Loading...
HomeMy WebLinkAboutBLDE-23-003279 Commonwealth of Official Use Only /EAW Massachusetts Permit No. BLDE-23-003279 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/13/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 118 WITCHWOOD RD Owner or Tenant VOUTSELAS RICHARD W Telephone No. Owner's Address 118 WITCHWOOD RD, SOUTH YARMOUTH, MA 02664-1715 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (38 Panels 13.490 KW) Cotnpletion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Tonal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent ____ No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired.or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No, PERMIT FEE: $150.00 2-1(413 a-) RECEIVED '_s , GEC 12 201 ) Official Use Only o manwealflz o�///assachu�e�a 7 p �7 Permit No. ,iil = —__.. _ epa rtment o f we �ervice5 [_'= ILDING DEPARTMENT Occupancy and Fee Checked N J REVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: la O Q City or Town of: '1(, yin C t 0 To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) < < g W ii-t--CJn w 00 CIV P1 Owner or Tenant S` (..jr) j' t v o' 1)+- '„Q 1 cL Telephone No. 0 Owner's Address a Is this permit in conjunction with a building permit? Yes ® No I I (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service ►00 Amps Ian/ 1Volts Overhead NC Undgrd D No.of Meters New Service Amps / Volts Overhead I I Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work c S-tco a-t-i (Yn S' 0 a - oone,C�--ee� co 0�-i-O e Pf S fie. $ cs--k Q 1,,, Completion of following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total 1 Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA ° No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units \ No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones v No.of Detection and No.of Switches No.of Gas Burners Initiating Devices No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals:_ Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal CI Other Connection HeatingAppliances Security Systems:* F.\ No.of Dryers pp h�� No.of bevices or Equivalent No.of Water KW No.of No.of Data Wiring: 44116 Heaters Signs Ballasts No.of Devices or Equivalent dromassa a Bathtubs No.of Motors 1"otal HP Telecommunications Wiring: No.H Y g No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wire.,. Estimated Value of Electrical Work: 18Uj I q •6 J (When required by municipal policy.) S Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. ,...) INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless d the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. ,z1 FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature r w- 7_, LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.•978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner El owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. 0— SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION MI •SYSTEM SIZE:13490W DC,10000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(38)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET WI LTD:LR4-60HPB-355M INSTRUCTIONS. PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL SE10000H-USSN PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 O. SUB-PANEL •SERVICE ENTRANCE CONDUCTORS TO BE REPLACED. •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGEGROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MAIN PANEL REPLACEMENT:EXISTING 100 AMP MAIN PANEL LC PV LOAD CENTER WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 225 AMP MAIN PANEL WITH 200 AMP MAIN BREAKER. •NEW 200A MAIN BREAKER DISCONNECT WITH 200A MAIN •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER ENCLOSURE •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). IAc] AC DISCONNECTS) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. I=1 DC DISCONNECT(S) •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). ABBREVIATIONS I—-1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L_1 SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY s u n ru n AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING FLUSH ATTIC VENT VICINITY MAP 695 uYLES STANDISH BLVD TAUNTON,MA.017004.1 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT DUth PH ONED EXT EXTERIOR METAL PIPE VENT .1:,._.".