Loading...
HomeMy WebLinkAboutDrawing No. P6.0 Plumbing Schedules and DiagramsJUN H EALTH oepr STAMP: PLUMBING SPECIALTIES SCHEDULE SYMBOL MANUFACTURER/ DESCRIPTION COMPONENTS AND' MOUNTING REMARKS SYMBOL MANUFACTURER/ DESCRIPTION COMPONENTS MOUNTING MODEL NUMBER ACCESSORIES HEIGHT I MODELNUMBER AND ACCESSORIES HEIGHT REMARKS CO-1 JR. SMITH CLEANOUT: 06 SOI-1 ZURN FOG-CEPTOR SANDIOIL PROVIDE WITH MODEL # DUCO CAST IRON MODEL # INTERCEPTOR: EXTERNAL FLOW 4420C CAULK FERRULE WITH Z250H 250 GALLON CONTROL DEVICE, CAST BRONZE TAPER ENGINEERED SIZE FOR 100 GPM, THREAD PLUG. FIBERGLASS WITH 20"0 DUAL MANWAY H-20 RATED FIBERGLASS BOLTED AND GASKETED FRAMES AND COVERS - AND (2) THIGH X 20"0 EXTENSION COLLARS. FC41 JR. SMITH FLOOR CLEANOUT: FLASHING CLAMP #6 TD-1 JR. SMITH TRENCH DRAIN PROVIDE WITH ADA #6 CAST IRON BODY, MODEL # FOR CARPETED MODEL # $'STEM; COMPLIANT SLOTED 4023S-PS-U ROUND ADJUSTABLE FLOORS 9878 10" WIDE PRECAST GRATE AND VANDAL SCORIATED POLYESTER PROOF SCREWS POLISHED BRONZE CONCRETE, PROVIDE WITH 9878 TOP, FLANGE INTERLOCKING CATCH BASIN. GASKET CHANNEL, 0.5% INSIDE, CAULK SLOPE, INTEGRAL PROVIDE WITH ' - - OUTSIDE. DUCTILE IRON EDGE STANDARD PTRAP VANDAL PROOF & RAIL AND GRATES, AND TRAP PRIMER BRONZE PLUG LOAD CLASS E CONNECTION. FLD-1 JR. SMITH FLOOR DRAIN: VANDAL PROOF - #6 TP-1 PRECISION PLUMBING TRAP PRIMER: ELEC: 120V/6W/lPH INSTALL V ABOVE #2,4 MODEL# CAST IRON BODY, GRATE "PRIME -RITE" MODEL INTERNAL THE FLOOR FOR 2010C-U-P050 ROUND ADJUSTABLE # PTS-# VACUUM EVERY 20' OF CW NICKEL BRONZE REFER TO THE BREAKER AND MAKE UP RUN. STRAINER, NUMBER OF DRAINS BACKFLOW CONTRACTOR TO FLASHING COLLAR SERVED ON PLAN. PREVENTER UNIT. PROVIDE FINAL - AND TRAP PRIMER - 1/2" INLET AND INSTALL HEIGHT CONNECTION AND OUTLET PER FINAL SHOP SEDIMENT BUCKET DRAWINGS LAY OUT. GCO-1 JR. SMITH GRADE CLEANOUT: HEAVY DUTY FOR #5 T-1 ZURN PROCEPTOR TIGHT TANK: PROVIDE WITH HIGH OR LOW MODEL # CAST IRON BODY, UNFINISHED AREAS. MODEL # FIBERGLASS GREENTURTLE HIGH RELAY 42504264 ROUND ADJUSTABLE DUCO CAST IRON EHT1000 REINFORCED LEVEL MONITOR CONTROLLER SCORIATED CLEANOUT AND PLASTICS, LINED FOR HOLDING 120V, 50-60HZ, POLISHED BRONZE DOUBLE FLANGED INTERIOR, TANKS INCLUDING: 5W TOP, FLANGE GASKET HOUSING WITH HEAVY ANCHOR BOTTOM, INSIDE, CAULK DUTY SECURED 1000 GALLON REMOTE PANEL HIGH OR LOW OUTSIDE. SCORIATED CAST IRON '.. CAPACITY, H-20 120V, 4.8VA MAX LEVEL SWITCH, VANDAL PROOF & COVER WITH LIFTING RATED COVER, SET TO DEFAULT BRONZE PLUG DEVICE. CAST IRON PIPING, SETTINGS 24"0 36V, 25MA MANWAY. 1�B-1 WOODFORD HOSE BIBB: 3/4" THREADED 18" ABOVE #3,4 Wco-1 JR. SMITH WALL CLEANOUT: VANDAL PROOF - #6 MODEL # BACKFLOW HOSE CONNECTION FLOOR MODEL # DUCO CAST IRON, SCREWS. 26 PROTECTED BRONZE 4402C-U SPIGOT FERRULE BODY, LOCKING NUT CAST BRONZE AND KEYED THREAD PLUG, CYLINDER STAINLESS STEEL ROUND COVER AND SCREW. I JI-1 GUY GRAY ICEMAKER BOX: PROVIDE WITH WATTS #3 MODEL#88164 STAINLESS STEEL ICE MODEL#LF-007 MAKER BOX WITH BACKFLOW PREVENTER QUARTER TURN BALL ON 1/2-CW VALVE AND CONNECTION BACKFLOW PREVENTION DEVICE REMARKS: 1. NOT USED, 2. THE TRAP PRIMER SHALL BE INSTALLED A MINIMUM OF 1 FOOT ABOVE FINI�HED FLOOR FOR EVERY 20 FEET OF PRIMER LINE. 3. PROVIDE EACH HYDRANT WITH A LOOSE KEY, CONTRACTOR SHALL VER17 WALL THICKNESS. 