Loading...
HomeMy WebLinkAboutBLDE-22-005363 or t,. Commonwealth of Official Use Only ft Massachusetts Permit No. BLDE-22-005363 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/24/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 39 PAYSON PATH Owner or Tenant Helen Ho Telephone No. Owner's Address 39 PAYSON PATH,WEST YARMOUTH, MA 02673 ‘ Is this permit in conjunction with a building permit? Yes 0 No 0 (C 4,,1 1 rop s,,x) Purpose of Building Utility Authorization No. , � Existing Service Amps Volts Overhead 0 Undgrd 0 r New Service Amps Volts Overhead 0 Undgrd 0 I t - 6, &, Number of Feeders and Ampacity � Location and Nature of Proposed Electrical Work: Installation of solar PV system(9 Panels 2.925 KW) v 0 Completion of the following table ma�e w 'v•� ,ector of Wires. iti No.of Recessed Luminaires No.of Cetl.-Sus . Paddle Fans No.of �( O otal p( ) Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators �� KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons Heat Pump Number Tons KW No.of Self-Contained No.of Waste Disposers Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 • RECEIVED j�/ �` Commonwealth o/fl assachuietti Official Use Only __ MAR '7 t c� �7 `r- S)ILJ5 2�-: - .2'epartmenl o�.}ire services Permit No. -`Ft f--r, NT Occupancy and Fee Checked BUILDING D- : OARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 3-g 3- IX City or Town of: VQrrn1Th` To the Inspector of Wires: By this application the undersigned fives tice of his or he 'ntertion to perform the electrical work described below. Location(Street&Number) � 1 1My� Owner or Tenant Telephone No.F -WI-7163 Owner's Address Onlet QS ()Mt) Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building LnoNki Utility Authorization No. Existing Service /80 Amps /oioVolts Overhead E Undgrd❑ No.of Meters I New Service Amps / Volts Overhead n Undgrd El No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Ins I I Q-I Cfl it � Nv nled pimvo iC Gr Sfitrn ; 1cir sa. 5 Kam Completion of the following table may be waived by the Inspector of Wires. No. rano KVA Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners 1FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of AlertingDevices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection ❑ Other No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: ( �Q Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Valu of rical Work: �,ti , ,�� (When required by municipal policy.) (A0Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such cove e is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE / BOND El OTHER ❑ (Specify:) I certify,under t p 'its and pen !ties of perjuty,that the information on this application is true and complet . 1 FIRM NAME: LIC.NO.: Licensee: , Signature LIC.NO.: (If applicable enter -exempt"in the license number line,),-. Bus.Tel.No.:C /MgU 'Mill ,Address: Cq.5. (fli$ SiOndiSn L 1Ld, IOUnir��n i fig H , t.CY 7.70 Alt.Tel.No.: *Per M.G.L. c. 147, 57-61,security work requires Department of Public Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)El owner El owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ r > wApi SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS --_- — — — PAGE # DESCRIPTION • SYSTEM SIZE 2925W DC. 3840W AC • ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC). SOLAR MODULES • MODULES (9) JA SOLAR: JAM60S17-325/MR MUNICIPAL CODE. AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION COSERVICE ENTRANCE PV-1.0 COVER SHEET t • INVERTERS: (1) DELTA ELECTRONICS E4-TL-US INSTRUCTIONS. .. `' PV-2.0 SITE PLAN • RACKING SNAPNRACK RLU RL UNIVERSAL. SPEEDSEAL • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. -�� TRACK ON COMP. SEE DETAIL SNR-DC-00436 • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. MP) MAIN PANEL u u u PV-3.0 LAYOUT • RAPID SHUTDOWN. (9) APSMART RSD-S-PLC ROOFTOP • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY �� PV-3.1 STRUC. UPGRADES MODULE LEVEL RAPID SHUTDOWN DEVICE GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. o �'• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. (sr) SUB-PANEL SNR MOUNTPV-4.0 ELECTRICAL - SNR MOUNT & SKIRT • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. PV-5.0 SIGNAGE • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. l • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II 0I PV LOAD CENTER CHIMNEY MODULES, ARE CLASS A FIRE RATED. 1 • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® SUNRUN METER ATTIC VENT • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. FLUSH ATTIC VENT • 10.23 AMPS MODULE SHORT CIRCUIT CURRENT. PM DEDICATED PV METER • 15.98 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. - PVC PIPE VENT • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INV INVERTER(S) METAL PIPE VENT LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION ® T-VENT AC AC DISCONNECT(S) SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKS (GB) IQ COMBINER BOX HARDSCAPE P 1 INTERIOR EQUIPMENT — PL— PROPERTY LINE L _1 SHOWN AS DASHED SCALE NTS A AMPERE sunrun AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT a 0 (E) EXISTING o95 MYLES STANDISH BLVD TAUNTON MA 02780-7331 ESS ENERGY STORAGE SYSTEM FAoOEo 7 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE' MAG MAGNETIC HELEN HO a MSP MAIN SERVICE PANEL 39 PAYSON PATH. YARMOUTH, ". 17 (N) NEW MA, 02673 4 .,4,- ' uJ r'• Pa' '� " 9 v NTS NOT TO SCALE S OC ON CENTER TEL. (508) 247-7703 '39 Payson Path. M` PRE-FAB PRE-FABRICATED APN YARM-000086-000120 West Yarmouth,MA PSF POUNDS PER SQUARE FOOT PROJECT NUMBER PV PHOTOVOLTAIC- 223R-039H01 RSD RAPID SHUTDOWN DEVICE s y TL TRANSFORMERLESS DESIGNER (415) 580-6920 ex3 TYP TYPICAL o °a V VOLTS JULEEN APOLINAR s N q W WATTS o-Harvey Wholesat SHEET o ComportREV NAME DATE COMMENTS COVER SHEET 9 w REV: Al 03/15/2022 0 0 PAGE I' PV-1 .0 rn,,swetl Path r '4 ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=1/16"-1'-0" PITCH AZIM AZIM (SOFT) \�l 7 Mp AR-01 28° 81° 95° 163 PM SE 0 (E)DRIVEWAY ®O PI. Pi- Pt. \-------- . . A. a • a e • • 0 ° e c : : .0. a .. a ,n S y % \ , A . ° ' ' A lit N \ II sunrun ,i #180120 PH NE 0 sTNIgsH BLVD.TMIMON,4.,WOW. FqX 0 CUSTOMER RESIDENCE: HELEN HO 39 PAYSON PATH,YARMOUTH, MA,02673 -� PL TEL.