HomeMy WebLinkAboutBLDE-23-002128 Commonwealth of Official Use Only
.u,� Massachusetts Permit No. BLDE-23-002128
� BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/071
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/20/2022
City or Town of: YARMOUTH To the Inspector of Wires.-
By this application the undersigned givcs nonce of his or her intention to perform the electrical work described below.
Location(Street&Number) 11 LINCOLN AVE
Owner or Tenant HICKEY CHARLES F Telephone No.
Owner's Address HICKEY MAUREEN S,11 LINCOLN AVE,WEST YARMOUTH,MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(22 Panels 7.810 KW)
Completion 0'the following table may be waived by the Inspector f Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above 0 In- ❑ No.of Emergency Lighting
grad. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alertinz Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Eauivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Eauivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Eauivalent
OTHER:
Attach additional detail if desired.or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line) Bus.Tel.No.:
Address:166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE:$150.00
_ Commoruvealth oi MaliacktJelti Official Use Only'
��" (,t, c� Permit N Q3— ����'
i= . epartment o`lire .Services
��a'=�1= Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS Rev. 1/07]
0 0 1---.�... .�' (leave blank)
u Liu1
f
;fil , I o ; 4 ' PLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
.�,,,,, cy i x / All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00
Lij (L a •SE PRINT IN INK OR TYPE ALL INFORMATION) Date: [� 1 -a;a
!
J ° City or Town of: yarmou-w) To the Inspector of Wires:
' O /Ely i is application the undersigned gives notice of his or her intention to perform the electrical work described below.
.�oe: tion (Street & Number) It Lin ( 01 1 ptoe_
r AA
er or Tenant 0r a r Le 5 t C_�,Q9 Telephone No. f b 1 , 7n1IB
Q....) . ,•ner's Address 5o_ry1 L . a_b .L
VIs this permit in conjunction with a building permit? Yes 4 No Ti (Check Appropriate Box)
Purpose of Building Utility Authorization No.
EExisting Service 1 co Amps (j / Li(Volts Overhead x Undgrd ElNo. of Meters
New Service Amps / Volts Overhead Ti Undgrd ❑ No. of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: 'tn., 1 on Of ( . fl •, 1r ((yIng C4.0
feDetoe N s``� �- ' aapYifl ��
J C'om letion ofthe ollowin table may be waived b y the Inspector ofWires.
p f g y P
No. of Recessed Luminaires No. of Ceil.-Susp. (Paddle) Fans No. of Total
Transformers KVA
No. of Luminaire Outlets No. of Hot Tubs Generators KVA
No. of Luminaires Swimming Pool Above ❑ In- ❑ No. of Emergency Lighting
grnd. grnd. Battery Units
No. of Receptacle Outlets No. of Oil Burners FIRE ALARMS No. of Zones
No. of Switches No. of Gas Burners No. of Detection and
Initiating Devices ,
No. of Ranges No. of Air Cond. Total Tons No. of Alerting Devices
No. of Waste Disposers Heat Pump Number Tons KW No. of Self-Contained
Totals: Detection/Alerting Devices
--(;) No. of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other
Connection
"I' No. of Dryers Heating Appliances KW Security Systems:*
No. of Devices or Equivalent
E No. of Water Kam, No. of No. of Data Wiring:
Heaters Signs Ballasts No. of Devices or Equivalent
No. Hydromassage Bathtubs No. of Motors Total HP Telecommunications Wiring:
No. of Devices or Equivalent
G�- OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
.8 Estimated Value of Electrical Work: 10(o& j . 0 C) (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10, and upon completion.
INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
1 I certify, under the pains and penalties of perjury, that the information on this application is true and complete.
CO FIRM NAME: Sunrun Installation Services1/ ii LIC. NO.: 4316 Al
6 Licensee: Nathan Ashe Signature hs---- �✓ LIC. NO.: 21136A
(1 applicable, enter "exempt- in the license number line.) No.: 978-594-3519
h 1 f pp pBus. Tel.
`-) Address: 695 Myles Standish BLVD Taunton MA 02780 Alt. Tel. No.:
CI *Per M.G.L. c. 147, s. 57-61 , security work requires Department of Public Safety "S" License: Lic. No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below, I hereby waive this requirement. I am the (check one) ❑ owner ❑ owner's agent.
Owner/Agent PERMIT FEE: $
Signature Telephone No.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:7810W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), i SOLAR MODULES
•MODULES:(22)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE PV-1.0 COVER SHEET
'
LTD:LR4-6OHPB-355M INSTRUCTIONS. ' a" PV-2.0 SITE PLAN
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
11
SE6000H-USSN MP MAIN PANEL • PV-3.0 LAYOUT
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. __ PV-4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436 SNR MOUNT d
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT 8 SKIRT PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35,
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER I FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). 2� T-VENT
AC
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). I= AC DISCONNECT(S)
—, SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
1--1 DC DISCONNECT(S) FIRE SETBACKS
•11.25 AMPS MODULE SHORT CIRCUIT CURRENT.
