Loading...
HomeMy WebLinkAboutBLDE-23-004639 Commonwealth of Official Use Only Massachusetts Permit No. BLDE-23-004639 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT/N INK OR TYPE ALL INFORMATION) Date:2/22/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 11 ALIJO DR Owner or Tenant DEGREGORIO RICHARD A TR Telephone No. Owner's Address 11 ALIJO DR REALTY TRUST, 11 ALIJO DR, WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (20 Panels 7.8 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner ❑ owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Please email permit toeastmapermits@sunrun.com Commonwealth o////udac Official Use Only • - 7 --ems 6/ Permit No.2spartmani o`�ire Sarvicae �23 '1-�� _= '_ = Occupancy and Fee Checked fr= BOARD OF FIRE PREVENTION REGULATIONS Rev. 1/07] mt. (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 02/17/2023 City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street& Number) 11 Alijo Dr. Owner or Tenant Richard Degregorio Telephone No. (978) 828-0793 Owner's Address 11 Alijo Dr. Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead ❑ Undgrd VI No.of Meters New Service Amps / Volts Overhead ❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar. 20 solar panels at 7.8 Kw DC. NO ESS. NO STRUCTURAL. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf Tot Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* �Y No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No. H dromassa a Bathtubs No.of Motors Total HP Telecommunications NofDevices or Wiring: Y g No.of Devices Equivalent OTHER:20 Roof Mounted Solar Panels Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $10,265.00 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al iLi. Licensee: Nathan Ashe Signature LIC.NO.:21136 A (If applicable, enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978793-7881 *Per M.G.L. c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:7800W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SE SERVICE ENTRANCE •MODULES:(20)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE6000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:TOPSPEED,SEE DETAIL SNR-DC-30004 PV-3.0 LAYOUT •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL O. SUB-PANEL PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). O AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 2a��'�ZNOLMgsJ40 c ROBERT A. N •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. a LADE ODC DISCONNECT(S) CIVIL •13.35 AMPS MODULE SHORT CIRCUIT CURRENT, No. 57978 lb Exp.002024 ,? CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. , t*C'ev •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). ABBREVIATIONS 7 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE STAMPED 02 7'2023 A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT s u n r u n AFC ARC FAULT CIRCUITINTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (E) EXISTING FLUSH ATTIC VENT _ VICINITY MAP SOMVLES STAND.,BLVO,T�UINTON,MA,B]TB0.T3]1 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT '''r PHONE HO EXT EXTERIOR METAL PIPE VENT _ CUSTOMER RESIDENCE: INT INTERIOR •'I ' RICHARD DEGREGORIO MSP MAIN SERVICE PANEL T-VENT 11 ALIJO OR,YARMOUTH,MA, 02673 IN) NEW SATELLITE DISH NTS NOT TO SCALE TEL.(979)828-0793 OC ON CENTER FIRE SETBACKS ARM'YARM-000055-000004 PRE-FAB PRE-FABRICATED PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE QcaPe Cod Mall 223R-011DEGR Pv PHOTOVOLTAIC ', - 11 Alijo Drive— DESIGNER 415 580-6920 ex3 RED RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE ' IL TRANSFORMERLESS - ,---SOLAR MODULES \ryhyp3rl(',rate t,,1u;cJ'1', WILLIAM GRAYSON SCALE.NTS 28 SHEET V TYP VOLTSTYPICAL YA WEST H ® ,;'" REV NAME DATE COMMENTS COVER SHEET W WATTS Q REV:A 2/17/2023 LAN LANDSCAPE � A' _ POR PORTRAIT TOPSPEED MOUNT - `e 1 o .', ` PAGE PV-1.0 -` rempew_verson_a.0.87 SITE PLAN-SCALE=3/64"=1'-0" T INI PL 7 N MONTELLO ST#1 pt. _______ , ----'------ Pv pk. (E)GATE r . .•.... ... ; ..7:.:::.:. ....... �M . • . ,... • , ., (E)FENCE r ��''iHOFWSs9C , ' or ROLAD A. yc 1_, = UDE �, v CIVIL _ No. 57978 �..-. 4 \ .. 2�:sr�orzaza P 411, (E)RESIDENCE /fir 02 /l._7 STAMPED 0211712023' (N)ARRAY AR-01 sunrun ?, 11 #180120 606 MYLES STANOISE BLED,TAUNTON,MA,027.7331 PNONE0 FA%0 CUSTOMER RESIDENCE: RICHARD DEGREGORIO 0267311 ALIJO DR,YARMOUTH,MA, 7 PL ARRAY TRUE PV AREA PL �- PITCH AZIM (SQFT) TEL.(979)828-0793 R APN:YARM-000055-000004 ��� AR-01 31° 172° 413.9 a -- PROJECT2R-011DEGRER: DESIGNER: (415)580-6920 ex3 WILLIAM GRAYSON SHEET SITE PLAN REV:A 2/17/2023 PAGE PV-2.O T.IIIp110r_D*I 0M_4.