Loading...
HomeMy WebLinkAboutDrawing No. A0.1-Project Info-Dwg. List-Symbols & General NotesAPPLICABLE CODES GUIDELINES AND LAWS: BUILDING CODE SUMMARY Massachusetts State Building Code, 780 CMR, 9th Edition • International Building Code 2015 (IBC) INTERNATIONAL EXISTING BUILDING CODE (IEBC) TO EXISTING WAREHOUSE & DISTRIBUTION CENTER PRO EC : ALTERATION International Energy Conservation Code 2018 (IECC) 225 WHITES PATH UNITS 2 & 3 LLC • Massachusetts Amendments (MA) LOCATION: 225 WHITE'S PATH, SOUTH YARMOUTH, MA 02664 Massachusetts Architectural Access Board (MAAB) American Disabilities Act (ADA) • MGL C148 Section 26G (MGL C148 26G) Re: Sprinklers REGULATIONS AND STANDARDS: APPLICABLE SECTION TABLE PAGE NO. REQUIREMENTS / DESIGNATION PROPOSED ITEM CODE PUJSEGROUPCiASSIFICATION-L 311.2 51Sl - MODERATE HAZARD STORAGE (WAREHOUSE & PACKAGE HANDLING) IBC / MA 311.3 51 S2 -LOW HAZARD STORAGE (PARKING) MIXED USE 303.3 42 B - OFFICE (ACCESSORY USE) CONSTRUCTION TYPE IBC 602.2 — 113 TYPE IIB - (UNPROTECTED) ALLOWABLE BUILDING HEIGHT IBC 504.1 504.3 504.4 98, 99 75 FEET ALLOWABLE 3 STORIES (SPRINICERED) (S1 - MOST RESTRICTIVE) NOT REQUIRED PER IEBC OF USE) ALLOWABLE BUILDING AREA IBC 506.1 506.2 102 ALLOW AREA 70,000 GSF (FABLE 506.2) (NO CHANGE SPRINKLERED BUILDING (B+S1 - MOST RESTRICTIVE) AUTOMATIC FIRE SUPPRESSION SYSTEM IBC 903.2 IBC: 210.214 MA: 59,60 APPROVED AUTOMATIC SPRINKLER SYSTEMS IN NEW BUILDINGS AND STRUCTURES SHALL BE SPRINKLER SYSTEM REQUIRED PROVIDED IN THE LOCATIONS DESCRIBED IN AND PROVIDED. SECTIONS 903.21 THROUGH 903.2.12 (IBC) EXISTING SPRINKLER SYSTEM TO BE RENOVATED FOR NEW THROUGHOUT ALL BUILDINGS W/S:2 PARKING USE AND LAYOUT, MA 903.2 903,2 (NIA) GARGAE REQUIRES AUTOMATIC SPRINKLER SYSTEMS (MA) MGL 148 SUB -SECTION 26G MGL C148 SECT 26G EVERY BUILDING OR STRUCTURE INCLUDING ANY MAJOR ALTERATIONS AND ADDITIONS THERETO, WHICH TOTALS, IN THE AGGREGATE MORE THAN 7,500 GROSS SQUARE FEET IN FLOOR AREA OCCUPANT LOAD IBC 1004,1 1004:1,2 251 OCC PARKING: 200 BUSINESS AREAS: 100 GSF// OCC FIRST FLOOR 577 0CC TOTAL MINIMUM EGRESS DOOR WIDTH I8C 1010,1.1 _ 260 117 3T MIN. WIDTH (IBC) 34" MIN WIDTH (MAAB/ADA) ALL EGRESS DOORS ARE 34" WIDTH MINIMUM MAAB/ADA 26.5 ABBREVIATIONS SYMBLOS AB. ANCHOR BOLT HGT. HEIGHT NORTH ARROW A.F.F. ABOVE FINISH FLOOR H.M. HOLLOW METAL 77 ACT. ACOUSTICALTILE INSUL INSULATION SECTION INDICATOR ALUM ALUMINUM INT. INTERIOR IM LETTER IN TOP HALF OF CIRCLE INDICATES THE SPECIFIC SECTION. ANOD ANODIZED JT. JOINT (A101 THE NUMBER AND LETTER IN THE @ AT LAG. LAG BOLT BOTTOM HALF INDICATES THE DWG. No. WHICH THE SECTION APPEARS BSMT BASEMENT LAM. LAMINATE BIT BITUMINOUS LAV. LAVATORY BLK BLOCK L. LENGTH +45.5 NEW SPOT ELEVATION BLKG BLOCKING MFR. MANUFACTURER 45.5 E EXISTING SPOT ELEVATION BOTT BOTTOM M.O. MASONRY OPENING '--J 45 CONTOUR LINE B.O.W BOTTOM OF WALL MAT. MATERIAL (1r COLUMN COORDINATES & BM BEAM MAX. MAXIMUM REFERENCE GRID LINES BLDG BUILDING MECH. MECHANICAL CPT CARPET MIN. MINIMUM — _ — _ — LEVEL ELEVATION