HomeMy WebLinkAboutBLDE-23-000286 or 414 Commonwealth of Official Use Only
E` ► Massachusetts Permit No. BLDE-23-000286
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:7/19/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 216 HIGGINS CROWELL RD
Owner or Tenant NEVES RUYTER Telephone No.
Owner's Address 2 SHEFFIELD ROAD, WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (38 Panels 12.92 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW ,No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(II applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
NI-Or 4-1W 6117/1;)' ( (q. ijc11
eoucal (12)77,- 80A 11\,(16z1.-
t\I-1A t 7 ( vL
Commonwealth. �//// Official Use Only
❑� Commonwealth ol fI/asaac�ivaells � ��r�,. y-�
11.1 c� Permit No. ��//;0)
.Apartment o/ ire Services
42
L
Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
1,,,c1-
uala ' PPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
VZ All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
LIJ ASE PRINT IN INK OR TYPE ALL INFORMATION) Date: i-/LI -0G: m m City or Town of: Vet rmul-h To the Inspector of Wires:
his application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) �l I RC 8 '
Owner or Tenant \-e,r U Telephone No.339-f5''pia
Owner's Address rne, QS ()love
Is this permit in conjunction with a building permit? Yes No (Check Appropriate Box)
Purpose of Building -'11 I1 Utility Authorization No.
Existing Service / Amps ' /9y6 Volts Overhead � Undgrd n No.of Meters 1
New Service Amps / Volts Overhead I I Undgrd I I No.of Meters
Number of Feeders and Ampacity
Locati n and Nature of Proposed Electrical Work: 1 l C fr / I1/Q// ) Ut /Q7t 1 A'
Pl01OvO1lQiC SnIQ r Slem� I /`9, Ixl 3� pahG S
Completion of the followin&table may be waived by the Inspector of Wires.
No.
rano KVA
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of AlertingDevices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑
Connection Other
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KWNo.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated ValueA E e5rical Work: aaNaa)(When required by municipal policy.)
Work to Start: fi HH Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 3 BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the informati on this application is true and complete.
FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al
Licensee: Nathan Ashe Signature 4LIC.NO.:21136A
(Ifapplicable, enter "exempt"in the
Pp " "p license number line.) Bus.Tel.No.:978-594-3195
Address: 695 Myles Standish Blvd Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
l� 7
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:12920W DC,10000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES
•MODULES:(38)JA SOLAR:JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SE SERVICE ENTRANCE 1 PV-1.0 COVER SHEET
•INVERTERS (1)SOLAREDGE TECHNOLOGIES INSTRUCTIONS. - ° PV-2.0 SITE PLAN
SE10000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, MP MAIN PANEL PV-3.0 LAYOUT
SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV 4.0 ELECTRICAL
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY 0SUB-PANEL SNR MOUNT PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. SNR MOUNT 8 SKIRT
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT
AC
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). I AC DISCONNECT(S)
SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
E 1 DC DISCONNECT(S) FIRE SETBACKS
•10.46 AMPS MODULE SHORT CIRCUIT CURRENT.
•16.34 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&690.8(b)]. CB IQ COMBINER BOX . HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE I- INTERIOREQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE NTS
A AMPERE s u n r u n
AC ALTERNATING CURRENT
AFC' ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION #180120
, DC DIRECT CURRENT
'`' (E) EXISTING SOS MYLES STANDISH evvo,rAuwrorr,uA,0x)B0.)3x1
, Blue Roc ESS ENERGY STORAGE SYSTEM PHONE0
FAX 0
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
MAG MAGNETIC RUYTER NEVES
MSP MAIN SERVICE PANEL 216 HIGGINS CROWELL RD B,
(N) NEW YARMOUTH,MA,02673
e NTS NOT TO SCALE
OC ON CENTER TEL.(339)225-8812
0 PRE-FAB PRE-FABRICATED APN:YARM-000046-000060
. PSF POUNDS PER SQUARE FOOT PROJECT NUMBER:
1
PV PHOTOVOLTAIC 223R-216NEVE
RSD RAPID SHUTDOWN DEVICE
KEA!
