Loading...
HomeMy WebLinkAboutBLDE-23-001669 V117"''' Commonwealth ofoffrcialUseOnly Massachusetts Permit No. BLDE-23-001669 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/28/2022 City or Town of: YARMOUTH - To the Inspector of Wires: By this application the undersigned gives notice of his or her mtention to perform the electrical work described below. Location(Street&Number) 9 PINEWOOD RD Owner or Tenant HERICA BATISTA Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters New Service Amps Volts Overhead ❑ Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(15 Panels 5.475 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grad. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Ton. No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: i Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eouivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired.or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.: °Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner ❑owner's agent. Owner/Agent Signature Telephone No. 'PERMIT FEE:$150.00 CV,St (1( w RECEIVED p _"- Commonwealth o/ aiiac etLi O cial Use Zycoct r U, c� n Permit No. L2-12---S 't SEP 2 i.i==°'Ait-W---- o f Jire �ervice3 s�— Occupancy and Fee Checked — '- BUILDING DE`';���` VVT BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07 (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: q I 1 (;, / 10, ,,,,,,;, City or Town of: To the Inspector of Wires: By this application the undersignsyarynoti.:14-) gives notice of his or her intention to perform the electrical work described below. Location (Street & Number) q pi rizwc,, ,,,d .d Owner or Tenant Telephone No.,, " 'fir l ( � ��� �a�'1 �i-t� p ��C'b aq,2 7_5f Owner's Address 5aryti2 CO) QsbadJ Is this permit in conjunction with a building permit? Yes W No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service IOC Amps 110 / ;)LIO Volts Overhead © Undgrd n No. of Meters New Service Amps / Volts Overhead ❑ Undgrd n No. of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: .I lcTU i I(.c}'l Oil 0 -,niercerinze4.ta roo.Cto.p pj , lc) peinAts 5 . y 15 v-,tJ Completion of the following table may be waived by the Inspector of Wires. No. Total No. of Recessed Luminaires No. of Ceil.-Susp. (Paddle) Fans Transformers KVA No. of Luminaire Outlets No. of Hot Tubs Generators KVA No. of Luminaires Swimming Pool Above ❑ In- ❑ No. of Emergency Lighting grnd. grnd. Battery Units No. of Receptacle Outlets No. of Oil Burners FIRE ALARMS No. of Zones of No. of Switches No. of Gas Burners No. Inn and Initiating Devices No. of Ranges No. of Air Cond. Total No. of Alerting Devices g Tons No. of Waste Disposers Heat Pump Number Tons KW No. of Self-Contained p Totals: Detection/Alerting Devices No. of Dishwashers S ace/Area Heatin KW Local DIMunicipal ❑ Other p g Connection _ Heating Appliances Security Systems:* No. of Dryers g pp KW No. of Devices or Equivalent No. of Water No. of No. of Data Wiring: Heaters KW Signs Ballasts No. of Devices or Equivalent dromassa a Bathtubs No. of Motors Total HP Telecommunications Wiring: No. H y g No. of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: 7 4 74 _. c., , (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10, and upon completion. INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury, that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services I LIC. NO.: 4316 Al Licensee: Nathan Ashe Signature 7/..,47_, LIC. NO.: 21136A (If applicable, enter "exempt" in the license number line.) Bus. Tel. No.: 978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt. Tel. No.: *Per M.G.L. c. 147, s. 57-61, security work requires Department of Public Safety "S" License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the (check one) ❑ owner ❑ owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:5475W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), reil SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(15)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SERVICE ENTRANCE LTD:LR4-60HPH-365M INSTRUCTIONS. J P I u - a u PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE3800H-USMN MP MAIN PANEL PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT n PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT 8 SKIRT •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT AC •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). I= AC DISCONNECT(S) r_, SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. 0 DC DISCONNECT(S) FIRE SETBACKS •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[890.8(A)8:690.8(B)]. O CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT -PL- PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION J SHOWN AS DASHED SCALE NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 Whydah Pirate Museum (E) EXISTING ENERGY STORAGE SYSTEM 55 MOLES STNpSH BLVD,TAUNTON.MA.027enrni ESS PM 0 EXT EXTERIOR r 0 A otel INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC HERICA LEAL BATISTA MSP MAIN SERVICE PANEL 9 PINEWOOD RD,YARMOUTH, 0 (N) NEW MA,02673 NTS NOT TO SCALE OC ON CENTER TEL.(508)292-7599 PRE-FAB PRE-FABRICATED APN:YARM-000024-000069 PSF POUNDS PER SQUARE FOOT Pinewood Rd, PV PHOTOVOLTAIC PROJECT22R-0 NUMBER: West Yarmouth MAEAL ... RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)5806920 ex3 TYP TYPICAL V VOLTS SUNIL KUMAR W WATTS SHEET Th Ski(p�per R REV NAME DATE COMMENTS COVER SHEET �h01h'C REV:A 9/23/2022 ._..o PAGE PV-1.O rk r j ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/16"=T-0" PITCH AZIM AZIM (SQFT) fAR-01 21° 327° 341° 156.9 T.I AR-02 21° 147' 161° 137.3 es- OLT- IX::\ . . 