Loading...
HomeMy WebLinkAboutBLDE-23-003231 /q/ Commonwealth of Official Use Only E Massachusetts Permit No. BLDE-23-003231 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked l[Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/12/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 108 BLUE ROCK RD Owner or Tenant RODRIGUEZ ALICIA A Telephone No. Owner's Address 108 BLUE ROCK RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (14 Panels 5.460 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total : Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner ❑ owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 � � � ( ( 23 ( O E C V .. 1 E, . 1. lt�Z //// �i lf� Official Use Only ommonwea o aieac uie , 23 -3 2� G. t c� �7 Permit No. ht �Vto, ' 2e arlmenl,, re Jervieei cl Occupancy and Fee Checked i- : 'ARD OF FIRE PREVENTION REGULATIONS [Rev. 1/071 L,- -.fl►� EN (leave blank) BUILDIN®9e - _ ay - F_ - ATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE.ALL INFORMATION) Date: 12/07/2022 City or Town of: Yarmouth MA 02664 To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 108 Blue Rock Rd Owner or Tenant Alicia Rodriguez Telephone No. (774)268-1236 Owner's Address 108 Blue Rock Rd Yarmouth MA 02664 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service Amps / Volts Os crht ad n Undgrd❑ No.of Meters New Service Amps / Volts Os et-head n Undgrd❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of an interconnected PV system including 14 panels at 5.460 Kw DC Completion of the following table may be waived by the Inspector ql T t 7 , Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Abov.e ❑ In- 0 No of> Unrgency Lighting Qrnd Qrnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones f No.of Switches No.of Gas Burners N��• Initiatinggon Deten and In Devices No.of Ranges No.of Air Cond. Total Tun, No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW 1„cal❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW. No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications quiet : No.of Devices or Equivalent OTHER:Roof Mounted Solar Panels Attach additional detail if desired,or as required by the inspector of Wires. Estimated Value of Electrical Work: $7453 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER 0 (Specify:) I certify,under the pains and penalties of perjuiy,that the information on this application is trite and complete. FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature /1 LIC.NO.:21136 A (If applicable,enter"exempt"in the license number lino Bus.Tel.No.:978594-3519 Address: 695 Myles Standish Blvd. Taunton,MA 02780 Alt.Tel.No.:978 793-7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: S SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION 1 •SYSTEM SIZE:5460W DC.3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRCIIBC11EBC), SERVICE ENTRANCE •MODULES:(14)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION PV-1.0 COVER SHEET L J •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SP SUB-PANEL •NEW 100AMP MAIN BREAKER KIT TO BE INSTALLED. •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). AC AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC DC DISCONNECTS) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(13)(2). ABBREVIATIONS r 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC A CURRENT s u n r u n AFC ARCRC FAULT GRWRINTERUPTER �� CHIMNEY ADM ALMUTH COMP COMPOSITION DC DIRECT CURRENT L] ATTIC VENT #180120 (E) EXISTING [ FLUSH ATTIC VENT VICINITY MAP 4M6 Rrles srNwMaN IRw.TAImroN.IAA annm+ ERR ENERGY STORAGE SYSTEM a PVC PIPE VENT PHONED FAO EXT EXTERIOR 0 METAL PIPE VENT r a.