HomeMy WebLinkAbout9 Equipment Layout Plan Maintenance-Sheet No. EQ1.01i
2 3 4 S 6 o 6.5 8 8.2 o 00
I � I
EXISTING LIFT TO BE RELOCATED I I RADIANT FLOOR HEATING EQUIPMENT LOCATED IN THIS AREA
BY CONTRACTOR (ERC). SEE SPEC I VEHICLE AND EQUIPMENT STORAGE
SECTION 14 45 DO - VEHICLE LIFTS
° VEHICLE PROFILE I ° ° ! 0 136 MB-34
° °
o° oM MB-35b
.,.. MB-1
MB-27
M-10"rh
MB-7.
rJ PB-21 VIB
MB-3 MB-26 �; MB-26 I,1
PB-15
I3-3ra N�o-ov I MB-8
I N PB-6 I I j MB-21 MB-27 ti
a PB-12 o-FMB.22 MB-2 MB-17 m i
-o
of I
WASH BAY � PB-7 �`= MB-37
CENTER SUMP AND TRENCH I
e
�� PB-11 �`�
DRAIN. SEE STUCTURAL PLANS 144 ` MB-1 MB-36 I I
� �I
I - VW-3 �z-�. � ; MB-28 - I
FOR DETAILS I`
( � � o � _ I I MB-8 MB-8 m 1
( _ - - uMB-6 M o9 10"
m
VEHICLE EXHAUST REEL--�-PB-4 gHj{v C FSB CONTRACTOR LE EXHAUST REEL�IT__
MB-11 I I BY HVAC FSB CONTRACTOR I�
DPW VEHICLE 0-Fs-7VW-7j II I I a �-I MB-S MB-27 MB-27
J _B-39 MAINTENANCE EXISTING ONTRACTOR ERC SEE SPEC II'o L�
PB-18 (ERC).
141 SECTION 14 45 00 -VEHICLE LIFTS a r ml E
VW-4 FS-66 0 �� I I `.r. I MB-27 MB-27 8-2 I
� PB-19 I rc
- _ - - - - - - - r• ---- -- -
7,11 IT,
J 5 o PB-11 MB-23 L_ - -
- - - - _ - --- i
`APB-20 8'-O" MB-20,
\ u o o ii ii u u iia
`• PB-14 a ii a I,
ii
�x I VW-s I I L 1 1 I V
VW-12 VW-9B I I ... FS-9 -
�- FS-6A _ M_B-42 - -. FS-1
-MB-3o- ---- - TOILE--� CoK
�� ----- --.-- -_- - __-_ __ - - - --- _ - o
1 � MB 29A
3, _ 0" PB-23 MB-40 M8-9 MB-29-
I �.
� _ _ _ 1/V1t-9A MB-4 B-44 MB-42 FS-9
i
it
X W-8 VW-1A
BID ALT N0.1
V�
FS-2 FLUIDS ROOM ! -/
PREFABRICATED TRENCHES VW-8�
FOR UNDERCARRIAGE WASH BY VW-10'I I I I I -
MECHANICS
PLUMBING FSB. (SEE NOTE 7) OFFICM IF 4 +-
VW-10 VW-5A-� I'
]=+PB-10( _ _ o = - _ MB-24 140 FS-5
l 8-I VW-� k-VW-8
_
r;
o ,
i I o ff, o VEHICLE EXHAUST REEL MB-28
BY WAG FSB CONTRACTOR , / = FS--9 FS-3 I
,
- I
° vw-6 ° ° ° ° j ° ° j
fi
- - � V NT PIPING FOR TIGHT TANK AND OILWATER SEPARATOR
r- -► E
}
- I I I VW-13 I I LOOP DETECTOR SHALL BE FURNISHED: AND INSTALLED LOCATED AGAINST WALL IN THIS AREA
I I BY THE VEHICLE WASH CONTRACTOR. LOOP
L _ _ J DETECTOR SHALL BE CONNECTED TO THE, AUTOMATIC
HEAUTOMATIC
UNDERCARRIAGE WASH SYSTEM TO ARM THE
PHOTOEYES. I I
i I I I
1 2 3 4 6 6.5 8
0 8.2
0
EQUIPMENT LAYOUT PLAN MAINTENANCE
GENERAL NOTES: ABBREVIATIONS:
1. EQUIPMENT LAYOUTS ARE SCHEMATIC. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING EXACT LOCATIONS WfTH OWNER'S MECHANICS AND N NEW EQUIPMENT TO BE SUPPLIED AND INSTALLED BY THE CONTRACTOR.
