Loading...
HomeMy WebLinkAboutPlan AQ0.02 General Noteskn 8 o -� Q L E Q CV CV 0 CV 0 U 0 N m N N N O <9 a� LL s= O L O O N -­1 t= s= IL 6� 3 m X N N N N O Z O U mCID V 1 N Ln U Q 0 g Q U N Ln O N lLn GENERAL: CONCRETE: 1. REFER TO RAMAKER * ASSOCIATES POOL CONSTRUCTION DRAWINGS AND PROJECT SHOP DRAWINGS FOR PUMP, PIPING, 1. ALL CONCRETE SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI CONCRETE AND REINFORCING REQUIREMENTS. 3 18), THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE IN BUILDINGS (ACI 30 1) AND LOCAL BUILDING CODES. ALL CONCRETE WORK SHALL BE AS SPECIFIED AND RECOMMENDED BY ACI FIELD REFERENCE MANUAL 2. ALL DIMENSIONS OTHER THAN PURELY STRUCTURAL DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE 5P- 15. SPECIAL COLD WEATHER (ACI 30G) OR HOT WEATHER (ACI 305) CONCRETING PRACTICES 5HALL BE FIELD COORDINATED BY THE CONTRACTOR WITH RAMAKER * ASSOCIATES. ANY INCONSISTENCIES SHALL BE REPORTED TO UTILIZED WHENEVER APPROPRIATE. ALL 5HOTCRETE SHALL AL50 CONFORM TO THE REQUIREMENTS OF ACI RAMAKER * ASSOCIATES BEFORE PROCEEDING WITH THE WORK. 50GR-05 GUIDE TO 5HOTCRETE. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS IN THE FIELD. NOTIFY RAMAKER * ASSOCIATES 2. 5HOTCRETE SHALL HAVE A MAXIMUM 3/5" STONE AGGREGATE AND CAST IN PLACE CONCRETE SHALL HAVE A IMMEDIATELY, IN WRITING, OF ANY FIELD CONDITION UNCOVERED DURING CONSTRUCTION THAT 15 NOT CONSISTENT WITH MAXIMUM I " STONE AGGREGATE. EACH SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 THE PLANS. DAYS. PROVIDE 5% +1- 1 % AIR -ENTRAINMENT FOR ALL EXTERIOR CONCRETE. 4. THE CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWING SUBMITTALS OF 5UB CONTRACTORS AND SUPPLIERS 3. ALL REINFORCING BARS SHALL BE DEFORMED BARS CONFORMING TO REQUIREMENTS OF ASTM SPECIFICATION PRIOR TO SUBMITTAL TO RAMAKER � ASSOCIATES FOR REVIEW. SHOP DRAWINGS NOT BEARING THE CONTRACTOR'S AG 15, GRADE GO UNLESS OTHERWISE NOTED. APPROVAL STAMP WILL NOT BE REVIEWED AND WILL BE RETURNED NOT APPROVED. SHOP DRAWING SUBMITTAL IS REQUIRED FOR, BUT NOT LIMITED TO, REINFORCING STEEL LAYOUT AND STRUCTURAL STEEL FOR SLIDES AND POOL BASIN, POOL 4. REINFORCING SHALL BE SECURELY TIED IN ITS PROPER PLACE BEFORE AND DURING POURING OPERATION5 RECIRCULATION EQUIPMENT AND POOL DECK EQUIPMENT. USING APPROVED CHAIRS AND SPACERS AS REQUIRED. 