_ `` TL TRANSFORMERLESS
TYP TYPICAL DESIGNER: (415)580-6920 ex3
V VOLTS HIMANI BISHT
Whydah Pirate F AI:;-r- .7 w WATTS
SHEET
IF 21 REV NAME DATE COMMENTS COVER SHEET
6VES - REV:A 7/8/2022
PAGE PV-1.0
I
IZ4y
m
m
m
z
z
cn
o
r
m
u
w
N
-I
O
Z
D
73
A
D
D
A
O
N
r \ * ± -
a D
A
O
Z l
\______________________:_
r m
SNI`JOIH v
9 N ll3MOb0 � S
�� z
M p
m
D
F
m
n\-------- __—-- D
m
n
1111111111111111 L.,
T I.
�
z
p II
m
CI;
m
0
m
z
g m D
N
y
a m i = m Np i� <"�2 , m TD
. < m Em WO >rncm o N N �x
m D D m D ta 3= H N y y n I.
zm _._, sN oo�; o C _<
CO y A cn bli2zz T $ , 3�
0
• Ill mm 3c�cn mm ' F m
IV D�mm w y
.71 p o, m N N 3
O 9 m cn Z m 30
Z Q o wm m 'e
r�S 8
N N co W m<
N G CO 4 N N na -n A
u -. m -1 m
D
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
Name Type Height Type Detail Configuration
Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 6'-6" 16" COMP,SEE DETAIL SNR-DC-00436 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 6'-6" 16" 2'-0" STAGGERED RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES:
• INSTALLERS SHALL NOTIFY
D1-AR-01-SCALE:3/16"=1'-0" .1,_2„ ENGINEER OF ANY POTENTIAL
AZIM:84* 1' 33'-2" , STRUCTURAL ISSUES
PITCH:27° OBSERVED PRIOR TO
PROCEEDING W/
1-0 INSTALLATION.
T.--- $ I • ARRAY(EX SK
IS WITHIN 12"BOUNDARY
srauci
oN REGION IF OF ANY ROOFCLUDING PLANE IRT)L EDGES(EXCEPT VALLEYS),�o���ytH oFAus'k THEN ATTACHMENTS NEED
VINCENT °� TO BE ADDED AND OVERHANG
4'TYP
MWUMVANEZA N REDUCED WITHIN THE 12"
CIVIL BOUNDARY REGION ONLY AS
N,/ 2 FOLLOWS:
e`�°N��e ••ALLOWABLE ATTACHMENT
*V ONALE�\ SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
IC) O O II O Q Q ••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
13'-3" - 6'-0" - --- • 13'-3"------ i ATTACHMENT SPACING
I I
INDICATED ON PLANS
D2-AR-02-SCALE:1/4"=1'-0"
PITCH:
27" •1' 33,_2„ sun r u n
,-6I
l ' I I l---- ❑ —El 1 I Q ❑ ❑ ❑-I
u16o120
MI5 MYLES STANDISN BLVD TAUNTON MA,02280-7./
FAX 0
I
CUSTOMER RESIDENCE:
I RUYTER NEVES
216 HIGGINS CROWELL RD B,
11'1" fl ❑ Q [ 6_..._.4'TYP.. _6 Q ❑ C ❑ YARMOUTH,MA,02673
TEL.(339)225-8812
APN:YARM-000046-000060
PROJECT NUMBER:
223R-216NEVE
I DESIGNER: (415)580-6920 ex3
n a o n Cl a a o o HIMANI BISHT
SHEET
2'7" LAYOUT
•
REV:A 7/8/2022
SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0
A
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
< O EVERSOURCE 2280954
UTILITY
GRID - I
SUPPLY SIDE TAP NOTE:TOTAL PV BACKFEED=53A
{I EXTERNAL DISCONNECT USED FOR INTERCONNECTION
. CALCULATIONS
EXISTING 100A (N)LOCKABLE
MAIN BREAKER BLADE TYPE (N)MA SMART SOLAREDGE TECHNOLOGIES:
DISCONNECT FUSED AC UTILITY SE10000H-USSN WITH
WITH 100A MAIN DISCONNECT REVENUE REVENUE GRADE METERING
ENCLSOURE METER 10000 WATT INVERTER JUNCTION BOX PV MODULES
(3` 3 ,2 OR EQUIVALENT JA SOLAR:JAM60S10-340/MR
1 �� . / (38)MODULES
EXISTING 100A o•o M -- H
_/• -}-- *(�j// OPTIMIZERS 1MRED IN:
MAIN BREAKER O V t (1)SERIES OF(13)OPTIMIZERS
I 60A FUSES I I (1)SERIES OF(13)OPTIMIZERS
*"."--N EXISTING
D 240V METER SOCKET LOAD RATED DC DISCONNECT (1)SERIES OF(12)OPTIMIZERS
