HomeMy WebLinkAboutBLDE-23-001914 r--Lae) Commonwealth of Official Use Only
#'2 Massachusetts Permit No. BLDE-23-001914
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/11/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 32 TOWN BROOK RD
Owner or Tenant ELAINE MALCOM Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (31 Panels 11.005 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER ❑ (Specify:)
I certify,under the pains and penalties ofperjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
/`'iNaL lie '2/4e/4:AA,.
_ RECEIVED
<1I C Official Use Only
_ 11 2022 m .nwea th o aiiac uietts k i1----___ 4
# __ CT 1 L c�77 ��ii Permit No.
=r * - _ ___ ._-. ear
o� }ire Jeretce9
e'; k_01NG DEPARTMENT Occupancy and Fee Checked
• ',C D-e.»•�' - PREVENTION REGULATIONS [Rev. 1/07]— ' j (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 101 b(p/ 'X?
City or Town of: jar mpU.a h To the Inspector of Wires:
CBy this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 3a Town 00,kI ECI
Owner or Tenant f✓l(1.l ile. mQuCo Telephone No.17y 3bg 37 L
" Owner's Address S(l Q as Q✓_e
Is this permit in conjunction with a building permit? Yes ki No ❑ (Check Appropriate Box)
Purpose of Building Utility Authorization No.
cExisting Service I Co 0 Amps 1 a.G / L1(1 Volts Overhead [A] Undgrd n No.of Meters
J New Service Amps / Volts Overhead❑ Undgrd No.of Meters
Number of Feeders and Ampacity ^^II
J Location and Nature of Proposed Electrical Work: jl'lS+elll(l+i Onnc. an ►`,1-�e,C'<6Y1Y1[.C+(1�1
' rcxi-a, IA/ 5t35-tc.►1 N eal-i i c 11 .no 6 V-Ilio
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Sus Paddle Fans No.of Total
p (Paddle) Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
Q. grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
of
No.of Switches No.of Gas Burners No. Initiatinnggon Dete and
In Devices
No.of Ranges • No.of Air Cond. Total
g No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers S ace/Area Heatin KW Local❑ Municipal ❑ Other
P g Connection
No.of Dryers Heating Appliances KW. Security Systems:'
i
No.of Water No.of No.of Data Wiring:
Heaters KW No.of Devices or Equivalent
Signs Ballasts No.of Devices or Equivalent
c No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring:
Y g No.of Devices or Equivalent
J OTHER:
C5 Attach additional detail if desired,or as required by the Inspector of Wires.
D Estimated Value of Electrical Work: 'Snag .0 0 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
-47 INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: &WW1 Installation Services LIC.NO.:4316 Al
Licensee: Nathan Ashe Signature LIC.NO.:21136A
�-�. (if applicable.enter "exempt"in the license number line.) Bus.Tel.No.•978-594-3519
Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent PERMIT FEE: $
Signature Telephone No.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:11005W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES
•MODULES:(31)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION ® SERVICE ENTRANCE PV-1.0 COVER SHEET
LTD:LR4-6OHPB-355M INSTRUCTIONS. PV-2.0 SITE PLAN
MP
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. u I
SE7600H-USSN MAIN PANEL ° 9,
q PV-3.0 LAYOUT
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436 -SNR MOUNT tl
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL -- SNR MOUNT&SKIRT
PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. /A, ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER [..._' FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) cv METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
T-VENT
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S)
n SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
•11.25 AMPS MODULE SHORT CIRCUIT CURRENT.