- - CUSTOMER RESIDENCE: INT INTERIOR T-VENT RICHARD VOUTSELAS MSP MAIN SERVICE PANEL 118 WITCHWOOD RD, INI NEW - SATELLITE DISH bllc HI1 I YARMOUTH,MA,02664 NTS NOT TO SCALE Gland Army of the Repo TEL.(508)922-2203 GC ON CENTER FIRE SETBACKS PRE-FAB PRE-FABRICATED 118 Witchwood Rd, APN:YARM-000078-000200 South Yarmouth, MA... PROJECTR-11VN UT PSF POUNDS PER SQUARE FOOT HARDSCAPE 223R-118VOUT ,_I PV PHOTOVOLTAIC rl.,' 'a DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE —PL- PROPERTY LINE ,ar ' SOLARMODULES 'T" "' �°` RIZWAN ALI TL TRANSFORMERLESS SCALE_NTS YARMOUTH SHEET TYP TYPICAL REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS O - - W WATTS 28 DEN N REV:Al 12/8/2022 L¢❑t.� LAN LANDSCAPE �----SNR MOUNT Q PAGE POR PORTRAIT SNR MOUNT&SKIRT PV-1.0 Txnll.b_hrvon_40.e7 SITE PLAN-SCALE=3/32"=1.-0" SITE PLAN DETAIL-SCALE=1/64"=1°-0" IT111 T (N)ARRAY AR-02-- �MP / v‘- \ on r AC a \ii it (E)RESIDENCE 1 i i 6. Ili11st I lissisti - -O♦ 1111111 (E)RESIDENCE O (N)ARRAY AR-01----------- lis O ♦• ♦ Sail 1111 sunrun #180,20 Stit - (N)ARRAY AR-03 OBS PHONE Es s*u+oisH eLw,rM.wrat un,o2>euTvi P qNE o CUSTOMER RESIDENCE: RICHARD VOUTSELAS 118 WITCHWOOD RD, Z (N)ARRAY AR-04------"------- YARMOUTH,MA,02664 O ARRAY TRUE MAG PV AREA TEL.(508)922-2203 APN:YARM-000078-000200 O PITCH AZIM AZIM (SOFT) AR-01 22' 256° 270° 294.1 PROJECT NUMBER: 223R-118VOUT AR-02 22° 76° 90° 294.1 DESIGNER: (415)580-6920 ex3 AR-03 20° 76° 90° 78.4 RIZWAN ALI AR-04 20° 256° 270° 78.4 SHEET SITE PLAN REV:Al 12/8/2022 PAGE PV-2.0 Tsmpels_wison_0 0 87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Yp 9 YP Detail OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing SNOW LOAD:30 PSF t I WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X4 PRE-FABRICATED TRUSSES 7'-5" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 4'-0" 1'-11" STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 2-Story 2X4 PRE-FABRICATED TRUSSES 7'-5" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 1'-11" STAGGERED 5/16"xl/4"MIN.EMBEDMENT DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X4 RAFTERS 7'-6" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 6'-0" 2'-4" 1'-10" STAGGERED DETAIL SNR-DC-00436 AR-04 COMP SHINGLE-RLU 1-Story 2X4 RAFTERS 7'-6" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 1'-10" STAGGERED DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'-0" AZIM:256° AZIM:76° PITCH:22° PITCH:22° 1'_9"y1.---- 28'-11" _-- 3'-4"I._ 29' ll 10' �, ' N ���� 10'_3" ? VINCENT -.5_...._ ig CIVIL N'. ' ONALC Sign d 12/08/2022 7„ 1 -------11'-7"-------2-7" - 17'-4" sunrun D3-AR-03-SCALE:1/4"=1'-0" D4-AR-04-SCALE:1/4"=1'-0" INSTALLERS SHALL NOTIFY AZIM:76° AZIM:256° #180120 PITCH:20° PITCH:20° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES 695 NTES STANOI...,,TAUNT.,1.06 02790700+ PHONE 0 11'-7" , 2'-6"—J 1'-1" —,—._._ 11'-7" ... ,-3'-2"— OBSERVED PRIOR TO FAA0 PROCEEDING W/ I INSTALLATION. CUSTOMER RESIDENCE: 'IF ARRAY(EXCLUDING SKIRT) RICHARD VOUTSELAS 1'-6" 1'-7" IS WITHIN 12"BOUNDARY 118 WITCH WOOD RD, ❑ ❑ ❑ - - YARMOUTH,MA,02664REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO TEL.