HomeMy WebLinkAboutBLDE-23-004678 Please email cc�� permit to
j eastmapermits@sunrun.com
Commonweal o`/rlamaducutt� Official Use Only
Permit No. 023_q(p76
6, ..p i i _� — �LSepartment o f ire serviced
Occupancy and Fee Checked
'B•ARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
FEB 2APP TION FOR PERMIT TO PERFORM ELECTRICAL WORK
BUILDING l>LNARTMENTdd work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
By IN INK OR TYPE ALL INFORMATION) Date: 02/21/2023
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)8 Hawes Run Rd
Owner or Tenant Deborah Cotell Telephone No. (774)487-0998
Owner's Address 8 Hawes Run Rd Yarmouth MA 02673
Is this permit in conjunction with a building permit? Yes V No ❑ (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service 100 Amps / Volts Overhead V Undgrd n No.of Meters 1
New Service Amps / Volts Overhead ri Undgrd ❑ No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of a interconnected, roof mounted, photovoltaic solar. 11 solar panels at 4.29 Kw DC. NO ESS. NO STRUCTURAL.
Completion of the following table may be waived by the Inspector of Wires.
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No. n Detection and
I nitiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
g Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water No.of No.of Data Wiring:
Heaters KW Signs Ballasts No.of Devices or Equivalent
dromassa a Bathtubs 'No.of Motors Total HP Telecommunications Wiring:
No. H
Y g No.of Devices or Equivalent
OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $5646 (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al
Licensee: Nathan Ashe Signature /Lt. LIC.NO.:21136 A
(If applicable, enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519
Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978793-7881
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
Please email permit to eastmapermits@sunrun.com
..r°-_ Commonwealth of Official Use Only
Massachusetts Permit No. BLDE-23-004678
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/23/2023
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 8 HAWES RUN RD O
Owner or Tenant COTELL JOSEPH S JR Telep 4&
Owner's Address COTELL DEBORAH A, 8 HAWES RUN RD,WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check r . 'a • ,o3
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of
New Service Amps Volts Overhead 0 Undgrd 0 No.o
Number of Feeders and Ampacity &•?
Location and Nature of Proposed Electrical Work: Installation of solar PV system. (11 Panels 4.29 KW-DC)(NO ESS ,�
1
Completion of the following table may be waived y Lh€Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above 0 In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
((kJ1N C Lepi
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE# DESCRIPTION NV •SYSTEM SIZE:4290W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
PV-1.0 COVER SHEET L SERVICE ENTRANCE •MODULES:(11)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS.
PV-2.0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023.
MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,
PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023.
PV-4.0 ELECTRICAL
SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM PV PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
]AC I AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). �4�,P�'�NOE M4SS,'c
i ROBERT A. t.
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. s LADE
DC DISCONNECT(S) CIVIL H
•13.35 AMPS MODULE SHORT CIRCUIT CURRENT. No. 57978
Exp 6/30/20240
CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. EF+ -
