APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/26/2021
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 50 CARVER RD
Owner or Tenant Stephanie Abdina Telephone NA job.
Owner's Address 50 CARVER ROAD,WEST YARMOUTH, MA 02673 C
Is this permit in conjunction with a building permit? Yes 0 No 0 440; I
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0
New Service Amps Volts Overhead ❑ Undgrd 0 No.of r
Number of Feeders and Ampacity 3
Location and Nature of Proposed Electrical Work: Installation of solar PV system(27 Panels 9.180 KW)
/ `
Completion of the following table may be waive3the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KWNo.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: PHILIP MCCARRON
Licensee: Philip Mccarron Signature LIC.NO.: 14068
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address:2 SHAYLEE LN, LAKEVILLE MA 023471852 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
•- Commonwealil'i o/ l' aaaacIZuaeti4 Official Use Only
' ,t #*_' 1, c� Permit No. tZZ — 7-3` 30
-01= T eparimeni o/Jim Service3
QY777Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07) (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
Q (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 9/14/2021
U City or Town of: Yarmouth MA To the Inspector of Wires:
o By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
0 Location(Street&Number) 50 Carver Road
Owner or Tenant Stephanie Abdina Telephone No.
EOwner's Address Same
6. Is this permit in conjunction with a building permit? Yes 1 No ❑ (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service 200 Amps 120 / 240Volts Overhead ❑✓ Undgrd❑ No.of Meters
New Service Amps / Volts Overhead Undgrd ❑ No.of Meters
Number of Feeders and Ampacity g
Location and Nature of Proposed Electrical Work: Installation of 27 solar PV modules of existing roof.
9,180 kW
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T
Transformers KVA
�/� No.of Luminaire Outlets No.of Hot Tubs Generators KVA
a.; No.of Luminaires Swimming Pool Above ❑ In- ❑ No.
Bat of"tery EmergencyUnits Lighting
�-- grnd. grnd.
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No. Initiating of Detectionand
Devices
No.of Ranges No.of Air Cond. Total
Tons No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other
p Connection
No.of Dryers Heating Appliances KW Securit y Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER: Solar PV Installation
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $8000 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify, under the pains and penalties of perjury, that the information on this application is true and complete.
FIRM NAME: Beacon Solar Construction LIC.NO.:
Licensee: Philip McCarron Signature X P � LIC.NO.: A14068
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.: 508-930-1405
Address: 2 Shaylee Lane, Lakeville, MA 02347 Alt.Tel.No.:
*Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic. No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. B my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent L��. 401 203 4854
Signature t Telephone No. PERMIT FEE: $
ti ..
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
•SYSTEM SIZE:9180W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES PAGE
•MODULES:(27)JA SOLAR:JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SE SERVICE ENTRANCE # DESCRIPTION
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS.
SE7600H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-1.0 COVER SHEET
•RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL
TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
SNR MOUNT PV-2.0 SITE PLAN
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. PV-3.0 LAYOUT
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER [M CHIMNEY
PV-4.0 ELECTRICAL
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER t'1 ATTIC VENT
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PV-5.0 SIGNAGE
Ell FLUSH ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER
MODULES,ARE CLASS A FIRE RATED. c PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) 5 METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 113) T-VENT
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IAC I AC DISCONNECT(S)
cp SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
DC DISCONNECT(S) ' FIRE SETBACKS
•10.46 AMPS MODULE SHORT CIRCUIT CURRENT. I�I �L//1.
•16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. O CB IQ COMBINER BOX HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE:NTS
A AMPERE s u n r u n
AC ALTERNATING CURRENT
AFC' ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION
DC DIRECT CURRENT #180120
� (E) EXISTING 734 FOREST srREETu ,MARLOGROUGH.ru 01752
PHONE 886.6578527
ESS ENERGY STORAGE SYSTEM FAX 805 528 9701
EXT EXTERIOR
e INT INTERIOR CUSTOMER RESIDENCE:
.16 MAG MAGNETIC STEPHANIE ABDINA
44' a MSP MAIN SERVICE PANEL 50 CARVER RD,YARMOUTH,
8 fayt (N) NEW MA,02673
�4 NTS NOT TO SCALE
,e _RM OC ON CENTER TEL.(857)399-5230
5o C uvc Rd PRE-FAB PRE-FABRICATED APN#:YARM-000030-000049
I writ YA$Mottn,Ma... PSF POUNDS PER SQUARE FOOT
"",,»,„, <4115, ° PV PHOTOVOLTAIC PROJECT NUMBER:
"� RSD RAPID SHUTDOWN DEVICE 221 R-0SOABDI 1
• TL TRANSFORMERLESS al5 580 6920 ex3
rim c5t / TYP TYPICAL DESIGNER: ( )
V VOLTS AUDREY EINFELDT
k
~+ W WATTS SHEET
s REV NAME DATE COMMENTS COVER SHEET
,s'',Wa., ;/ cS'''`xc
./- I REV:Al 8/31/2021
PAGE PV-1.0
• L
Q 1
W H v,
N
1 CO N N ;M W O Z
5U o
Z Q
�Q N a ❑�} o a' V o ---I
O
N a (�0 0 o LU m w d CV
W2 C I
�Q[r . o 20 Z W
7 G W W iy Q 7m W I-' 11
N N e- mw a>6- M Q F-� w }
O 12t =0'N r 01
O Z W
<V o otin
N W� OF W Ua } �� U' p W > W
Qa N N �'¢ 7Uu0i� W d KN U 7 2 W Q
x e. 0 F Q d N O a N K 6.
