Loading...
HomeMy WebLinkAboutBLDE-23-001469 ' 0 '' Commonwealth of Official Use Only EA1 `, Massachusetts Permit No. BLDE-23-001469 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/20/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 1 ALM IRA RD Owner or Tenant SONJA FELLMAN Telephone No. Owner's Address 1 ALMIRA RD, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (25 Panels 9.125 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number , Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 _� 6 p/i - 11 pit -, t- i R E C ELEDC Commonwealth,o////aiiachu3e Official Use Only ' -_*_ _�l. c� Permit No`av7 (Q i, !, . e artment o� ire�ervices SEP -:vim_- P __�=(_ Occupancy and Fee Checked BUILDING _ MENPARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) PPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: q /1 y / an la City or Town of: ya -MOU4 To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) l Ac rytirO act Owner or Tenant ill Fij(man Telephone No. 5087"](� a Owner's Address , O.2 W1( Is this permit in conjunction with a building permit? ties 1 No (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service [00 Amps I aQ / ay() Volts Overhead ll<I Undgrd No.of Meters 1 New Service Amps / Volts Overhead Undgrd No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: l ncjialictiinin O f an 1 nitrCLyme(*A roc 1-O Q PV au5+e_rrl a5pct.n,1 s 4. 1 a5 li*/ J Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf T Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of Emergency Lighting grnd. hind. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local DI Municipal ❑ Other p Connection No.of Dryers Heating Appliances KW Sec Not of Devi es or Equivalent No.of Water h`�. No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: No. H Y g No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: la Li 5 Ip .p p (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature iii -� LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:9125W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA RESIDENTIAL Code,9th Ed.(2015 ---SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(25)LONG!GREEN ENERGY TECHNOLOGY CO IRC/IBC/IEBC),MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND SE SERVICE ENTRANCE LTD:LR4-60HPH-365M INSTALLATION INSTRUCTIONS. MEI PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.R USSN MP MAIN PANEL PV-3.0 LAYOUT • •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. MEMO PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 ----SNR MOUNT MAIN PANEL REPLACEMENT:EXISTING 125 AMP MAIN PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY 0SUB-PANEL SNR MOUNT 8 SKIRT PV-5.0 SIGNAGE •WITH 100 AMP MAIN BREAKER TO BE REPLACED WITH NEW GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. 125 AMP MAIN PANEL WITH 100 AMP MAIN BREAKER. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). IAC I AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DEBATED CURRENT. DC •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. ^� ^I DC DISCONNECT(S) FIRE SETBACKS •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)8 690.8(b)]. CB IQ COMBINER BOX HARDSCAPE I—J INTERIOR EQUIPMENT —PL— PROPERTY LINE L J SHOWN AS DASHED SCALE NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 w' (E) EXISTING sus MYLES sT,wdsH BLVD.T UNTON,MA 52710.113W - ESS ENERGY STORAGE SYSTEM FPNONEAA 00 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC SONJA FELLMAN MSP MAIN SERVICE PANEL 1 ALMIRA RD,SOUTH y (N) NEW YARMOUTH,MA,02664 NTS NOT TO SCALE • OC ON CENTER TEL.(508)776-2692 PRE-FAB PRE-FABRICATED APN:YARM-000068-000122 PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC PROJECT NUMBER: RSD RAPID SHUTDOWN DEVICE 223R-001FELL TL TRANSFORMERLESS DESIGNER: (415)580 6920 ex3 TYP TYPICAL AMY CYZMAN V VOLTS C W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET ti t� REV:A 9/13/2022 R5 PAGE PV-1.0 ,,c -4 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/18"=1'-0" PITCH AZIM AZIM (SQFT) eilb AR-01 28° 229° 243° 490.2 IT I a. i i K/44IIj :I >)PMINV sunrun (E)RESIDENCE 4' #180120 GO MYLES STANDISH BLVD,TAUNTON.MA,027861331 q PHONED F.0 \ \ CUSTOMER RESIDENCE: SONJA FELLMAN 1 ALMIRA RD,SOUTH e� YARMOUTH,MA,02664 3 \ 77 TEL.(508)776-2692 APROJECTN:YARM-000068-00NUMBER:0122 1 \ P 223R-001FELL / (E)GATE DESIGNER: (415)580 6920 ex3 3 AMY CYZMAN a SHEET SITE PLAN REV:A 9/13/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 16'-4" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREWS: D1-AR-01-SCALE:3/16"=1"-0" 5/16":2.5"MIN EMBEDMENT STRUCTURAL NOTES: AZIM:229° • INSTALLERS SHALL NOTIFY PITCH:28° ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY �# 1'-6" REGION OF ANY ROOF PLANE 2'-5" • 46'-6" • EDGES(EXCEPT VALLEYS), —� THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 2-1' REDUCED WITHIN THE 12" — 0 G— 0 E3 ❑ BOUNDARY REGION ONLY AS F LLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON 0 0 0 0 q 0 ❑ 0 6'-10" PLANS TO BE REDUCED BY { --6'TYP 50% ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 13'-10' 87 - n C B - B B - B B a B n n 1/5TH OF ALLOWABLE ATTACHMENT SPACING 31-8• INDICATED ON PLANS 1 6'-11" __ ❑ ❑ ❑ ❑ 10 ---fl-- C� n 5_g" n n n n sunrun () 3-5" ,. 