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Minimum Number of Mounts per Up-Slope Max Landscape Max Portrait MAX DISTRIBUTED LOAD:3 PSF Span Spacing Edge Overhang Overhang SNOW LOAD:30 PSF WIND SPEED: AR-01 COMP SHINGLE- 1-Story 2X8 RAFTERS 8'-5" 16" TOPSPEED,SEE DETAIL SNR-DC-30004 3 1'-5" 0'-10" 140 MPH 3-SEC GUST. TOPSPEED S.S.LAG SCREW D1-AR-01-SCALE:1/8"=1'-0" (4)14 X 2.25"SS SEALING AZIM:172° WASHER WOOD SCREWS FULLY PITCH:31° PENETRATING THROUGH WOOD DECK INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/INSTALLATION. -MOUNT NUMBER FOR LEADING DOWNSLOPE EDGE SHALL MATCH REQUIREMENTS LISTED ABOVE INSTALL PER TOPSPEED" INSTALLATION MANUAL. -CONTRACTOR MAY SUBSTITUTE SNAPNRACK DECKTRACK MOUNTS(SNR DETAIL SNR-DC 00453)WITH A MAX OVERHANG OF 6" ��'NVH OF y,1 Ssic c ROBERT A. t. LADE CIVIL No. 57978 xp:6/302024 • 1 Ifrr / L r1,-2" STAMPED 02/17/2023 --0 0 0 1'8— ouo 000 000 000 7'-3" sunrun 3'-7" 0 0 0 0 0 0 0 0 0 --e-a -0----a 0 0 0 0 0 0 0 0 0 0 0 --0--0--0 #180120 8-11" o 0 o e o o 0 0 0 0 0 0 0 0 0 0 0 0 8 7 «eMOLES srn"o"a vo*w"a MA oz ad,»> PHONE 0 E.a 000 000 000 000 0 0 o CUSTOMER RESIDENCE. RICHARD DEGREGORIO 11 ALIJO DR,YARMOUTH,MA, 02673 12-11" 29' ITS' { TEL.(979)828-0793 APN:YARM-000055-000004 PROJECT NUMBER: 223R-011DEGR DESIGNER: (415)580.8920 ex3 WILLIAM GRAYSON SHEET LAYOUT REV A 2/17/2023 PAGE PV-3.0 SEE SITE PLAN FOR NORTH ARROW rempara_vervon_4 0 87 • 120/240 VAC SINGLE PHASE SERVICE METER#: < ® EVERSOURCE 2298717 UTILITY GRID SUPPLY SIDE TAP (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE6000H-USSN T 6000 WATT INVERTER JUNCTION BOX 3 METER 3 PV MODULES �\ OR EQUIVALENT TRINA SOLAR:TSM 390DE09C.07 EXISTING �� 100A MAIN �. + // (20)MODULES - ' PANEL `� 1• O •-•� -(lj/ OPTIMIZERS WIRED IN: (1)SERIES OF(10)OPTIMIZERS FACILITY -e '- 35A FUSES I Y ( (1)SERIES OF(10)OPTIMIZERS LOADS--Z SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 I 3/4"EMT OR EQUIV. (2)6 AWG THHWTHW W N-2 (1)8 AWG THHN/THWN-2 (1)8 AWGW THHN/THN-2 #180120 GOB MYIES STANDISH BLVD,r.WNTON,MA 027e0.7331 PIIONE O FAX 0 CUSTOMER RESIDENCE: RICHARD DEGREGORIO 11 ALIJO DR,YARMOUTH,MA, 02673 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TEL.(979)828-0793 TRINA SOLAR:TSM-390DE09C.07: 390 W APN:YARM-000055-000004 MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 223R-011DEGR SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 WILLIAM GRAYSON SYSTEM SIZE: 7800 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 10 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 2/17/2023 SYSTEM OPERATING CURRENT: 20.53 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.O Ar rempete_wrs0e e.O.67 ZWA R N I N G INVERTER 1 NOTES AND SPECIFICATIONS: "Mr •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD - - IF REQUESTED BY THE LOCAL AHJ. •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING MAXIMUM SYS I EM VOL 1 AGI-. 480 II TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) AWARNING DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC 1 POWER SOURCE SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, CAUTION : UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(0)(2) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THISrarmit, � OVERCURRENT DEVICE J �� `� LABEL LOCATION: LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN - ■ SOLAR PANELS ON ROOF ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:890.12(D)(2),IFC S u n r u n OCPD OF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(B)(2) , 4 A III WARNING SOLAR PV SYSTEM EQUIPPED u16o1zo THIS EQUIPMENT FED BY 695 MYLES STANOISH BLVD.TAUNTON MA 027e0-7331 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN V' FAX 0 PHONE RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE RICHARD DEGREGORIO SHALL NOT EXCEED AMPACITY OF MAIN PANEL (INT) 11 ALIJO DR,YARMOUTH,MA, BUSBAR 02673 LABEL LOCATION: 3 TURN RAPID SHUTDOWN PV LOAD CENTER(IF APPLICABLE)AND SWITCH TO THE"OFF' Pv rAHe�s TEL.(979)828-0793 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN SERVICE ENTRANCE APN:YARM-000055-000004 PEROF CODE(S):NEC0 PV SYSTEM AND REDUCE FUSED AC DISCONNECT PROJECT NUMBER: EC 2023:705.12(8)(3) SHOCK HAZARD IN THE INVERTER (EXT)— 223R-011 DEGR ARRAY. —PRODUCTION METER PV SYSTEM DISCONNECT DESIGNER: (415)580.8920 ex3 MAXIMUM ACOPFRATINGCURRFNT 25.00 AMPS I 11 ALIJO DR, YARMOUTH, MA, 02673 WILLIAM GRAYSON NOMINAL OPERATING AC VOLTAGE. _240_ VAC ` _ — SHEET LABEL LOCATION: PER CODE(S).NEC 2023:705.10(2) SIGNAGE LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV:A 2/17/2023 PER CODE(S):NEC 2023:890.54,CEC 2023:890.54 PER CODE(S):NEC 2023:890.12(D) 'PAGE PV-5.0 Ta0•t•_v8f on_4.0.8