HomeMy WebLinkAboutBLDE-23-001588 • Commonwealth of Official Use Only
fe% Massachusetts Permit No. BLDE-23-001588
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/26/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 23 HIDDEN ACRES AVE
Owner or Tenant RAQUEL IDROVO Telephone No.
Owner's Address 23 HIDDEN ACRES AVE, WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No ❑ (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(11 Panels 4.016 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
_ Commonwealth o/Ma99achuaettj Official Use Onl
* /
lil+ , Permit No.
�
2epartment o�_7ire Services
ccupancy and Fee Checked
tI BOARD OF FIRE PREVENTION REGULATIONS [Rev.O 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: q I a3 iajzza
City or Town of: a,r m p V.i.h To the Inspector of Wires:
By this application the undersigns gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 60 +Ijdrpn Acrts pat
Owner or Tenant Qpquct idrOvO Telephone No. 5jo8a803i)
Owner's Address 5Q rye a S 4.bdA.
Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service '1 Amps atZ / al..10 Volts Overhead ❑� Undgrd❑ No.of Meters
New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: •Innietlla.ti�r1 Cf an I n-Icr(cnry l4.Lel
rbor- op Pd st S-K-m 11 pa-..ru t\ LLOl 6 w\iJ
Completion of the following table may be waived by the Inspector of Wires.
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
of
No.of Switches No.of Gas Burners No. InDete and
Initiatinnggon Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
g Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
No.of Dryers Heating Appliances KW Security Systems:*
rY No.of Devices or Equivalent
No.of Water KWNo.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.H dromassa a Bathtubs No.of Motors Total HP TelecommunicationsNofDeieorEquivalent
Wiring:
Y g No.of Devices Equiva
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: 51.41 . .0 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al
Licensee: Nathan Ashe Signature w- / LIC.NO.:21136A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519
Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent PERMIT FEE: $
Signature Telephone No.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:4015W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), FM SOLAR MODULES PV-1.0 COVER SHEET
•MODULES:(11)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE 1
LTD:LR4-60HPH-365M INSTRUCTIONS. WI p---_ -o--"_"---gi"------0 PV-2.0 SITE PLAN
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. I 'MP
SE3800H-USMN MAIN PANEL PV-3.0 LAYOUT
-
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. ___ PV-4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436 "SNR MOUNT
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL --- SNR MOUNT&SKIRT PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
Cj CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT CoFm4s.
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT4MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENTS9Cy yGN a•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) e=' METAL PIPE VENT 13CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 1 T-VENTyG-
0 44•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). OAC DISCONNECT(S) �� Nc\�
SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Up:6/30/2024
DC DC DISCONNECT(S)
•11.43 AMPS MODULE SHORT CIRCUIT CURRENT. FIRE SETBACKS STAMPED 09/22/2022
•17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX ' -, HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). • ''
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE NTS
A AMPERE s u n r u n
AC ALTERNATING CURRENT
AFC! ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION #180120
-- -- - - DC DIRECT CURRENT
(E) EXISTING 6 MYLES STNC$SHM VO IAUHTON.MA OM.) +
ESS ENERGY STORAGE SYSTEM PHONE D
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
MAG MAGNETIC RAQUEL IDROVO
MSP MAIN SERVICE PANEL 23 HIDDEN ACRES AVE,
._--3 (N) NEW YARMOUTH,MA,02673
NTS NOT TO SCALE
i1 OC ON CENTER TEL.(508)280-3611
PRE-FAB PRE-FABRICATED APN:YARM-000058-000031
PSF POUNDS PER SQUARE FOOT PROJECT NUMBER.
PV PHOTOVOLTAIC 223R-0231DR0
~ RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3
TYP TYPICAL V VOLTS MD AAQEBUZZAMAN
W WATTS SHEET
REV NAME DATE COMMENTS COVER SHEET
REV:A 9/21/2022
. PAGE PV-1.0
4
ARRAY TRUE MAG PV AREA
SITE PLAN-SCALE•S/64"=1'-0" PITCH AZIM AZIM (SOFT)
AR-01 30' 237' 251' 156.9
,t; AR-02 30' 237' 251' 58.8
w� y
/ �O�
--(E)RESIDENCEF2
9(.:
(N)ARRAY AR-02 - es.
9L
��yi1'� mASS4 9
G
Q„ q o e CIVIL 1 %
7..................
