HomeMy WebLinkAboutBLDE-23-003278 av-. Commonwealth of Official Use Only
��. 4\ Massachusetts Permit No. BLDE-23-003278
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/13/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 104 PHYLLIS DR
Owner or Tenant COLLINS ROBERT D Telephone No.
Owner's Address COLLINS BARBARA A, 104 PHYLLIS DRIVE, SOUTH YARMOUTH, MA 02664-1644
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(11 Panels 4.290 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
,Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
,Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement. I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
tr10( 3 Eg
RECEIVED
ea�o/ amachuasth Official U^e Only
_ _ DEC 12 20Z� � 3-`=a- 7 c7 Perm:Ito:.
c,'M� 1 _ a p, ni o` ire�ervice5
3` q!!L.DING DEPARTMENT Occpay and Fee Checked
e•w= � BOARD OF FIRE "REVENTION REGULATIONS [Rev. (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: la 1 0"i I a
City or Town of: ' rryln -h To the Inspector of Wires:
„Th\(5)
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street& Number) 1 0 Li 0%1 1\ i S Or C^
Owner or Tenant @a%b our a ( Q t l i ( S Telephone No. SCA 0104,
rOwner's Address Sla inn 0 _ -e 5--}J&
Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box)
E Purpose of Building Utility
^� 'D,1 Utility Authorization No.
Existing Service 10 U Amps (oC.o /a�t U Volts Overhead TZ Undgrd ElNo.of Meters
New Service Amps / Volts Overhead n Undgrd ElNo.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: 1 11 • 0 (1
oho P Q 1( 1► y . a o w
,i 4sr°
Co pletion off the the followingtable may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
KVA
Transformers
icib
No.of Luminaire Outlets No.of Hot Tubs Generators KV.%.
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units _
C) No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
of
No.of Switches No.of Gas Burners No. Initiatinnggon Dete and
In Devices
No.of Ranges No.of Air Cond. l Tons No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection ❑ Other
J No.of Dryers Heating Appliances KW Security Systems:*
tT No.of Devices or Equivalent
No.of Water KM, No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring:
Y g No.of Devices or Equivalent
OTHER:
a Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: 58 6 6 . o O (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al
Licensee: Nathan Ashe Signature 1�. LIC.NO.:21136A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519
QAddress: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. I PERMIT FEE: $
•
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE# DESCRIPTION •SYSTEM SIZE 4290W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
1
PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(11)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS.
PV-2.0 SITE PLAN SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,
PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
PV-4.0 ELECTRICAL
SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL oj'�` of 44sMOVA 4,,,
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). c e°' CNIL cy ^,
0 (AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). I" N07.56313 '^
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 'Oqo,* sTCA4`"e
0 DC DISCONNECT(S) FSsioNA1.E,
•13.35 AMPS MODULE SHORT CIRCUIT CURRENT.
Exp:6/30/2024
CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. STAMPED 12i032022
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
ABBREVIATIONS r 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
A AMPERE
L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT s u n r u n
AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT #180120
IEI EXISTING FLUSH ATTIC VENT VICINITY MAP MS YYLEs GYXGXISN BAO.TAUNtON,NA,onao7n1
ESS ENERGY STORAGE SYSTEM PVC PIPE VENT Dennis PI-NEO
(`,4l
EXT EXTERIOR
METAL PIPE VENT CUSTOMER RESIDENCE:
INT INTERIOR 1' 41 BARBARA COLLINS
MSP MAIN SERVICE PANEL T-VENT — 104 PHYLLIS DR,YARMOUTH,
(N) NEW Yarmouth MA,02664
SATELLITE DISH
NTS NOT TO SCALE �"5 ('�{�104 Phyllis D�,
OC ON CENTER TEL.(508)694-6916
FIRE SETBACKS f i••y) APN:YARM-000078-000030
PRE-FAB PRE-FABRICATED l.(� I?Ll YarMO�Jt�1, MA — PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT HARDSCAPE J JI-arV IC 223R-104COLL
PV PHOTOVOLTAIC '"'`'1 DESIGNER: (415)580-6920 ex3
RSD RAPID SHUTDOWN DEVICE —PL- PROPERTY LINE ANUP SHARMA
TL TRANSFORMERLESS - SOLAR MODULES -
SCALE:NTS •''.1 SHEET
TYP TYPICAL _ N REV NAME DATE COMMENTS COVER SHEET
✓ VOLTS
W WATTS Q REV:A 12/7/2022
LAN LANDSCAPE -- o .- O
-- SNR MOUNT PAGE PV-1.0
POR PORTRAIT SNR MOUNT&SKIRT
T.mpl.M_vs on_A 087
I
E
SITE PLAN-SCALE=1/16"•1%0"
Z
® P I=
Pt
Q PL
P
PM INV
...--.......--.......7
Pt
a4 .
