Loading...
HomeMy WebLinkAboutRevised Plan 6.14.2024PROP. MIN. ELEV. 15.0' NAVD88_ FOR LOWEST HORIZ. MEMBER PILING FOUNDATION DESIGN BY OTHERS *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM INSULATE PIPE WHERE ABOVE GRADE REMOTE BLOWER LOCATION PER OWNER 6" INSPECTION PORT/VENT PROP. 3" VENT PIPING MINIMUM .75' OF COVER OVER PRECAST 5.6' �o 4" PVC PIPE INSPECTION/PUMP- OUT PORTS I I I 1 I 11 \3.0'tIt SYSTEM PROFILE (NOT TO SCALE) ALL SYSTEM COMPONENTS SHALL BE PROVIDE MIN. 20" DIAM. WATERTIGHT MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PROVIDE INSPECTION PORT TO GRADE r 4" VENT, PERF. 2% SLOPE REQUIRED OVER SYSTEM RUNS OVER 2" DRILL LAST HOLE IN EACH FEMALE ADAPTOR & THREADED PLUG 5. 0' LATERAL ON TOP TO VENT 2 0"0 HR D D END CONNECTION MINIMUM .75' OF COVER OVER PRECAST 6 10' --]AIR WHILE LATERAL FILLS SCH 40 PVC TREATED WATER OUTLET WATERPROOF 1 BOOTS I (TYP) 2.25' --- -- - WASTE INLET (MIN. 10" # oti 2.00' 3" ABOVE OUTLET) TEE 50" WATERPROOF TANKS WATERPROOF/WATERTIGHT Boors (TYP) 000, 0 0°00o°o0co0o0o°00°o°o°co°o°o°o°o°o°o°o°c oaoa °g000g0000��o�a�o�o08�0�0�0� I ono-000000000�000c „O nOn°non0n°noonOn°n°nOn°nonOnO.. n°n°n°..O..on°n°nOn� 6" DIAM. HOLE 0.5 MICROFAST WITHIN \ H-20 F.A.S.T. CHAMBER INTERNAL MOUNT (2.5 % SLOPE MIN.) ( 2 % SLOPE) FOUNDATION 22' F.A.S.T. TANK 2' - VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') (1 h): REDUCTION IN GROUNDWATER SEPARATION, 5' TO 3' (WITH MICROFAST) (1 j): REDUCTION SEPARATION BETWEEN INLET/OUTLET TEES AND HIGH GROUNDWATER UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7): REDUCTION IN SETBACK, SAS TO TCB (100' TO 77.1') VARIANCE OF 1' REQUESTED FROM LATERAL REMOVAL OF UNSUITABLE MATERIAL Yarmouth Conservation Conditions: 1. A hard copy of the plan shall be provided to the Conservation Administrator for review. An electronic copy of the final plan shall be provided to kgrant@yarmouth.ma.us. 2. The proposed sewage disposal system shall meet the applicable Title 5 wetlands setbacks as set forth by the Health Department. 3. A "work limit" line shall be established with Erosion Controls (i.e straw bales, staked filter fabric, bark mulch, "silt sacks," products made with rice straw, and other weed -free products or approved by the Commission.) Hay bales are not allowed. It is the applicant's responsibility to implement and maintain appropriate and adequate erosion controls measures throughout the construction process. 4. No work of any kind shall occur on the Resource Area side of the work limit line. This line shall be established prior to any construction or work. 5. All imported fill shall be clean and not contain any foreign debris such as cement, bituminous concrete, rubber, metal, trash, boulders, etc. 6. Debris, including litter, shall be picked up immediately. Any excess material that is excavated from the job site shall be disposed of at a location approved by the Conservation Administrator or in a covered dumpster. No debris shall be allowed in a Wetland or Waterway. 