Loading...
24-E042 27 Pine Street OKH Approved Solar WolfYA Mr1# TH _170O F-P TOWN OF YA R M O U T H'°*= F '_ C Y 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 Telephone (508) 398 2231 Ext. 1292—Fax (508) 398-0836 RFCF-IVI. 0 KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE APR 2 2 20241 APPLICATION FOR YHKMUIJTr' CERTIFICATE OF EXEMPTION ni n vis�ir=IC WIrWWAY ' Application is hereby made for the issuance of a Certificate of Exemption under Sections 6 and 7 of Chapter 470 of Acts of 1973, as amended, for the proposed work as described below and on plans, drawings, or photographs accompanying this application. Address of proposed work: 27 Pine Street MaplLot# 12314 Owneds�. Daniel Long Phone #: 571-228-3490 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 27 Pine Street, Yarmouth Port, MA 02675 Year built: 1994 Email: dlong88635@gmail.com Preferred notification method: Phone Email Aoenycontractor. Roger DzuVincite Solar Solutions Phone #: 978482-6053 Mailing Address: 65 Avco Road, Unit H, Haverhill, MA 01835 Email: info@incitesolarsolutions.com Preferred notification method: Phone Email Due to the Solar Wolf issues, and the resulting construction interruption, this property with valid OKH approvals was unable to proceed. This Exemption shall allow this property, subject to the Solar Wolf issues, having permits through Old Kings Highway Commission, to proceed with the understanding that the Exemption that will allow a one-year extension from April 1 lth, 2024. Such extended approval is understood to be in keeping with the original approval. Assistant Town Administrator Signed as Agent pending Contractor and Owner Confirmation Signed (Owner or agent): > ownerlcontractorlagent is aware that a permit maybe required from the Building Department. (Check other departments, also) > This certificate is good for one year from approval date or upon dale of expiration of Building Permit, whichever date shall be later. FOTZ� ,, L,li 7:1717111 Date: 1vs,�1/A"t Amount NA Cash/CK M A/ Rcvd by: Lt 5 ZApproved Approved with changes Reason for denial: 0 12024 Date Signed: 51 t 11)l Signed: APPLICA7iON #: 24-EO42 vi 7G 17 Sherman, Lisa From: Scott, William Sent: Wednesday, Apri 24, 2024 4.26 PM To: Sherman, Lisa Subject: RE: Solar Wolf OKH Lisa: Given the owners and contractor may take some time to sign 1 would recommend I sign the form. I will be back on Friday, lets arrange signatures then. At this point can this phase be added: Assistant Town Administrator Signed as Agent Pendinz Contractor and Owner confirmation. I will write cover letters for the contractor to then attach to the file indicating they are the agent. The email back from the owner will then also serve as confirmation. That allows you to proceed signifying the chairs action. Does that work for you? William) Scott Assistant Toren Administrator Town of Yarmouth, Massachusetts https:l f wwwxarmouth.ma.us/ APPPOVED MAY 0 12024 r AFsMOUTh From: Sherman, Lisa <LSherman@yarmouth.ma.us> Sent: Wednesday, April 24, 2024 2:03 PM To: Scott, William <WScott@yarmouth.ma.us> Cc: Sherman, Lisa <LSherman@yarmouth.ma.us::- Subject: Solar Wolf OKH Hi Bill, Bob has signed all the OKH Solar Wolf Certificates of Exemption. An agent needs to sign the Certificates of Exemption as well. Would that be you in this situation, or would you want someone from Incite to sign them? Once they are signed need to clock them in with the Town Clerk and scan them into Laserfiche for record retention. Let me know what we need to do next and let me know what I can do to help. Thanks Bill, Lisa TOWN OF YARMOUTH 1 146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-24451 Telephone (508) 398-2231, ext. 1271, Fax (508) 398-2365 Robert Wilkens Chair, Old Kings Highway Commission Town of Yarmouth, Mass Town Hall 1146 MA-28, South Yarmouth, MA 02664 April 19, 2024 Dear Mr. Wilkens. ASSISTANT TOWN ADMINISTRATOR William J. Scott APPROVE MAY 0 12024 �3RMUUTh This letter is a request to allow the properties that received decision from Old Kings