4 ' \ \ Py , . .(E)RESIDENCE W a \ a b 7 (N)ARRAY AR-01 -• f; a ,, \ i 4,,,, aj 0i,.. . 4. .. .$ \ ,7. :\,,. e (.) nr n .... #1.0,20 ,,.. ..\ i�� AMP 695 MYLES STMIDISH SLVD TAUMON,MA,027867331 OSE F PHONE o CUSTOMER RESIDENCE: q (N)ARRAY AR-02 HERICA LEAL BATISTA 9 PINEWOOD RD,YARMOUTH, INV PM MA,02673 .-------------\ TEL.(508)292-7599 APN:YARM-000024-000069 , \ P` PROJECT NUMBER: ,g 223R-009LEAL es- DESIGNER: (415)580-6920 ex3 SUNIL KUMAR SHEET \\,........„,„_____ es- SITE PLAN REV:A 9/232022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name TypeHeight TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF 9 Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 9'-9" 16" COMP,SEE DETAIL SNR-DC-00436 -0" 1'-10" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN EMBEDMENT AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 9'-9" 16" COMP,SEE DETAIL SNR-DC-00436 -0" 1'-10" STAGGERED STRUCTURAL NOTES: . • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/4"=1'-0" 1,-1., ENGINEER OF ANY POTENTIAL AZIM:327° -1'-3"r 34'-9" STRUCTURAL ISSUES PITCH:21° OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. 2-2 • IF ARRAY(EXCLUDING SKIRT) P p IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" P = = C — a6'-1 u" BOUNDARY REGION ONLY AS F LLOWS: ••OALLOWABLE ATTACHMENT JI. -5'-4"TYP-------- SPACING INDICATED ON PLANS TO BE REDUCED BY II • • • • • 50% ALLOWABLE OVERHANG I 2'-4" ••INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE - ATTACHMENT SPACING 11'-7" } 11'-7" INDICATED ON PLANS D2-AR-02-SCALE:1/4"=1'-0" AZIM:147° s u n ru n PITCH:21° 12'-2" 23'-3" 1'-9" STRUCT OcOFM4 1 #180120 ❑ I...1 )_� ❑ rI -_- MSWILSST09NBLVD,TAUNTON,MA,°l/10.7 WCENT mVANEZAIVIL • 2 CUSTOMER RESIDENCE: HERICA LEAL BATISTA o�� 9 PINEWOOD RD,YARMOUTH, MA,02673 5.-4"TYP r TEL.(508)292-7599 APN:YARM-000024-000069 C) l7 ) (� (� j PROJECT NUMBER: 223R-009LEAL 3,�8„ DESIGNER: (415)580 8920 ex3 SUNIL KUMAR SHEET LAYOUT REV:A 9/23/2022 SEE SITE PLAN FOR NORTH ARROW PAGE pV-3.0 I 120/240 VAC SINGLE PHASE SERVICE M O METER#: NOTE:TOTAL PV BACKFEED=20A EVERSOURCE 2307287 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID --SUPPLY SIDE TAP I ,(4) 1 EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT METERVUE SE3800H-USMN 3800 WATT INVERTER JUNCTION BOX PV MODULES 31 ,".3: [-2', OR EQUIVALENT (1) LONGI GREEN ENERGY TECHNOLOGY EXISTING h / CO LTD:LR4-6OHPH-365M 125A MAIN `o, M `^ —.� —� I ' // (15)MODULES PANEL U — - OPTIMIZERS WIRED IN: FACILITY —* 20A FUSES I I (1)SERIES OF(15)OPTIMIZERS LOADSFACILITY GROUND SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHWTHWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 695 MYLES STANDISH BL.VD,TAUNTON,MA,027004.1 PHONED FAX CUSTOMER RESIDENCE. HERICA LEAL BATISTA 9 PINEWOOD RD,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(508)292-7599 P401 OPTIMIZER CHARACTERISTICS: LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000024-000069 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPH-365M: 365 W MAX INPUT ISC: 11.75 ADC 223R-009LEAL OPEN CIRCUIT VOLTAGE: 40.7 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE 34.2 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.43 A SUNIL KUMAR SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 5475 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 15 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 9/23/2022 SYSTEM OPERATING CURRENT: 14.41 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 AWARNING INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:890.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWSE SPECIFIED. AC COMBINER PANEL OF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 605.11.1.4 LABEL LOCATION: UTILITY SERVICE METER AND MAIN — SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) AWARNING RAPID SHUTDOWN SWITCH cAuTIoN . POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS MULTIPLE SOURCES OF POWER OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN RAPID SHUT DOWN s u n r u n LABEL LOCATION: SWITCH PER CODE(S):NEC2020:890.58(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012,605.11.1,IFC 2018:1204.5.3 �, -SOLAR PANELS ON ROOF OCPD(IF APPLICABLE). � PER CODE(S):NEC 2020: 4" 1_\_ 705.12(8)(3)(2) AWARNING SOLAR PV SYSTEM EQUIPPED -L _ #180120 PHOTOVOLTAIC SYSTEM EOwxH ssrSH aw ww mn�v,rsr .un, u1 COMBINER PANEL WITH RAPID SHUTDOWN °AX0 - DO NOT ADD LOADS CUSTOMER RESIDENCE: HERICA LEAL BATISTA LABEL LOCATION: 9 PINEWOOD RD,YARMOUTH, PHOTOVOLTAIC AC COMBINER OF). MA,02673 PER CODE(S): R ):NEC 2020:705.12(D)(2)(3)(c) TURN RAPID SHUTDOWN SWITCH TO THE"OFF' OLp.p,nl C R TEL.(508)292-7599 POSITION TO SHUT DOWN e e APN:YARM-000024-000069 — PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE MAIN PANEL LINVERTER PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:15.83 AMPSSHOCK HAZARD IN THE (EXT) 223R-009LEAL ll - NOMINAL OPERATING AC VOLTAGE 240 VAC ARRAY. a (I N T) LABELOCATION: —PV PRODUCTION METER DSUNILKUMAR (415)580�920ex3 A NTERCONNECTION.PHOTOVOLTAIC SYSTEM POINT OF —FUSED AC DISCONNECT SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: C SIGNAGE ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE --S p ERVICE ENTRANCE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. 9 PINEWOOD RD, YARMOUTH, MA, 02673 REV:A 9/23/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 t