7. Washing of equipment/tools shall be done OFF -SITE or handled in a manner approved by the Conservation Administrator. 8. No equipment shall be refueled, nor shall fuel be stored within 100 feet of a resource area. 9. The cesspool is to be pumped dry, the connection broken, and filled with clean sand. 10.Any area that is disturbed during construction shall be revegetated immediately or as soon after as the growing season commences. Permanent stabilization shall be carried out in order to minimize erosion. TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BARRY LEWIS DATE: 1 1-30-2023 PERC. RATE _ < 2 MIN/INCH CLASS,__ 1_ SOILS 4 ELEV. 0" 1 5, 30" 38" FI LL S 1OYR 3/1 MS GLEY 1 6/10Y 48" 1, C MS 1OYR 4/6 108" -4' GROUNDWATER ENCOUNTERED AT 56" EL. 0.33 LICE ##23-218 y P �Q �AV o_67 - O �,0A�r Z5 cj PROPOSED 1000 GAL. H-20 PUMP CHAMBER (SEE DETAIL) _ 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21} PUMP CHAMBER BUOYANCY CALC: MICROFAST H-20 TANK WEIGHT: 27,000 LBS 11.5' x 6' x 4.1' x 62.4 = 17,653 UP (OK) 1000 GAL PUMP CHAMBER H-20 TANK WEIGHT: 17,250 LBS 9' x 5.25' x 4.45' x 62.4 = 13,121 UP (OK) 4k SYSTEM DESIGN: 1/4" SHIELDED 5.30' ORIFICES I NV. 5.10' = i 2" SCH 40 PVC - -- - - �� 009 -- --- ��00 � �--- �� 4 1:10- - 4.60' S = 0.005 SLOPE BACK 2" INVERTS LEVEL AT 5.10' z TO PUMP CHAMBER 2" PRESSURE LINE a BOTTOM LEACHING LEVEL AT EL. 4.60' a 2" CENTRAL FED MANIFOLD o PITCH TO DRAIN BACK TO CONNECT ENDS PUMP CHAMBER- NO LOW SPOTS. 3 w _J Z 3/4" TO 1 1/2" DOUBLE WASHED STONE SIDE ELEVATION VIEW HIGH G-W EL. 1.6' (TIDALLY INFLUENCED) 25' \ 50,OF`er OFFSET LEACHING FACILITY 0 BENCHMARK: MAG NAIL = 4.8' NAVD88 o 4' REMOVAL OF UNSUITABLE SOIL REQUIRED i• � AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE / WITH CLEAN MED. SAND, TO MEET Iro SPECIFICATIONS OF 310 CMR 15.255(3) / PROP. Y FENCE 0�� yot NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST C UNITS TO BE AASHO H-( 5. PIPE JOINTS TO BE MADE WATERTIGHT. o m 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE LO WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOR SHALL BE RESPONSIBLE FOR 9�P Locus Lewis ` Bay ` CALLING DIGSAFE (811) AND VERIFYING THE LOCATION LOCUS MAP OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000't 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE ASSESSORS MAP 20 PARCEL 26 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED LOCUS IS WITHIN FEMA FLOOD ZONE VE EL. 13 ON AND REMOVED OR PUMPED AND FILLED WITH CLEAN COMMUNITY PANEL #25001 CO569J DATED 7/16/2014 SAND' (DESIGN FLOOD ELEVATION = 15.0) 13. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. 14. ALL ROOF DRIP LINES SHALL INFILTRATE TO OWNER OF RECORD STONE TRENCHES. 15. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST LISA A DOUGLAS TRUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR 20 WARREN STREET PROPER FILTER INSTALLATION. MEDFORD, MA 02155 16. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. MITIGATION CALCULATIONS: - - - PROPOSED ��°� 280 S.F ~ y GARAGE MITIGATI \� I \ R v PLANTI GS '� �• O PROP.'