0 DC DISCONNECT(S) FIRE SETBACKS
•17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX I ,I HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE -1 E INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE:NTS
A AMPERE s u n r u n
AC ALTERNATING CURRENT
AFC) ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION #180120
DC DIRECT CURRENT
Varmc... (E) EXISTING SMi WILES STANDISH BLVD.TAUNTON.MP 02780-',^
ESS ENERGY STORAGE SYSTEM
3'^stable FA%0 u
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
Weld qnr y of the RevRevak.� 'tie MAG MAGNETIC ELAINE MALCOLM
MSP MAIN SERVICE PANEL 32 TOWN BROOK RD,
(N) NEW YARMOUTH,MA,02673
NTS NOT TO SCALE
OC ON CENTER TEL. 368-378
PRE-FAB PRE-FABRICATED APN:(YARM 000037-000b86
',ARM,.• PSF POUNDS PER SQUARE FOOT PROJECT NUMBER:
Town Brook Rd, PV PHOTOVOLTAIC
aJ RSD RAPID SHUTDOWN DEVICE 223R-032MALC
,':est Yarmouth,MA.es TL TRANSFORMERLESS
7° TYP TYPICAL DESIGNER: (415)580-6920 ex3
Mr.nr.r MT.. V
W VOLTS
WATTS MOHD TARIK
v.a WESsn
SHEET
REV NAME DATE COMMENTS COVER SHEET
REV A 10/6/2022
PAGE PV-1.0
I
ARRAY TRUE MAG PVAREA
SITE PLAN DETAIL-SCALE 1/8" 1'-0" SITE PLAN -SCALE=1/32"=1'-0" PITCH AZIM AZIM (SOFT)
AR-01 25° 318' 332' 235 3
'- iI01/ AR-02 25' 138' 152' 372.6
O4-
O
c• ) _/I --(E)GATE
�044 '- -(E)RESIDENCE
(N)ARRAY AR-01 - #4N
.
���� R (E)DETACHE
STRUCTURE D
(N)ARRAY AR-02 g �;#4##
44## ,
(E)FENCEXI, 4••
(E)DETACHED-
#### 4:#
STRUCTURE
U /, ///
1n(sE sunrun
INV PM / #180120
800 MYLES STAMDISH SLVD,TAUNTON,MA.03730T331
SNP*0
FAX 0
CUSTOMER RESIDENCE:
ELAINE MALCOLM
32 TOWN BROOK RD,
YARMOUTH,MA,02673
TEL.(774)368-3786
APN:YARM-000037-000086
PROJECT NUMBER:
223R-032MALC
DESIGNER: (415)580-6920 ex3
MOHD TARIK
SHEET
SITE PLAN
REV'A 10/6/2022
PAGE PV-2.O
° .-•
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION - DESIGN CRITERIA
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:•3 PSF
Span Sparing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-7" 16" COMP,SEE DETAIL SNR-DC-00436 -1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN EMBEDMENT
AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-9" 16" COMP,SEE DETAIL SNR-DC-00436 2'-0" STAGGERED STRUCTURAL NOTES:L
—• INSTALLERS SHALL NOTIFY
D1-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL
AZIM:318° STRUCTURAL ISSUES
PITCH:25° OBSERVED PRIOR TO
PROCEEDING W/
6" II
23.3" 19'-1" • IF ARRAY(EOXCLUDING SKIRT)
i IS WITHIN 12"BOUNDARY
1'-6" REGION OF ANY ROOF PLANE
-• - EDGES(EXCEPT VALLEYS),
THEN ATTACHMENTS NEED
TO BE ADDED AND OVERHANG
_ � REDUCED WITHIN THE iii
12"
10'-4" BOUNDARY REGION ONLY AS
••FOLLOWS:
ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
D2-AR-02-SCALE:1/8"=1'-0"
AZIM: sunrun
PITCH:25°
6" ;1 40,_8„ r ),1,_8„
#180120
1'-6„ ------ I
❑ ❑ 0 ❑ 0 0 0 0 0 I "v,MYIEs sr osH e[vo r1LWION.MA.02730 7331
„moo
1 o
I ❑ ❑ a ❑ ❑ n n s ❑ . o ❑ 0 8-5 CUSTOMER RESIDENCE:
10'-4" ELAINE MALCOLM
id
❑ ❑ ❑ 7, e ❑ ❑ a o---- 32 TOWN BROOK RD,
t I YARMOUTH,MA,02673
•
STRUCT :•.
. c n �� ❑ ❑ o ❑ r__ ONL `tN OF Mq TEL.(774)368-3786
1-2 oP�� Ss4cb APN:YARM-000037-000086
F4' VINCENT ��, PROJECT NUMBER:
-- -._-----_..--17-5"............. ...............1..-._.6,-4„-- ------__17'-5' •--------._.._. V-3" g MWUMVANEZA 223R-032MALC
N'CIVIL 2
}__.. .......__-__ _.. _.._..... ........._.. 41,_1„....- ..._._._..- ___.___......- ................, 'a,: Ea �e DESIGNER: (415)580-6920 ex3
� ONAEEO,°\ MORD TARIK
SHEET
LAYOUT
REV:A 10/6/2022
SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0
I
J
120/240 VAC
SINGLE PHASE
SERVICE
® METER#: NOTE:TOTAL PV BACKFEED=40A
EVERSOURCE 2205863 USED FOR INTERCONNECTION
UTILITY CALCULATIONS
GRID 1
SUPPLY SIDE TAP
fo,..