EXISTING D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS
< 125A MAIN 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P370
PANEL 120I24OVAC CONNECTS TO TOP LUGS-
FACILITY (LINE AT TOP LOAD AT BOTTOM)
LOADS 1cn,
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
6.MYLES STANDISH BLVD.TAUNTON.MA,oneo-,,
PHONE
CUSTOMER RESIDENCE:
RUYTER NEVES
216 HIGGINS CROWELL RD B,
YARMOUTH,MA,02673
MODULE CHARACTERISTICS TEL.(339)225-8812
P370 OPTIMIZER CHARACTERISTICS:JA SOLAR:JAM6OS1O-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC AEN:YARM-000046-000060
OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC
SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT: 15 ADC 223R-216NEVE
DESIGNER: (415)580.6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1 HIMANI BISHT
SYSTEM SIZE: 12920 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 13 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 400 V
MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 7/8/2022
SYSTEM OPERATING CURRENT: 32.3 A
SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0
WARNING INVERTER 1 NOTES AND SPECIFICATIONS:
a,..:,,.-;:.;_s--_,,.,»..,,•._-<. •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535A-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
WARNING -1POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. - -- - -
LAND PV SOLAR ELECTRIC SYSTEM PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012:
605.11.1.4
LABEL LOCATION: CAUTION :
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S):NEC 2020:705.12(C)
AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS SOLAR PANELS ON ROOF
OVERCURRENT DEVICE LABEL LOCATION: -- — `N
INSTALLED WITHIN 3'OF RAPID SHUT DOWN
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012,605.11.1,IFC 2018,1204.5.3
OCPD(IF APPLICABLE).
PER CODE(S):NEC 2020: 4"
705.12(8)(3)(2)
1.
AWARNING SOLAR PV SYSTEM EQUIPPED :180120
0
PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN FM,��s.Nx,���w,,A �.�..�7N.»'
F
COMBINER PANEL PHONE,Vt
DO NOT ADD LOADS CUSTOMER RESIDENCE:
RUYTER NES
LABEL LOCATION: - 216 HIGGINSEV CROWELL RD B,
PHOTOVOLTAIC AC COMBINER(IF
APPUCABLE). ,. MAIN PANEL ',
3 YARMOUTH,MA,02673
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) TURN RAPID SHUTDOWN
SWITCH TO THE"OFF" w•. L: (INT) TEL.(339)225-8812
POSITION TO SHUT DOWN -- APN:YAR M-000046-000060
PV SYSTEM DISCONNECT ,, PV SYSTEM AND REDUCE `INVERTER (EXT) PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT 41.67 AMPS SHOCK HAZARD IN THE i223R-216NEVE
11
NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. . SERVICE --PRODUCTION METER
ENTRANCE ` FUSED AC DISCONNECT DESIGNER: (415)580-0820ax3
LAAC
LLONNECT( 216 HIGGINS CROWELL RD B, YARMOUTH, MA, 02673 HIMANIBISHT
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. _ SHEET
PER CODE(S):NEC 2020:690.54 LABEL
OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE
ON
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 7/8/2022
PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0