" �N07.56313 '"
l'o..J.eghar�I /
FEES/ONAIEMb
Qv
/ 8--
•
, E:p:6/30/2024
, STAMPED 09/22/2022
INV PM 0 \ ,,,
(E)DETACHED- / , ,
STRUCTURE ,, ,, -(E)GATEK''''''''''-'-''' ,.
0-
77_,
.:
sunrun
..
•
#180120
/ s PHONE AX WILES sTu oisH o
o rAU"*o ".oz,ao
FAX 0
(N)ARRAY AR-01 CUSTOMER RESIDENCE:
?
RAQUELIDROVO
/ 23 HIDDEN MA,ACRES 67
3YARMOUTH,MA,0 AVE,E
p„ 3
TEL(508)280-3611
/ APN:PROJECTYARM NUMBER:
000031
g NUMBER:
223R-0231DRO
0- DESIGNER: (415)580-8920 ex3
\.7..........7
MD AAOEBUZZAMAN
SHEET
SITE PLAN
REV:A 9/21/2022
PAGE PV-2.0
•
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max ; OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
g Detail OC Spacing Overhang OC Spacing Overhang Configuration
Span Spacing SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-4" 16° COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
_ - S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 13'-0" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16 2.5"MIN EMBEDMENT S.S.
COMP,SEE DETAIL SNR-DC-00436 LAG SCREWS:
5/16":2.5"MIN EMBEDMENT
D1-AR-01-SCALE:3/16"=1'-0" 8"` f ------- 17'-5,. .---.) k-8" STRUCTURAL NOTES:
AZIM:237°
• INSTALLERS SHALL NOTIFY
PITCH:30* ' '.. , •
ENGINEER OF ANY POTENTIAL
STRUCTURAL ISSUES
' 3' " OBSERVED PRIOR TO
L__J I..._- -1 PROCEEDING W/
_ r. _ _ I INSTALLATION.
• IF ARRAY(EXCLUDING SKIRT)
�LIH OFMqS��.- IS WITHIN 12"BOUNDARY
4. �M0Y48S'4cy REGION OF ANY ROOF PLANE
6'-10" NI
_ _ _ o e 44 GT EDGES(EXCEPT VALLEYS),
CIVIL
— � EED
" NO.56313 N THEN ATTACHMENTSEW HI 12"
10 4" TO BE ADDED AND OVERHANG
y, "-"7�- REDUCED WITHIN THE R
TO %mSmoot! , BOUNDARY REGION ONLY AS
_..... _ S/ONALEW" FOLLOWS:
••ALLOWABLE ATTACHMENT
Tv:6/30/2024 SPACING INDICATED ON
PLANS TO BE REDUCED BY
• • • ._ ____ STAMPED 09122/2022
50%
••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
I 1/5TH OF ALLOWABLE
ATTACHMENT SPACING
----6'-0" ------{ 11'-7" INDICATED ON PLANS
D2-AR-02-SCALE:3/16"=1'-0"
AZIM:237° s u n ru n
PITCH:30° . 17,_5,.. 11,_3" t
1,-6„ #180120
Cl ❑ CI L
# "Y ES STM DISHB VD,TAUNTON,M°,03TB6TJ31
PNONE 0
--5%4"TYP 3,5„ FAT o
n n A c) CUSTOMER RESIDENCE:
RAQUEL IDROVO
23 HIDDEN ACRES AVE,
YARMOUTH,MA,02673
TEL.(508)280-3811
APN:YARM-000058-000031
11' PROJECT NUMBER:
223R-023IDR0
DESIGNER: (415)580-8920 ex3
MD AAQEBUZZAMAN
SHEET
LAYOUT
REV:A 9/21/2022
SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0
120/240 VAC
SINGLE PHASE
SERVICE
NOTE:TOTAL PV BACKFEED=20A
METER#: USED FOR INTERCONNECTION
< O EVERSOURCE 2309651 CALCULATIONS
UTILITY
GRID I
1 EXISTING
C
1 200A MAIN
BREAKER
EXISTING (N)MA SMART SOLAREDGE TECHNOLOGIES:
< 225A (N)LOCKABLE UTILITY SE3800H-USMN WITH
�� MAIN BLADE TYPE REVENUE REVENUE GRADE METERING
FACILITY — — PANEL AC DISCONNECT METER 3800 WATT INVERTER JUNCTION BOX PV MODULES
LOADS Ol (3) d) O OR EQUIVALENT 1) LONGI GREEN ENERGY TECHNOLOGY
d // CO LTD:LR4-60HPH-365M
o�� II `r _ �/. �— 11 +(�/ (11)MODULES
v - T OPTIMIZERS WIRED IN:
I 1 (1)SERIES OF(11)OPTIMIZERS
(N)20A o`o SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT L