5. UNLESS OTHERWISE NOTED, DETAILS SHOWN ON ANY DRAWING ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR 5. THE CONCRETE CONTRACTOR SHALL INSTALL OR GIVE OTHER TRADES AMPLE OPPORTUNITY TO INSTALL ALL CONDITIONS. ANCHORS, BOLTS, PLATES, NAILS, SLOTS, CHASES PIPE SLEEVES ETC., AS REQUIRED BY THESE TRADES. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE SETTING SCREEDS AND FORMS. G. UNLE55 OTHERWISE NOTED ALL FOOTINGS, PILES, CAISSONS AND PIERS SHALL BE CENTERED UNDER SUPPORTED MEMBERS. G. PROVIDE CLEARANCES FROM FACES OF CONCRETE TO REINFORCEMENT AS FOLLOWS UNLE55 OTHERWISE SPECIFIED: 7. WHEREVER SLEEVES ARE INSERTED IN CONCRETE SLABS, BEAMS OR WALLS, THEY SHALL CON515T OF PVC PIPE. SLABS ON FILL...... 3" BEAMS.. .... ..... 1 Y2" 8. THE ENGINEER WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES OF FOOTINGS.............3" PROCEDURES OR CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND PROGRAMS INCIDENT THERETO, AND THE ENGINEER WALL5..................2" EXTERIOR FACE, 2" INTERIOR FACE WILL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO PERFORM THE WORK IN ACCORDANCE WITH THE CONTRACT PIERS...................2" EXTERIOR FACE DOCUMENTS. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE INSTALLATION OF EMBEDDED ITEMS UNLESS 9. POOL CONFIGURATION SHALL MEET PUBLISHED STANDARDS OF MA55ACHU5ETT5 DEPARTMENT OF PUBLIC HEALTH APPROVED BY THE ENGINEER. COORDINATE INSTALLATION Of SLEEVES, PIPES AND CONDUIT WITH THE PLACING DEPARTMENT OF PUBLIC HEALTH AND THE NATIONAL SPA * POOL INSTITUTE. OF REINFORCING STEEL TO ENSURE THAT IT DOES NOT NEED TO BE CUT OR DISPLACED. 10. POOL CONTRACTOR SHALL PROVIDE OWNER WITH OPERATING MANUAL FOR FILTRATION EQUIPMENT. THESE MANUALS 7. ALL HORIZONTAL SURFACES INTENDED FOR FOOT TRAFFIC SHALL RECEIVE A NON -SLIP AND IMPERVIOUS SHALL BE OF A PERMANENT NATURE AND INCLUDE ALL DRAWINGS, ILLUSTRATIONS, OPERATING PROCEDURES, CHARTS, LIGHT -BROOM FINISH. STAMPED CONCRETE OR ANY OTHER SURFACES THAT RETAIN WATER ARE NOT ALLOWED. PARTS LIST, AND DATA LISTS. MANUALS SHALL BE EASILY READ AND UNDERSTOOD. THEY SHALL BE SECURELY ATTACHED TO FILTER SHELL. DATA LIST SHALL CONTAIN THE FOLLOWING INFORMATION: 8. CONCRETE SURFACES EXPOSED TO VIEW SHALL BE SOUND AND DENSE. PULL TIE RODS TO THE FULL LENGTH A. FILTER MANUFACTURER'S MODEL NUMBER OF CONES. WHERE PATCHING OF HONEYCOMBS AND VOIDS 15 REQUIRED, IT SHALL BE DONE AS SOON AS B. FILTER SERIAL NUMBER POSSIBLE AFTER THE REMOVAL OF THE FORMS. REPAIR AND PLUG TIE HOLES AND HONEYCOMBS WITH C. EFFECTIVE FILTER AREA IN SQUARE FEET NON -SHRINK CEMENT BASED