CSMT CASEMENT MTD. MOUNTED CK CAULK(ING) NO. NUMBER t Ref CLG CEILING NOM. NOMINAL V INTERIOR ELEVATION NUMBERS CLOS CLOSET N.I.C. NOT IN CONTRACT 1 A1or 1 INDICATE ELEVATION NUMBER COL COLUMN N.T.S. NOT TO SCALE & LETTER INDICATES THE CONC CONCRETE O.C. ON CENTER 1 Ref DRAWING WHERE THE CMU CONCRETE MASONRY UNIT OH. OVERHEAD Ref ELEVATIONS ARE LOCATED CONST CONSTRUCTION OPNG. OPENING View Name ELEVATION TAG CONT CONTINUOUS PINT. PAINT C.) CONTROL/CONSTR. JOINT PTD. PAINTED Room name ROOM TAG CTSK COUNTERSUNK PNL. PANEL 101 DET DETAIL PART. PARTITION DIA DIAMETER PL. PLATE tot DOOR TAG DIM DIMENSION PLAS. PLASTER WINDOW TAG DR DOOR RLAM. PLASTIC LAMINATE DH DOUBLEHUNG PLBG. PLUMBING 1i WALL TYPE DRWR DRAWER PLYWD PLYWOOD DWG(S) DRAWING(S) P.T. PRESSURE TREATED N so 00' oo• E PROPERTY LINE DF DRINKING FOUNTAIN Q.T. QUARRY TILE Distance TAG DW DISHWASHER REQ'D REQUIRED Name PROPERTY TAG I ELEC ELECTRIC(AL) REF. REFIGERATOR Area ACRES EL ELEVATION REV. REVISIONS ELEV. ELEVATOR R. RISER � REVISION MARK EMER. EMERGENCY R.D. ROOF DRAIN EQ. EQUAL RM. ROOM CONCRETE EXIST EXISTING R.O. ROUGH OPENING OR EX. SECT. SECTION BRICK E.J. EXPANSION JOINT SCHED. SCHEDULE EXP, EXPOSED SPEC. SPECIFICATIONS EXT. EXTERIOR SL SIDELIGHT CONCTRETE BLOCK FIN. FINISHED STD. STANDARD F.A. FIRE ALARM S&P SHELF&POLE ` ` PLYWOOD F.B.O. FURNISHED BY OWNER STL STEEL F.E. FIRE EXTINGUISHER SUSP. SUSPENDED�11L14 FL. FLOORING) THK. THICK STEEL FLUOR. FLUORESCENT FT. FOOT T&B. T&G TOP&BOTTOM TONGUE&GROOVE ROUGH LUMBER FTG. FOOTING T.O.F. TOP OF FOUNDATION FND. FOUNDATION T.O.W. TOP OF WALL - M FINISH LUMBER FURR. FURRED(ING) T. TREAD GALV. GALVANIZED TYP, TYPICAL G.C. GENERAL CONTRACTOR UNFIN. UNFINISHED RIGID INSULATION GL. GLASS/GLAZING V.I.F. VERIFY IN GR, GRADING VIN. VINYL BATT INSULATION GWB. GYPSUM BOARD VCT. VINYL COMPOSITION TILE HDBD HARDBOARD VWC. VINYL WALL COVERINGr�— OE— HDWD. HARDWOOD WC. WATER CLOSET EARTH HVAC. HEATING, VENTILATING, & W. WIDE/WIDTH AIR CONDITIONING W/ WITH GRAVEL HDWR. HARDWARE W/O WITHOUT W.W.M. WELDED WIRE MESH COMPACTED FILL WD. WOOD F v� - u JUN 01 2022 HEALTH DEPT. E0.1 ELECTRICAL NOTES AND LEGENDS E1.1 ELECTRICAL LIGHTING FLOOR PLAN E2.1 ELECTRICAL POWER FLOOR PLAN E4.1 ELECTRICAL PART PLAN E5.1 ELECTRICAL DETAILS E6.1 ELECTRICAL SCHEDULES E6.2 ELECTRICAL SCHEDULES E6.3 ELECTRICAL SCHEDULES E7.1 ELECTRICAL POWER RISER DIAGRAM FA0.1 FIRE ALARM RISER, NOTES AND SYMBOLS FA1.1 FIRE ALARM FLOOR PLAN STAMP: I g No. 10563 p T BARNSTABLE. y MASS. �A�Ts`l F M ASgP 0 0 U O O ` 3 a LO oo d C U C � N rn -J C O 1 U a Q N W cw NM o $ 0 ix W J Z W J 0UM N ZON ~ =O x ~ W Q G Uj O_3o. �5 F..-OAS (All Ln 1[2�- C5~ N< = _ 4 Q N TITLE: PROJECT INFO, DWG LIST, SYMBOLS & GENERAL NOTES DATE ISSUED: 04 - 25 - 2022 REVISIONS: No. Description Date DRAWING NO.: AO, I ®Colaryst ArcNlectue! InteAabNo. ,V t"s reserved. Tn CcWIMts to- designs a0 dFoWngs are the plowri :1"ArcNtc / Welds, Inc. No use a RPro"M of this rcaisful Is Pe led Y*W e>tpressed wtAten consent. 7w+.""