1 C #180120 y.2'-9"'.,."..".'..—. 17"5"____ 17'-6" __._.._.. ___.. 6.5 MYLES STANDISH BLVD,TAUNTON,MA.00180-1331 PHONE PAS 0 18'-9" CUSTOMER RESIDENCE: SONJA FELLMAN 1 ALMIRA RD,SOUTH YARMOUTH,MA,02664 TEL.(508)776-2692 APN:YARM-000068-000122 STRUCT PROJECT NUMBER: ONL 223R-001 FELL �y1N OFM'lf 04 stge DESIGNER: (415)580-6920 ex3 4' VINCENT m ci MWUMVANUA AMY CYZMAN CIVIL SHEET N. LAYOUT i%('1EPip��e ONAIE��' REV A 9/13/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 .1 _I 120/240 VAC SINGLE PHASE SERVICE M O METER#: EVERSOURCE 2368676 UTILITY GRID 1 NEW 100A NOTE:TOTAL PV BACKFEED=40A 1 MAIN USED FOR INTERCONNECTION BREAKER CALCULATIONS ti^ W 125A (N)MA SMART SOLAREDGE TECHNOLOGIES: — -- MAIN (N)LOCKABLE UTILITY SE7600H-USSN WITH �� PANEL BLADE TYPE REVENUE REVENUE GRADE METERING FACILITY — — 7600 WATT INVERTER JUNCTION BOX AC DISCONNECT METERPV MODULES LOADS 3 3 3 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY _ / CO LTD:LR4-60HPH-365M (25)MODULES ~ �� O .� ~J ±0// OPTIMIZERS WIRED IN: --I I (1)SERIES OF(12)OPTIMIZERS (N)40A GROUND SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(13)OPTIMIZERS PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE - (1)10 AWG THHN/THWN-2 $u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 SBS MYLES STANDISH BLVD,TAUNTON,MA,02700 7991 PHONE 0 FAX 0 CUSTOMER RESIDENCE: SONJA FELLMAN 1 ALMIRA RD,SOUTH YARMOUTH,MA,02664 MODULE CHARACTERISTICS LONGI GREEN ENERGY P401 OPTIMIZER CHARACTERISTICS: TEL.(508)776-2692 TECHNOLOGY CO LTD: MIN INPUT VOLTAGE: 8 VDC APN:YARM-000068-000122 LR4-60HPH-365M: 365 W MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 40.7 V MAX INPUT ISC: 11.75 ADC 223R-001 FELL MAX POWER VOLTAGE: 34.2 V MAX OUTPUT CURRENT: 15 ADC SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 AMY CYZMAN SYSTEM SIZE: 9125 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 13 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 22.81 A REV:A 9/13/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 SITE PLAN-SCALE=1/16"=1'-0" IV d" •e 9'f'O e`' C G • 4pir+4 ///././ 4 44 4000 Aill e`- 4 i 4 i 04 •(N)ARRAY AR-01 •aiks♦♦♦ , F-0-, .g SE I AC I�, (E)RESIDENCE e g 120/240 VAC SINGLE PHASE SERVICE k © METER#. EVERSOURCE 2368676 UTILITY NOTE: TOTAL PV BACKFEED = 40A GRID NEW 125A MAIN USED FOR INTERCONNECTION 1 PANEL CALCULATIONS 100A SUB-PANEL FEEDER BREAKER (N) LOCKABLE • BLADE TYPE (N) MA SMART SOLAREDGE TECHNOLOGIES: UTILITY SE7600H-USSN WITH LOAD FUSED AC REVENUE GRADE METERING SIDE TAP DISCONNECT REVENUE 3 METER 3 7600 WATT INVERTER JUNCTION BOX PV P T 2 OR EQUIVALENT 1 ci----.41=n. (M) s-l-N _7.. --.-----. + ��- EXISTING 40A FUSES l �� 100A SUB SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT \ �� PANEL D222NRB 100A CONTINUOUS WITH AFCI, RAPID SHUTDOWN FACILITY - 3R, 60A UTILITY SIDE OF CIRCUIT COMPLIANT LOADS FACLMY 120/240VAC CONNECTS TO TOP LUGS- ,� :GROWS) (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS , /\WARN I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR i IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VAC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD . WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S), AC/DC DISCONNECT(S), SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC /\WARNING .. ..... POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES: UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: CAUTION • UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER /WARNING el POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEMDO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: / �_ INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2), IFC SUfl r u n AODJ DCEF APPL CABLNT TO PV REAKER AND ESS 2012:605.11.1,IFC 2018: 1204.5.3 SOLAR PANELS E). PER CODE(S):NEC 2020: 4" ON ROOF • 705.12(B)(3)(2) ` /AWARNING SOLAR PV SYSTEM EQUIPPED #180120 695 MYLES STANDISH BLVD,TAUNTON,MA,02780-7331 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN COMBINER PANEL PHONED FAX 0 DO NOT ADD LOADS CUSTOMER RESIDENCE: SONJA FELLMAN LABEL LOCATION: PHOTOVOLTAIC AC COMBINER(IF 1 ALMIRA RD, SOUTH YARMOUTH, MA, 02664 APPLICABLE). 3" TURN RAPID SHUTDOWN PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) SWITCH TO THE"OFF" ,owELECTRIC ANEW MAIN PAN EL(I NT) --AlL TEL.(508)776-2692 POSITION TO SHUT DOWN INVERTER (EXT) APN: YARM-000068-000122 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT: 31.67 AMPS SHOCK HAZARD IN THE SERVICE ENTRANCE - - PRODUCTION 223R-001 FELL 11 NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. , METER - AC DISCONNECT DESIGNER: (415)580-6920 ex3 LOCATION: L°�" °": 1 ALMIRA RD SOUTH YARMOUTH MA AMY CYZMAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF ..• + + + 02664 INTERCONNECTION. • .- SHEET LA PER CODE(S):NEC 2020:690.54 ONBEL OR OCATION:MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 9/13/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0