MANUFACTURER REQUIREMENTS. COORDINATE ALL UTILITY REQUIREMENTS WITH SUB -CONTRACTORS. FINAL EQUIPMENT LOCATIONS SHALL BE CONFIRMED BY THE
OWNER'S MECHANICS PRIOR TO RUNNING UTILITIES AND INSTALLATION EQUIPMENT.
ERC EXISTING EQUIPMENT TO BE RELOCATED AND INSTALLED BY THE CONTRACTOR.
2. GENERAL CONTRACTOR SHALL COORDINATE UTILITY REQUIREMENTS OF EXISTING EQUIPMENT PRIOR TO INSTALLATION OF SERVICES. UTILITIES FOR ERC EQUIPMENT TO BE PROVIDED BY THE FILED SUB -BID CONTRACTORS
3, PRIOR TO RUNNING UTILITIES, GENERAL CONTRACTOR SHALL MARK OUT ALL EQUIPMENT LOCATIONS ON THE FLOOR USING TAPE OR ANOTHER ACCEPTABLE MEANS, AND
SHALL REVIEWIREVISE FINAL EQUIPMENT LOCATIONS AS DIRECTED BY THE OWNER, OWNER'S MECHANICS AND THE ENGINEER. ERO EXISTING EQUIPMENT TO BE RELOCATED AND INSTALLED BY THE OWNER.
4. PB-11, PB-23, MB-40, MB-9 AND MS-30 SHALL ALL BE CENTERED IN THE MAINTENANCE BAYS AS DEFINED BY THE OVERHEAD DOOR OPENING. CONFIRM INSTALLATION UTILITIES FOR ERO EQUIPMENT TO BE PROVIDED BY THE FILED SUB -BID CONTRACTORS.
LAYOUT DIMENSIONS WITH THE MANUFACTURER. ALSO SEE OWNER'S MANUALS.
NIC NEW EQUIPMENT (PROVIDED AND INSTALLED BY THE OWNER (NOT IN CONTRACT),
5. ELECTRICAL, MECHANICAL, AND PLUMBING FSBs SHALL PROVIDE AND CONNECT UTILITIES TO ALL EQUIPMENT AS SHOWN ON THE ELECTRICAL, MECHANICAL AND HOWEVER UTILITIES FOR THIS EQUIPMENT SHALL BE PROVIDED BY THE FILED SUB -BID
PLUMBING DRAWINGS AND SPECIFICATIONS, AND IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS IN ORDER TO PROVIDED A COMPLETE AND OPERABLE CONTRACTORS.
SYSTEM.
6. THE ELECTRICAL CONTRACTOR SHALL HAVE A MASSACHUSETTS LICENSED ELECTRICIAN CONFIRM THE VOLTS, PHASE, AMPS, AND NEMA PLUG CONFIGURATION FOR FSB FILED SUB -BID SUBCONTRACTOR
EACH PIECE OF EQUIPMENT (INCLUDING EXISTING EQUIPMENT TO BE RELOCATED) IN ADVANCE OF ORDERING MATERIALS AND INSTALLATION.
7. THE TRENCH DRAINS SHALL BE INSTALLED BY THE PLUMBING FSB HOWEVER THE H2O WHEEL LOAD RATED STEEL COVERS FOR TRENCHES SHALL BE FURNISHED BY NIA NOT APPLICABLE
VEHICLE WASH CONTRACTOR. COVERS FOR TRENCH SHALL BE STAINLESS STEEL AND SHALL COVER THE ENTIRE LENGTH OF TRENCHES, INSIDE AND OUTSIDE OF THE
GUIDE RAILS.
8. UNDERCARRIAGE SPRAY BAR MANIFOLD LOCATED IN UNDERCARRIAGE TRENCHES SHALL BY FURNISHED AND INSTALLED BY THE GENERAL CONTRACTORS VEHICLE WASH
SUBCONTRACTOR, SEE SECTION 111126.
II '
JUL '1 5 2021
HEALTH( DEPT.