4. PROVIDE ISOLATION VALVES AT THE SUPPLY PIPE CONNECTIONS. 5. PROVIDE AN AIR GAP FITTING ON THE DRAIN LINE. MOUNT AT A SUFFICIENT HEIGHT TO ALLOW PROPER DRAINAGE. 6. REFER TO FLOOR PLANS FOR SIZES. 7. MAINTAIN MINIMUM OF 9 12 INCHES CLEAR ABOVE INTERCEPTOR FOR STRAINER REMOVAL. 8. MAINTAIN MINIMUM OF 812 INCHES CLEAR BELOW INTERCEPTOR FOR STRAINER REMOVAL. PROVIDE UNIONS AT INLET AND OUTLET PIPE CONNECTIONS. 9. PROVIDE LOW FLOW BYPASS AS REQUIRED BY THE MANUFACTURES LITERATURE FOR MINIMUM FLOW RATE OF .5 GPM. 10. PROVIDE AN AIR GAP FITTING ON THE DRAIN LINE. MOUNT AT A SUFFICIENT HEIGHT TO ALLOW PROPER DRAINAGE PLUMBING FIXTURE CONNECTION SCHEDULE FIXTURE WASTE VENT COLD WATER HOT WATER TEMPID TYPE CONNECTION CONNECTION CONNECTION CONNECTION WATER FLOOR DRAIN 2" 1 12" 12" HOSE BIB (CW ONLY) 12" ICE MAKER BOX - 12" TRENCH DRAIN 4" REFER TO PLANS 12" NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS FOR ALL PLUMBING FIXTURE MOUNTING HEIGHTS. 2. ALL PIPE TRAPS AT SINKS AND LAVATORIES SHALL BE CHROME PLATED BRASS. U J Aqp. O� JAME3L,.ME .(�9P 691I9R v Q c (� Qz ® C U) C U N U O > Q Q O W a L= 2 CL Q U } n c` 0 Q W F- N �j CND OD W M H c) (n M 0 N a 0 N w W F W Z� y/ O1. N Q x Wm a-_ r lee. W Op f =2 O N LLI ,^�,^ W W N I TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (IN INCHES) FLUID OPERATING TEMPERATURE RANGE AND USAGE (°F) INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES) CONDUCTIVITY BTU' IN.!(H'FT^2 ° °F)W MEAN RATING TEMPERATURE <1 1 70 < 1-1/21-12 TO < 4 4 TO < 8 a 8 > 350 0.32 - 0.34 250 4.5 5.0 5.0 5.0 5.0 251 - 350 0.29 - 0.32 200 3.0 4.0 - 4.5 4.5 4.5 201 - 250 0.27.0.30 150 2.5 2.5 2.5 3.0 3.0 141 -200 025 - 0.29 125 1.5 1.5 2.0 2.0 2.0 - 105 - 140 0,21 -0.28 100 1.0 1.0 t5 1.5 1.5 40 - 60 0.21 - 0.27 75 0.5 0.5 1.0 1.0 1.0 <40 0.20-0.26 50 0.5 1.0 1.0 1.0 1.5 r D Q 3: 0 �u/ V) Li TITLE: PLUMBING SCHEDULES AND FOR SI: 1 INCH = 25.4 MM, °C = ((°F) - 321/1.8. - DIAGRAMS a. FOR PIPING SMALLER THAN 1-1/2 INCHES AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE b) BUT NOT TO A THICKNESS LESS THAN 1 INCH. b. FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED AS FOLLOWS: T= r((1 +t/r)K/k-1} DATE WHERE: ISSUED: 4/25/2022 T- MINIMUM INSULATION THICKNESS, REVISIONS: r= ACTUAL OUTSIDE RADIUS OF PIPE, No: I Description I Date It = INSULATION THICKNESS LISTED IN THE TABLE FOR APPLICABLE FLUID TEMPERATURE AND PIPE SIZE, K = CONDUCTIVITY OF ALTERNATE MATERIAL AT MEAN RATING TEMPERATURE INDICATED FOR THE APPLICABLE FLUID TEMPERATURE (BTU' i INN - FT^2 ° °F) AND k = THE UPPER VALUE OF THE CONDUCTIVITY RANGE LISTED IN THE TABLE FOR THE APPLICABLE FLUID TEMPERATURE. c. FOR DIRECT -BURIED HEATING AND HOT WATER SYSTEM PIPING, REDUCTION OF THESE THICKNESSES BY 1-12 INCHES (38MM) SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE b BUT NOT TO THICKNESSES LESS THAN 1 INCH (25MM). _ _Z.04 REFERENCE FROM INTERNATIONAL ENERGY CONSERVATION CODE (IECC) TABLE C403.2.10 t:-hbv ev^ 9 Services, me 128 Camegle Row, Ste.104 Norwood MA 02062 617.261,7161 cesew.00m DRAWING NO.: 2022053.00 P6.0 O Cat*w ArchAedure / Interbm, ft. Al riot, --w. The Copyrights to eA designs and drawhgs are the pmp" Catalyst ArdrAecMe / hMenus, Im. No use %rWo&xEw dads mmeml w pem w wtw eep-d wroon carwem.