(508)247-7703 _ PL PROJECT NUMBER: APN:YARM-000086-000120 PL (N)ARRAY AR-01 \__________ ai 223R-039H01 (E)RESIDENCE DESIGNER: (415)580-6920 ex3 JULEEN APOLINAR SHEET SITE PLAN NOTE:ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE INSTALLED ON EACH MODULE PER NEC 690.12 REV:Al 03/15/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF YP g YP Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 16'-7" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:COMP,SEE DETAIL SNR-DC-00436 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: 01-AR-01-SCALE:1/4"=1'-0" 5/16"X4.5":2.5"MIN EMBEDMENT PITCH:28° STRUCTURAL NOTES: AZIM:81° • INSTALLERS SHALL NOTIFY AlkENGINEER OF ANY SISTERING REQUIRED POTENTIAL STRUCTURAL rap UNDER ARRAY ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. • IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" / BOUNDARY REGION OF ANY I I ROOF PLANE EDGES (EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE I ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ••ALLOWABLE OVERHANG 12' INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING 1 INDICATED ON PLANS i ID � ❑ 0 0 sunrun } 5.-4"TYP } #180120 . 605 MYLES STAN016H•LVD,TAUNTON,MA,027.7331 0 ❑ lao- ❑ ❑ 0 El PHONE 0 CUSTOMER RESIDENCE: HELEN HO 39 PAYSON PATH,YARMOUTH, n C) (! n n n n4CTEL. MA,02673 1 (508)247-7703 I APN:YARM-000086-000120 T-8" 28' 1'-0"{_ PROJECT NUMBER: l 1 , 223R-039H01 s 150," DESIGNER: (415)580-6920 ex3 /ONALt4' JULEEN APOLINAR Wood on.3/22/2022 SHEET LAYOUT REV:Al 03/15/2022 PAGE PV-3.0 NOTES. TABLE 1:ACCEPTABLE MIN.LUMBER TYPE 1. PROVIDE(N)"B"SISTERED RAFTERS TO(E)RAFTER,SEE LUMBER SPECIES&GRADE MIN.BENDING Fb(psi) DETAILS. 2. ATTACH(N)SISTER TO(E)MEMBER w/ATTACHMENT(SEE DOUG FIR-LARCH#2 900 SCHEDULE)STAGGERED ALONG SPAN w/1"EDGE DISTANCE SOUTHERN PINE#1 1500 AND(6)AT EACH END w/1"EDGE DISTANCE. HEM-FIR#2 850 3. SINGLE SISTER MEMBER IS ACCEPTABLE IF SINGLE SISTER SPRUCE PINE FIR#2 875 LENGTH MATCHES THE MINIMUM SISTER LENGTH. IT 4. SISTERING TO BE CENTERED ON(E)MEMBER SPAN. SEa�ENG -� \ ZN ' I ) TABLE 2:ACCEPTABLE ATTACHMENT SCHEDULE Moo-s..C" . ' --L-L\ ( 1,2 • — FIELD i • • �' / f • • • — OPTION TYPE SPACING #AT END 1.3 —/• • \ 1 2 i% 1 Simpson Strong-Drive® 12"OC 6 •_ —— SDW EWP-PLY Screw* �� • • �� / /�' 'h\ 2 COMMON 10d thru 16d 6"OC 6 ATTACHMENT TYPE PER P, ' --�' ——' / TABLE 2 SCHEDULE • • \ TABLE 3: UPGRADE SPECIFICATIONS -- (N)"B"SISTER ( • I CALLOUT VARIABLE 1.3 • • �• ' I1 • •• I RAFTER SIZE"B" 2x6 —' -• ' ,.•pN- \ • —— MIN.SISTER LENGTH"Cr. 14'-1" • ''/ �' \ i—'// / Tor 2-Ply Sistering Use Model#SDW22338 �� / For 3-Ply Sistering(Al Splice Locations)Use Model#5DN22500 r'�/� / / \ f 1 __I \_ _J 1---- r- L.i '- 1 � JOIST END sunrun END CONDITION(TYP.)PER TABLE 2 SCHEDULE (E)BEARING WALL ADD(N)"B"EA SIDE #180120 O ELEVATION VIEW (N)SISTER SEE SCHEDULE FOR 1.1 RAFTER ATTACHMENT AND ees ay.ES STANDISH BLW,rAUNTON.Sc,oPeo-].ill PHONED SCALE: NTS A- IIILUMBER TYPE F.0 __ _ L� CUSTOMER RESIDENCE: a HELEN HO (E)RAFTER ,� 39 PAYSON PATH,YARMOUTH, / ?� SAMUEL MA,02673 4'-0" MIN. ���`or m., TEL.(508)247-7703 ATTACHMENT APN:VARM-000086-000120 O TOP VIEW 2 BROWN .n 1.2 SCHEDULE -, ; PROJECT NUMBER: SCALE: NTS O SECTION o Q�Jy/ ; 223R-039H01 1.3 SCALE: NTS U N O. J , 3 • y NOTES: SEE SECTION 1.1 FOR l% tNSTE O ,�! DESIGNER: (415)560 6920 ex3 ATTACHMENT NOTES "'O ��6, !K_,�t% SKINA0-4' JULEEN APOLINAR OSISTERING DETAILS Signed en 3/22/2022 SHEET CALE:NTS STRUC. UPGRADES REV:Al 03/15/2022 PAGE PV-3.1 t r 120/240 VAC SINGLE PHASE SERVICE METER#: O EVERSOURCE 2285386 UTILITY GRID I r.........