'- N
9 O
w
U
z W o
N
O m
(n Q
re
}
Lii
W ce
Q )a Q
/ •
Z_
3
W
ce
• W
ev. •
e - �V_ :
/ &I*, .„, •
' • °e4" 4rSir ' •
CN 410b ,
�a
o
cr
f
W 7 4-
OF
=7
QU Zo'
I-7
7 I
CO
W
vfJ a d
Oa o
U� <
Q
a}
4 z ce
Q
II ?
iO
II
J
U
to
z
a
F_W- al.
rn \.
.'
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF
Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
,SPEEDSEAL TRACK ON WIND SPEED:
RL UNIVERSAL AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-10" 16" 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 140 MPH 3-SEC GUST.
COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 13'-10" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 1'-11" STAGGERED 5/16"X4.5":2.5"MIN EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES:
INSTALLERS SHALL NOTIFY
D1-AR-01-SCALE:3/16"=1'-0" ENGINEER OF ANY
PITCH:21° POTENTIAL STRUCTURAL
AZIM:208° ISSUES OBSERVED PRIOR
19'-11" 5'-9^ I 6'-7" I I-1-10" TO PROCEEDING W/
INSTALLATION.
?' • IF ARRAY(EXCLUDING
- - - - II
❑ 0 ❑ SKIRT)IS WITHIN 124'TYP_kBOUNDARY REGION OF ANY
ROOF PLANE EDGES
(EXCEPT VALLEYS),THEN
ATTACHMENTS NEED TO BE
I ADDED AND OVERHANG11-2III
L_ _._ •❑ 0. 0 REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS
FOLLOWS:
••ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
• C) n n •• ALLOWABLE OVERHANG
2'-2" INDICATED ON PLANS TO
I BE 1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
D2-AR-02-SCALE:3/16"=1'-0"
PITCH:21°
AZIM:28° s u n r u n
6"'i' 28' - 10'-3"
1 #180120
3'-1" I --
1 i >N M FOREST STREET O,MARLBOROUGH,MA 01752
�..._.... �__ PIKKE959 fi57657
- ❑ El ❑ ❑. ❑ ❑ ❑ FAX 005.520.9701
}-5'-0"TYP—} CUSTOMER RESIDENCE:
STEPHANIE ABDINA
❑ ❑ e B {� 0 ❑ 50 CARVER RD,YARMOUTH,
MA,02673
9'-11"
TEL.(857)399-5230
❑ ❑ a- B ❑ n 0 n STRUCT L APN#:YARM-000030-000049
ONL
o soft OFM4s PROJECT NUMBER:
0 C) n 6 VINCENT oG�
—.. 221R-OSOABDI
1 6 MWUMVANEZA ,DESIGNER: (415)580-6920 ex3
CIVIL
— AUDREY EINFELDT
:j"�%: fatE��,°`"e SHEET
•' 640,LL.1 LAYOUT
REV:Al 8/31/2021
PAGE PV-3.0
120/240 VAC
SINGLE PHASE
SERVICE
OMETER#:
EVERSOURCE 2282603
UTILITY
GRID EXISTING
C 1 200A MAIN
BREAKER
(END FED)
SOLAREDGE TECHNOLOGIES:
------N EXISTING SE7600H-US WITH REVENUE
�� 200A (N)MA SMART GRADE METERING(PN
MAIN UTILITY (N)LOCKABLE SE7600H-USS3),7600 WATT
FACILITY
PANEL REVENUE BLADE TYPE INVERTER
LOADS METER AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES
�j OR EQUIVALENT 1 JA SOLAR:JAM60S10-340IMR
i ttt / (27)MODULES
O o�s—o `� _ .--./. I + O�2 OPTIMIZERS WIRED IN:
J - (1)SERIES OF(14)OPTIMIZERS
I (1)SERIES OF(13)OPTIMIZERS
"FACILITY
(N)40A =GROUND 240V METER SOCKET SQUARE D LOAD RATED DC DISCONNECT
PV BREAKER AT 100A CONTINUOUS DU222RB WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
OPPOSITE END UTILITY SIDE OF CIRCUIT 3R,60A,2P COMPLIANT P340
OF BUSBAR CONNECTS TO TOP LUGS- 120/240VAC
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE s u n r u n
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)6 AWG BARE COPPER
—
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)8 AWG THHN/THWN-2 #180120
731 FOREST STREET HUU.MARLBOROUGH.MA 01752
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 1 10 AWG THHN/THWN-2 PHONE 66B 65)6527
