION IN -LINE RECIRCULATING PUMP ELECTRIC WATER HEATER ASSEMBLY. SEE DETAIL AS.M.E APPROVED TEMPERATURE EACH DIMENSION IS EQUAL TO FAN RECIRCULATING HOT - - - AND PRESSURE RELIEF VALVE NEGATIVE STATIC WATER (I10°F) ATTACH WATER HEATER TO f?R;:661 IRS BALANCING VALVE I �� UNISTRUT IN 4 PLACES SHUT-OFF VALVE (TYPICAL) RELIEF PIPE -FULL SIZE OF APPROVED AIR MIXING VALVE DISCHARGE OPENING ARCHITECT GAP HEIGHT THERMOMETER POWER SOURCE Q HOT WATER SUPPLY Mel) �-- — FUSED DISCONNECT Brian Grl@b, AIA 2200 SOmmerVlle Rd, HUB DRAIN HEAT TRAP DRAIN VALVE PAN Suite 201 'i UNION (TYPICAL)DRAIN , TO FLOOR DRAIN OR OTHER Annapolis, MD 21401 CONTRACTOR TO PROVIDE SIGN ON HEAVY DUTY UNISTRUT SUPPORT RAIL (TYP.) BUILDING ADACENT TO TIGHT TANK WITH APPROVED INDIRECT WASTE DRAIN „ DRAIN PAN OVER FLOW DRAIN CONTRACTOR TO PROVIDE 30 CAST LETTERING NON-HAZADOUS INDUSTRIAL a /� IRON COVER ON 30" I.D. H-20 RISER. WASTE HOLDING TANK" IN 2" LETTERING. CO��EENSATE Dt�f-�kIN D�TAIL 410-919-9669 INTERNAL TANK RISER TO Ex TEND UP 1I. InfO@grlCiarChlteCtS.COm INTO N-20 RISER TO WITHIN 12" of e:,,.,a�,� ,,,,r.,,,. hA&.,,,, A, AaMA& NOt t0 ELECTRIC WATER HEATER DETAIL %AAAAA, rYrir4nrr-hitAr-tc r_nm GRADE FOR EASE OF ACCESS. _ .. ,.. SILENCE SWITCH, AND PANEL INSIDE BUILDING PER HOLDING TANK MANUFACTURER REQUIREMENTS. INTERFACE WITH FIRE ALARM AS REQUIRED PER AHJ. IN THE EVENT GRADE THE TANK FILLS 3/4 OF THE WAY ALL CONTRACTOR TO PROVIDE AUDIOVISUAL DEVICES SHALL - - LEAK DETECTION FLOAT - a _ ACTIVATELOW VOLTAGE FLOATS, - ACCESSED THROUGH RISER SIMPLEX PANELS, MYERS OR EQUAL IN INTERSTITIAL SPACE BETWEEN TANKS LEAK DETECTION AND HIGH-LEVEL - - MONITORS ARE CONNECTED TO AUDIO 3 d,< AND VISUAL ALARMS ON THE PANEL VENT , (2) GALVANIZED STEEL °a• CONDUIT FOR ALARM TANK DESIGN. 11N PROPOSED USE7 INDOOR CAR PARKINGISNOW MELT. 60 "° " GALLONS PER DAY. 60 GPD x 500% = 300 GALLONS. - • 500 GALLON TANK ADEQUATE -- - _ -- INTERNAL CONCRETE TANK a` HOLDING TANK SHALL BE H-20 $00 GALLON NON- HAZARDOUS INDUSTRIAL WASTER WATER TANK HOLDING SYSTEM BY ACME PRECAST OR EQUAL, DOUBLE P CONTAINMENT HOLDING TANK SYSTEM SHALL CONSIST OF 4-20 RATED WATER -PROOFED 1,000 GALLON NON - a HAZARDOUS INDUSTRIAL WASTER WATER TANK W/INTEGRAL = < .° :. , ° • ° a < . 500 GALLON MONOPOUR TANK, WATERPROOFED, VENTED, r ; ..; WITH PLASTIC RISERS UP TO 1,000 GALLON RISER. VENT AS INDICATED ON PLANS. SIGNAGE "NON -HAZARDOUS INDUSTRIAL WASTER WATER- HOLDING TANK" SIGNAGE TO BE INSTALLED ON BUILDING ADJACENT, SEE SEPARATE CONSTRUCTION SPECIFICATIONS FOR DETAILS, LOG BOOK REQUIREMENTS, ETC. REFER TO 314 CMR 18.00 .q HOLDING TANK DETAIL J 124 = I'-0" NORTH An MAY EXTEND - AS WASTE OR VENT (-vl GLEAN -OUT WALL PLUGGED TEE WITH CLEANOUT WALL COVER FLOOR LINE AND SCREW NOT BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. NOTE. ALL CLEANOUT LOCATIONS SHALL BE INDICATED ON CONTRACTOR'S PLUMBING SHOP DRAWINGS FOR REVIEW BY THE ARCHITECT/ENGINEER PRIOR TO START OF CONSTRUCTION.__ UJALL CLEANOUT DETAIL NOT TO SCALE PAVED AREA CLEANOUT ACCEE G.I. CL.EANOU' FERRULE Q P (y GLEANOUT DETAIL NOt TO SCALE NOT TO SCALE TEMPERED HW (110°F) 1 I DOWN IN WALL TO FIXTURE, SEE PLAN FOR 1 SIZE 1 TEMPERED HW U10 IN WALL FROM FIXTUI SEE PLAN FOR SIZE FOOT MAX 1 / i " TO FAUCET HW VALVE 1/2 HW (110'F) SUPPLY FINISHED FLOOR HOT WATER LOOP DROP IN WALL DETAIL NOT TO SCALE BALL VALVE - WATER SUPPLY TRAP PRIMER VALVE DISTRIBUTION UNIT AS REQ'D 1 TO 4 OPEN'G 11" MI CONNECTION TO FL OR TRAP (TYPICAL) 3 Ti�AP PizIMEi� DETAIL NOT TO SCALE MEP CONWAY & OWEN 1455 Bluegrass Lakes Pkwy, Alpharetta, GA 30004 678-820-4607 kfinlay@conway-owen.com www.conway-owen.com STRUCTURAL McLAREN ENGINEERING GROUP East Pratt St j 601 , Suite 302 Baltimore, MD 21202 410-243-8787 - briggs@mgmclaren.com www.mgmclaren.com AutoGlass STORE #4715 40 WHITES PATH, YARMOUTH, MA 04/05/2024 REV DATE TITLE 04/18/23 PERMIT SET 1 02/29/24 ASI02 2 04/05/24 ASI 02 R2 ® COPYRIGHT PROJECT NUMBER 2216 DETAILS - PLUMBING