(508)922-2203 BE ADDED AND OVERHANG APN:YARM-000078-000200 REDUCED WITHIN THE 12" PROJECT NUMBER: L!!I 6'-10" ❑ - ❑ ❑ 8'-10" BOUNDARY REGION ONLYAS 223R-118VOUT 6 TYP ex3 • I • "ALLOWABLE OVERHANG LAYOUT INDICATED INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE REV.Al 12/8/2022 SEE SITE PLAN FOR NORTH ARROW ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 r.mp.5_vs on_e 0 87 • 120/240 VAC SINGLE PHASE . SERVICE METER#: < O EVERSOURCE 2372798 UTILITY GRID NEW 200A MAIN I BREAKER DISCONNECT ( WITH 200A MAIN ENCLOSURE I NOTE:TOTAL PV BACKFEED=53A --LOAD SIDE TAP USED FOR INTERCONNECTION 14, �- CALCULATIONS (N)LOCKABLE 1 NEW 200A MAIN BLADE TYPE (N)MA SMART BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE10000H-USSN I METER 10000 WATT INVERTER ^ OR EQUIVALENT JUNCTION BOX PV MODULESL O LTD:RE4 N0HP ENERGY T 3p 2 9 LONGI GREEN TECHNOLOGY NEW 225A MAIN < ^ PANEL o,o, F O J `r _ ._._./. �..1 �// (38)MODULES �, --- OPTIMIZERS WIRED IN: FACILITY 80A FUSES ---I I (1)SERIES OF(13)OPTIMIZERS LOADS -z= SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(13)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN (1)SERIES OF(12)OPTIMIZERS 3R,BOA UTILITY SIDE OF CIRCUIT COMPLIANT SOLAREDGE POWER OPTIMIZERS 120/240VAC CONNECTS TO TOP LUGS- P401 (UNE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 $u n r u n 3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 896 MYLES STANDISH BLVD,TAUNTON,ME 02780.7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: RICHARD VOUTSELAS 118 WITCHWOOD RD, YARMOUTH,MA,02664 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)922-2203 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000078-000200 I TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-118VOUT OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580-8920 ex3 RIZWAN ALI SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 13490 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 13 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 12/8/2022 SYSTEM OPERATING CURRENT: 33.73 A SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0 Tempi.,,,,.0 87 NOTES AND SPECIFICATIONS: AWARNING INVERTER 1 •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR PHOTOVOLTAIC DC DISCONNECT IF REQUESTED BY THE LOCAL AHJ. ELECTRICAL SHOCK HAZARD _ •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE MAXIMUM SYSTEM VOLTAGE 480 VDC WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN METHOD AND SHALL NOT BE HAND WRITTEN. LABEL LOCATION: •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). INVOLVED. PER CODE(S):NEC 2020:690.53 •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. INVERTER(S),AC/DC DISCONNECT(S), •DO NOT COVER EXISTING MANUFACTURER LABELS. AC COMBINER PANEL(IF APPUCABLE). PER CODE(S):NEC 2020:690.13(13) WARNING: PHOTOVOLTAIC AWARNING POWER SO IR LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION • UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) AWARNING RAPID SI- OWNSWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM m DO NOT RELOCATE THIS SOLAR PANELS OVERCURRENT DEVICE LOCATION: , INS ALL D WITHIN 3'OF RAPID SHUT DOWN ON ROOF \_� LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). — PER CODE(S):NEC 2020: 4" 705.12(B)(3)(2) AWARNING SOLAR PV SYSTEM EQUIPPED #180120 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN .PHONE HM.,>:SST,�oIsH�Vo,rAUM�,MA,�,�, , COMBINER PANEL N FAX o0 DO NOT ADD LOADS CUSTOMER RESIDENCE: — J LABEL LOCATION: RICHARD VOUTSELAS PHOTOVOLTAIC AC COMBINER(IF118 WITCHWOOD RD, APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN MAIN PANEL (INT) YARMOUTH,MA,02664 SWITCH TO THE"OFF' p p..a. TEL.(508)922-2203 POSITION TO SHUT DOWN F,.._ APN:YARM-000078-000200 in PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE1PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT: 42.0 AMPSSHOCK HAZARD IN THE INVERTER (EXT) L 223R-118VOUT NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. nill PV PRODUCTION METER- SERVICE FUSED AC DISCONNECT- ENTRANCE DESIGNER: (415)5606920 ex3 LABEL AC 118 WITCHWOOD RD, YARMOUTH, MA, 02664 RIZWANALI AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S).NEC 2020 705.10.710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:Al 1218/2022 PER CODE(S):NEC 2020:880.56(C) PAGE PV-5.0 remp.te_a 0n_4087