HomeMy WebLinkAboutBLDE-22-002380 Commonwealth of Official Use Only OIL Massachusetts Permit No. BLDE-22-002380 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/26/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 50 CARVER RD Owner or Tenant Stephanie Abdina Telephone NA job. Owner's Address 50 CARVER ROAD,WEST YARMOUTH, MA 02673 C Is this permit in conjunction with a building permit? Yes 0 No 0 440; I Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 New Service Amps Volts Overhead ❑ Undgrd 0 No.of r Number of Feeders and Ampacity 3 Location and Nature of Proposed Electrical Work: Installation of solar PV system(27 Panels 9.180 KW) / ` Completion of the following table may be waive3the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KWNo.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: PHILIP MCCARRON Licensee: Philip Mccarron Signature LIC.NO.: 14068 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:2 SHAYLEE LN, LAKEVILLE MA 023471852 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 •- Commonwealil'i o/ l' aaaacIZuaeti4 Official Use Only ' ,t #*_' 1, c� Permit No. tZZ — 7-3` 30 -01= T eparimeni o/Jim Service3 QY777Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07) (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 Q (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 9/14/2021 U City or Town of: Yarmouth MA To the Inspector of Wires: o By this application the undersigned gives notice of his or her intention to perform the electrical work described below. 0 Location(Street&Number) 50 Carver Road Owner or Tenant Stephanie Abdina Telephone No. EOwner's Address Same 6. Is this permit in conjunction with a building permit? Yes 1 No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 200 Amps 120 / 240Volts Overhead ❑✓ Undgrd❑ No.of Meters New Service Amps / Volts Overhead Undgrd ❑ No.of Meters Number of Feeders and Ampacity g Location and Nature of Proposed Electrical Work: Installation of 27 solar PV modules of existing roof. 9,180 kW Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T Transformers KVA �/� No.of Luminaire Outlets No.of Hot Tubs Generators KVA a.; No.of Luminaires Swimming Pool Above ❑ In- ❑ No. Bat of"tery EmergencyUnits Lighting �-- grnd. grnd. No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No. Initiating of Detectionand Devices No.of Ranges No.of Air Cond. Total Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other p Connection No.of Dryers Heating Appliances KW Securit y Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Solar PV Installation Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $8000 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury, that the information on this application is true and complete. FIRM NAME: Beacon Solar Construction LIC.NO.: Licensee: Philip McCarron Signature X P � LIC.NO.: A14068 (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.: 508-930-1405 Address: 2 Shaylee Lane, Lakeville, MA 02347 Alt.Tel.No.: *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. B my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent L��. 401 203 4854 Signature t Telephone No. PERMIT FEE: $ ti .. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS •SYSTEM SIZE:9180W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES PAGE •MODULES:(27)JA SOLAR:JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SE SERVICE ENTRANCE # DESCRIPTION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. SE7600H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-1.0 COVER SHEET •RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. SNR MOUNT PV-2.0 SITE PLAN •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. PV-3.0 LAYOUT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER [M CHIMNEY PV-4.0 