PV BREAKER AT DU221RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401
OF BUSBAR 120/24OVAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n
3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
695 MYLES STANDISH BLVD,TAUNTON.MA.027604.1
GSOME 0
FAX 0
CUSTOMER RESIDENCE:
RAQUEL IDROVO
23 HIDDEN ACRES AVE,
YARMOUTH,MA,02673
MODULE CHARACTERISTICS TEL.(508)280-3611
P401 OPTIMIZER CHARACTERISTICS:
LONGI GREEN ENERGY MIN INPUT VOLTAGE 8 VDC APN:YARM-000058-000031
TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
LR4-60HPH-365M: 365 W MAX INPUT ISC: 11.75 ADC 223R-023IDRO
OPEN CIRCUIT VOLTAGE: 40.7 V MAX OUTPUT CURRENT: 15 ADC
MAX POWER VOLTAGE: 34.2 V DESIGNER: (415)580-8920 ex3
SHORT CIRCUIT CURRENT: 11.43 A
MD AAQEBUZZAMAN
SYSTEM CHARACTERISTICS•INVERTER 1
SYSTEM SIZE: 4015 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 9/21/2022
SYSTEM OPERATING CURRENT: 10.57 A
SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0
/\WARNING INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
_ IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/CC DISCONNECT(S),
SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(8)
WARNING: PHOTOVOLTAIC
A G POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. ------
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:699.31(0)(2),IFC 2012:
SYSTEM 805.11.1.4
LABEL LOCATION: ■
UTILITY SERVICE METER AND MAIN
SERVICE PANEL. CAUTION .
PER CODE(S):NEC705.12(C) RAPID SHUTDOWN SWIT
AWARNING MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTE ' 1 ,
DO NOT RELOCATE THIS
OVERCURRENT DEVICE LABEL LOCATION: ��
INSTALLED WITHIN 3' 2 SHUT DOWN S u n r u n
LABEL LOCATION: SWITCH PER CODE(S):NECN 200 20:890.56(C)(2),IFC
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3
PEROCPD(IF
CODE(S:NEC202 I I-.- .1 4--- SOLAR PANELS
05CODE(S): EC 2020: 4„
705.121B)(3)(2)
AWARNING 3 ON ROOF
SOLAR PV SYSTEM EQUIPPED #180,20
PHOTOVOLTAIC SYSTEM — -- MAIN PANEL AND P, Eo °°I'Ssr"DISHBL"°TAUNTCN,MN02' '
COMBINER PANEL WITH RAPID SHUTDOWN F AX 0
SERVICE ENTRANCE PV BREAKER
DO NOT ADD LOADS CUSTOMER RESIDENCE:
AC DISCONNECT' DISCONNECT
LABEL LOCATION: 23 HIDDEN
N ACRE
PHOTOVOLTAIC AC COMBINER(IF PV PRODUCTION 23 HIDDEN ACRES AVE,
APPLICABLE). YARMOUTH,MA,02673
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) TURN RAPID SHUTDOWN METER
SWITCH TO THE"OFF" OLAR
,A,.„Es TEL.(508)280-3611
POSITION TO SHUT DOWN INVERTER (EXT)— APN:YARM-000058-000031
PV SYSTEM DISCONNECTIIII
PV SYSTEM AND REDUCE PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT.15.83 AMPS' SHOCK HAZARD IN THE
ARRAY. I
223R-0231DR0
II
NOMINAL OPERATING AC VOLTAGE 240 VAC
DESIGNER: (415)580-6920 ex3
LABEL LOCATION: 23 HIDDEN ACRES AVE, YARMOUTH, MA, 02673 MD AAQEBUZZAMAN
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. .—__- ____— _ SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: SIGNAGE
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 9/21/2022
PER CODE(S):NEC 2020:690.58(C)
PAGE PV-5.0
./