SN OFMA.c_
� (N)ARRAY AR-Ot o.�+��MovAss9 cy
a 4'• ./ , .. ... .. .
4 ��eP py aN
c CIVIL ^�
. N0.56313
,! a• (E)RESIDENCE a. — N
4,
➢O �EOISTERf'��t�'e
Ffss/ONALEO.
a.. Ezp:6/30/2024
n STAMPED 12/03/2022
41 'I /
r
.
i . . • A. - A sunrun
r- e
A #180120
695 MYlE3 STNJg6M BLVD.TIUMON,MA,03]86]331
CUSTOMER RESIDENCE:
BARBARA COLLINS
104 PHYLLIS DR,YARMOUTH,
MA,02664
PL
PL -- TEL(508)694-6916
PL ARRAY TRUE MAG PV AREA APN:YARM-000078-000030
L_____ — PITCH AZIM AZIM (SOFT)Pl PROJECT NUMBER.
AR-01 27° 278° 292° 227.6 223R-104COLL
Pl
DESIGNER: (415)580-6920 ex3
ANUP SHARMA
SHEET
SITE PLAN
REV:A 12/7/2022
PAGE PV-2.0
Tempate_w n_e 087
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF
Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
12'- RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 0„ 16" STAGGERED 141 MPH 3-SEC GUST.
COMP,SEE DETAIL SNR-DC-00436
S.S.LAG SCREW
5/16".2.5"MIN.EMBEDMENT
D1-AR-01-SCALE:3/16"=1'-0"
AZIM:278°
PITCH:27°
10'-1" a 34'-10" 4'-5"
•
•
•
•
4'-1.
•
•
❑ [J C 0 0 ❑ ❑ ❑ • ;0. OF,N4S
iMOVASS9�OyG�� clva yN�
N0.56313
7 3" ❑ 0 41 0 ►❑ ® 13 :
_5'-4'�TYP. 4',o„AECIST ie
FSS/ONALEG`�
0 0 0
Exp.6/30/2024
STAMPED 12/03/2022
5'-5"
sunrun
INSTALLERS SHALL NOTIFY ENGINEER OF #180120
ANY POTENTIAL STRUCTURAL ISSUES en MYLES STAND.BLVD.TAUNT.,,MA.vnaaTOr
OBSERVED PRIOR TO PROCEEDING W/ '"OpE0
INSTALLATION.
•IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" CUSTOMER RESIDENCE:
BOUNDARY REGION OF ANY ROOF PLANE BARBARA COLLINS
EDGES(EXCEPT VALLEYS),THEN 104 PHYLLIS DR,YARMOUTH,
ATTACHMENTS NEED TO BE ADDED AND MA,02664
OVERHANG REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS FOLLOWS: TEL.(508)694-8916
"ALLOWABLE ATTACHMENT SPACING APN:YARM-000078-000030
INDICATED ON PLANS TO BE REDUCED BY PROJECT NUMBER:
50%. 223R-104COLL
ALLOWABLE OVERHANG INDICATED ON
PLANS TO BE 1/5TH OF ALLOWABLE DESIGNER: (415)580-6920 ex3
ATTACHMENT SPACING INDICATED ON PLANS. ANUP SHARMA
SHEET
LAYOUT
REV:A 12/7/2022
SEE SITE PLAN FOR NORTH ARROW
PAGE PV-3.0
T.mp.t._Wrsion_4.0.87
I
i
120/240 VAC
SINGLE PHASE
SERVICE
M O METER#:
EVERSOURCE 7158969
UTILITY
GRID NOTE:TOTAL PV BACKFEED=20A
USED FOR INTERCONNECTION
1 EXISTING CALCULATIONS
C
1 100A MAIN
BREAKER
EXI
y 100ATING (N)MA SMART
�� MAIN (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES:
FACILITY PANEL BLADE TYPE REVENUE SE3800H-USMN
AC DISCONNECT METER 3800 WATT INVERTER JUNCTION BOX PV MODULES
LOADS 3 T
b T OR EQUIVALENT ((:�) TRINA SOLAR:TSM-390DE09C.07
D�� O I ../` �y� I + // (11)MODULES
OPTIMIZERS WIRED IN:
(1)SERIES OF(11)OPTIMIZERS
I I
(N)20A °ROUND SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT
PV BREAKER AT DU221RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT S440
OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE $u n ru n
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (2)10AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 #180120
3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHWTHWN-2 B.MYLESSTANDISH BLVD,TAUNTON,MA,O7OO.7i31