( ) (1)8 AWG THHN(fHWN-2
FAX SO5.523.3701
CUSTOMER RESIDENCE:
STEPHANIE ABDINA
50 CARVER RD,YARMOUTH,
MA,02673
MODULE CHARACTERISTICS TEL.(857)399-5230
JA SOLAR:JAM60S10-340/MR: 340 W P340 OPTIMIZER CHARACTERISTICS: APN#:YARM 000030 000049
OPEN CIRCUIT VOLTAGE: 41.55 V MIN INPUT VOLTAGE: 8 VDC
MAX INPUT VOLTAGE: 48 VDC PROJECT NUMBER:
MAX POWER VOLTAGE 34.73 V MAX INPUT ISC: 11 ADC 221R-O5OABDI
SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC
DESIGNER: (415)580-6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1
AUDREY EINFELDT
SYSTEM SIZE: 9180 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 400 V
MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 8/31/2021
SYSTEM OPERATING CURRENT: 22.95 A
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
®•
� p .� ; INVERTER 1 NOTES AND SPECIFICATIONS:
a,s & u'', •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020.690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC DISCONNECT(S).AC SIGNS AND LABELS.UNLESS OTHERWISE SPECIFIED.
COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S).NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
s`j „,„,,,,— POWER ( URGE
\ LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020.690.31(0)(2),IFC 2012:
SYSTEM 605.11.1.4
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN I
SERVICE PANEL.
PER CODES)NEC 2020 705 12(C) cAtijirIoN •
��� \ ,„ gam.}".: :_. \. )..J� I\i 1
. .,.. \NNa'Nam\ 1,N
POWER SOURCE OUTPUT CONNECTION T" _ _ x.. °
DO NOT RELOCATE THIS MULTIPLE SOURCES OF POWER
OVERCURRENT DEVICE LABEL LOCATION:
INSTALLED WITHIN 3'OF RAPID SHUT DOWN!AB -- SOLAR PANELS ON ROOF
AL LOCATION: SWITCH012: PER CODE(S):2019: 2020:690.56(C)(2),IFC I I Iho s u n r u n
ADJACENT TO IC BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 ill --
OCPD(IF APPLICABLE).
PER CODE(S):NEC 2020. L...._._....__ __..__.__ _..____ .._q ......_._._ _. .._..__. .._._.......... __....}
70512(B)(3)(2) III --
A (off MIN #180120
� SOLAR PV SYSTEM EQUIPPED II MN ID.1 FOREST STREET MO,MARLBONWGHMAO„,
PHOTOVOLTAIC SYSTEM „ -- vrareeessze,n
COMBINER PANEL WITH RAPID SHUTDOWN ,��s,o,
DO NOT ADD LOADS CUSTOMER RESIDENCE:
1 STEPHANIE ABDINA
LABEL LOCATION: I 'II-. 50 CARVER RD,YARMOUTH,
PHOTOVOLTAIC AC COMBINER(IF MA,02673
APPLICABLE).
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3, TURN RAPID SHUTDOWN TEL.(857)399-5230
•: PV PAWLS SWITCH TO THE"OFF" INVERTER (EXT)
1 POSITION TO SHUT DOWN APN#:YARM-000030-000049
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT PROJECT NUMBER:
j SHOCK HAZARD IN THE 221 R-050ABDI
MAXIMUM AC OPERATING CURRENT:31.67 AMPS ARRAYEll. SMART METER
NOMINAL OPERATING AC VOLTAGE. 240 VAC DESIGNER: (415)580-6920 ex3
LABEL LOCATION: SERVICE ENTRANCE AND PV AUDREY EINFELDT
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. BREAKER DISCONNECT SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION SIGNAGE
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
DISCONNECTING ARE CONNECTED.
TO WHICH THE PV SYSTEMS 50 CARVER RD, YARMOUTH, MA, 02673
REV:Al 8/31/2021
PER CODE(S):NEC 2020:690.56(C)
PAGE
PER CODE(S):NEC 2020:705.10,710.10 PV-5.0