Loading...
HomeMy WebLinkAboutBLDE-23-003673 0 t,t, Commonwealth of Official Use Only -1-1 Massachusetts Permit No. BLDE-23-003673 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.I/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:1/6/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 51 NOBBY LN Owner or Tenant DIANNE KAUFMAN Telephone No. Owner's Address 51 NOBBY LN,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(12 Panels 4.68 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER: I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement. I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 ei&C co 3/ z31z3 Please email permit to eastmapermits@sunrun.com * Commonwealth o/ 1 Massachusetts fficial Use Only r. _- C� �'// Permit No. �3-34 7 3 eLJepartment o�_7Ire �ervicei ----- Occupancy and Fee Checked Y-- +a BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: City or Town of: Yarmouth To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)51 Nobby Ln Owner or Tenant Dianne Kaufman Telephone No. (508)685-3474 Owner's Address 51 Nobby Ln Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service 100 Amps 120/240 Volts Overhead ® Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity 0 cijion and Nature of Proposed Electrical Work: ill cr., 1 s*!lotion of a interconnected,roof mounted,photovoltaic solar energy system consisting of 12 solar panels producing 4.68 Kw DC. NO ESS c j r4 I Completion of the followingtable may be waived by the Inspector of Wires. Z I No.of Total I..i to Mo.iaf Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Transformers KVA o Z !to.l.f Luminaire Outlets No.of Hot Tubs Generators KVA Q 114b.lu f Luminaires Swimming Pool Above ❑ In- 0 No.of Emergency cy Lighting (� grnd. grnd. Battery Units ce 1' Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones -No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. TotalTons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other. Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water Kam, No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Tel communicati No.of Devices or Equi valent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $6388 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of pedury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136 A • (If applicable,enter"exempt"in the license number line.) Busii. .Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd.Taunton.MA 02780 Alt.Tel.No.:978793-7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner ❑owner's agent. Owner/Agent I PERMIT FEE: $ Signature Telephone No. Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE N DESCRIPTION MI •SYSTEM SIZE:4680W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(12)TRINA SOLAR:TSAR-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE3800H-USMN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. Mp MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SP SUB•PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ACAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). 0 DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT 1690.8(A)&690.8(B)I. •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). ABBREVIATIONS E 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n r u n AFC ARC FAULT CIRCUIT INTERUPTER Z.._f CHIMNEY AZM AZIMITH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 IE/ EX*TING FLUSH ATTIC VENT VICINITY MAP en W IER SW..SUM.TAUNTOI,W.WO n31 ESS ENERGY STORAGE SYSTEM PVC PIPE VENT FAX 0 MOW EXT EXTERIOR SC METAL PIPE VENT CUSTOMER RESIDENCE: INT INTERIOR DIANNE KAUFMAN IMP MAIN SERVICE PANEL T-VENT 51 NOBBY LN,YARMOUTH,MA, SO NEW 1 SATELLITE DISH 02673 NTS NOT TO SCALE TEL.