HomeMy WebLinkAboutEngineer PlanLEGEND
A„
--102-- EXISTING CONTOUR
02 EXISTING CONTOUR
x 100.98 EXISTING SPOT GRADE
-W- EXISTING WATER SERVICE
---G EXISTING GAS SERVICE
H44/.-- OVERHEAD WIRES
TEST PIT
c$
BENCHMARK
in yA
CL
3 • �
� 5
s Cmi lsm u.ncU Qc,:wmm aaaa
99.58 LOCUS MAP
N ~
> N W 99.69CO VALHALLA DRIVE
V o PK SET
100.00
w >- \
100.32 102.69
= 99,4 \ 100.92 101,67
.66 p,14.61,
EME \ + 98.30 A=118.99'32 R,145.0
.� 99.91 190 pp'
+ .41 -XI
1I x 98.6 101981 C9 / x 104.98
/ 102,43
EXlS77NG LEACH PIT / 102'40
(per record location) + 97.43 9750 10-1.95 PAVED
TO BE PUMPED, FILLED WITH 98.93
SAND & ABANDONED O / 102.38 DRIVEWAY 1 rx,
063
+ 98.1� 98.01 y / � 10294 1 1 \
98.01 I \ \
97.96r -'�` / x 103,17 \
103.45
EXISTING SEPTIC TANK i f 9 7 x 103, 9 l
TOP OF TANK, EL=96.47t i 103,20 -20'
INV.. (OUT)= 95,12t(VERIFY) x98.14
!.=96.47
ENCHMARK TP-1 103. 6 GARAGE
98.08 .52 +
P OF TANK 99. PORC Z
x 98.32
3 '33' TP-2 O (x 106.30
O zEXISTING
HOUSE#102) (I \ I wo F EL=5.0L'
.98.1 FT ooCELLAR FL EL.=9$.Sf NX3
!�Do., 1 S. WALKOUT ii S" MEN - \ \ , Z
\ � 9.75 O + 96.65 102.30
.`� SCREENED x \ \
VENT PORCH N
+ 98.75 > \
x 102.30 � A� I � \
T PROPO�ED S.A.S. -X
2-500 GALLON CHAMBERS
SURROUNDED WITH STONE -
x 100.90 � LOT 10
loo.a0 x _ - -
� - 25,360tS.F. 10
I �1-oe- -" f•ep� '- - �
75.00,
S 92756" E \ x 9Y,80 - x 9 0
115.12'
N 8950'29" E
I Yarmouth Ith De artment I NOTE: HOUSE LOCATION IS TAKEN FROM CERTIFIED PLOT PLAN BY DOWN
of J/e" A D �v p CAPE ENGINEERING INC., YARMOUTH PORT , MA, DATED 6/4/1992
PETER T. �1
McENTEE
CIVIL
uo. 35109
Date
9� 1 Z4- OWNER OF RECORD
GULLOTTI, FRANK P JR
GULLOTTI, SHIRLEY A
102 VALHALLA DRIVE
SOUTH YARMOUTH, MA 02664
PARCEL ID: 118-60
102 VALHALLA DRIVE, SOUTH YARMOUTH, MA
Prepared for: Carol Vela, 75 Pound Road, Cumberland, RI 02864
Engineering by:
Engineering Works, Inc.
12 West Crossfield Road, Forestdole, MA 02644
(508) 477-5313
SCALE
1"=20'
DRAWN
P.T.M.
JOB. NO.
276-23
DATE
12/20/23
CHECKED
P.T.M.
SHEET NO.
1 Of 2
SEPTIC TANK
INSTALL RISERS & COVERS OVER
INLET &
OUTLET AND SET TO 6' OF FINISH
GRADE PROPOSED
D-BOX
INSTALL
RISER &
COVER
SET TO
6" OF GRADE
T.O.F=100.6t
-F.G. EL.=99.0t F.G. EL.=98.4f
F.G.