(N)LOCKABLE
I EXISTING 100A BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES:
MAIN BREAKER FUSED AC UTILITY
I DISCONNECT REVENUE SE7600H-USSN
7600 WATT INVERTER JUNCTION BOX PV MODULES
.','3)) ;(3! 2 OR EQUIVALENT (i) LONGI GREEN ENERGY TECHNOLOGY
EXISTING + // CO LTD:LR4-6OHPB-355M
100A MAIN ��, �I _ ��i 1 1 _h)/ (31)MODULES
�� PANEL J -- y� OPTIMIZERS WIRED IN:
FACILITY 40A FUSES I ` I (1)SERIES OF(16)OPTIMIZERS
LOADSG o°No SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(15)OPTIMIZERS
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401
120/24OVAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n r u n
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2W
NONE (1)10 AWG THHN/THN-2
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
696 MULES STANDISH Bow,TAUNTON,MA,Onenrui
PHONED
FAX 0
CUSTOMER RESIDENCE:
ELAINE MALCOLM
32 TOWN BROOK RD,
YARMOUTH,MA,02673
MODULE CHARACTERISTICS TEL.(774)368-3786
P401 OPTIMIZER CHARACTERISTICS:
LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000037-000086
TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-032MALC
OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC
MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-6920 ex3
SHORT CIRCUIT CURRENT: 11.25 A MOND TARIK
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 11005 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 16 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 400 V
MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 10/6/2022
SYSTEM OPERATING CURRENT: 27.51 A
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
AWARNING INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
ELECTRICAL SHOCK HAZARD
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
•SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
LABEL LOCATION: •
SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
INVERTER(S),AC/DC DISCONNECT(S),
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
AWARNING POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012:
SYSTEM 605.11.1.4
LABEL LOCATION: CAUTION •
UTILITY SERVICE METER AND MAIN
SERVICE PANEL. II,
PER CODE(S):NEC 2020:705.12(C)
AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF
DO NOT RELOCATE THIS ' ,
OVERCURRENT DEVICE LABEL LOCATION:
INSTALLED WITHIN 3'OF RAPID SHUT DOWN
AL LOCATION:
SWITCHillil
012, PER COWS):201:NEC 2020:890.58(C)(2),IFC s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 III
OCPD(IF APPLICABLE).
PER CODE(S):NEC 2020: 4,, III
705.12(B)(3)(2) ,
I WARNIN SOLAR PV SYSTEM EQUIPPED #180120
PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN ,,, SOS PHONE0ss.,�IsH�Vo.., �.w"02'"0""
COMBINER PANEL ," PNor+eO
FAX 0
DO NOT ADD LOADS III CUSTOMER RESIDENCE
ELAINE MALCOLM
LABEL LOCATION: 32 TOWN BROOK RD,
PHOTOVOLTAIC AC COMBINER(IF MAIN PANEL I NT YARMOUTH,MA,02673
PERCOE(S APPLICABLE). 'j'. TURN RAPID SHUTDOWN J —INVERTER (EXT)
PER CODE(S):NEC 2020:705.12(0)(2)(3)(c) SWITCH TO TH TEL.(774)366-3766
POSITION TO SHUT DOWN
DOWN•• SERVICE ENTRANCE
w•••g= PRODUCTION METER APN:VARM-000037-000066
PV SYSTEM AND REDUCE
PROJECT NUMBER:
PV SYSTEM DISCONNECT
MAXIMUM AC OPERATING CURRENT:31.67 AMPS SHOCK HAZARD IN THE M
FUSED AC— 223R-032MALC
NOMINAL OPERATING AC VOLTAGE 240 VAC ARRAY.
DISCONNECT
DESIGNER: (415)580-6920 ex3
LABEL LOCATION: 32 TOWN BROOK RD, YARMOUTH, MA, 02673 MOHD TARIK
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: S: SHEET
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE ()NEC 2020:705.10,710.10 S I G NAG E
PER CODE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 10/6/2022
PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0
,I