(774)454-6621 OC ON CENTER FIRE SETBACKS 51 Nobby DI, N: o • PREFAB PREFABRICATED West Yarmouth,MA..in, PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE 223R-051KAUF PV PHOTOVOLTAIC wT:r DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE """AO°TI' NAMANJAIN TL TRANSFORMERLESS SOLAR MODULES SCALE.NTS SHEET Tw TYPICAL REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS W WATTS REV:Al 1/3/2023 IAN LANDSCAPE - SNR MOUNT dibil :;e3 ill;;.REa.:h _Iq^flIe,A.,e PAGE PV-1.0 POR PORTRAIT SNR MOUNT F.SKIRT Tempra_wn +0W 4 SITE PLAN-SCALE=wee-1'-0" 0L (Y ®�AC LMI a 4 R . . : . .• \ a '' .i a ' / Nur Ab, LJ a a (N)ARRAY AR-01 s u n r u n (E)RESIDENCE (//// a #180120 0D6a wf 0 s s.nw x w n 56i w.TAUur .DA 0eo MI DAD CUSTOMER RESIDENCE: } DIANNE KAUFMAN 4„ 51 HOBBY LN,YARMOUTH,MA. 02673 TEL(774)454-8621 APN:YARM-000039-000240 PROJECT NUMBER: P. 223R-051KAUF R Nixy DESIGNER: (415)5804920.03 NAMAN JAIN SHEET SITE PLAN ARRAY TRUE MAG PV AREA REV Al 1/3I2023 PITCH AZIM AZIM (SOFT) AR-01 11° 223° 237° 248.3 PAGE PV-2.0 Tempre_wnan_4087 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait guration MAX DISTRIBUTED LOAD:3 PSF Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Confi SNOW LOAD:30 PSF WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 4X6 RAFTERS 11'-8" 32" RL UNIVERSAL,SPEEDSEAL TRACK ON 1" NA NA STAGGERED 140 MPH 3-SEC GUST. COMP,SEE DETAIL SNR-DC-00436 S.S.LAG SCREW 5/18":2.5"MIN.EMBEDMENT D1-AR-01•SCALE:1/4".1'-0" AZIM:223° PITCH:11' __._. 29' -- • • 5'-g„ ' ____ 11'8" _11,_7,. _. . 1'_7"•- • 1-2 _ -. _....- 0-- -0 , ❑ CI O T-3" -•_` • 5'-4"TYP : 10'-11" sunrun • � _ o 0 • • n o o #180120 aue ants 06w636"xw,*wulw,Mk 0211.6733, nwrE o U O O � - - — g.. CUSTOMER RESIDENCE: DIANNE KAUFMAN I 11'5" -- --. ---.--.. -- --- -------23'2"-- _ -------- 51 NOBBY LN.YARMOUTH,MA, 02673 TEL.(774)454.3621 INSTALLERS SHALL NOTIFY ENGINEER OF ANY APN:YARM-000039-000240 POTENTIAL STRUCTURAL ISSUES OBSERVED PROJECT NUMBER: STRUCT : PRIOR TO PROCEEDING W/INSTALLATION. 223R-051KAUF ONL Signed' •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" 4 1N—44,,4 01/03/2023 BOUNDARY REGION OF ANY ROOF PLANE EDGES DESIGNER: (415)580-6920 ex3 ��6 VINCENT �0, (EXCEPT VALLEYS),THEN ATTACHMENTS NEED NAMAN JAIN g MWUMVANEZA H TO BE ADDED AND OVERHANG REDUCED WITHIN SHEET CIVIL THE 12"BOUNDARY REGION ONLY AS FOLLOWS. LAYOUT N'• **ALLOWABLE ATTACHMENT SPACING '� aEa��e INDICATED ON PLANS TO BE REDUCED BY 50 '/''ONAI0C''' ••ALLOWABLE OVERHANG INDICATED ON PLANS REV:Al 1/3/2023 SEE SITE PLAN FOR NORTH ARROW TO SPABE 1/5TH OF ALLOWABLE CING INDICATED ON PLANS ATTACHMENT PAGE PV-3.0 ranpla.keno"_I.0.M 120240 VAC SINGLE PHASE SERVICE M O METER 1: EVERSOURCE 2793357 UTILITY GRID EXISTING 100A MAIN (i BREAKER DISCONNECT WITH 100A MAIN ENCLOSURE LOAD SIDE TAP Id I (N)LOCKABLE BLADE TYPE (N)MA SMART EXISTING 100A FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: MAIN BREAKER DISCONNECT REVENUE SE3800H-USMN © METER © 3800 WATT INVERTER JUNCTION BOX PV MODULES i\ © © OR EQUIVALENT 0 TRINA SOLAR:TSM-390DE09C.07 �� EXISTING 100A / (12)MODULES _-- MAIN PANEL ; e.o.. ; O ; II ✓• ; MI i rl��/ OPTIMIZERS WIRED IN. FACILITY 20A FUSES _ Yl.