•PV INSTALLATION CABBREVIATIONS CONTROLLED CONDUOCTORS MPLIES LOCATED INSIDE THE ARRAY BOUNDARYWITH THE NEC 2023 ARTICLE )ARE
INTERIOR EQUIPMENT LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION STAMPED 02/21/2023
A AMPERE L J SHOWN AS DASHED
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY s u n r u n
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT
#180120
(E) EXISTING FLUSH ATTIC VENT
VICINITY MAPMit
ESS ENERGY STORAGE SYSTEM PVC PIPE VENT _ ••MEEa srANDISR aLvn,TwNroN,MA.m7eo-7ai
AX11 0
FAX 11
EXT EXTERIOR METAL PIPE VENT
CUSTOMER RESIDENCE:
INr INTERIOR I.! DEBORAH COTELL
MSP MAIN SERVICE PANEL T-VENT i. r r 8 HAWES RUN RD,YARMOUTH,
(N) NEW SATELLITE DISH . • MA,02673
NTS NOT TO SCALE • TEL.(774)487-0998
oc ON CENTER FIRE SETBACKS i �, 00 ellif
APN:YARM-000054-000031
PREFAB PRE-FABRICATED I ® a. to PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT HARDSCAPE 8 Hawes Run r 4
223R-0O8COTE
PV PHOTOVOLTAIC �.,.• West Yimtouth,MA DESIGNER: (415)580-6920 ex3
RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE
TL TRANSFORMERLESS 02673.,United W
States AGATHE NISINGIZE
SCALE:NTS w
'M. TYPICAL SOLAR MODULES SHEET
V VOLTS pp REV NAME DATE COMMENTS COVER SHEET
W WATTS MEM= 7 __
Kalmu , _,J_ ,� REV.A 2/21/2023
LAN LANDSCAPE — ���- inif•e '
SNR MOUNT - .�1`BBiC == PAGE
POR PORTRAIT SNR MOUNT&SKIRT `� �V-�•O
!' iemplate_vern'on_4 0.ST
SITE PLAN-SCALE=3/64"=1.-0"
0
Ja
rMP
���ZH OF ibis
S
` o? ROBERT A. yG
g LADE
° , R u CIVIL ,7
,, 1. ` ...Exp�6ld0(10
23
., (E)RESIDENCE ✓`�••• r*
Y
STAMPED 02/21/2023
(N)ARRAY AR-01 4-
sunrun
#180120
695 MALES STANDISH BLw,TAUNTON,MA.02780,31
PHONED
FAX
CUSTOMER RESIDENCE:
DEBORAH COTELL
8 HAWES RUN RD,YARMOUTH,
MA,02673
ARRAY TRUE MAG PV AREA TEL.(774)487-0998
PITCH AZIM AZIM (SQFT) APN:YARM-000054-000031
AR-01 35° 143° 157° 227.6 PROJECT NUMBER:
223R-008COTE
DESIGNER: (415)580 6920 ex3
AGATHE NISINGIZWE
SHEET
SITE PLAN
REV:A 2/21/2023
PAGE PV-2.O
T.mp.h_v r lon_..0.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
g yp Detail OC Spacing Overhang OC Spacing Overhang Configuration
Span Spacing SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 10'-1" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREW
5/16":2.5"MIN.EMBEDMENT
D1-AR-01-SCALE:1/4"=1'-O"
AZIM:143°
PITCH:35°
1'-5' 23'-2" , —6'-4" -- ,
lit
1'-6" 1
t_j Eimi= =
02' ROBERT A. yo
•
LADE
1O-11" v CIVIL H
O No. 57978
iD Exp.6t30f2024
• •
i" T&
STAMPED 02/21/20, „. . o 11' sunrun
_,
#180120
,--_ 11'-7" - 1-2'-11"— 11'_7" ,-
-3'-5"----x 695 M 6TAND .TAUMGN,MA 01rBp.)3l1
PHONE
0 ISHBLVD
FARO
CUSTOMER RESIDENCE:
DEBORAH COTELL
8 HAWES RUN RD,YARMOUTH,
INSTALLERS SHALL NOTIFY ENGINEER OF ANY MA,02673
POTENTIAL STRUCTURAL ISSUES OBSERVED
PRIOR TO PROCEEDING W/INSTALLATION. TEL.(774)487-0998
APN:YARM-000054-000031
"IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" PROJECT NUMBER:
BOUNDARY REGION OF ANY ROOF PLANE 223R-008COTE
EDGES(EXCEPT VALLEYS),THEN
ATTACHMENTS NEED TO BE ADDED AND DESIGNER: (415)580-6920 ex3
OVERHANG REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS FOLLOWS: AGATHE NISINGIZWE
"ALLOWABLE ATTACHMENT SPACING SHEET
INDICATED ON PLANS TO BE REDUCED BY 50%. LAYOUT
"ALLOWABLE OVERHANG INDICATED ON
PLANS TO BE 1/5TH OF ALLOWABLE
SEE SITE PLAN FOR NORTH ARROW ATTACHMENT SPACING INDICATED ON PLANS. REV:A 2/21/2023
PAGE PV-3.0
remp'eh ve n 4.087
•
120/240 VAC
SINGLE PHASE
SERVICE
< OMETER#:
EVERSOURCE 1952248
UTILITY NOTE:TOTAL PV BACKFEED=31A
GRID' I USED FOR INTERCONNECTION
fSUPPLY SIDE TAP CALCULATIONS
O
(N)LOCKABLE
I EXISTING 100A BLADE TYPE (N)MA SMART
MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES:
1 DISCONNECT REVENUE 6E6000H-USSN
METER 6000 WATT INVERTER JUNCTION BOX PV MODULES
".---' O n n OR EQUIVALENT n TRINA SOLAR:TSM-390DE09C.07
EXISTING ) / Z
,� 125A MAIN ,f. i // (11)MODULES
< �� PANEL •`'� ® —IJI— _ a--e�' VI -w- JI _E/ OPTIMIZERS WIRED IN:
FACILITY -a 35A FUSES I I (1)SERIES OF(11)OPTIMIZERS
LOADS 1=
SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440
120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (2)10 AWG THHWTHWN-2 NONE (1)10 AWGN/THHTHWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
868 MYLES STENOIBM BLVD,TAUNTON,MA,02780.7331
PRONE 0
FASO
CUSTOMER RESIDENCE:
DEBORAH COTELL
8 HAWES RUN RD,YARMOUTH,
MA,02673
MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL(774)487-0998
TRINA SOLAR:TSM-390DE09C.07: 390 W MIN INPUT VOLTAGE: 8 VDC
OPEN CIRCUIT VOLTAGE: 40.8 V APN:YARM-000054-000031
MAX POWER VOLTAGE:: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
SHORT CIRCUIT CURRENT: 13.35 A MAX INPUT ISC: 14.5 ADC 223R-008COTE
MAX OUTPUT CURRENT: 15 ADC
DESIGNER: (415)580-8920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1 AGATHE NISINGIZWE
SYSTEM SIZE: 4290 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE: 480 V
SYSTEM OPERATING CURRENT: 11.29 A REV:A 2/21/2023
SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0
rsmpare_98,oo_4.0.87
AWARNING INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT"-- 110.21(8),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 890,OR
— -- - IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: aso VD(: •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2023:690.7(D) INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL OF APPLCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2023:690.13(B),
705.20(7),706.15(C)
AWARNING
DUAL POWER SUPPLY
SOURCES:UTILITY GRID rARNING:
PHOTOVOLTAIC
AND PV SOLAR ELECTRIC ! POWER SOURCE
SYSTEM
J LABEL LOCATION:
LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, CAUTION :
UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:890.31(D)(2)
AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS '
OVERCURRENT DEVICE
LABEL LOCATION.
LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN
ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC s u n r u n
OCPD OF APPLICABLE). 2018:1204.5.3
PER CODE(S):NEC 2023:705.12(B)(2)
4,
A WARNING #180120
SOLAR PV SYSTEM EQUIPPED - SOLAR PANELS
THIS EQUIPMENT FED BY 898 MYLES STANDISH BLYD,TAUNTON,MA 02780.7331
MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN ON ROOF `A 10NE
RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE:
SUPPLY OVERCURRENT DEVICE DEBORAH COTELL
SHALL NOT EXCEED AMPACITY OF 8 HAWES RUN RD,YARMOUTH,
BUSBAR MAIN PANEL (INT) MA,02673
LABEL LOCATION: TURN RAPID SHUTDOWN T �/
PV LOAD CENTER OF APPLICABLE)AND SWITCH TO THE"OFF" INVERTER (EXT)--II TEL.(774)487-0998
ANY PANEL THAT UTILIZES'THE SUM POSITION TO SHUT DOWN APN:YARM-000054-000031
PEROF REDK R S NECE023:705.12(B)(3)RULE". PV SYSTEM AND REDUCE PV PRODUCTION METER— PROJECT NUMBER:
1 SHOCK HAZARD IN THE SERVICE ENTRANCE 223R-008COTE
ARRAY. all FUSED AC DISCONNECT—
PV SYSTEM DISCONNECT DESIGNER: (415)580-8920 ex3
um
Ac OPERATING CURRF:NI :,s_oo AMPS 8 HAWES RUN RD, YARMOUTH, MA, 02673 AGATHENISINGIZWE
TING AC VOLTAGE _240 VAC 1_% , SHEET
LABEL LOCATION: PER CODE(S):NEC 2023 705.10(2) SIGNAGE
LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
INTERCONNECTION. ARE CONNECTED. REV:A 2/21/2023
PER CODE(S):NEC 2023:690.54, PER CODE(S):NEC 2023:890.12(D)
PAGE PV-5.0
rempate .rson a.087