` .pq �If h, H I j ...,....._.... FENCE iY► F,p CrS FAST BLOWER AND VENT WITH �;X Irk CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT BY CONTRACTOR NP WITH HOMEOWNER CONSULTATION) \ \ �0 V a F FMq F<O ®0 11 \! \ \ � `M\W . \2� c 1` t.1fj I43 XISTING OWELL HEAVILY VEGETATED AREA \ 'yHW �'4 s EXISTING CONDITIONS GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS 0 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 2000 GAL. DUAL COMPARTMENT SEPTIC TANK/ PUMP CHAMBER LEACHING: 330 GPD / (.74) = 446 SF REQUIRED 10' X 45' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 10' X 45' PIPE AND STONE LEACHING FIELD ' FFM qF F<. 12 t<S ZON .01 F �F F 13 PROVIDE 135' OF 40 MIL LINER AT 4' OFF SAS IN AREA SHOWN. TOP AT ELEV. 5.4% bOTTTOM AT EL. 2.9'f r ` S0, O f F\ET F�t \ \ +3. A �,,�, g 3g• OF yy \ LOB RA ��? EXIST. �^� I^� \ F.'J 3.4LAWN �v v v _ STAKED SILT FENCE WORK HEAVILY VEGETATED AREA \\ LIMIT LINE Iflyw of F 1.6' FEMALE ADS SC ( PROP. WATERTIGHT COVER TO GRADE ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE PROVIDE QUICK DISCONNECT FOR PUMP BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP TANKS WATERPROOF/WATERTIGHT INV. IN 1.90 L NO LOW POINTS WATERPROOF 1000 GAL. H-20 S/ 2" PRESSURE LINE BOOTS (TYP) 330 GAL.+ SLOPE TO DRAIN BACK ALARM ON TEE RESERVE FLOAT SWITCH WEEP HOLES SETTINGS: PUMP ON CHECK VALVE 8„ 5" WORKING RANGE MYERS SRM 4 5" SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) APPROVED DATE BOARD OF HEALTH ' MA o� o000 00o O o 0000 PUMP CHAMBER (NOT TO SCALE) WATERPROOF/WATERTIGHT e PROPOSED CONDITIONS 2"0 SCH40 PVC MANIFOLD FEMALE ADAPTOR & THREADED D PLUG SCH 40 PVC PLAN VIEW PIPING DETAIL ZONING SUMMARY HARDSCAPE 0-50' 50-100' EXISTING: BUILDING 799 SF 792 SF DECK 130 SF 19 SF PATIO/DRIVE 102 SF 250 SF TOTAL: 1031 SF 1061 SF PROPOSED: BUILDING 519 SF 988 SF DECK 163 SF 33 SF PATIO/DRIVE 0 SF 378 SF TOTAL: 682 SF 1399 SF INCREASE: -349 SF 338 SF NET REDUCTION OF 11 SF HARDSCAPE TOTAL APPROXIMATELY 140 SF OF EXISTING VEGETATION TO BE REMOVED ALONG MALFA ROAD MITIGATION PLANTING SCHEDULE SYMBOL PLANT NAME SIZE AMMOPHILABEACH BREVLIGULATA-2800SF HOLE ZONING DISTRICT: R-25 DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 25,000 S.F. 8,835 S.F. 8,835 S.F. MIN. LOT FRONTAGE 150' 105' 105' MIN. FRONT SETBACK 30, 7.4' 31.5' MIN. SIDE SETBACK 15' 23.1' 20.0' MIN. REAR SETBACK 20' 5.2' 6. 0' MAX. BUILDING COVERAGE 25% 19.7% (1740 S.F.) 19.3% (1703 S.F.) MAX. BUILDING HEIGHT 35' 20't 34.9' SITE PLAN OF TO #1 MALFA ROAD MP PIT WEST YARMOUTH MA y PREPARED FOR ANTHONY FEOLA DATE: MARCH 28, 2024 REV.: MAY 29, 2024 (HOUSE FOOTPRINT) REV.: JUNE 11, 2024 (SEPTIC PROFILE) Scale:1 "= 20' �tN OF V,1 OFkASSycyG ��o`'� DANIEL cyG� 0 10 20 30 40 50 FEET o DANIELA. N o U) off 508-362-4541 OJALA GJALA �' 0 Civil'. No.40980 fax 508-362-9880 N0.4650 0 ! o a� downcape.com @ O� FEss\o �� /� r /� 0/ S'tt: � ��4' ���0 S U Rvdown cope a#7 ist ees ing, i�Ic. S�ONAL civil engineers land surveyors 1 939 Main Street ( Rte 6A) 6-,v Ly� YARMOUTHPORT MA 02675 DATE DANIEL A. GJALA, P.E., P.L.S DRAFTED BY: CJF CHECKED BY: fW 23-218