• - CUSTOMER RESIDENCE: INT INTERIOR ALICIA RODRIGUEZ MSP MAIN SERVICE PANEL T-VENT 108 BLUE ROCK RD, (N) NEW CP SATELLITE DISH "-' YARMOUTH,MA,02664 NTS NOT TO SCALE Cle,t,. _ TEL.(774)268-1236 OC ON CENTER -- �� FIRE SETBACKS - APN:YARM-000111-000017 PREFAB PREFABRICATED 1� Bamstao.e - PROJECT NUMBER: PSP POUNDS PER SQUARE FOOT HARDSCAPE (FI .,. ,. 223R-108RODR PV PHOTOVOLTAIC � •• ' • DESIGNER' (415)580.6920 eX3 RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE -:;} SUMAIRKHAN --SOLAR MODULES TL TRANSFORMERLESS SCALE NTS TIP TYPICAL Ia� - SHEET V VOLTS REV NAME DATE COMMENTS COVER SHEET ——a W WATTS L�MI D REV:Al 12/3/2022 LAN LANDSCAPE 1 SNR MOUNT PAGE PV-1•0 POE PORTRAIT SNR MOUNT 8 SKIRT _ nmp.n.sat4AM • SITE PLAN-SCALE=3/32"=1'-0" SITE PLAN DETAIL-SCALE=1/128"=1'-0" (E)RESIDENCE (E)RESIDENCE PlC_ Ap ( „ /�- BLUE ROCK RD • grr _(N)ARRAY AR-Ot sunrun #1120 NGI ESST.NO.1.wTAUM...wa--1m,v, PHOW a FNIO 181 CUSTOMER RESIDENCE ALICIA RODRIGUEZ 108 BLUE ROCK RD, YARMOUTH,MA,02884 AC 11=INV PM -' TEL.(774)268-1238 ARRAY TRUE MAG PV AREA APN-.YARM-000111-000017 PITCH AZIM AZIM (SOFT) PROJECT NUMBER: AR-01 21" 91° 105° 289.7 223R-108RODR DESIGNER: (415)580.8920 ex3 SUMAIR KHAN SHEET SITE PLAN REV:Al 12/3/2022 PAGE PV-2.O Tam**e tai*o"40BO ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Y re Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 12'-6" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" NA NA STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW D1-AR-01-SCALE:1/4"=V-0" 5/16".2.5"MIN.EMBEDMENT AZIM:91° PITCH:21° 2,..2" -8" �- 0 --- --fl - 0 ❑ - ❑ 0 0 .—. - 0._......._ 0 L.-� 5'-4"TYP 10 11" D ❑ C ❑ -..- $ 0 - 0 0 _ v-10" sunrun ____., #180120 Tre,ae"BLVD.TAW..w.ua g/. FAX 0 CUSTOMER RESIDENCE: ALICIA RODRIGUEZ 108 BLUE ROCK RD, STRU YARMOUTH,MA,02664 oNL •1a eF INSTALLERS SHALL NOTIFY ENGINEER OF ANY -@ '`+icy POTENTIAL STRUCTURAL ISSUES OBSERVED TEL(774)268-1236 4 VINCENT max, PRIOR TO PROCEEDING W/INSTALLATION. APN.YARM-000111-000017 0 MWUMVANEZA m CIVIL 'IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" PROJECT NUMBER: BOUNDARY REGION OF ANY ROOF PLANE 223R-108RODR EO�rfe Signed 12/06/2022 EDGES(EXCEPT VALLEYS),THEN ONxI.tv'" ATTACHMENTS NEED TO BE ADDED AND DESIGNER: (415)580-8920 ex3 OVERHANG REDUCED WITHIN THE 12" SUMAIR KHAN BOUNDARY REGION ONLY AS FOLLOWS: SHEET "ALLOWABLE ATTACHMENT SPACING LAYOUT INDICATED ON PLANS TO BE REDUCED BY 50%. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE REV Al 12/3/2022 SEE SITE PLAN FOR NORTH ARROW. ATTACHMENT SPACING INDICATED ON PLANS. PAGE PV-3.0 remitde,.,mn_4.nec . 120/240 VAC SINGLE PHASE SERVICE . METER#: < O EVERSOURCE 2376119 UTILITY GRID 1 EXISTING 100A MAIN BREAKER DISCONNECT WITH 100A MAIN 1 ENCLOSURE /- LOAD SIDE TAP (N)LOCKABLE (1 NEW 100A BLADE TYPE (N)MA SMART MAIN FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: 1 BREAKER DISCONNECT METERVUE SE3800H-USMN ClJ 3800 WATT INVERTER JUNCTION BOX PV MODULES �� EXISTING 9 7 p OR EQUIVALENT n TRINA SOLAR:TSM-39ODE09C.07 _ 125A MAIN AA f `� // (14)MODULES �� PANEL —+ `�. O `.