HomeMy WebLinkAbout148 Berry Avenue rental inspectionTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Debra Bruinooge
Inspection Date: Apr 1, 2024
Record: Rental Registration #BHR-24-392
Location: 148 BERRY AVE, WEST YARMOUTH, MA 02673
Applicant: ROBERT & JAYME GANGI
Rental Inspection
Overall Result: Pass
Overall Remarks:
Met with owner's agent Liz for the inspection. Home is currently unoccupied.
Overall home was found neat, clean and organized. Sent email to owners
summarizing inspection report for their review as smoke and co detectors
were not all in place and there is a leak in one of the upstairs bedrooms. Those
items need to be addressed before rental certificate can be issued.*Update
05/09: Owners sent photos showing replaced smoke/co and ceiling leak
patched. Rental certificate an be issued.
Checklist:
1.
Number of Bedrooms
Result: Pass
Remarks:
#1 13.425 X 13.255 (Downstairs) #2 11.055 X 24.00 (Upstairs) #3 13.300 X
23.990 (Upstairs)
2.
Maximum Occupancy: Based on septic system capacity, number of bedrooms
and bedroom square footage
Result: Pass
Remarks:
Based on 330 GPD and 3 bedrooms square footage, maximum occupancy is 6.
3.
Basement
Result: Pass
Remarks:
Partially finished. Not to be used as a sleeping area.
4.
Electrical Panel
Result: Pass
Remarks:
Well labeled
5.
Copy of Tenant's Legal Rights have been issued to tenant.
Result: Pass
Remarks:
left on the counter for owners to put in welcome book and gave a copy to the
rental agent.
105CMR 410.00 0Minimum Standards of Fitness for Human
Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks, Toilets, Tubs & Showers
*
Result: Fail
Remarks:
-Drain plug missing from tub -Scraping and recaulking needed in and around
tub
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs a & showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room & every room containing a
toilet, shower or bathtub from September 15th through May 31st. 64° from 11:01
pm to 6:59 am 68° from 7 am to 11:00 pm
Result: Pass
410.200 Provision and Metering of Electrical or Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Skip
410.220 Natural and Mechanical Ventilation
*
Result: Pass
410.230 Owner's Laundering Responsibilities
If owner provides bed linens, towels, pillows or mattress
Result: Pass
410.235 Owner's Installation, Maintenance and Repair
Responsibilities
*
Result: Pass
410.240 Occupant's Installation and Maintenance
Responsibilities
*
Result: Skip
Remarks:
Currently unoccupied.
410.250 Asbestos-containing Material
*
Result: Pass
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply & Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting Systems & Exit Signs
For properties with 10 or more units
Result: Skip
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon Monoxide Alarms
*
Result: Pass
410.400 Owner/Manager Contact Information and Notice of
Occupants' Legal Rights and Responsibilities
Contact information and postings inside and outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
410.420
Habitability Requirements
Result: Pass
410.430 Natural Light and Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in Residence
*
Result: Pass
410.500 Owner Responsibility to Maintain Building &
Structural Elements
*
Result: Fail
Remarks:
-Rot in windowsills 2nd and 3rd window on second floor-*update: owners have
started to address -Peeling paint on front right of house-*update: owner plans
on working on this -Standing water in the back yard from sump pump
410.510 Occupant 's Responsibility Regarding Building and
Structural Elements
*
Result: Skip
Remarks:
Unoccupied
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Pass
Remarks:
These need to be in place prior to having renters. (A) The owner shall provide
and install screens for exterior openable windows so that: (1) They are in place
during the period from April 1st through October 31st in each year; (2) They are
no less than 16 mesh per square inch; (3) They cover that part of the window
designed to be opened, except in double hung windows where half screens
shall meet this requirement; and (4) They are tight fitting and prevent the
entrance of pests. (B) Expandable, temporary screens shall not satisfy the
requirements of 105 CMR 410.540(A). (C) The owner shall provide and install
screen doors for all doorways opening directly to the outside from any dwelling
unit or rooming unit where the screen doors will be permitted to slide to the
side or open in an outward direction so that: (1) They are in place during the
period from April 1st through October 31st in each year; (2) They are 16 mesh
per square inch; (3) They are equipped with a self-closing device except where
the screen is designed to open to the side; and (4) They are tight fitting and
prevent the entrance of pests.
410.540 Installation of Screens
*
Result: Pass
410.550 Elimination of Pests
Owners & Occupants are responsible for the control & elimination of pests
Result: Pass
Remarks:
None observed.
410.560 Refuse
*
Result: Pass
410.570 Maintenance of Areas in a Sanitary and Safe
Condition
*
Result: Pass
410.630 Conditions Deemed to Endanger or Materially
Impair Health and Safety
One or more of the violations cited on this report may materially impair the
health or safety and/or well-being of any person(s) occupying the premises
Result: Pass
This inspection report is signed and certified under the pains
and penalties of perjury.
Inspector's signature and date
Result: Pass
Remarks:
Debra Bruinooge-04-01-2024/Update 5-09-2024