„,,—SUPPLY SIDE TAP (I EXISTING 100A (N)BLADE LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC (N)LOCKABLE UTILITY DELTA ELECTRONICS: DISCONNECT BLADE TYPE REVENUE E4-TL-US I AC DISCONNECT METER 3840 WATT INVERTER JUNCTION BOX PV MODULES o OR EQUIVALENT Q EXISTING 3 Q A �, O JA SOLAR:JAM60S17-325/MR O A / (9)MODULES / 100A MAIN ,,o' _ °�� `� _ 'O./ (1)STRING OF(9)MODULES FACILITY PANEL 30A FUSES v �' — V (9)APSMART RSD-S-PLC MODULE LOADS .=, SQUARE D SQUARE D 240V METER SOCKET LOAD RATED DC —I --I--LEVEL RAPID SHUTDOWN DEVICES D221NRB DU221RB 100A CONTINUOUS DISCONNECT WTH AFCI, NOTE:TOTAL PV BACKFEED=20A 3R,30A 3R,30A,2P UTILITY SIDE OF CIRCUIT APSMART TRANSMITTER USED FOR INTERCONNECTION 120/240VAC 120/240VAC CONNECTS TO TOP LUGS- CALCULATIONS (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 60S MYLES STAN..BLVD,TAUNTON,OF 02780-7331 PHONED FAX 0 CUSTOMER RESIDENCE: HELEN HO 39 PAYSON PATH,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(508)247-7703 JA SOLAR:JAM60S17-325/MR: 325 W APN:YARM-000086-000120 OPEN CIRCUIT VOLTAGE: 40.87 V MAX POWER VOLTAGE: 33.97 V PROJECT NUMBER: SHORT CIRCUIT CURRENT: 10.23 A 223R-039H01 DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 JULEEN APOLINAR SYSTEM SIZE: 2925 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 410 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 306 V MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 9.57 A REV:Al 03/15/2022 SYSTEM SHORT CIRCUIT CURRENT: 12.79 A PAGE PV-4.0 AWARNING INVERTER 1 NOTES AND SPECIFICATIONS •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 400 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S).NEC 2020:690.31(D)(2),IFC 2012: SYSTEM 695.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) AWARNINGRAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF— IN1 DO NOT RELOCATE THIS `" OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN .,— LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 4" 705.12(8)(3)(2) f AWARNING SOLAR PV SYSTEM EQUIPPED #180120 MVLES STANDISH BLVD,TAUNTON MA,02780-7331 PHOTOVOLTAICCOMBINER WITH RAPID SHUTDOWN `A%0 1 DO NOT ADD LOADS CUSTOMER RESIDENCE. LHELEN HO LABEL LOCATION: FUSED AC DISCONNECT 39 PAYSON PATH.YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). MAIN PANEL (INT) _ MA,02673 PER CODE(S)'NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN SWITCH TO THE.,OFF.' SERVICE ENTRANCE TEL.(508)247-7703 POSITION TO SHUT DOWN ••AMa,ELEC PV PRODUCTION METER APN:YAR M-000086-000120 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:16_00AMPS SHOCK HAZARD IN THE Ell UNFUSED AC DISCONNECT 223R-039H01 ! ARRAY. INVERTER (EXT) NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: JULEEN APOLINAR AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF • 39 PAYSON PATH, YARMOUTH, MA, 02673 INTERCONNECTION. - SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION. ON OR NO MORE THAT 1 M(3 FT(FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:Al 03/15/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0