PHONE
FAX 0
CUSTOMER RESIDENCE:
BARBARA COLLINS
104 PHYLLIS DR,YARMOUTH,
MA,02664
MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS:
TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC TEL.(508)694-6916
OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC APN:YARM-000078-000030
MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC
SHORT CIRCUIT CURRENT 13.35 A PROJECT
MAX OUTPUT CURRENT: 15 ADC 223R- NOLL
UMBER:
SYSTEM CHARACTERISTICS-INVERTER 1 DESIGNER: (415)580-8920 ex3
SYSTEM SIZE: 4290 W ANUP SHARMA
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V
SYSTEM OPERATING VOLTAGE: 380 V SHEET
MAX ALLOWABLE DC VOLTAGE: 480 V ELECTRICAL
SYSTEM OPERATING CURRENT: 1129 A
SYSTEM SHORT CIRCUIT CURRENT: 15 A REV:A 12/7/2022
PAGE PV-4.0
Temps re_verson_J.0.87
/\WARN ING INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR
ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS,COLORS AND SYMBOLS.
TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION. METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:890.53 INVOLVED.
•SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
LABEL LOCATION: SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
INVERTER(S),AC/DC DISCONNECT(S), •DO NOT COVER EXISTING MANUFACTURER LABELS.
AC COMBINER PANEL(IF APPLICABLE).
PER CODE(S):NEC 2020:890.13(B)
IFININIFPHOTOVOLTAIC
AWARNING POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:890.31(D)(2),IFC 2012:
SYSTEM 605.11.1.4
CAUTION .
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL. 111
PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH
AWARNING MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM N
DO NOT RELOCATE THIS /N,
OVERCURRENT DEVICE LABEL LOCATION: i
INSTALLED WITHIN 3'OF RAPID SHUT DOWN
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1.IFC 2018:1204.5.3
OCPD(IF APPLICABLE).
PER CODE(S):NEC 2020.
705-12(B)(3)(2)
AWARNING SOLAR PV SYSTEM EQUIPPED -SOLAR PANELS ON ROOF #180120
n.MYLES STANDISH BLVD,TAUNTON,MA,027961131
PHOTOVOLTAIC SYSTEM COMBINER PANEL "%WITH RAPID SHUTDOWN •..
DO NOT ADD LOADS CUSTOMER RESIDENCE:
BARBARA COLLINS
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER(IF 104 PHYLLIS DR,YARMOUTH,
APPLICABLE). MAIN PANEL AND PV MA,02664
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN BREAKER DISCONNECT
SWITCH TO THE"OFF" LrpALs INVERTER (EXT)� TEL.(508)694-8916
POSITION TO SHUT DOWN APN:YARN-000078-000030
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE SERVICE ENTRANCE PROJECT NUMBER:
SHOCK HAZARD IN THE PV PRODUCTION—
ARRAY. ME METER 223R-104COLL
MAXIMUM AC OPERATING CURRENT:15_83 AMPS -AC DISCONNECT
NOMINAL OPERATING AC VOLTAGE: 240 VAC
DESIGNER: (415)580 6920 ex3
LABEL LOCATION: 104 PHYLLIS DR, YARMOUTH, MA, 02664 ANUP SHARMA
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. - SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 S I G NAGE
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 12/7/2022
PER CODE(S):NEC 2020:890.58(C)
PAGE PV-5.0