Highway Historic District Commission, and were subject to the Solar Wolf issues, to proceed with their projects under those approvals. Around May of 2022 it was discovered that Solar Wolf, a solar installation company, defrauded approximately 70 households by requesting funds then not performing the installation. Of the 70 households, 19 households had received approvals through the Old Kings Highway District Committee. These approved plans have not changed since that approval. Other households requiring further action are at the bottom of the list. Since May 2022, these homeowners have been moving through various legal matters to attempt recovery. The State and Town have been working toward a solution to resolve the homeowners' issues. In October of 2023, the Town, and MassCEC (Massachusetts Clean Energy Center) executed an agreement to work together toward resolving the homeowner issues. The Town has been coordinating communications with the homeowners, confirming the client list among other steps. MassCEC, since October has been working with SunPower and Incite Energy toward providing relieve for the households impacted by Solar Wolf. Described in its simplest form, the unique program titled "Yarmouth Assistance Program" will provide installations and cover costs already paid to Solar Wolf. Because of the Solar Wolf issues, and the resulting program interruption, none of the homes with valid OKH approvals were able to proceed. Therefore, the request is that the households with previous OKH approvals are exempt from the requirements for an extension and as a result will be extended for one year from April 11 h- 2024. With your approval, the attached list of 19 homes that have permits regarding the Old Kings Highway Commission will be allowed to proceed with the understanding of an Exemption that will allow a one-year extension from April 11 ', the beginning of the Yarmouth Assistance Program. Such extended approvals are understood to be in keeping with the original approval with no planned changes. Sincerely, William J. Scott A, evq;L TOWN OF YARMOUTH s '21SEi J.7A1�1 ).:0 f RD, - 1146 ROUTE 28, SOUTH YARMOUTH MA 02664-4451 Telephone (508) 398-2231 Ext 1292-Fax (508 i 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a (:ertificate of Appropriateness under Sevtion 5 of Crrapter 4fff TM11#71W amended fcr proposed work as described below & on plans, drawings, photographs & other supplementai Info accompanying this application PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Categories That A I Indicate type of Building Commercial V Residential 1) Exterior Buildin Construction: New Building El Addition Iterations Reroof DGarage Shed 12 Solar Panels Other I - — ECO Y ED 2) Exterior Painting Siding Shutters El Doors Trim 00ther: 3) Signs/Billboards El New Sin Change to Existing Sign 4) Miscellaneous Structures: Fence Wall nFlagpoli? IIPool IIOther. 'tdU i Please type or print legibly: Address of proposed work 27 Pine St MaP/Lot # 123.4 Owner(s) Daniel Long Phone # 571-228-3490 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address 27 Pine St. Yarmouthport, Ma 02675 Email dlong88635@gmaii-com Agent/contractor Solar Wolf Energy Mailing Address 771 Washington St Auburn, Ma 01501 Year built 1994 Preferred notification method 1:1Phone Email Phone #. 508-839-2222 Email alisha.v@solarwolfenergy.com Preferred nr,hfi.::atiun method PhoneEmail Description of Proposed Work: Installation of a 9.04kW roof mounted solar array using 27 SPR 335W panels with built-in microinverters and a SMART meter Signed (Owner or agent)' Date r'_ } --- Ownerlcontractoflagent is aware that a permit is required from the Building Department (Check other departments, also) If application is approved, approval is subject to a to day appeal period required by the Act This certificate is good for one year from approval date or upon date of exp ration of Building Permit whichever date shall be later All new construction wit be subje Ft to inspection by OKH OKH-approved plans MUST be available