Industrial Equipment Schedule
Equipment
EQ Number Description Count Type Spec Number Notes
FS-1
120 gal Fluid Storage Tank (15W-40)
1
N
111129
FS-2
120 gal Fluid Storage Tank (5W 20)
1
N
111129
FS-3
120 gal Fluid Storage Tank (Hydraulic Oil)
1
N
111129
FS-4
60 gal Fluid Storage Tank (Waste Antifreeze)
1
N
111129
FS-5
1000 gal Fluid Storage Tank (Waste Oil)
1
N
111129
FS-6A
Lube Reel Bank
1
N
111129
FS-613
Lube Reel Bank
1
N
111129
FS-7
Waste Oil Caddy
2
N
111129
FS-8
Waste Antifreeze Caddy
1
N
111129
FS-9
Fluid Pumps
3
N
111129
MB-1
Tire Changer
1
ERO
N/A
MB-2
Welder
1
ERO
N/A
MB-3
Plasma Cutter
1
ERO
NIA
MB-4
Hose Crimper
1
ERO
N/A
On Mezzanine
MB-5
Small Drawer
1
ERO
NIA
MB-6
Maintenence Torch Cart
1
ERO
N/A
MB-7
Bottle Jack
1
ERO
N/A
MB-8
Parts Storage
3
ERO
NIA
MB-9
18K 2 Post Lift
1
ERC
14 45 00
MB-10
Flammable Storage 45 Gal
3
ERO,
N/A
MB-11
Shop Press
1
ERO
N/A
MB-12
Chop Saw
1
ERO
N/A
On Mezzanine
MB-13
Small Bin
1
ERO
N/A
MB-14
Hose Parts Bin
1
ERO
N/A
On Mezzanine
MB-15
Hose Storage
1
ERO
N/A
On Mezzanine
MB-16
Hose Parts Drawers
1
ERO
N/A
On Mezzanine
MB-17
Floor Jack
1
ERO
N/A
MB-18
MB Battery Charger
1
ERO
N/A
MB-19
Old Welder
1
ERO
N/A
MB-20
Small Parts Washer
1
ERO
N/A
MB-21
Maintenance Tool Box
1
ERO
N/A
MB-22
Drill Press
1
ERO
N/A
MB-23
Portable Grease Caddie
1
ERO
N/A
MB-24
Power Washer
1
ERO
N/A
MB-25
10 Ton Bottle Jack
2
ERO
N/A
MB-26
Parts Shelving (4ft)
2
NIC
N/A
MB-27
Parts Shelving (6ft)
10
NIC
NIA
MB-28
Cantilever Rack (Level)
3
N
12 40 00
BID ALT NO.1
MB-29A
Waste Oil Pumpout
1
N
111129
MB-29B
Waste Antifreeze Pumpout
1
N
111129
MB-30
70,000lbs Inground Lift
1
N
14 45 00
MB-30a
Inground Lift Control (Wall Mounted)
1
N
14 45 00
MB-31
Refrigerant Recovery Machine
1
N
12 40 00
BID ALT NO.1
MB-32
Tire Rack
3
N
12 40 00
BID ALT NO.1 On
Mezzanine
MB-33
Welding Screen
2
N
12 40 00
BID ALT NO.1
MB-34
Oil Bar
1
N
111129
Vehicle Storage Garage
MB-35a
Steel Work Bench (72inx36in)
4
N
12 40 00
BID ALT NO.1 One Located
on Mezzanine
MB-35b
Steel Work Bench w/ Electric Shelf (72inx36in)
1
N
12 40 00
BID ALT N0. 1 One n ( 1 ) with
Electric Shelf
MB-36
Weld Table
1
N
12 40 00
BID ALT NO.1
MB-37a
Bench Vise
2
N
12 40 00
BID ALT NO.1
MB-37b
Big Weld Vise
1
N
12 40 00
BID ALT NO.1
MB-38
Band Saw
1
N
12 40 00
BID ALT NO.1
MB-39
Bench Grinder on Pedestal
1
N
12 40 00
BID ALT NO.1
MB-40
18K 2 Post Lift
1
N
14 45 00
MB-41
5 Ton Bridge Crane
1
N
142213
MB-42
High Level Alarm
2
N
111129
MB-43
Bottle Jack
1
N