ELECTRICAL •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER t'1 ATTIC VENT •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PV-5.0 SIGNAGE Ell FLUSH ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER MODULES,ARE CLASS A FIRE RATED. c PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 5 METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 113) T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IAC I AC DISCONNECT(S) cp SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC DC DISCONNECT(S) ' FIRE SETBACKS •10.46 AMPS MODULE SHORT CIRCUIT CURRENT. I�I �L//1. •16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. O CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC' ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 � (E) EXISTING 734 FOREST srREETu ,MARLOGROUGH.ru 01752 PHONE 886.6578527 ESS ENERGY STORAGE SYSTEM FAX 805 528 9701 EXT EXTERIOR e INT INTERIOR CUSTOMER RESIDENCE: .16 MAG MAGNETIC STEPHANIE ABDINA 44' a MSP MAIN SERVICE PANEL 50 CARVER RD,YARMOUTH, 8 fayt (N) NEW MA,02673 �4 NTS NOT TO SCALE ,e _RM OC ON CENTER TEL.(857)399-5230 5o C uvc Rd PRE-FAB PRE-FABRICATED APN#:YARM-000030-000049 I writ YA$Mottn,Ma... PSF POUNDS PER SQUARE FOOT "",,»,„, <4115, ° PV PHOTOVOLTAIC PROJECT NUMBER: "� RSD RAPID SHUTDOWN DEVICE 221 R-0SOABDI 1 • TL TRANSFORMERLESS al5 580 6920 ex3 rim c5t / TYP TYPICAL DESIGNER: ( ) V VOLTS AUDREY EINFELDT k ~+ W WATTS SHEET s REV NAME DATE COMMENTS COVER SHEET ,s'',Wa., ;/ cS'''`xc ./- I REV:Al 8/31/2021 PAGE PV-1.0 • L Q 1 W H v, N 1 CO N N ;M W O Z 5U o Z Q �Q N a ❑�} o a' V o ---I O N a (�0 0 o LU m w d CV W2 C I �Q[r . o 20 Z W 7 G W W iy Q 7m W I-' 11 N N e- mw a>6- M Q F-� w } O 12t =0'N r 01 O Z W <V o otin N W� OF W Ua } �� U' p W > W Qa N N �'¢ 7Uu0i� W d KN U 7 2 W Q x e. 0 F Q d N O a N K 6. '- N 9 O w U z W o N O m (n Q re } Lii W ce Q )a Q / • Z_ 3 W ce • W ev. • e - �V_ : / &I*, .„, • ' • °e4" 4rSir ' • CN 410b , �a o cr f W 7 4- OF =7 QU Zo' I-7 7 I CO W vfJ a d Oa o U� < Q a} 4 z ce Q II ? iO II J U to z a F_W- al. rn \. .' ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF ,SPEEDSEAL TRACK ON WIND SPEED: RL UNIVERSAL AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-10" 16" 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-10" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 5/16"X4.5":2.5"MIN EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:3/16"=1'-0" ENGINEER OF ANY PITCH:21° POTENTIAL STRUCTURAL AZIM:208° ISSUES OBSERVED PRIOR 19'-11" 5'-9^ I 6'-7" I I-1-10" TO PROCEEDING W/ INSTALLATION. ?' • IF ARRAY(EXCLUDING - - - - II ❑ 0 ❑ SKIRT)IS WITHIN 124'TYP_kBOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE I ADDED AND OVERHANG11-2III L_ _._ •❑ 0. 0 REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% • C) n n •• ALLOWABLE OVERHANG 2'-2" INDICATED ON PLANS TO I BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:3/16"=1'-0" PITCH:21° AZIM:28° s u n r u n 6"'i' 28' - 10'-3" 1 #180120 3'-1" I -- 1 i >N M FOREST STREET O,MARLBOROUGH,MA 01752 �..._.... �__ PIKKE959 fi57657 - ❑ El ❑ ❑. ❑ ❑ ❑ FAX 005.520.9701 }-5'-0"TYP—} CUSTOMER RESIDENCE: STEPHANIE ABDINA ❑ ❑ e B {� 0 ❑ 50 CARVER RD,YARMOUTH, MA,02673 9'-11" TEL.(857)399-5230 ❑ ❑ a- B ❑ n 0 n STRUCT L APN#:YARM-000030-000049 ONL o soft OFM4s PROJECT NUMBER: 0 C) n 6 VINCENT oG� —.. 221R-OSOABDI 1 6 MWUMVANEZA ,DESIGNER: (415)580-6920 ex3 CIVIL — AUDREY EINFELDT :j"�%: fatE��,°`"e SHEET •' 640,LL.1 LAYOUT REV:Al 8/31/2021 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE OMETER#: EVERSOURCE 2282603 UTILITY GRID EXISTING C 1 200A MAIN BREAKER (END FED) SOLAREDGE TECHNOLOGIES: ------N EXISTING SE7600H-US WITH REVENUE �� 200A (N)MA SMART GRADE METERING(PN MAIN UTILITY (N)LOCKABLE SE7600H-USS3),7600 WATT FACILITY PANEL REVENUE BLADE TYPE INVERTER LOADS METER AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES �j OR EQUIVALENT 1 JA SOLAR:JAM60S10-340IMR i ttt / (27)MODULES O o�s—o `� _ .