PRODUCTS ACCORDING TO MANUFACTURER'S INSTRUCTIONS. D. DE51GN FLOW RATE IN GALLONS PER MINUTE E. MAXIMUM WORKING PRESSURE 9. ALL LAPS SHALL BE "B" SPLICES UNLESS NOTES OTHERWISE ON THE DRAWINGS OR UNLE55 SPECIAL CARE 5 F. MANUFACTURED DATE TAKEN FOR THE REINFORCING TO BE DETAILED AND PLACED TO PROVIDE STAGGERED LAPS. SPECIAL PLACEMENT AND SPLICING OF REINFORCEMENT USED IN 5HOTCRETE APPLICATIONS SHALL CONFORM TO THE REQUIREMENTS 1 1. WHERE AIR RELEASES ARE INSTALLED ON FILTER(5), THE FOLLOWING STATEMENT SHALL BE PLACED WITHIN THE AREA OF THE OF IBC-2000 SECTION 1913.4. AIR RELEASE 50 AS TO BE CLEARLY VISIBLE: "WARNING. DO NOT START UP THE SYSTEM AFTER MAINTENANCE WITHOUT FIRST OPENING THE AIR RELEASE AND PROPERLY ASSEMBLING THE FILTER AND SEPARATION TANK." 10. ALL CONCRETE SHALL BE CURED FOR A MINIMUM OF SEVEN DAYS. ANY UNFINISHED 5HOTCRETE WORK SHALL NOT BE ALLOWED TO STAND FOR MORE THAN 30 MINUTES UNLE55 EDGES ARE SLOPED TO A THIN EDGE, UNLESS 12. POOL CONTRACTOR TO PROVIDE OWNER WITH INSTRUCTIONS ON POOL DRAINAGE AND WINTERIZING IF REQUIRED. DETAILED OTHERWISE. PRIOR TO PLACING ADDITIONAL MATERIAL ADJACENT TO PREVIOUSLY APPLIED WORK, ALL INSTRUCTIONS SHALL INCLUDE DRAWINGS SHOWING PIPE AND VALVE LOCATIONS AS TAGGED BY THE POOL CONTRACTOR, EDGES SHALL BE CLEANED AND WETTED. ALL VALVES SHALL BE TAGGED WITH PIPE FLOW DIRECTIONS INDICATED. 1 1. ALL CONCRETE REINFORCING WITHIN THE POOL AREA TO BE BONDED AND GROUNDED ELECTRICALLY IN 13. ALL METAL COMPONENTS ASSOCIATED WITH THE POOL AREA (INCLUDING PUMPS) SHALL BE ELECTRICALLY BONDED AND ACCORDANCE WITH NATIONAL, STATE, AND LOCAL CODES, BY THE ELECTRICAL CONTRACTOR. GROUNDED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL CODES. 12. CALCIUM CHLORIDE AND OR ADMIXTURES CONTAINING CHLORIDE SHALL NOT BE USED. 14. ALL POOL HEATERS TO BE INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODES. 13. REFER TO THE FOLLOWING TABLE FOR REINFORCING BAR DEVELOPMENT AND SPLICE LENGTHS: 15. 5UB-50IL UNDER POOL SHALL HAVE A MINIMUM BEARING STRENGTH OF 3000 P5F. GENERAL CONTRACTOR SHALL \`■�JL��1����1���Ll�el\L�� I G. PLANS ARE FOR POOLS ONLY. BUILDING, VENTILATION, ELECTRICAL, PLUMBING AND GAS PIPING ARE NOT PART OF THI5 PLAN. 17. POOL DESIGNER ASSUMES NO RESPONSIBILITY FOR STRUCTURES AND EQUIPMENT MANUFACTURED BY OTHERS. DESIGNER SHALL NOT TAKE RESPONSIBILITY FOR OPERATION AND MANAGEMENT OF POOL FACILITIES. 