Loading...
HomeMy WebLinkAboutDrawing No. A1.2 Proposed Office Area Floor PlanV W STAMP: R S T U U - -- - - - — 5 16'-0„ 2 77 FINS LIE, w A1.2 I `y� MASS. S 4 6 21 �q" rN F M ASgPG U Ut 3 Ala i I 1 PICK-UP q A3.1 i i 4 O15 Y NEW 51W GWB EACH SIDE ON 6" @'i I �o METAL STUD @ 16" O.C. PARTITION w o I EXISTING CMU WALL ', I o b I I q I NEW 12"W.x38"H. COUNTER � L? I 0 � Q C d D ,. B ...- o O EXISTING OPENING STEEL JAMB LOCKERS BY G.C., SEE SPEC.'S U) C c } ..NEW STRUCTURAL NEW VH. OPENING W/SIR, HEADER ABOVE—+,----r. , R I ' a F EX OR THEIR VE ILL NDOR TURNSTILE BY FED EX OPENING, INIF PER SECTION 2/A3.1%1L NSTRUCTURAL z I I 1 llJ I POSEW T PER SIR. DWG'S 2 O 19 A3.1 I I i i I I I I BUILT-IN SHELVES BY G.C., NEW CASED OPENING ICE MAKER I a I A SEE MILLWORK DETAIL C - 6 NEW ICE MAKER 32 017 NEW 518" GWB ON 6" METAL STUD 31 @ 16" O.C. BEARING PARTITION JAN. 016 GENERAL EXISTING OPENING STORAGE STEEL JAMB 009 EXI ( STING CMU WALL �� a P&D MANAGER ' 3 OPENING PLAN DETAIL 'A - 1s to 2 1/2" NEW EGRESS DOOR, C CHANGE SWING - — — —) WOMEN'S MEN'S HALL BUILD NEW 006 INFILL OLD DOOR A CLOSET — — — - ° 007 013 17 SORT MANAGER T.S. EX NEW OPS MGRS EXISTING VCT O11 /COORDS Lj FLOOR ARCHITECT TO o WORKSTQION Z VERIFY EXISTING Q e W 28 I WALL TYPE & RATING �, 1 2 25 O o O �1: H JH0 'U I- A P&D CHECK -IN A A Ts. p EX 002 - z 15 EXISTING CMU WALL i NEW VCT FLOOR I- 2 p�J_ VERIFY EXISTING �'I c w POST STRUCTURAL DWGS WINDOW MEETS FXG PERm SPECIFICATIONS, I z REPLACE IF NEEDED - %n A - o g� - OPS MGRS / z COMPIT— ROOM COMPUTER SERVER - EXISTING KITCHENETTE COORDS EQUIPMENTS D FEDEX 2 - z O12 OR THEIR VENDOR t MILLWORK OO8 , r Z _ EX EX ' r I I u o NEW VCT FLOOR 2 l_ i w KITCHENETTE ExIsnNGVCT FLOOR 7 .o NEW REFRIG. TRANSITION STRIP, TYP. wo i BY FXG A y NEW MASONARY OPENING + '. i. i_ R, EXISTING OPEN AREA I COPIER A3.1 INFILL PER SEC. 2(A3.1 ; .. i i 5O COLUMN KITCHENETTE A NEW DROP BEAM - O O05 T.S. ABOVE TRAINING / NEW � ; I •, - - 14 MEETING ROOM THRGHouT UPS EQUIPMENT BY 'EXISTING GWB. OO1 A —\/ NEW EGRESS CONTRACTOR, SEE SPEC'S NEW PILASTER/STRUCTURAL PARTITION EX O NEW VCT FLOOR 22 O ~ DOOR POST PER SIR. DWGS ..I ,. NOTE: NO CEIL ING • `- NEW STRUCTURAL I U ABOVE POST PER SIR. DWGS SENIOR A ENTRY MANAGER I 29 004 z I OPENING PLAN DETAIL "B" y EXISTING s-ta 24 ts'-u' FACP I MIN. - — SFt SF7 SF1 O SF7. NEW WINDOW TO I W DOOR .' , NEW WINDOW TO MATCH EXISTING i MATCH EXISTING I t. W z IIZZ C9 W U r7 N ZON =O W z In +' co _ z`r'a = Fw— =0 O � a � � 04 �' LLJ = = 0 N 7- LID 0 uj cy un Q N TITLE: PROPOSED OFFICE AREA FLOOR PLAN DATE ISSUED: 04 - 25 - 2022 REVISIONS: No. Description Date LEGEND �—� EXISTING PARTITION TO REMAIN PROPOSED NEW PARTITION 1Q CHECK -IN COUNTER SECTION (DRAWING NO.06211-0015) 2Q CHECK -IN COUNTER SECTION (DRAWING NO. 0621 T -0015) QCOUNTER SECTION (DRAWING. NO. 06211Z01) DRAWING NO.: QCOUNTER SECTION (DRAWING NO. 06211 -001) Al 2 ABUILT IN STORAGE SHELVES (DRAWING NO.06211-007)