� (1)SERIES OF(12)OPTIMIZERS LOADS •o,Nu SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT D221NRB 100A CONTINUOUS WITH AFC!.RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R.30A UTILITY SIDE OF CIRCUIT COMPUANT S440 120240VAC CONNECTS TO TOP LUGS. TUNE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHWTHWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 SSS IIIMISTAra9nnw.TAUNT..W 027S67331 MOW o FAX CUSTOMER RESIDENCE: DIANNE KAUFMAN 51 NOBBY LN,YARMOUTH,MA, 02673 MODULE CHARACTERISTICS g440 OPTIMIZER CHARACTERISTICS: TEL.(774)454-6621 TRINA SOLAR:TSM-3900E09C.07: 390 W MIN INPUT VOLTAGE 8 VDC APR YARM-000039-000240 OPEN CIRCUIT VOLTAGE 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V SHORT CIRCUIT CURRENT: 13.35 A MAX INPUT ISC: 14.5 ADC 223R-051KAUF MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-8920 ex3 NAMAN JAIN SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 4680 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:Al 1/3I202 SYSTEM OPERATING CURRENT: 12.32 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV_4.0 I�,Pleb vSFam 4.0.8T AWARNING4 NVLRTER I IPHOTOVOLTAIC NOTES AND SPECIFICATIONSELECTRICAL SHOCK HAZARD DC DISCONNECT •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE _....._ 110.21(B).UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690 OR IMUM SYSTEM VOLTAGE. 480 ',DC IF REQUESTED BY THE LOCAL AHJ. TERMINALS ON LINE AND LOAD •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE SIDES MAY BE ENERGIZED IN LABEL LOCATION WORDS,COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION INVERTERS),DC DISCONNECTS) METHOD AND SHALL NOT BE HAND WRITTEN. PER CODE(S).NEC 2020.690.53 •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT LABEL LOCATION. INVOLVED. INVERTER(S).AC/DC DISCONNECT(S). •SIGNS AND LABELS SHALL COMPLY WITH ANSI 2535.4-2011.PRODUCT SAFETY AC COMBINER PANEL(IF APPLICABLE). SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. PER CODE(S):NEC 2020 890.13(13) •DO NOT COVER EXISTING MANUFACTURER LABELS WARNING:PHOTOVOLTAIC --wwf i' POWER SOURCE LABEL LOCATION: • INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN.ABOVE AND BELOW PENETRATIONS, ON EVERY JBPULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S)NEC 2020 690 31(0)(2).IFC 2012. SYSTEM 60511 1 e LOCATION. CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODES)NEC 2020:70512(C) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF '�� DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION. _ INSTALLED R COD( ):NECSHUT DOWN s u n r u n LABEL LOCATION. SWITCH PER CODE(S), C 2020 890.58(C)(2),IFC ADJACENT TO PV BREAKER AND ESS 2012:608.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: 4' 705.12(BX352) SOLAR PV SYSTEM EQUIPPED 1 n160,20 PHOTOVOLTAIC SYSTEM MAIN N�BLVD.uNrw u .w.Snwm+ COMBINER PANEL WITH RAPID SHUTDOWN PANEL(INT) `�`° DO NOT ADD LOADS CUANNEOMSTEKAUFMANR RESIDENCE: DI LABEL LOCATION: 51 HOBBY LN,YARMOUTH,MA, PHOTOVOLTAIC AC COMBINER(IF 02873 APPUCABLE) TURN RAPID SHUTDOWN PERCOOE)S R CODE(S)NEC 2020 705 12(D)(2X3)(c) SWITCH TO THE"OFF" SOLAR IOACTW SERVICE ENTRANCE TEL.(774)454-6621 POSITION TO SHUT DOWN APN.YARM-000039-000240 tAxtPV SYSTEM DISCONNECT PV SYSTEM AND REDUCE FUSED AC DISCONNECT PROJECT NUMBER: MUM AC OPERATING CURRENT:16.00 AMPS SHOCK HAZARD IN THE PV PRODUCTION METER 223R-051KAUF _tNOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. II —INVERTER(EXT) DESIGNER: )415)5806920 e1c3 LABEL LOCATION. 51 NOBBY LN, YARMOUTH, MA, 02673 NAMAN JAIN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF �� SHEET INTERCONNECTION. LABEL LOCATION: SIGNAGE PER CODE(S):NEC 2020-690.54 PER CODE(S):NEC 2020:706.10,710.10 ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:Al 1/32023 PER CODE(S).NEC 2020.690.56(C) PAGE PV-5.0 T•nplair rimn_4.0.81