18. THE POOL CONTRACTOR 15 RESPONSIBLE FOR PROVIDING A COMPLETE INSTALLATION OF THE THE SYSTEMS INCLUDED IN THESE DOCUMENTS. UNLESS NOTED OTHERWISE, THE CONTRACTOR SHALL PROVIDE ALL COMPONENTS NECESSARY FOR A COMPLETE INSTALLATION, 19. ALL EXPOSED PIPING AND VALVES TO BE CLEARLY LABELED TO INDICATE FUNCTION AND FLOW DIRECTION. 20. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, DETAILS, AND COSTS FOR A COMPLETE INSTALLATION RESULTING FROM SUBSTITUTION OF COMPONENTS. 2 1. IF APPLICABLE, OPTIONS ARE FOR THE CONTRACTOR'S CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES RESULTING FROM CHOOSING AN OPTION AND SHALL COORDINATE ALL DETAILS. THE C05T OF ADDITIONAL DE51GN SERVICES OR MATERIAL C05T NECE551TATED BY SELECTION OF AN OPTION SHALL BE BORNE BY THE CONTRACTOR. 22. POOL CONTRACTOR SHALL PRESSURE TEST ALL PIPING PRIOR TO BACKPILLING AND IMMEDIATELY PRIOR TO POURING OF THE DECK. 23. WATER SERVICE 15 PROVIDED BY THE TOWN OF WEST YARMOUTH. 24. THE POOL OWNER SHALL PROVIDE THE FOLLOWING ITEMS IN THE IMMEDIATE VICINITY OF THE POOL: A. EMERGENCY TELEPHONE AND EMERGENCY CONTACT LIST. B. DRINKING FOUNTAIN C H05E BIB WITH VACUUM BREAK 25. THE POOL OWNER SHALL ENSURE THE RE5TROOM AND DRESSING FACILITIES, INCLUDING THE TOILETS, SHOWERS, LOCKERS, AND FURNITURE ARE IN GOOD CONDITION AND SANITARY. THE OWNER SHALL AL50 ENSURE SOAP IN PERMANENTLY INSTALLED DISPENSERS 15 CONTINUALLY AVAILABLE AT EACH SINK AND SHOWER, INDIVIDUAL TOWELS IN DISPENSERS OR HOT AIR DRYERS AT EACH SINK, AND TOILET TISSUE IN PERMANENTLY INSTALLED D15PEN51NG DEVICES. 2G. FOR EACH 2O00 SQUARE FEET OF WATER SURFACE AREA OR FRACTION THEREOF, THE POOL OWNER SHALL PROVIDE AND INSTALL THE FOLLOWING ITEMS IN THE IMMEDIATE VICINITY OF THE POOL. A. RING BUOY AND 4' POLYETHELENE ROPE, 1-1 /2 TIMES THE WIDTH OF THE POOL, U.S. COAST GUARD APPROVED B. RESCUE TUBE I. SPINE BOARD (ONLY AT POOLS REQUIRING LIFEGUARDS) J. RESCUE HOOK K. 24 UNIT STANDARD FIRST AID KIT INCLUDING TWO BLANKETS L. SPINE BOARD (ONLY AT POOLS REQUIRING LIFEGUARDS) M. ANY OTHER SAFETY EQUIPMENT REQUIRED BY STATE AND LOCAL CODES 27. THE POOLS HAVE BEEN DESIGNED TO WITHSTAND ALL ANTICIPATED HYDRAULIC STRUCTURAL LOADING FOR BOTH FULL AND EMPTY CONDITIONS. 28. THE POOLS SHALL BE CONSTRUCTED OF MATERIALS THAT PROVIDE A RIGID WATERTIGHT SHELL WITH A SMOOTH IMPERVIOUS FINISH THAT 15 NON -TOXIC AND EASILY CLEANED. THE FLOOR IN THE SHALLOW AREA (5 FEET OR LESS) SHALL HAVE A SLIP RESISTANT FINISH. 