EL.=98.6t
L = 13'
L = 16'
® S=1% (MIN.)
a S=1% (MIN.)
4"SCH40 PVC
4"SCH40 PVC
EXISTING 48" LIQUID
LEVEL
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE
ON A MECHANICALLY COMPACTED STABLE BASE OR
SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310
CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
2' EFF.
DEPTH
INV.=94.87JPROPOSE`INV.=94.70
INV.=95.12 3 OUTLETS
H-20 RATED INV.=94.50-
TOP CONIC. ELEV.= 95.6t
BREAKOUT ELEV.= 95.00
INV. ELEV.= 94.50
BOTTOM ELEV.= 92.50-
4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
4' ABOVE GROUNDWATER
NO GROUNDWATER, EL.=87.0 -
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL.=95.0
FOR A DISTANCE OF 15' FROM THE EDGE
OF THE PROPOSED S.A.S.
PROPOSED S.A.S.
INSTALL RISER & COVER OVER ONE CHAMBER AND
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
F.G. EL.=99.5± I,VENT
MAINTAIN 2% SLOPE I I OVER S.A.S.
3'
SEPTIC SYSTEM PROFILE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
-310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL
1) A 3' variance to the 3' maximum cover requirement, for up to
6' of max. cover. S.A.S. shall be H-20 and vented.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND. THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL.
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY.
DESIGN CRITERIA
NUMBER OF BEDROOMS: 3
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <5 MIN/IN
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
EXISTING SEPTIC TANK: 1000 GALLON CAPACITY
PROPOSED D-BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES WITH
STONE AROUND AND BETWEEN CHAMBERS (10.8' x 28.01
SIDEWALL AREA: 2(10.8' + 28.0') x 2 = 155.2 SF
BOTTOM AREA: 10.8' x 28.0' = 302.4 SF
TOTAL AREA: ............................. .............................. 457.6 SF
PROPOSED S.A.S.
2-500 GALLON CHAMBERS
SURROUNDED WITH STONE
-2" LAYER OF 1/8" TO 1/2'
DOUBLE WASHED STONE
OR APPROVED FILTER FABRIC)
���I:IIi[el�l•`"11�ISE-'I�Ld>Q�P
foRCF/
SCREENED
PORCH
S.A.S. LAYOUT
SOIL LOG
DATE: DECEMBER 13, 2023
IjMNEgt,LUATOR: ANNA WIMMER, SE-14,615
BARRY LEWIS - HEALTH AGENT
ELEV. TP - 1 DEPTH ELEY. TP - 2 DEPTH
99.0 A 0" 99.0 A 0"
MED. SAND MED. SAND
98.3 1OYR 4/1 98.3 1OYR 4/1
8" 8"
E E
MED. SAND MED. SAND
1OYR 5/3 10YR 5/3
97.5 B 18" 97.5 B 18"
LOAMY SAND LOAMY SAND
2.5Y 5/8 2.5Y 5/8
PERC
BOTT. 34"
96.5 C 44" 96.5 C 44"
MED. SAND MED. SAND
2.5Y 6/4 2.5Y 6/4
87.0 144" 87.0 144"
PERC RATE 4 MIN/IN. "B" HORIZON
NO GROUNDWATER ENCOUNTERED
TO 1-1/2" DOUBLE
WASHED STONE
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
102 VALHALLA DRIVE. SOUTH YARMOUTH. MA
Prepared for: Carol Vela, 75 Pound Road, Cumberland, RI 02864
Engineering by: SCALE DRAWN JOB. N0.
En ineerin Works Inc N.T.S. P•T•M• 276-23
W 9
I DESIGN FLOW PROVIDED: 0.74 GPD/SF(457.6 SF) = 338.6 GPD 12 West Crossfield Road, Forestdole, MA 0264-4 DATE CHECKED SHEET N0. I
1(508) 477-5313 12/20/23 P.T.M. 2 of 2