on -site for framtions For Committee use only: V_ Approved Approved with Modifications Denied Rcvd Date` 4 Amount ,f Cash1CK # Rcvd by 0� 45 Days: Date Signed -(,I i-7(tirli 1 Reason for Denial. SFp 13 Yq Signed X1 E 1 APPLICATION #-�5 V)� t o�Y TOWN OF YARMOUTH gp�Pjq o, - fy 1146 ROUTE 28, SOUTH YARr14UUT11, MASSAGE! USETTS 42664-4451 �. ; ,ti Telephone (508)-398-2231 Ext. 1292 I+Kx (S08) 398-0836 'SEf 3 j OLD KINGS HIGHWAY HISTORIC DISTRICT COMMIT VA0,._ WAIVER OF 45—DAY DETERMINATION The applicanvapplicant's agent understands and agrees that due to the current declared National and State public health emergencies the determination of our Application for a Certificate of Appropriateness.'Demolitioii.!F cemption may rust be made within 45 clays of the filing of such application. I'he applicant agrees to extend the time frame within which a determination is to be made as required b) the Old King's l iigliwa% Regional I listoric District Act. SECTION 9-lbleeti►tgv, Hearing, v, Timefor Making Deter►ui► atiotu -As.won a.v convenient afier such public hem-ing; but in ant° event ►t�ilhin fort -five (45) dal..% offer the fliag of application, at- iviihin such f rther time av the applicant vhedl allo►r� in writing, the Committee shall make a determination can the application. " Applicant understands that the review of this application will he scheduled as soon as the .situation allows. Applicant;Agent Name (please print): AJ, V, AppIicant.-Agent signature: 6L Date: W4 Application 312020 SOLAR wo�F ApPA E �r� ERGYinc. SeP' 3 Zoz� J Douglas, MA 015U Office 1: (888) 878-4396 Office 2: (508) 839-2222 Owner Authorization Form We the undersigned, hereby authorize Solar Wolf Energy Inc to act on our behalf in all manners relating to the installation of a photovoltaic system at the location __2Z pine St Yarmouth Port. Ma 02675 . This includes but is not limited to financing paperwork, interconnection documents, building & electrical permit applications, applicable rebate applications, etc. This authorization is valid only for items pertaining to the installation and commissioning of a solar power system to be installed by Solar Wolf Energy Inc. Signed under the pains and penalties of perjury. xqm"�/ d'7 Signature of owner 08/17/2021 Date 0.-y y TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 1 146 ROUTE 28. SOUTH YARMOUTH. MASSACHUSETTS 02664-4451 Telephone (508) .398 2231 Ext.1292 Fax (508) 398-0816 STATEMENT OF UNDERSTANDING CHANGES TO AN OLD KING'S HIGHWAY APPROVED PLAN As property owner/contractor/agent for construction at Map.. -'Lot _ + ._ CIA # 'i . Approval Date: I certify that I understand the following requirements regarding any changes that may be required for this project: In accordance with paragraph 2(a) of section 1.03(General Procedures) of the OKH 972 CMR Rules and Regulations: Only minor changes may be approved by the Committee without the filing of a new application and a new hearing. Minor changes include alterations that can be done without a detrimental impact on the overall appearance of the project such as altering a single window or door change or a minor change of colors. All minor changes by amendment will require the local Committee's or its designee's approval. All changes to previously OKH approved plans require notification to and approval from the local OKH Committee. Change requests must be submitted to the Committee in writing on the appropriate request form, which may be obtained from the OKH office. All change approvals must be obtained before incorporating the change into the project. If the change has been implemented prior to receipt of OKH approval, a Minor Change approval or Certificate of Appropriateness application for the revised plans is still required and will result in a doubled filing fee for the appropriate category of work. Failure to comply with the above statements will result in the Building Department issuing a stop -work order or delaying issuance of an Occupancy Permit or final inspection approval. I have read and understand the above statements. 