29. ALL POOL INTERIORS SHALL BE LIGHT IN COLOR HAVING A VALUE OF G.5 OR GREATER ON THE MUNSELL COLOR ORDER SYSTEM IF NOT OTHERWISE SPECIFIED BY LOCAL CODE. ALL COLORS, PATTERN OR DEMARCATION LINES MAY NOT NEGATIVELY IMPACT THE OBSERVER'S VISUALIZATION OF BATHERS. ALL DEMARCATION LINES SHALL BE OF CONTRASTING COLOR TO THE POOL INTERIOR. 30. POOL FACILITY MUST COMPLY WITH THE NATIONAL ELECTRIC CODE. 3 1. POOL CONTRACTOR TO PROVIDE ENGINEER WITH RECORD DRAWINGS SHOWING A5-BUILT LOCATION OF PIPING. 32. THESE PLANS HAVE BEEN DEVELOPED WITH THE INTENT TO MEET THE 2010 ADA STANDARDS FOR ACCE55113LE DESIGN. THE ENGINEER OF RECORD SIGNING THESE DRAWINGS 15 RESPONSIBLE FOR DESIGNING THE POOLS TO BE ADA ACCESSIBLE FROM THE POOL DECK. THE OWNER/ARCHITECT SHALL BE RESPONSIBLE FOR ENSURING THE REMAINING ELEMENTS OF THE PROJECT MEET THE 2010 ADA STANDARDS FOR ACCE551BLE DESIGN (OR LOCAL JURISDICTION ADAPTATIONS, IF APPLICABLE), SUCH AS ACCESS ROUTES, DRINKING FOUNTAINS, RE5TROOM FACILITIES, BUILDING TRAVEL, DOOR ACCESS, SIGNAGE, ETC. IF ISSUES RELATED TO ADA ACCESS ARE DISCOVERED, PLEASE NOTIFY THE ENGINEER OF RECORD IMMEDIATELY. Reinforcing Bar Development and Splice Lengths for Vc = 4000 psi and fy= 60 ksi Tension Develo ment Class "B" Splice Std. 90 de . Hook Compression Bars Bar Size To Bar Other Bar Top Bar Other Bar Embed. Leg Length Develop. �Ldc Splice Ldt Ldo Lbt Lbo Ldh ry Lh w in. in. in. min. in. min.(in.)^� in. #3 12 12 16 16 6 6 8 12 #4 15 12 19 ' 1_6 7 8_ 15 #5� � 18 � 14 � �.� . � 18 .. 8 � 10 � _9 _ �- 12 .14_,._. _ 19 . #6 22 17 _24 29 ' 22 10 12�..._ 23.._...__. 12 17 26 #8 _.__.,.._ 37 28 . __._._._. _ _ 48 37 ._. __.__._.__. ._ 13 16 19 30 #9 �46 35 60 46 15 19_ � 21_ 34 _ �_. #10 57 _..44._._r__ _____74 ' S7 17 22 � � 24 38 _ #11 68 � 52 88 �� 68 19 24 � _. -_.e... _ 27 �..a®® 42 _ #14 93 72 - .._u_ ._ . _v. --- --- a_. ��._. 32 31 _.______..___.__...__..__ 32 __._._ ---W #18 ...__._.._.___, 151 116 W_.._ --- --- __._..__.._._____._.__._ 43 41 43- - NOTES: 1. STRAIGHT DEVELOPMENT AND CLA55 "B" SPLICE LENGTHS SHOWN IN ABOVE TABLE ARE BASED ON UNCOATED BARS ASSUMING CENTER -TO -CENTER BAR SPACING = 12" WITHOUT TIES OR STIRRUPS AND BAR CLEAR COVER = 2". NORMAL WEIGHT CONCRETE WITH NO TRANSVERSE REINFORCING ARE BOTH ASSUMED. NO EXCESS REINFORCING 15 ASSUMED. 