12 40 00
BID ALT NO.1
MB-44
Fluid Storage Sump Alarm
1
N
111129
MB-45
Tight Tank High Level Alarm
1
N
132170
PBA
Police Torch Cart
1
ERO
N/A
PB-2
Floor Jack
2
ERO
NIA
PB-3
Brake/Rotor Machine
1
ERO
NIA
PB-4
Tire Changer
1
ERO
N/A
PB-5
Tire Balancer
1
ERO
NIA
PB-6
Bench Grinder
1
ERO
N/A
PB-7
Bench Vise
1
ERO
N/A
PB-8
Bench Tool Box
1
ERO
N/A
PB-9
Metal Parts Drawers
1
ERO
NIA
PB-10
Battery Charger
1
ERO
NIA
PB-11
10K 2 Post Lift
1
ERC
14 45 00
PBA 2
Gun Cabinet
1
ERO
NIA
Wall Mounted
PB-13
Tool Box
1
ERO
NIA
PB-14
OEM Cart
1
ERO
N/A
PB-15
Parts Drawers
1
ERO
NIA
PB-16
Not Used
1
NIA
NIA
P13-17
Police Tire Rack
1
ERO
NIA
PB-18
12 Ton Shop Press
1
ERO
NIA
PB-19
Portable Grease Caddie
1
ERO
ILIA
PB-20
Shop Vacuum
1
ERO
N/A
PB-21
Police Drill Press
1
ERO
NIA
PB-22
Steel Work Bench wl Casters (72inx36in)
2
N
12 40 00
BID ALT NO.1
PB-23
16K 2 Post Lift
1
N
14 45 00
BID ALT NO.1
VW-1
Pressure Washer
1
N
111126
VW-1A
Manual Wash Pump Control Panel
1
N
111126
VW-2
Vehicle Wash - Hot Water Heater
1
N
111126
VW-3
Vehicle wash Boom
1
N
111126
VW-4
Vehicle Wash Mobile Platform
1
N
111126
VW-5
Automatic Undercarriage Pump Skid
1
N
11 1126
VW-5A
Under Carriage Wash Control Panel
1
N
11 1126
VW-6
Automatic Undercarriage Photo Eye
2
N
111126
VW-7
Vehicle Wash Pressure Washer Controls
1
N
111126
VW-8
Rocker Panel/ Wheel Washer
1
N
111126
VW-9
Water Reclaim System
1
N
111126
BID ALT NO.1
VW-9A
Water Reclaim (Controls/Enzyme)
1
N
111126
BID ALT NO.1
VW-913
Water Reclaim (Ozone Generator)
1
N
111126
BID ALT NO.1
VW-10
Undercarriage Wash Manafold Pre -Fab Trench Drains
2
N
Div 22
VW-11
Vehicle Wash Guide Rails
1
N
111126
VW-12
Vehicle Wash Pre -Treatment Tank (1500gal)
1
N
11 11 26
VW-13
Loop Detector
1
N
111126
LEGEND
HATCHES
LINE TYPES
CEILING
MOUNTED _ + MEZZANINE LIMITS
WALL NIC/ERO EQUIPMENT
WM MOUNTED
Project:
NEW DPW FACILITY
Y.
0„
C."
MATTACH 5.
H�oRPORNIVO (90
TOWN OF YARMOUTH, MA
507 BUCK ISLAND ROAD
YARMOUTH, MA 02673
Weston @sampso n
Weston & Sampson Engineers, Inc.
100 Foxborough Boulevard Suite 250
Foxborough, MA 02035
(508) 698-3034 (800) SAMPSON
www.westonandsampson.com
Consultants:
Seal:
c7` JAMcS
x >`okI
CIVIL y
No, 46434
'o?4At 1aG ;�
Revisions:
Rev Date Description
Issued For: BIDDING
PROJECT TRUE
SCALE: AS NOTED
Date: SEPTE:MBER,13 2019
Drawn By: TJC
Reviewed By: TJC
Approved By: JRF
Vi Project No: 2170117-E
Drawing Title:
EQUIPMENT
LAYOUT PLAN
MAINTENANCE
Sheet Number:
EQ1
01
e
W ESTON & SAMPSON COPYRIGHT 2019