2-"-� Date: z5 Z) Signed: (Owner,"Contractor/Agent) Signed: / 0�--/z / (Chairman, OI King's Highway Committee) H '.OKH COMMITTEEWpphcation FormstStatement of Understanding 2015-door Updated IV2015 TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE ABUTTERS' LIST Applicant's (Owner) Name: f/�(1( Lori L Property Address/Location: _ 7 0ru_ 3+- Hearing Date: Notices must be sent to the Applicant and abutters (including owners of land on any public or private street or way) who's property directly abuts or is across the street from the Applicant. Please provide the Assessor's Tax Map and Lot numbers only. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtain ng the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website- www.yarmouth,ma_us Map Number Lot Number Applicant Information: 2 Abutter Information: AZ3 � (0 Z I is 3 5 23 2 12 3 3 23 Z-/3 /2 Application #: 0 A 4 a_zo11e 3 1231 1431 1 1 KELLY MARGARET D P O SOX 282 YARMOUTH PORT, MA 02675 1231 1441 1 1 SHARP SARAH M SHARP WILLIAM B 30 PINE ST YARMOUTH PORT, MA 02675 1231 61 ! ! BRITT ELIZABETH L CIO BOURDEAU STEPHEN R 68 SYLVAN RD NEEDHAM , MA 02492 1231 61 1 1 WAITKEVICH ADAM A WAITKEVICH DIANE M 11 GILBERT WAY MILLBURY , MA 01527 1231 41 1 1 LONG DANIEL LONG KAREN 27 PINE ST YARMOUTH PORT, MA 02675 1231 31 1 1 SWEET JANES CONSIGNMENT INC DHIMITER LAKO 120 WORCESTER ST WORCESTER , MA 01608 1231 21 1 1 NICKINELLO LOUIS JR NICKINELLO LESLIE A 39 PINE ST YARMOUTH PORT, MA 02676 1231 153.11 1 1 TOWN OF YARMOUTH _AND BANK PURCHASE 1146 ROUTE 28 SOUTH YARMOUTH, MA 02664 Please use this signature to certify this list of properties directly abutting and across the street from the parcel located at: 27 Pine St., Yarmouth Port, MA 02675 Assessors Map 123, Lot 4 Andy Ntichado, Director of Assessing August 30, 2021 �eX�k °1/1/2021 - � - .�����7, . . . - ��y� \J - . 1 11 »d ��� • . � .\. . .` I-" A 4e ��� \\Z, :��\ , wo Tf*; in -A iF � 5 F v•'ir� �T a+' '7 �•,yl • #y: i -� r�% y 1 � �+_ - 'i .{`'�4�•w-., yi. •� iw. � � ir� �s�i'�y�.�t _ _ �� 'I µ: mil. .4r Y 41• . Im pr +.1� x T � ,�.i• hd. 2 rt ul 4 F - !.' t C A,r dl ... j. Y f I fir A r - 5, x'A AN,\ ] \ �� � / � �� , / tp J.-Miiim 0 F I # i kti Design -Driven Advantages 411 module aesthems and effciern-y Unmatched module reliabili.y' No electrolyt=c capacitors 25-year Combined Power and Pro_iuct Warranty California Rtile 21 Phase°7_compliant Maximize va ue for Roof Size system for roof, not string inverter Opt mize performance of ear h modu P Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive comm,-s t,: ing Component of Complete System Built for use with SunPower' lnvisiMountl" and the SunPower Monitoring System (PVS5.;) Superior system reliability and aesthetics X SERIES AP OVED ?E 3 1021 Optimize System and Installation Efficiency SunPower"'AC rrodules, which include a factory integrated SunPowe+ microinverter, provide a revolutionary combination of h:glt efficiency, high reliability, and module level D: -to-AC power Conversion, Designed specifrcally for use with SunPower InvisiMount'"I and the SunPower Monitoring Systern. SunPower AC modules enable rapid;nstallation, best- •n t lass system aesthetics, and intuicve visibility wto systern per forroance. Al this comes with the best Combined Power and Product Warranty in _l'e industry Grid Support Utility-nteractive Smart Inverter S,rnPower's new Type D AC module is UL tested and Certified to UL 1741 SA and provides advanced smart inverter fui.ctions SunPower Type D X modules are fully compliant with the Californ;a Role 21 Phase 1 requirements, and the Rule 21 grid profile is easily set during con'missionirlg with SunPower PVSSx monitoring hardware. sunpower.com SRD Profile (default settings) min. / nom, / max, .-.------.------------ ----- Frequency (Hz) 59.5 / 60 0 160,5 Power Factor 0.99 / 1.00 / 1.00 0.8ad:. .5 le/;y1,00'/ D:85 89, _. _ .. _ . .war Reactive. Power �� V 6Y1 ,Ar Voltage -- @240 V 21cl .2-/ 40 / 64 V r . 0208 V - - 183.7,2081228.8 V _._.._. KIvlax. Current 1 @240 V .1.33 A @208 V . 