� __I__. *(�/ OPTIMIZERS WIRED IN: FACILITY — 20A FUSES I T I (II SERIES OF(14)OPTIMIZERS LOADS -Law SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT D221NR6 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS 3R.30A UTILITY SOE OF CIRCUIT COMPLIANT S440 I20240VAC CONNECTS TO TOP LUGS- LEE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER s u n r u n 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 693 W 1fS STAND S..Y W.128I117p1..02/80: FM 0 CUSTOMER RESIDENCE ALICIA RODRIGUEZ 108 BLUE ROCK RD, YARMOUTH,MA,02664 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(774)268-1236 TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE 8 VDC APN:YARM-000111-000017 OPEN CIRCUIT VOLTAGE: 40.8 V -- MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE 33.8 V MAX INPUT ISC: 14.5 ADC 223R-108RODR SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC DESIGNER (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUMAIR KHAN SYSTEM SIZE. 5460 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 14.37 A REV:Al 12/3/2022 SYSTEM SHORT CIRCUIT CURRENT 15 A PAGE PV-4.0 Tomplals_vssim_4.0.9e WARNING INVERTER 1 NOTES AND SPECIFICATIONS •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(8),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: m VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS.COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S1 •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S).NEC 2020.690.53 INVOLVED. LABEL LOCATION. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020 890.13(B) WARNING: PHOTOVOLTAIC nWARNIN POWER SOURCE LABEL LOCATION- DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT. SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020,69031(0)(2),IFC 2012- SYSTEM 605.111.4 CAUTION ■ LABEL LOCATION: UTILITY SERVICE METER AND MAIN ■ SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) fWARNIN RAPID SHUTDOWNSWITC; MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM, //_�` DO NOT RELOCATE THIS --- OVERCURRENT DEVICE LABEL LOCATION ' • INSTALLED WITHIN OF PID SHUT DOWN s u n r u n LABEL LOCATION: SWITCH PER CODE(S),NEC 202020 890.58(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012,605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). ----( PER CODE(S),NEC 2020 a., 705.12(B)(3)(2) I WARN1) SOLAR PV SYSTEM EQUIPPED Hi SOLAR PANELS #1801zo PHOTOVOLTAIC SYSTEM �OUEO ON ROOF COMBINER PANEL WITH RAPID SHUTDOWN _ FAX n.sr.,101.KM.,w..,.w,ox,m,», DO NOT ADD LOADS -- CUSTOMER RESIDENCE: LABEL LOCATION: ALICIA RODRIGUEZ 108 INVERTER (EXT) YARMOEROCK RD, ,MA,02 PHOTOVOLTAIC AC COMBINER(IF YARMOUTH,MA,02664 PER CODE(S):NEC 202070512(0)(2)(3)(c) TURN RAPID SHUTDOWN PV PRODUCTION METER SWITCH TO THE"OFF- , AC DISCONNECT TEL.(774)268-1236 POSTTTON TO SHUT DOWN APN:YARM-000111-000017 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE SERVICE ENTRANCE PROJECT NUMBER: IIIIMAXIMUM AC OPERATING CURRENT.16.00 AMPS SHOCK HAZARD IN THE 223R-706RODR NOMINAL OPERATING AC VOLTAGE. 240 VAC ARRAY. AMAIN PANEL(INT) DESIGNER (415)580-6920 ex3 LABEL LOCATION. 108 BLUE ROCK RD, YARMOUTH, MA, 02664 SUMAIR KHAN AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF —- INTERCONNECTION. SHEET PER CODE(S):NEC 2020 690.54 LABEL LOCATION. PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:Al 12/32022 PER CODE(S).NEC 2020:690.56(C) PAGE PV-5.0