--./. I + O�2 OPTIMIZERS WIRED IN: J - (1)SERIES OF(14)OPTIMIZERS I (1)SERIES OF(13)OPTIMIZERS "FACILITY (N)40A =GROUND 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT PV BREAKER AT 100A CONTINUOUS DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END UTILITY SIDE OF CIRCUIT 3R,60A,2P COMPLIANT P340 OF BUSBAR CONNECTS TO TOP LUGS- 120/240VAC (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE s u n r u n # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER — 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)8 AWG THHN/THWN-2 #180120 731 FOREST STREET HUU.MARLBOROUGH.MA 01752 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 1 10 AWG THHN/THWN-2 PHONE 66B 65)6527 ( ) (1)8 AWG THHN(fHWN-2 FAX SO5.523.3701 CUSTOMER RESIDENCE: STEPHANIE ABDINA 50 CARVER RD,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(857)399-5230 JA SOLAR:JAM60S10-340/MR: 340 W P340 OPTIMIZER CHARACTERISTICS: APN#:YARM 000030 000049 OPEN CIRCUIT VOLTAGE: 41.55 V MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 48 VDC PROJECT NUMBER: MAX POWER VOLTAGE 34.73 V MAX INPUT ISC: 11 ADC 221R-O5OABDI SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 AUDREY EINFELDT SYSTEM SIZE: 9180 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/31/2021 SYSTEM OPERATING CURRENT: 22.95 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 ®• � p .� ; INVERTER 1 NOTES AND SPECIFICATIONS: a,s & u'', •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020.690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC DISCONNECT(S).AC SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED. COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S).NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC s`j „,„,,,,— POWER ( URGE \ LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020.690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN I SERVICE PANEL. PER CODES)NEC 2020 705 12(C) cAtijirIoN • ��� \ ,„ gam.}".: :_. \. )..J� I\i 1 . .,.. \NNa'Nam\ 1,N POWER SOURCE OUTPUT CONNECTION T" _ _ x.. ° DO NOT RELOCATE THIS MULTIPLE SOURCES OF POWER OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN!AB -- SOLAR PANELS ON ROOF AL LOCATION: SWITCH012: PER CODE(S):2019: 2020:690.56(C)(2),IFC I I Iho s u n r u n ADJACENT TO IC BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 ill -- OCPD(IF APPLICABLE). PER CODE(S):NEC 2020. L...._._....__ __..__.__ _..____ .._q ......_._._ _. .._..__. .._._.......... __....} 70512(B)(3)(2) III -- A (off MIN #180120 � SOLAR PV SYSTEM EQUIPPED II MN ID.1 FOREST STREET MO,MARLBONWGHMAO„, PHOTOVOLTAIC SYSTEM „ -- vrareeessze,n COMBINER PANEL WITH RAPID SHUTDOWN ,��s,o, DO NOT ADD LOADS CUSTOMER RESIDENCE: 1 STEPHANIE ABDINA LABEL LOCATION: I 'II-. 50 CARVER RD,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF MA,02673 APPLICABLE). PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3, TURN RAPID SHUTDOWN TEL.(857)399-5230 •: PV PAWLS SWITCH TO THE"OFF" INVERTER (EXT) 1 POSITION TO SHUT DOWN APN#:YARM-000030-000049 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT PROJECT NUMBER: j SHOCK HAZARD IN THE 221 R-050ABDI MAXIMUM AC OPERATING CURRENT:31.67 AMPS ARRAYEll. SMART METER NOMINAL OPERATING AC VOLTAGE. 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: SERVICE ENTRANCE AND PV AUDREY EINFELDT AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. BREAKER DISCONNECT SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING ARE CONNECTED. TO WHICH THE PV SYSTEMS 50 CARVER RD, YARMOUTH, MA, 02673 REV:Al 8/31/2021 PER CODE(S):NEC 2020:690.56(C) PAGE PER CODE(S):NEC 2020:705.10,710.10 PV-5.0