1.54 A @240 V--96.0% — 7� DC/AC CEC Conversion Effie ency @208 V 95,596 Max, 4:nits Per 20 A Branch Circuit @240 V 12 (single phase) J @208 V 10 (two pole) Wye Power _ - —i 320 V No active ph a balancing,fo.r 3 phase Installations -- — J. A, SPR-_X21-335-BLK-D-AC 5PR-X20-32_7-D-AC Nom naI Power° (Pnom),A 335 W 327 W Power Tolerance ' ! +5/-•096 +5/-A Awg. Panel Efficiency' ':..1 21,01W 20.4% Temp. Coef. (Power) -0,2996/'C - - " Three bypass diodes Shade Tolerance; ..�Integrated, mod ule-level:rnaximum power point s3a track; � -- - Operating Temp.. z2400 F to;}185o F (-40RG to +.85o C} Max. Ambient T&6p. ' ' 122' F '(50' C) Max. Load O; Wind.'62 psf, 3000 Pa. 30_Nlm2 front & back 5nori',125 psf 6000 Pa, 61:1 kg/m2 front 1mpa.t ResistaResistanCe 1(inch'(25 mm} diameter flail at 52 mph (23 m/s) Solar Cells 1'f; 496 Monoc"rysta'line Maxeon Gen III _ �Tv c' H,gh4ransmssion tempered glass with anti Front G'ass Al f . reflecdi e coating _ Environmental Ratin 7�Outdoor rated _ Class )'black anodized (Flighest AAMA ratinai Weight f" ' 45.5 ibs (20.6 kg) Recommended Mai I,• Module Spacing 5'1:3 in.,(33 mm) - ighest of over 3,2,OD stkcon -olar panels, Photon Module Survey, Firb: 2014 41 rank in'PV Module burab hly Iniiiative Public Report.' Ffaunholer,CS: Feb 101.3. Fps,..ut of )e top eight largest manufacturers were tested. Campeau, z et at -S[ nPower Module nradatlon Rate,' SunP;wer while paper, Feb 2013 See www.5unpo.Zrconvfactc for detail. -actory. set to 1547a-20i4 defaul['setlings: CA Rule 21 default settings profile •.et during ommiSlivning, See the E4wnox. Frisfplladon Guide #5 r8101 for mon' 6.i6rmation Aardard Test Condition; (1000WIm= Tradiancr,FAM 1.5 25' C1 P—_-'761ibretion 5[dndard 0,10%4$rrent,VcCC�Wandioltagq,'AllDcv'oltage:sftilty6ntalneA4ikr,themodule. 3a'"ed : -i average of measured power valves dorinR production 4. 4 ie@www,sunpower.conVfac[s fori thole refermcr mfortrlation CA.Rule 213 min. /;nom. / max: 60.0'/t60 5: Warranties 25-year Ilml _ed power war'anty f 25^year limited product warranty UL listed to UL 1741 SA SRDs• IEEE 1547 2003. IEEE 15a7a 2014. CA Rule 21 Pliase 1 i PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (ioad break disconnection) UL 1741 AC Module (Type 2 fi,e rating) Certifications Enab es instalation in accorda•1ce with. NEC 690.E NEC 690.12 Rapid Shutdown ( nslde and outside the array) NEC 690.15 AC Connectors. 690.33(A) - (E)f 1) FCC and ICES-003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bond ng Class Afire rated _ PID TF Potential -induced ftradafon free 1107 mm M6In] I 1558 mm i.r t6131) it T 1046 mm 'g=. 141.21n] NOV (S2 fnl Please read tro safety and Installation tr131rtict16ns for detail PIKE �c�mue aao�nrantnur rmrOYAi Lem gem Abdul- I'l PA, , I ' k: Tip 2 - ��> . . - . . . � G*(�� . ��• . ■; 0 0 0 � . � \ � / , � �2 !,t ,}\��/i � ��} \/` JL rr t 'A Y R ov SEP 1 3 20 YAFiMO f G' HIGFf i i f r el3p6L , M.A :�� �� �`.� t ♦ ,fit � � re a{flkM1x�' ' 1� • r 1' 'IMi 4. .40 wd IL L R fir' ���'�Y� . � y� �� r J• •�,,* } � 'ft S ; . f a - s�,. 4 aF •4�•d pf i -� � .1 �- •ram I •� � at i i �. 7`' a '•. Eli � + '*� `1 �� ��L�: .f .i,� �� 4LPIPa� .�+ � + tit i •� yr'r� �y y f �� ,f• �1`� �'r �}•.`''1*f!>r-4'•�'•f "' I f * ,y ,�. � ,�,+` r;• IV �k !� �7t1 j:•f a' r ; •"" rJi � �`�w n4 �� ty� • r �, 5�+� � 1: �i + 1` �,�• � � } L :.x����. L IV- f .,�,�yJF ti . kf� a ` I {ll�t {.'�•.i x. + .151 .��• i 14 .' i���} } J w 1T , •% • E , F' . • • ` S 7j . • Sy Design -Driven Advantages #1 module aesthetics and efficient.; Unmatched module reliability' No electrolytic capacitors 25-year Combined Power and Product Warranty :.:. California ROi 21 Pha .E: 1 corml.ant Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed installation Factory -integrated microinverter Robust, double locking AC Connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than campe-Erg systems Intu4uve con Component of Complete System Built for' use with SunPower-1 InvisiMounC" and the SunPower Monitoring System (PVS5x) Superior system i elrability and aesthetics �7 40. 