2. STANDARD 90 DEGREE HOOK EMBEDMENT LENGTHS ARE BASED ON BAR 51DE COVER = 2.5" AND BAR END COVER = 2" WITHOUT TIES AROUND HOOK. 3. TABLE DOES NOT REFLECT SPECIAL SEISMIC CONSIDERATIONS FROM ACI 3 18-05, CHAPTER 2 1. LIFEGUARD G: THE DEVELOPMENT AND IMPLEMENTATION OF A LIFEGUARD STAFFING PLAN 15 THE RESPONSIBILITY OF THE OWNER. IT IS RECOMMENDED THAT THE OWNER REVIEW THE LIFEGUARD STAFFING REQUIREMENTS WITH A CONSULTANT SPECIALIZING IN POOL SAFETY OR THE AMERICAN RED CROSS. OWNER 15 RESPONSIBLE FOR OBTAINING APPROVAL OF THE LIFEGUARD STAFFING PLAN FROM THE STATE OF MASSACHUSETTS DEPARTMENT OF PUBLIC HEALTH AND/OR COMMERCE. 51GNAGE REQUIRED FOR POOLS: THE POOL OWNER 15 TO PROVIDE POOL AND/OR SPA SIGNAGE MEETING THE REQUIREMENTS OF THE STATE OF MASSACHUSETTS DEPARTMENT OF PUBLIC HEALTH AND THE REQUIREMENTS OF THE FEATURES MANUFACTURER. THE OPERATOR SHALL ENSURE THE POOL USE RULES GOVERNING SAFETY AND SANITATION ARE POSTED AND ENFORCE THESE RULES: THE POOU5PA RULES AND REGULATION 51GNAGE SHOULD BE EA51LY READABLE AND POSTED IN A CONSPICUOUS PLACE IN THE POOU5PA AREAS AND RE5TROOM5. LETTERING MUST BE CLEAR, LEGIBLE, AND AT LEAST ONE INCH HIGH UNLESS OTHERWISE NOTED. 1) NO PERSON HAVING A COMMUNICABLE DISEASE SHALL BE EMPLOYED OR WORK AT A SWIMMING, WADING, OR SPECIAL PURPOSE POOL 2) THE FOLLOWING REGULATION SHALL BE ENFORCED BY THE OPERATOR: A. NO BATHER SHALL ENTER THE POOL UNLESS A CLEANSING SHOWER 15 TAKEN FIRST. B. NO BATHER SHALL WEAR A BATHING SUIT THAT 15 UNCLEAN C. NO PERSON SUFFERING FROM A FEVER, COUGH, COLD, INFLAMMATION OF THE EYES, NASAL OR EAR DISCHARGES, OR ANY COMMUNICABLE DISEASE SHALL BE ALLOWED THE USE OF THE POOL. D. NO PERSON WITH SORES OR OTHER EVIDENCE OF SKIN DISEASE, OR WHO 15 WEARING A BANDAGE OR MEDICAL COVERING OF ANY KIND, SHALL BE ALLOWED THE USE OF THE POOL. E. NO PERSON SHALL SPIT IN OR IN ANY OTHER WAY CONTAMINATE THE POOL, OR ITS FLOORS, WALKWAYS, AISLES, OR DRESSING ROOMS. F. NO GLASS, WITH THE EXCEPTION OF SHATTERPROOF LIGHT SHIELDS, SHALL BE PERMITTED IN THE POOL OR ON THE WALKWAYS WITHIN EIGHT FEET OF THE POOL. G. NO PERSON SHALL BRING OR THROW INTO THE POOL ANY OBJECT THAT MAY IN ANY WAY CARRY CONTAMINATION OR ENDANGER THE SAFETY OF BATHERS. 3) THE OPERATOR SHALL CAUSE A SIGN TO BE PLACED AT THE ENTRANCE OF THE POOL ENCLOSURE, OR ON THE WALL OF THE DRESSING ROOM WHERE ONE 15 PROVIDED, WHICH READS SUBSTANTIALLY AS FOLLOWS: A. ALL PERSONS ARE REQUIRED TO TAKE A CLEANSING SHOWER BEFORE ENTERING THE POOL. B. NO PERSON WITH A COMMUNICABLE DISEASE 15 ALLOWED TO USE THE POOL. 4) THE OPERATOR OF SPECIAL PURPOSE POOLS SHALL INCLUDE ON THE SIGN THE FOLLOWING WARNINGS: A. DO