Loading...
HomeMy WebLinkAbout29002.tif - BHDC-24-80 53295 1, 500 GALLON SEPTIC TANK (H-10)NOT TO SCALE OBSERVATION PORT ARC 36 CH AMBER AND DETAILS NOT TO SCALE NOT TO SCALE NOTES 7" HDPE VALVE BOX 1 q" RAISE AT LEAST ONE EXISTING COVER THREADED CAP 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. TO WITHIN 6" OF FINISHED GRADE INSTALLED — 2. SEPTIC TANK SHALL BE CAPABLE OF WITHSTANDING H-10 THE RISER SHALL BE 18" HDPE PIPE 3" MAX. LENGTH 60» LOADING. FINISH GRADE 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION CONC. COVER 6" MAX SHALL BE WATERTIGHT. EL. 9.0 4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK COVER. 0 BE" 9„ 5. FILL ALL UNUSED KNOCKOUTS WITH HYDRAULIC CEMENT. 'j— NOTE: i 4" O EL. 8.23 OBSERVATION PORT SHALL BE 10'-6" — a INSTALLED UTILIZING THE 4" SCH. 40 PVC KNOCKOUT ON THE TOP OF THE O PERFORATED PIPE SIDE VIEW 10'-0" ARC 36 CHAMBER AND SHALL SIDE PORT COUPLER 10" = EXTEND DOWN TO THE EXISTING SEE PLANFOR LOCATIONEOF OBSERVATIONWP RT. O 4 MIN. 4'-6" LOCATE QPTH LIUID 5,_8" H OF�jgs�9 INLET TEE o " �o YERGA7IAN Cr" I I BRIAN G. u> • 5'-8" I — _ _ UNDER COVER OUTLET TEE I W/GAS BAFFLE 3 I I 3 " 13 CIVIL y o PLAN VIEW CROSS—SECTION VIEW EXISTING SUBGRADE 7" ONAL POST END INVERT END CAP END CAP HEIGHT FRONT VIEW SIDE VIEW 05/08/2024 BRW G. YERGATIAN DATE PROFESSIONAL ENGINEER DISTRIBUTION BOX DETAIL (H-10). TYPICAL SECTION-UNREINFORCED RETAINING WALL INSPECTION SCHED SEPTIC SYSTEM NOT TO SCALE U LE NOT TO SCALE 6" MAX. DESIGN COVER 40 Mil POLY LINER REMOVABLE 1. ENGINEER SHALL INSPECT WHEN THE REQUIRED EXCAVATION IS COMPLETE. CAP UNIT ADHERES 2. ENGINEER SHALL LOCATE AND STAKE FOOTINGS (LOOSE STONE BED) PRIOR TO INSTALLATION. TO TOP UNIT 3. ENGINEER SHALL INSPECT FOOTING LOCATION PRIOR TO INSTALLATION OF WALL HDPE RISER W/VERSA—LOK COMMON BACKFILL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL WITH A PERCOLATION RATE OF LESS THAN TWO JCONCRETE ADHESIVE (2) MINUTES PER INCH HAS BEEN PROPERLY DEPOSITED. 29 PARKERS NECK ROAD 2" WALLS 3" �— 21" —� OR APPROVED EQUAL 5. ENGINEER SHALL INSPECT WHEN THE COMPONENTS OF THE SEPTIC SYSTEM AND THE PUMP MECHANISMS HAVE BEEN INSTALLED. .: r EL 8.0 IN w r •� ••- 9-1/2 MOSAIC \ \ \ \//\ \�` 0 0 13" (5) 5" DIA. ����\����\��\��\�������, SOUTH YARMOUTH KNOCKOUTS PANEL HEIGHT 10" / / / / / / 11-1/2" TYP. /\��/.\, MASSACHUSE17S VERSA—LOK OR ' .. . . . . •,.. . • •...s SELECT FILL MEETING (BARNSTABLE COUNTY) 2" BOTTOM ON LEVEL APPROVED EQUAL EUQNITS t ' THE REQUIREMENTS OF STABLE BASE 6 MINIMUM PLAN VIEW 310 CMR 15.255(3) 3/4- TO 1-1/2" (COBBLE, ACCENT AND ::t• SECTION VIEW CRUSHED STONE STANDARD UNITS) ' SITE PLAN NOTES: EL 4.7-5.9 ; 1. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 2. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL. VERSA—LOK OR APPROVED EQUAL -i I III I STANDARD UNIT (BASE COURSE) FEBRUARY 5, 2016 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. II III III- PAD 5. CONCRETE COVER SHALL BE RAISED TO WITHIN 6 INCHES OF FINISHED GRADE. MIN.GRANULAR LEVELINGTHICK ISIONS- NO. DATE DESC. 1 2/9/16 WALL DELINEATION 2 1/15/21 MODIFY DWELLING 3 5/7/24 ADDITIONAL TEST LOG TYPICAL SECTION-UNREINFORCED _RETAINING WALL NOT TO SCALE 40 Mil POLY LINER COMMON BACKFILL PREPARED FOR: PAUL BUTLER EL 8.0 \/\�\/\ 8 JESSIE'S LANE SOUTH YARMOUTH, MA 02664 CONCRETE UNITS OR pkbutler2002@yahoo.com APPROVED EQUAL a a '