HomeMy WebLinkAbout2 Witchwood Rd. Engineered Plan-TIFF FormatACCESS COVERS MUST BE WITHIN L6'OF FINISH GRADE 9'M1N COVER INSPECTION 36' MAX COVER PORT FIRST 2' TO BE LEVEL FILTER FABRIC % 'OVER UNIT U� 99. 75 9. 48 GAS BAFFLE 99.65 0 4 _ _ 99./5 3 OUTLET i-UNDERLAP FILTER FABRIC 2' EXISTING D-BOX 9 CULTEC CONTACTOR FIELD 1000 GAL, DRAIN C-4'S IN BED FORMATION. 3 x 3 SEPTIC TANK 13'r x 24'1 x 3'd 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE I 5 0 UP 65411 N E' B.V. CORNER OF-' CONCRETE PAD EL•103.01 WA TER GA rE® CLEAN SAND BACKF I L L AROUND AND 2' OVER CHAMBERS 0 0 �- R-500.00 ' S 89°57'33'W SIDE WALK LONG POND DRIVE INVERT ELEVATIONS INVERT OUT SEPTIC TANK: 99.75 INVERT IN DIST. BOX: 99.65 INVERT OUT DIST. BOX: 99.48 INVERT IN LEACH CHAMBER: 99.4 BOTTOM OF LEACH CHAMBER: 99. 15 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE s I : 94.3 DESIGN CR I TER I A : GENERAL NOTES: DESIGN FLOW: 3 BEDROOMS AT 110 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EOUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. SEPTIC TANK REOUIRED: 330 G.P.D. X 200% - 660 GAL. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1000 GAL. EXISTING MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL i SOIL ABSORPTION SYSTEM REOUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PERC RATE l 5 MIN/INCH SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. REOUIRED THAN 4' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS, PROVIDED: 9 CUL TEC CONTACTOR FIELD DRAIN C-4'S /N BED FORMATION. 72 LF a 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR I 6.7 SF/LF-482 SF x 0.74 GPD./SF-357 GPD APPROVED EOUAL. i SOIL TEST PIT DA TA ® 6. SEPTIC ANK AND REINFORCED PRECASTTCONCRETEDOROAPPROVEDSHALLBPOLYETHYLENE. INDICATES INDICATES BOTH SHALL BE WATERTIGHT, D-BOX SHALL BE WATER _V PERCOLATION OBSERVED TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE TEST GROUNDWATER OUTLET. TP #1 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. HORIZON TEXTURE COLOR 0 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. LOAMY IOYR 104. 3 Q FOR LOCATION OF UNDERGROUND UTILITIES, SAND 313 l0' _ ........ _ ... ... 103.5 8. EXISTING LEACH PIT TO BE PUMPED DRY AND B LOAMY I OYR BACKF I L L ED . SAND 518 28' _ ... ..... .. 102.0 i MED I UM / O YR,- 1, SAND 6/8 Al 40 120 , NO WATER 94.3 DATE: JANUARY 22. 2009 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: C 2 MIN/INCH SECOND FLOOR PLAN"ice�'-%- -=A '• 4:"'Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and t,ocal septic variances. Board of Health review and approval is required (Or any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. S P / T VT / C S S / L- /1 Mf Yarmouth Health Department C Y J T V APPROVED 2) � 2 W/ TCHWO O D ROAD "A P 5 8. RA R CEL Da YA R /ICJ U T,� , "A te �i� jj_-��Y ,� PREP,AREO FOR LEGEND 0 CB CONCRETE BOUND Q `% fa DD / v G.�1 Z_ � ,q � H E R -W_ WATER L /NE O HYDRANT nh EAPR3 20u� SC.A L E / - 2O " A R CH 6 2 O O 9-G OHW- GAS L!NE OVER HEAD WIRES H DEPT. _ ,� G (_ E U R U E Y I N G I N C -E- LIGHT POST 923. F2ou t g 6A UNDERGROUND ELECTRIC LINE i' r a r �' mo u t F� P o r t MA 02675 -T- -CTV- UNDERGROUND TELEPHONE LINE UNDERGROUND /I ��/ ,I � 508� 362-8 1 32 CABLEVISlON LINE ���� 508) 432-5333 +40.4 SPOT ELEVATION EXISTING CONTOUR 4{-0� PROPOSED CONTOUR JOB NO: 08 - 106 FIELD : CFW/EEK CAL C: SAH/CFW CHECK: CFW DRN: SAH