Loading...
HomeMy WebLinkAboutSite Plan rev 5-29-24NOTES PROP. MIN. ELEV. 15.0' NAVD1 FOR LOWEST HORIZ. MEMBER PILING FOUNDATION DESIGN BY OTHERS *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM INSULATE PIPE WHERE ABOVE GRADE 4_PVC PIPE \3.2' f 2.58' SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT H-20 2' CAST IRON COVERS TO GRADE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 5.0' MINIMUM .75 OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM NOTE: 2" MIN. WALL THICKNESS REQUIRED PROP. TEE 1 \ 4"PVC PIPESPES LEVEL VEL 1ST 2' 2000 GAL H-20 ' 10" SEPTIC TANK/ ' TEE PUMP CHAMBER COMBINATION °00oo000000 ,a0�o0°00°0� SEE DETAIL BELOW 7.60' 0 0•0 0 o 0 c o 0 0 0 0 0 0 o 0 0 0 0 0 c. 0 0 0 0 0°°°° 0° 0 0 0° 0 0 0 0 0 °o°o°o°o°o°o°o°o°o°o°o°°°°°o°o°o°o°o°o°o° ,o„0_�_0„n��.� 0 0 0 0 0 �_n_'_0_n_0.0 0 ( 2.5 % SLOPE) FOUNDATION 22' VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') (1a): REDUCTION IN SETBACK, SEPTIC TANK TO LOT LINE (10' TO 6') (1 h): REDUCTION IN GROUNDWATER SEPARATION, 5' TO 4' (11): REDUCTION SEPARATION BETWEEN INLET/OUTLET TEES AND HIGH GROUNDWATER UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7): REDUCTION IN SETBACK, SAS TO TCB (100' TO 77.1') VARIANCE OF 2' REQUESTED FROM LATERAL REMOVAL OF UNSUITABLE MATERIAL Yarmouth Conservation Conditions: 1. A hard copy of the plan shall be provided to the Conservation Administrator for review. An electronic copy of the final plan shall be provided to kgrant@yarmouth.ma.us. 2. The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Health Department. 3. A "work limit" line shall be established with Erosion Controls (i.e straw bales, staked filter fabric, bark mulch, "silt sacks," products made with rice straw, and other weed -free products or approved by the Commission.) Hay bales are not allowed. It is the applicant's responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. 4. No work of any kind shall occur on the Resource Area side of the work limit line. This line shall be established prior to any construction or work. 5. All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber, metal, trash, boulders, etc. 6. Debris, including litter, shall be picked up immediately. Any excess material that is excavated from the job site shall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster. No debris shall be allowed in a Wetland or Waterway. 7. Washing of equipment/tools shall be done OFF -SITE or handled in a manner approved by the Conservation Administrator. 8. No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 9. The cesspool is to be pumped dry, the connection broken, and filled with clean sand. 10.Any area that is disturbed during construction shall be revegetated immediately or as soon after as the growing season commences. Permanent stabilization shall be carried out in order to minimize erosion. TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BARRY LEWIS 1 1-30-2023 DATE: ---- -- ___ PERC. RATE _ ___ 2 MIN INCH CLASS __ _.!_ ___ SOILS Q ELEV. 1 05, " 30" FI LL A LS 10YR 3/1 E MS GLEY 1 6/1OY C MS 1OYR 4/6 38" 48" 1, SIEVE 108" G-W ADJ. DATA: WELL: MIW-29 ZONE: A ADJ: 2.3' _4� NOVEMBER 2023 GROUNDWATER ENCOUNTERED AT 56" EL. 0.33 LICE ##23-2 > 8 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) SEPTIC TANK 12' - BUOYANCY CALC: 2000 H-20 TANK WEIGHT: 33,500 LBS 13x 7' x 4.8' x 62.4 = 27,257 UP (OK) e� �0 Q • •r \F� Y � SYSTEM DESIGN: (1.5 % SLOPE) D' BOX 5' •OFFS AFT OFFSET MARK CORNERS OF LEACHING FIELD W/ PROVIDE INSPECTION PORTS TO REBAR SET 4" BELOW WITHIN 3" OF FINISH GRADE GRADE 2% SLOPE \ FILTER FABRIC 8 5' TOP 7.73' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ. CLEAN FILL r- 4• PERFORATED PVC 2s' O.C. S=0.005 ° o 3/4"-1-1/2" DOUBLE WASHED 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-22 5. PIPE JOINTS TO BE MADE WATERTIGHT. 2% MIN. SLOPE OVER SYSTEM 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE 4" LOAM & SEED WITH 310 CMR 15.000 (TITLE 5.) 