Loading...
HomeMy WebLinkAboutInspection Report 216 Higgins Crowell Rd 2024Town of Yarmouth, MA Inspection Report Inspection: Inspection Inspector: Logan Patrick Inspection Date: Jun 3, 2024 Record: Rental Registration #BHR-24-677 Location: 216 HIGGINS CROWELL RD, WEST YARMOUTH, MA 02673 Applicant: Ruyter Neves Jr. Rental Inspection Overall Result: Fail Overall Remarks: Inspection is for Unit A - left side. Owner has configured Side A to have 4 Bedrooms. (2nd Flr front right room cannot be used as a bedroom.) Owner occupied Side B has a bedroom. Septic system is designed for 4 bedrooms total. Must eliminate 1 bedroom or increase septic system size if feasible. Checklist: 1. Number of Bedrooms Result: Pass Remarks: 4 All 2nd Floor Front Left: 10.5 x 9.4 = 98.7 sq ft - 1 person Rear Left: 11.0 x 10.9 = 119.9 sq ft - 2 people Rear Right: 9.3 x 10.3 = 95. 8 sq ft - 1 person Front Right: 10.6 x 8.0 = 84.5 sq ft - 1 person 2. Maximum Occupancy: Based on septic system capacity, number of bedrooms and bedroom square footage Result: Pass Remarks: Four (4) - Shared septic system between A & B is for a 4 bedroom. Unit B is owner occupied and has 1 bedroom in basement. Unit A has 4 bedrooms. This puts duplex over septic calculations. 3. Basement Result: Pass Remarks: Finished. Unsecured connection with Side B's finished side. Has a working sink on side A. 4. Electrical Panel Result: Pass Remarks: Labeled 5. Copy of Tenant's Legal Rights have been issued to tenant. Result: Pass 105CMR 410.00 0Minimum Standards of Fitness for Human Habitation (State Sanitary Code: Chapter II) Result: Pass 410.100 Kitchen Facilities * Result: Fail Remarks: Replace broken floor tiles. Install threshold/transition strip at intersection with dining area. 410.110 Bathroom Facilities : Sinks, Toilets, Tubs & Showers * Result: Pass Remarks: Two Bathrooms. (See Natural and Mechanical Ventilation) 410.120 Approved Toilets * Result: Pass 410.130 Water supply Potable Water/Sanitary Drainage Result: Pass 410.140 Plumbing Connections * Result: Pass 410.150 Hot Water 110-130 °F for faucets & 110-120 °F for bathtubs a & showers Result: Pass 410.160 Heating Systems * Result: Pass 410.170 Venting * Result: Pass 410.180 Temperature Requirements Owner shall proved heat in every habitable room & every room containing a toilet, shower or bathtub from September 15th through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am to 11:00 pm Result: Pass 410.200 Provision and Metering of Electrical or Gas * Result: Pass 410.210 Provision of Oil * Result: Skip 410.220 Natural and Mechanical Ventilation * Result: Fail Remarks: Exhaust fans in both bathrooms require cleaning. 410.230 Owner's Laundering Responsibilities If owner provides bed linens, towels, pillows or mattress Result: Skip 410.235 Owner's Installation, Maintenance and Repair Responsibilities * Result: Fail Remarks: Dishwasher is not operational. 410.240 Occupant's Installation and Maintenance Responsibilities * Result: Pass Remarks: None observed. 410.250 Asbestos-containing Material * Result: Skip Remarks: None observed. 410.260 Means of Egress * Result: Pass 410.270 Locks * Result: Fail Remarks: Door between units is not lockable. Owner to install a lock. 410.310 Auxiliary Emergency Lighting Systems & Exit Signs For properties with 10 or more units Result: Skip 410.320 Electrical Service Temporary Wiring, Amperage Result: Fail Remarks: Install missing coverplates in Right Rear bedroom and in attic space. 410.330 Smoke Detector and Carbon Monoxide Alarms * Result: Fail Remarks: Smoke Alarms and CO Detectors need to be relocated no more than 10' feet from a bedroom. 410.400 Owner/Manager Contact Information and Notice of Occupants' Legal Rights and Responsibilities Contact information and postings inside and outside of home Result: Pass 410.410 Building Identification * Result: Pass 410.420 Habitability Requirements Result: Pass 410.430 Natural Light and Obstructions * Result: Pass 410.470 Lead-based Paint Hazards in Residence * Result: Skip 410.500 Owner Responsibility to Maintain Building & Structural Elements * Result: Fail Remarks: Repair chimney above roofline. 410.510 Occupant 's Responsibility Regarding Building and Structural Elements * Result: Pass 410.520 Protective Railings and Walls * Result: Fail Remarks: Properly install protective rails at 2nd French Doors openings. Eliminate ladder-effect of current 2x4's. 410.530 Weather-tight elements * Result: Pass 410.540 Installation of Screens * Result: Fail Remarks: Install screens in all windows that open to the exterior. Install screen door (storm is acceptable) at rear door. Install screen on 2nd Flr French Doors - Right Rear Bedroom 410.550 Elimination of Pests Owners & Occupants are responsible for the control & elimination of pests Result: Fail Remarks: Owner to continue removing brush piles, tree limbs, yard debris from side and rear yard. Eliminate pest harborage. 410.560 Refuse * Result: Fail Remarks: Owner to continue removing brush piles, tree limbs, yard debris from side and rear yard. Eliminate pest harborage. 410.570 Maintenance of Areas in a Sanitary and Safe Condition * Result: Fail Remarks: See 410.560 Refuse 410.630 Conditions Deemed to Endanger or Materially Impair Health and Safety One or more of the violations cited on this report may materially impair the health or safety and/or well-being of any person(s) occupying the premises Result: Fail Remarks: Professionally treat mold/mildew in Left Rear Bedroom by a Mold Remediator. This inspection report is signed and certified under the pains and penalties of perjury. Inspector's signature and date Result: Pass Remarks: Logan Patrick 06/03/2024