NOT USE WHEN ALONE. B. DO NOT USE WHILE UNDER THE INFLUENCE OF ALCOHOL, ANTICOAGULANTS, ANTIHISTAMINES, VASOCONSTRICTORS, STIMULANTS, HYPNOTIC5, NARCOTICS, OR TRANQUILIZERS. C. ELDERLY PERSONS, PREGNANT WOMEN, AND PERSONS SUFFERING FROM HEART DISEASE, DIABETES, HIGH OR LOW BLOOD PRESSURE SHOULD NOT USE THI5 POOL UNTIL THEY CONSULT WITH THEIR PHYSICIAN. D. DO NOT USE THE POOL WHEN THE WATER TEMPERATURE 15 GREATER THAN 104°F. E. OBSERVE A REASONABLE TIME LIMIT (E.G. TEN MINUTES), THEN SHOWER, COOL DOWN AND IF YOU WHI5H RETURN FOR ANOTHER BRIEF STAY. LONG EXPOSURES MAY RESULT IN NAUSEA, DIZZINE55 OR FAINTING. F. THE USE OF OILS AND BODY LOTION BY BATHERS 15 PROHIBITED. 5) THE OPERATOR OF SPECIAL PURPOSE POOLS SHALL PROVIDE A PERMANENTLY MOUNTED CLOCK, WITH A LARGE DIAL, LOCATED AS TO BE EASILY READABLE BY BATHERS AT THE POOL. IN ADDITION TO THE ABOVE RULES: 1. POOLS WITH 200 SQUARE FEET IN AREA OR GREATER THAT DO NOT HAVE AN APPROVED DIVING WELL CONFIGURATION SHALL HAVE "NO DIVING" SIGNS IN AT LEAST 4 INCH HIGH LETTERS. 2. WAVE POOLS SHALL HAVE 51GNAGE AS REQUIRED BY THE WAVE EQUIPMENT MANUFACTURER. P05T 51GNAGE IN THE AREA OF THE WAVE POOL AS REQUIRED. 3. FLOWRIDER POOLS SHALL HAVE SIGNAGE AS REQUIRED BY THE EQUIPMENT MANUFACTURER. P05T 51GNAGE IN THE ARE OF THE FLOWRIDER POOL AS REQUIRED. SIGNAGE NOTE: IT 15 RECOMMENDED THAT THE OWNER REVIEW SIGN REQUIREMENTS WITH A CONSULTANT SPECIALIZING IN POOL SAFETY OR THE AMERICAN RED CROSS, THE OWNER 15 RESPONSIBLE FOR OBTAINING APPROVAL FROM THE STATE OF MASSACHUSETTS DEPARTMENT OF PUBLIC HEALTH AND/ OR COMMERCE FOR ALL 51GNAGE. CONFIDENTIALITY: THIS DOCUMENT CONTAINS CONFIDENTIAL OR PROPRIETARY INFORMATION OF RAMAKER t. ASSOCIATES, INC. NEITHER THI5 DOCUMENT NOR THE INFORMATION HEREIN 15 TO BE REPRODUCED, DISTRIBUTED, USED OR DISCLOSED EITHER IN WHOLE OR PART EXCEPT AS SPECIFICALLY AUTHORIZED BY RAMAKER t ASSOCIATES, INC. j 4 i"k M A'Km'0'*0 " E R eiliployee-owned Certrficataon * Seal: I hereby certify that this plan, specification, or report was prepared by me or under my direct 5uperw5ion and that I am a duly Licensed Profe55ional Engineer under the laws of the 5tate of Massachusetts. MARK I DATE I DESCRIPTION DATE 01 /25/2022 ISSUED: 155UE STATE SUBMITTAL PHASE: PROJECT TITLE: CAPE COD N F LATAB LE PARK PROJECT OWNER: CAPE COD INFLATABLE PARK PROJECT LOCATION: WEST YARM O UTH , MA55ACH U5ETT5 SHEET TITLE: GENERAL NOTE5 SCALE: NONE NUMBER 52987 NUM EB ACQ O.O 2 J