11/11I{ ��03 _ a PPR VEID SEP 13 021 YAAeen,. r Optimize System and installation Efficiency SunPower-OAC modules, whr I- in: hide a factory integrated SunPower microinverter, provide a revolutio+)arycombination of high efficiency, high reliability, and module level DC to AC jir,wer conversion. Designed specifically for use with SunPower, I111Vt51M0Un[ M and the SunPower Monitoring System, S; inPower At. inodures enable rapid installation, best - in -class system aesthetics, and nit iitive 6sibility in,o system per All this comes with tI-e best Combined Power and Pre.citsc_ Warranty in .he industry, Grid Support Util-ty•Interactive Smart Inverter SunPower's new Type D AC module is U. tested and certified to UL 1741 SA and provides advanced smart inverter fom-tions SunPower Type D A; modules are fully compliant w;th the California Rule 21 Phase 1 recluirernents, and the Rule 21 grid profile is easily set during cornmisss{aning with SunPower PVS5x monitoring hardvwife sunpower.com *t" -L- - 3 ir SRD Profile Frequency (Hz) -- - r Power Factor , Reactive Power (default settings) min, / nom. / max. - - 59 5 / 60.0 / 60.5 0.99. / V 00 / 1.00 Voltage -.... ... 2 @208 V li!I 1 Max. Current @240 V@208 V -- DC/AC CEC Conversion Efficiency @240 V @208 V Max Units Per 20'A'Branth C-rcuit @240 V @208 V Power.....n..-----�--- No active phase balancing for 3 phase installations + _ 5PR-X_2.1-335-BL_K-D_-AC 5_PR-X20-327-D•AC Nominal powera(Pnom) 335 W 327 W Power Tolerance +5/-0% +S/ 0% j Aug Pane! Etficiencys 21.0% 1 emp Coef. (Power) — _20.496 -0.29%/°C - -- 83 / 208 / 228.8 V 1.33 A _ 1.64 A _ 96.0% 95.5% 12 (single phase) 10 (two pole) Wye 320 W. 320 VA Three bypass diodes Shade Tolerance Integrated module -level maximum power pant track ng $ keratin Temp,_ -40u F to +1851 F (-40° C to +850 C) Max. Ambient Temp. 122° F (50' C) Max . oad _ Wind: 62 psf 3000 Pa.305 kg/ml front & back _ Snow: 125 psf, 6000 Pa, 611 kglm2 front Imyact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s): Solar Cells 96 Monoe statline_Maxeon Gen III ' Front Glass High -transmission tempered glass with anti - reflective coating l Environmental Ratting Outdoor rated F: ame Class 1 black anodized (highest AAMA ratin ) _Weight_ _ ._ .,. _ 45.5 ibs (20.6 kg) Re:,ommended Max. 1 3 in. (33 mm) Modu a S"c ng -ighest of '�r 3.200 silicon vtifai panels. Photon Morul. ".urvey, Feb 2014 11 rank in _r"; Module [curability Initiative Public Report'-raunhofer CSE, Feb 2013. Five out of •e top right largest manufacturers were tested. Campeau, Z. et al.'SunPower Module egr,rlation atn. SunPo+rerwl-lie paper. :-eb2013 5eewvwwrpower.corntfactsfordetail acLory set to 1547a-2014 default settings CA Rule e 1 defa-A :eltings profile A during arnmissionir& =ix thr rquino{ lastollor•.:n Gulde #51.r'Of for more mformm ion itandardTe:tCunditiom:1O'-9+W/mzin=diancp,AMt':.JVC1.Nii-i calibrAnonstandard: U,W currem. LACC5. FF and •Yoftage. All EC voltage is fully cont7tned with nth, module �ascri on ? V eraite of r'reasured rower values dunra production wwwsunl 1: •, comAfaw for i'.ora •'eLsrerif'e infonnation e extended datasheet' www.sunpowef com/datasheets. CA. Rule 2,3. min / nom, � max. 0.85 lead. 11.00 40.85 lag, t3 69 Var• - - warranties 25=yearl;m.tedpower warranty 25-year I imited ,,^.roduct warrant-__ UL listed to UL 1741 SA i SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables I (load break disconnection; UL 1741 AC Module (Type 2 lire rating) Certifications Enables installation in accordance with-. • NEC 690.E l PIDTest 11071 t43.6 X1 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 69015 AC Connectors, 690.33(A) - (E)(1) FCC and ICES-003 Class B When used with Inv:s Mount racking (UL 2703), Integrated grounding and bonding Class A fire rated Potential -induced de}radation free 1566 rnm [613 In] ll� 1046 mm t412 Nj Measa read the safetyand installation Instructions for detail! Eg �f `- L p2 Mg ��icMoau ugluroert�r naan4 rvwoiruioarMr USM MO&Ar AM P&6"w: IM 2