30"f e CAP STONE UNITS 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY 2" x 5 14" / / OTHER PURPOSE. Irll - Fiberglass 9" COVER-11-I Pins -I' I 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9" STONE LEACHING FIELD ° 6"DEPTH MIN BELOW INV. AS 2•5' 3'f 9. COMPONENTS NOT TO BE BACKFILLED OR LEVEL BOTTOM o 7.13' 6" CONCEALED WITHOUT INSPECTION BY BOARD OF LEACHING FACILITY FMB F`000 < HEAVILY VEGETATED AREA 4flyw EXISTING CONDITIONS GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330__ GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 2000 GAL. DUAL COMPARTMENT SEPTIC TANK/ PUMP CHAMBER LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 10' X 45' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 10' X 45' PIPE AND STONE LEACHING FIELD APPROVED MA DATE BOARD OF HEALTH 45.0' ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 2.58' SEPARATE CIRCUIT FROM PUMP ZABEL FILTER 800) FLOAT SWITCH ALARM ON OUTLETATEE W%EXTENSION SETTINGS: PUMP ON 5" WORKING RANGE 6' 5" PUMP OFF 12" 6.63' 4.0' ADJUSTED GROUNDWATER 2.63' PROPOSED 280 S.F -4-_-- -- MITIGATI \ PLANTI GS� i Q � - r' 2J�vG wool �e AITS Locus Lewis ` Bay PEASTONE - HEALTH AND PERMISSION OBTAINED FROM BOARD OF COARSE SAND BACKFILL AGAINST HEALTH. WALL 40 MIL LINER FROM TOP PEASTONE/WALL 10. CONTRACTOR SHALL BE RESPONSIBLE FOR TO 12" BELOW GRADE CALLING DIGSAFE (811) AND VERIFYING THE LOCATION LOCUS MAP OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR KEYSTONE OR EQUAL RETAINING WALL UNITS TO COMMENCEMENT OF WORK. 18"X8" SET WITH 1" BATTER PER ROW SCALE 1 "=2000't FIBERGLASS PINS REQ. 6"X30" Crushed Rock or 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL Unreinforced Concrete BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 20 PARCEL 26 Leveling Pad req. PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED LOCUS IS WITHIN FEMA FLOOD ZONE VE EL. 13 ON AND REMOVED OR PUMPED AND FILLED WITH CLEAN COMMUNITY PANEL #25001 CO569J DATED 7/16/2014 RETAINING WALL CROSS SECTION SAND. (DESIGN FLOOD ELEVATION = 15.0) 13. FLOOD RESISTANT FOUNDATION DESIGN BY NOT TO SCALE OTHERS. 14 ALL ROOF DRIP LINES SHALL INFILTRATE TO STONE TRENCHES. OWNER OF RECORD 15. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST LISA A DOUGLAS TRUST BENCHMARK: FOLLOW MANUFACTURER'S SPECIFICATIONS FOR 20 WARREN STREET MAG NAIL PROPER FILTER INSTALLATION. MEDFORD, MA 02155 = 4.8' NAVD88 16. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS / SUITABLE FOR PUMP CONNECTION. ELECTRICAL MITIGATION CALCULATIONS: 3' REMOVAL OF UNSUITABLE SOIL REQUIRED PERMIT REQUIRED. AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) �0, �t OFF \PROVIDE 128' OF 40 MIL LINER AT 3' OFF SAS IN AREA SHOWN. TOP AT ELEV. 8.0', TTOM AT EL 3'f ' FT s� \ OFFSET STAKED SILT HEAVILY VEGETATED AREA FENCE WORK LIMIT LINE PROPOSED CONDITIONS HARDSCAPE 0-50' 50-100' EXISTING: BUILDING 799 SF 792 SF DECK 130 SF 19 SF PATIO/DRIVE 1 02SF 250 SF TOTAL: 1031 SF 1061 SF PROPOSED: BUILDING 519 SF 988 SF DECK 163 SF 33 SF PATIO/DRIVE 0 SF 378 SF TOTAL: 682 SF 1399 SF INCREASE: -349 SF 338 SF NET REDUCTION OF 11 SF HARDSCAPE TOTAL MITIGATION PLANTING SCHEDULE SYMBOL PLANT NAME SIZE AMMOPH/LA BREVLIGULATA-280AMERICAN BEACH GRASS0SF HOLE ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 25,000 S.F. 8,835 S.F. 8,835 S.F. MIN. LOT FRONTAGE 150' 105' 105' MIN. FRONT SETBACK 30' 7.4' 31.5' MIN. SIDE SETBACK 15' 23.1' 20.0' MIN. REAR SETBACK 20' 5.2' 6.0' MAX. BUILDING COVERAGE 25% 19.7% (1740 S.F.) 19.3% (1703 S.F.) MAX. BUILDING HEIGHT 35' OF #1 MALFA ROAD COVE 24"CAST IRON WEST YARMOUTH, MA COVERS TOO GRADE 336 GAL. RESERVE PROVIDE QUICK DISCONNECT FOR PUMP PREPARED FOR AND BALL VALVE ANTHONY FEOLA I I NO LOW POINTS DATE: MARCH 28, 2024 2" PRESSURE LINE --F--- REV.: MAY 29, 2024 (HOUSE FOOTPRINT) 19" TEE SLOPE TO DRAIN BACK Scale:1 "= 20' �LZN OF M,gSS9 �,SH OF ly 0.25" WEEP HOLES c`'� DANIEt oyGN o`'�FA P� q�'y{ 0 10 20 30 40 50 FEET MIN. 1500 GAL. CHECK VALVE o� A. `� .� D ' f E ALAi �p off 508-362-4541 O THIS SIDE �� OJALA N u t -, fax 508-362-9880 OF BAFFLE MYERS SRM 4 r:iVl!.. SUBMERSIBLE 4/10 HP PUMP �No.40980� � Na.46502 � downcape.com @ SYSTEM (OR EQUAL) {q�'� SUR�1� ��°fi AST down co.Pe ell iaeefing, 7C. si 000000 0�� oo a000 6" BAFFLE 2000 GAL. LOW PROFILE SEPTIC TANK/ PUMP CHAMBER COMBINATION (NOT TO SCALE) OVAL E civil engineers land surveyors LC 'D 939 Main Street ( Rto 6A) YARMOUTHPORT MA 02675 DRAFTED BY: CJF DATE DANIEL A. OJALA, P.E., P.L.S. CHECKED BY: 23-218