•17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)8 690.8(B)l. O CB IQ COMBINER BOX HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE:NTS
AC ALTERNATING CURRENT s u n r u n
AFC! ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION #160120
DC DIRECT CURRENT
(E) EXISTING 695 MYLES sTAeNDISH BLVD,TAUNTON.MA,027804831
ESS ENERGY STORAGE SYSTEM FH°NE0
0
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
'C'? MAG MAGNETIC CHARLES HICKEY
MSP MAIN SERVICE PANEL 11 LINCOLN AVE,YARMOUTH,
(N) NEW MA,02673
NTS NOT TO SCALE
OC ON CENTER TEL.(508)737-5718
PRE-FAB PRE-FABRICATED APN:YARM-000053-000017
a PSF POUNDS PER SQUARE FOOT PROJECT NUMBER:
•1 1 Lincoln Ave, PV PHOTOVOLTAIC
West Yarmouth,MA.. RSD RAPID SHUTDOWN DEVICE 223R-011HICK
TL TRANSFORMERLESS
TYP TYPICAL DESIGNER: (115)580-6920 ax3
_==" Ili V VOLTS NAMAN JAIN
W
�" REV NAMEATTS DATE COMMENTS SHEET
COVER SHEET
Whydah Pirate Mu
�..` REV:A 10/16/2022
wesT PAGE
SITE PLAN-SCALE=1/8"=1'-0'• SITE PLAN DETAIL-SCALINCOLE=3/128LNAVE"=1'-0" ARRAY TRUE MAG PVAREA
PITCH AZIM AZIM (SOFT)
"r1I
AR-01 45° 186° 200° 58.8
AR-02 23° 186° 200° 372.E
�.
•
(E)RESIDENCE -.
PL
-7
sae111
I JJ �"la
!-- SE OI PM INV
(E)RESIDENCE a
g
MM.
0 all
/ /
Maw
MI 1 \
•
su nrun
1 i #180,20
till !
695 MYIES STANDISH BLVO.TAUNTON MA,02760,MI
PHONE
FA%0
CUSTOMER RESIDENCE:
i CHARLES HICKEY
11 LINCOLN AVE,YARMOUTH,
(N)ARRAY AR-01 I MA,02673
TEL.(508)737-5718
I APN:YARM-000053-000017
PROJECT NUMBER:
223R-011HICK
(N)ARRAY AR-02 i DESIGNER: (415)580-6920 ex3
NAMAN JAIN
SHEET
SITE PLAN
REV:A 10/16/2022
PAGE PV-2.O
r- - rr
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION _ DESIGN CRITERIA
Name Type Hei ht Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
g yP Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON - WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X10 RAFTERS 9'-10" 16" COMP,SEE DETAIL SNR-DC-00436 2'-0" STAGGERED 1 a0 MPH 3-SEC GUST.
S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 2-Story 2X10 RAFTERS 11'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 1'-11" STAGGERED 5/16":2.5"MIN EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES:
• INSTALLERS SHALL NOTIFY
D1-AR-01-SCALE:3/16"=1'-0" 11" } 11'-7" ; 1'-6" ENGINEER OF ANY POTENTIAL
�
AZIM:186° STRUCTURAL ISSUES
PITCH:45° OBSERVED PRIOR TO
1'-10" i PROCEEDING W/
INSTALLATION.
i • IF ARRAY(EXCLUDING SKIRT)
IS WITHIN 12"BOUNDARY
REGION OF ANY ROOF PLANE
6'-10" won= - _ " • • EDGES(EXCEPT VALLEYS),
THEN ATTACHMENTS NEED
B
TO BE ADDEDDDED AND OVERHANG
: REDUCED 1MTHIN THE 12"
BOUNDARY REGION ONLY AS
FOLLOWS:
••ALLOWABLE ATTACHMENT
12,-4„ SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
8'-11"
••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
D2-AR-02-SCALE:3/16"=1'-0"
AZIM:186° s u n r u n
PITCH:23° f 6" 1'-3"
k4...__._..._._ 17,-5,,. 3,-8„ ; 11,-7.,
1'-4" I _ _ #180120
2.
