Loading...
HomeMy WebLinkAboutEngineer PlanTOP FNDN. AT EL. 14.0' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 1,Al/J1►II I►I 7�' nC /"nvro nvro nnrn.e�r . EXISTING 1000 GALLON SEPTIC TANK (H- 10 ) 'RE -USE - SEE N DEPTH OF FLOW = 4' TEE SIZES: INLET DEPTH = 10" ar OUTLET DEPTH = 14 FOUNDATION - EXIST. SEPTIC TANK - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM THE INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE OF 1000 GALLONS, AND DETERMINE SUITABILITY FOR RE -USE. REPLACE WITH 1500 GAL. TANK IF NOT SUITABLE FOR RE -USE & ADD REQUIRED TEES AND GAS BAFFLE BUOYANCY CALC FOR H-10 1000 GAL. PUMP CHAMBER (SHOREY EXAMPLE): WGT: 8,240 LBS 8.5 x 4.8 x 1.97 x 62.4 = 5015 LBS UP (OKAY) RUN PIPE LEVEL 2� FOR FIRST 2' U rl / 11.50't* TEE GAS 12.53' E BAFFLE o 12.70' �� o� 6" CRUSHED STONE OR MECHANICAL oc COMPACTION. (15.221 [2]) ( 2 % SLOPE) IBENCH MARK - HYDRANT ON TAG I BOLT #1028 ELEV. = 15.0 LARGE OAKS 12' W.PINE PROVIDE VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT WITH HOMEOWNER CONSULTATION) 05-199 FORSYTHIA 11' PUMP 17' CHAMBER ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 11.28' SEPARATE CIRCUIT FROM PUMP LILAC FIN Iva I Im= r5 O ti EXIST. p p ST 13,0 �� 12.5 PROP. ho PC Ftic� 1p 12.3 EXISTING LEACHING AREA IS IN AREA OF PROPOSED SAS ALARM ON FLOAT SWITCH SETTINGS: PUMP ON 4" WORKING RANGE PUMP OFF 2" DOUBLE WASHED PEASTONE 12.53' , 0.58, PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE 3/4" TO 1 1/2" DOUBLE WASHED STONE D' BOX 2' 1000 GAL. H-10 S 700 GAL.+ RESERVE 8' 4' 8' WATERPROOF PUMP CHAMBER (NOT TO SCALE) 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. PROVIDE APPROX. 111' OF 40 MIL LINER AT LIMIT OF REMOVAL, AROUND ENTIRE PERIMETER OF SAS (EXCEPT IN AREA OF EXISTING SEPTIC TANK). TOP AT ELEV. 13.0', BOTTOM AT ELEV. 9.0, 12. IN LOT 277 12.6 'f`11.7 �� 5,506t S.F. O 13 -gam t,11.7 + \ 2.7 / S 0 \ 11.8 EXIST. DWELL A- 1 12 + 1 211.8 TOP FNDN 14.0' 3 �j P / 3.2 1 0 QGo �G 1 .2 / F C. " 1 2.4 BLOCONCK 13.0 p� PATIO 12.9 LEACHING FACILITY 12.9 5' EL 13' TEST HOLE LOGS ENGINEER: LISA LYONS, RS WITNESS: AMY VON HONE, RS DATE: 8/25/05 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 11.95' w � 0" Z J 6" 0 4' 10" EL. 9.0' 28" USE ADJ. WATER AT EL. 7.95' 2" PRESSURE LINE SLOPE TO DRAIN BACK TO PC WEEP HOLE CHECK VALVE MYERS SRM 4 SUBMERSIBLE 4/10 HP PUMP S`� STEM (OR EQUAL) PERIMETER DIMENSIONS OF . FIELD 1"20' PERC E ml IN FI LL A LS 1OYR 4/2 B LS 1OYR 5/6 C MS obs water 2.5Y 6/4 ELEV. 12.7' 10.37' i.95' 4.7' 0 z 0 cYc�E% e°Po U LOCUS RO �FSJ LOCATION MAP NTS ASSESSORS MAP 48 PARCEL 77 GROUNDWATER ADJUSTMENT DATA: WELL: MIW 29 ZONE: A ADJ: 1.8' YARMOUTH HEALTH DEPT. ALLOWS 1' OFF THE GROUNDWATER ADJUSTMENT (1' TAKEN) VARIANCES REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405: li: REDUCTION IN SETBACK TO PROPERTY LINE, SAS & SEPTIC TANK (PC) TO LOT LINE (10' TO 5') lb: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10') 19: REDUCTION IN SETBACK TO LEACHING C. BASIN (25' TO 17') 1 is REDUCTION IN GROUNDWATER ELEVATION, 5' TO 4' NOTES: 1. DATUM IS ASSUMED SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED ) DESIGN FLOW: 3 BEDROOMS (1 10 GPD) = 330 GPD 2. MUNICIPAL WATER IS EXISTING USE A 330 GPD DESIGN FLOW :, PIPE ?I -CH T�! RP 1 /R" PER :=:�OT- 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AAS4"Fi-'1O SEPTIC TANK: 330 GPD ( 2 ) = 660 5. PIPE JOINTS TO BE MADE WATERTIGHT. RE -USE EXISTING 1000 GAL. SEPTIC TANK (SEE NOTE) 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. LEACHING: 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT BOTTOM AREA: 407 SF x 0.74 = 301 GPD TO BE USED FOR ANY OTHER PURPOSE. PERIMETER: 96' x 0.74 x 0.58' = 41 GPD 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 462 342 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT TOTAL: S.F. GPD INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED USE (5) STANDARD INFILTRATORS IN FROM BOARD OF HEALTH. CONFIGURATION SHOWN, WITH 4' STONE AT 10. PUMP & REMOVE EXIST. LEACHING AREA SIDES AND 2.3' AT ONE END AND 1.0' AT 11. ELECTRICAL PERMIT REQUIRED OTHER END 12. INSTALLER TO DETERMINE ADEQUACY OF ELECTRICAL SYSTEM i FOR PUMP INSTALLATION. LEGEND i TITLE 5 SITE PLAN 100.0 PROPOSED SPOT ELEVATION OF 1 CYGNET ROAD 100x0 EXISTING SPOT ELEVATION IN THE TOWN OF: 100 PROPOSED CONTOUR (WEST) YAR M 0 UTH 100 EXISTING CON OUR„ -„ PREPARED FOR: JAYE KESTEN '.° ••.-11°_. C'... s. ,`i ^i f!C' ST ATT.n (+rn.e.IIi-. .. I 1 20 0 20 40 60 BOARD P. F HEALTH . ,. I � _ _ CALE: 1 20 DATE: OCTOBER 25 2005 APPROVED DATE _ a> „1,G„C,��,,�a� off8-362 454E fax 508 36.2-9880a V IE Lei' down cape engineering, inc, ASs LZHOF/,fqs ,Hof /� sq JAN 1 9 2007 ARNE H. `' ARNE cy� HEALTH DEPT. CIVIL ENGINEERS o OJALA H. LAND SURVEYORS CIV ALA C No 3 92 939 rain st, yarmouth, ma 02675 ;,? ry