HomeMy WebLinkAboutEningeer PlanTOP FNDN EL. 88-105 SYSTEM PROFILE ACCESS COVER TO WITHIN 6' OF FIN. GRADE <NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO PROVIDE WITHIN 6' OF FIN. GRADE MINIMUM .75' OF COVER OVER PRECAST 27 EXISTING IS 0 GALLON SEPTIC TANK <H- 10 ) (RE -USE) DEPTH OF FLOW = 4' TEE SIZES; 10, INLET DEPTH = OUTLET DEPTH 14' FOUNDATION- EXIST 48_7' RUN PIPE LEVEL /-FOR FIRST 2' 47.2t BAFFLE 45.50' 45.67'J o 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 123) SLOPE) ( 1 + % SLOPE) PROVIDE OBSERVATION PORT WITHIN 6" GRADE IPE REQUIRED OVER SYSTEM _ 48.0' - 49.0' 2' DOUBLE WASHED PEASIONEx - - / 3' MAX. - I I i i r 4 6.0' ac�E�.0008C�0 45.1' 0 CJ C7 0 0 I--] C7 CD C�CI= = mFJC�O 2' y M0=C=l = ==CJCJ 3/4' TO 1 1/2" DOUBLE WASHFF STONE SEPTIC TANK 107' D' BOX , 20„ R0UTi' 6A - 57.6 L.EA:HING G AC"LITY 43.17' 8.6 7' 34.5' TEST HOLE LOGS ENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: _2./7/02 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. Q 0, 48.5' 0' 47.6' A SL A 3„ 10YR 3/2 6" SL 1OYR 3/2 Bw Bw LMS i LMS 20„1 10YR 4/6 46 8' 23" 1OYR 4/6 45.6' C C F/MS F/MS ! 2.5Y 6/4 2.5Y 6/4 168" 134 5' 126" 1 37.1' NO WATER ENCOUNTERED SEPTIC PES!"N: ;GAR".AGE DIS"E'SEP IS DESIGN F _O� ._..� i = DRGOMS ; "l ii u ' E; _ -= .50 L PD USE A 550 &PD DESIGN FLOW SEPTIC TANK�S0 G F D < 2 ) = 1100 USE A 1 �00SiALLON SEPTIC TANK (RE -USE EXISTING) LEACHING: SIDES: 2(A 7.5 + 10.83) 2 (.74) = 172.6 BOTTOM: 47.5 x 10.83 (.;74) = 380.E TOTAL: 747 S.F, 553.2 GPD USE (5) 500 GAL. LEACHING CHAMBERS ACME OR EQUAL) WITH 3' STO l' AT SIDES AND 2.5' AT ENDS EGEND 100.0] PROP,7SED SPOT ELEVATION 100x EXISTING SPPT ELEVATION PROPOSED CONTOUR 100 EXISTING CONTOUR BOARD OF HEALTH MA PROVED DATE qff 509-362-4541 fax 508 362-9880 ;G do wn cape engineering, Inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st, yarmouth, ma 02575 I �ACHCR ShORe RO 0 i Locus � z x RTE 6A N� 9 N z LOCATION MAP NOT TO SCALE ASSESSORS MAP 123 PARCEL 17 NOTES: 1. DATUY IS APPROXIMATED FROM QUAD MAP 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4, DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5, PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8, PIPE FOR SEPTIC SYSTEM TO SCH, 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE <OR FILL W/CLEAN SAND) FAILED LEACH PITS. 11. WATER -TEST D`BOX FOR LEVELNESS OF 302 MAIN STREET (ROUTE 6A) IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: JOHN O'CONNELL 30 0 30 60 90 SCALE: 1" = 30' DATE: FEBRUARY 12, 2002 AN OF ARNE ARNE H. OJALA clviL - 0JALA pF -� Flo. 3U792 E H. OJALA, P.E., P.L.S. VIAR 0 1 2092 HEALTH DEPT. DATE