605 MYLES sruNus"eLw.r•unaw.MA,027804331
PHONE 0 FAX
6-a 6'-11" - - Minni- - - STRUCT= oNL CUSTOMER RESIDENCE:
RLES
I _ fF Fp 1N CENT m MA,02673 HICKEY
MIo�� 4�4, 11 LINCOLN AVE,YARMOUTH,
VINCENT aN MA,02673
g MWUMVANEZA N
CIVIL
TEL.(508)737-5718
1 e C ,, Ep#4,- APE:YARM-000053.000017
��/' ONALf.# PROJECT NUMBER:
6 g" 223R-011HICK
11111 • 4 TYP • u I DESIGNER: (415)580.6920 ex3
II
11„ _. I NAMAN JAIN
31'-2„ , 2' SHEET
LAYOUT
REV:A 10/16/2022
SEE SITE PLAN FOR NORTH ARROW
PAGE PV-3.O
1
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
OEVERSOURCE 2793696
UTILITY
GRID I
---SUPPLY SIDE TAPi'''' c-. NOTE:TOTAL PV BACKFEED=31A
USED FOR INTERCONNECTION
CALCULATIONS
,(4)
1 EXISTING 100A (N)LOCKABLEBLADE TYPE (N)MA SMART
MAIN BREAKER FUSED AC (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES:
DISCONNECT BLADE TYPE REVENUE SE6000H-USSN
1 AC DISCONNECT ; METER 6000 WATT INVERTER JUNCTION BOX PV MODULES
3; ,3, 3 -2,, OR EQUIVALENT %, LONGI GREEN ENERGY TECHNOLOGY
EXISTING I / CO LTD:LR4-60HPB-355M
125A MAIN o,®. I oho I +� 1 *(V/ (22)MODULES
PANEL O OPTIMIZERS WIRED IN:
• FACILITY 35A FUSES I I (1)SERIES OF(11)OPTIMIZERS
�DPL%.ND
LOADS -VA ZIT. L (1)SERIES OF(11)OPTIMIZERS
SQUARED SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT
D222NRB DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
3R,60A 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401
120/240VAC 120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
it CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
SSS MYLES STANDISH BLVD,TAUNTON,MA,02780-7331
PHONED
FA%0
CUSTOMER RESIDENCE:
CHARLES HICKEY
11 LINCOLN AVE,YARMOUTH,
MA,02673
MODULE CHARACTERISTICS
LONGI GREEN ENERGY TEL.(508)
TECHNOLOGY CO LTD: P401 OPTIMIZER CHARACTERISTICS: TEL.
YARM-000053-000017)737-5718
LR4-60HPB-355M: 355 W MIN INPUT VOLTAGE: 8 VDC
OPEN CIRCUIT VOLTAGE: 40.6 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
MAX POWER VOLTAGE: 34.6 V MAX INPUT ISC: 11.75 ADC 223R-011HICK
SHORT CIRCUIT CURRENT: 11.25 A MAX OUTPUT CURRENT: 15 ADC
DESIGNER: (415)580-6920 ex3
NAMAN JAIN
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 7810 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 10/16/2022
SYSTEM OPERATING CURRENT: 20.55 A '1
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
/WARNING INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
ELECTRICAL SHOCK HAZARD
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
r'.' I�t.ARNING POWER SOURCE
LABEL LOCATION.
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS.
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012:
SYSTEM 605.11.1.4
CAUTION .
LABEL LOCATION:
•
UTILITY SERVICE METER AND MAIN
SERVICE PANEL. ■
PER CODE(S):NEC 2020:705.12(C) MULTIPLE SOURCES OF POWER
AIRMIN RAPID SHUTDOWN SWITCH
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS \
OVERCURRENT DEVICE LABEL LOCATION: mm i ��
INSTALLED WITHIN( ON RAPID 0SHUT DOWN u s u n r u n
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC I.
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3
OCPPER (IF APPLICABLE).NEC202 =„■
PER CODE(S):NC 2020 q
705.12(8)(3)(2) •-
. - " _' =II #180120
G SOLAR PV SYSTEM EQUIPPED mill SOLAR PANELS ON ROOF
PHOTOVOLTAIC SYSTEM = sos sruwisH awo,rnuerorv,Mn.oneo-mi
HONECOMBINER PANEL WITH RAPID SHUTDOWN mil F,xo
DO NOT ADD LOADS ,l MAIN PANEL (INT) CUSTOMER RESIDENCE:
1 CHARLES HICKEY
LABEL LOCATION: 11 LINCOLN AVE,YARMOUTH,
PHOTOVOLTAIC AC COMBINER(IF SERVICE ENTRANCE MA,02673
APPLICABLE). TURN RAPID SHUTDOWN FUSED AC DISCONNECT
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c)
SWITCH TO THE DO • AaL. UNFUSED AC DISCONNECT TEL.(508)7375718
POSITION TO SHUT DOWN APN:YARM-000053-000017
PV SYSTEM DISCONNECTII PV SYSTEM AND REDUCE PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT:25.00AMPS1111
SHOCK HAZARD IN THE -PV PRODUCTION METER
223R-011HICK
NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. —INVERTER (EXT)
DESIGNER: (415)580-6920 ex3
LABEL LOCATION: 11 LINCOLN AVE, YARMOUTH, MA, 02673 NAMANJAIN
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. ' SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 S I G NAGE
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 10/16/2022
PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0
I'