Loading...
HomeMy WebLinkAboutBLDE-23-002132 Commonwealth of Official Use Only i. Massachusetts Permit No. BLDE-23-002132 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/20/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 27 EMERALD ST Owner or Tenant GLADYSHEVA TATIANA Telephone No. Owner's Address GLADYSHEV SERGE!, 16 DOANE RD, MEDFORD, MA 02155-1337 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (14 Panels 4.970 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature 1 Telephone No. PERMIT FEE: $150.00 �` I2/(0(2)7vd I` —' -- .., _ pC.r 2Q ri \ \ _.,;,, -,— l,ommontveal/h O`///aeeachitdeth Official Use Only nlN =* c� c� 1,3—2—2-- BU1L ll+-4 -- Permit No. j 1JeParlmertt o` fire�ewice9 JE slaw_;; Occupancy and Fee Checked O '= BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) .wM_ `, APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: r o / i a 1 a a 0 City or Town of: YQ(MOO#—V1 To the Inspector of Wires: S By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) al eraser(L1(i Akte, Owner or Tenant 5,Q,"r3.6 ("l� � �/ Telephone No. 7 ', 6�'�,')�,J L4 Owner's Address Spa t1Y .L ` Is this permit in conjunction with a building permit? l es LP-1 No ❑ (Check Appropriate Box) r Purpose of Building Utility Authorization No. Existing Service` "' Amps lb /N o Volts Overhead © Undgrd❑ No.of Meters E. New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: incrvill('G rn 6( @.Pl 1(t.\QA Conn acAtj C2- etc cm s S xn ILA va_viQ.ts t-i. 4 7 61h V Completion of the followin_ table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Sus .(Paddle)Fans No.of Total P Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.of Emergency Lighting No.of Luminaires Swimming Pool grnd. ❑ grnd. ❑ Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No. Initiatingof Deteon and Devices g. No.of Ranges No.of Air Cond. TotalTons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained P Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal Connection ❑ Other E No.of Dryers Heating Appliances KW' Security Systems:' rY No.of Devices or Equivalent No.of Water Kam, No.of No.of Data Wiring: Oj Heaters Signs Ballasts No.of Devices or Equivalent Q Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: , No.H y g No.of Devices or Equivalent OTHER: G Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (pfi 8`) .pv (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. 0 CHECK ONE: INSURANCE ® BOND ❑ OTHER El (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature11( LIC.NO.:21136A 0- (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)El owner ❑owner's agent. Owner/Agent I PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:4970W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), rift SOLAR MODULES •MODULES:(14)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-60HPB-355M INSTRUCTIONS. L � ,, — $— PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. I SE3800H-USS3 MP MAIN PANEL j ■ PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER i',-11 CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 1 \ ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER ( i FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ai METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). Q AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC 1---1 DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. • •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX -, HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(8)(2). `---- CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE EINTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE s u n r u n AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION -- — — -- DC DIRECT CURRENT #180120 (E) EXISTING 695 MOLES STANDISH BLVD,TAUNTON MA 02780,7331 ESS ENERGY STORAGE SYSTEM PHONE FAA 0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC SERGEI GLADYSHEV MSP MAIN SERVICE PANEL 27 EMERALD AVE,YARMOUTH, (N) NEW MA,02673 NTS NOT TO SCALE OC ON CENTER TEL.(781)572-2054 PRE-FAB PRE-FABRICATED APN:YARM-000022-000174 PSF POUNDS PER SQUARE FOOT ctl PV PHOTOVOLTAIC PROJECT NUMBER: RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS VOLTS DESIGNER: (415)5808920 ex3 V V TYP TYPICAL MATTHEW ZEIGER W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET - REV:A 10/19/2022 PAGE PV-1.0 SITE PLAN-SCALE=3184"=1'-0" ARRAY TRUE MAG PV AREAPITCH AZIM AZIM (SOFT) I� AR-01 25° 202° 216° 196.1 �� AR-02 26° 112' 125° 78.4 5' � R k Pc -----------7 . (N)ARRAY AR-02-- ° O PM INV (E)GATE• MP SE / / 141%lp,' cr •;•• sunrun C. c ___... �— (E)RESIDENCE #180120 \\� 895 MYLES STANDISH BLVD,TAUNTON,MA,027807331 ./ ,,, ________ GMOHE0 \ FANO Pt (N)ARRAY AR-01 CUSTOMER RESIDENCE: \ 27EME L V EMERALD AVE.AVE,YARMOUTH, MA,02673 Pt \ --(E)FENCE TEL.(YAR YARM- 54 000022-000174 APN:YARM-000022-000174 tt PROJECT NUMBER: 223R-027GLAD DESIGNER: (415)580-6920 ex3 MATTHEW ZEIGER SHEET SITE PLAN REV:A 10/19/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Configuration Span Spacing Detail OC Spacing Overhang OC Spacing Overhang guration SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 13'-0" 16" COMP,SEE DETAIL SNR-DC-00436 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'- 16,. RL UNIVERSAL,SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16":2.5"MIN EMBEDMENT 11" COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:202° 30.8" t STRUCTURAL ISSUES PITCH:25° OBSERVED PRIOR TO PROCEEDING W/ 20'-5" _._... 6'-10" •2'-1" INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) — - IS WITHIN 12"BOUNDARY • 1-6 REGION OF ANY ROOF PLANE j -1 . EDGES(EXCEPT VALLEYS), THEN ATTACHMENTS NEED Li I:1 TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" eir = 11'-7" BOUNDARY REGION ONLY AS STRUCT FOLLOWS: oNL ••ALLOWABLE ATTACHMENT ��ytH OF Mggs9c ��� VINCENT y6N ❑ SPACING INDICATED ON .MWUMVANEZA N 11111 Milli i PLANS TO BE REDUCED BY CIVIL 1'-10" 50% Ni. ••ALLOWABLE OVERHANG n/ J//.10 tQ INDICATED ON PLANS TO BE WABLE �' ONRLEH�\�� ATTAC1/5TH HMENT F OSPACING INDICATED ON PLANS D2-AR-02-SCALE:3/16"=1'-0" AZIM:112° sunrun PITCH:26° 8'-7" 13'-10" 2' #180120 1'6" 6.MYLES STANDISH$VD.TAUNTON Mn 027M)7311 NE 0 ❑ ❑ 0 C 0 FAX I CUSTOMER RESIDENCE: SERGEI GLADYSHEV 5'9" 27 EMERALD AVE,YARMOUTH, - 4'TYP-- ' MA,02673 A I l 0 . TEL.(781)572-2054 I APN:YARM-000022-000174 3.-4" PROJECT NUMBER: 223R-027GLAD DESIGNER: (415)580-6920 ex3 MATTHEW ZEIGER SHEET LAYOUT 5" REV:A 10/19/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 1+ i 1 ) 120/240 VAC SINGLE PHASE SERVICE METER#: O EVERSOURCE 2283399 UTILITY GRID 1 EXISTING 200A MAIN BREAKER l DISCONNECT 1 WITH 200A MAIN ENCLOSURE • EXISTING (N)MA SMART < • 225A (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES: �� MAIN BLADE TYPE REVENUE SE3800H-USS3 FACILITY LOA S —' PANELC3 AC DISCONNECT(3) METER 3� 3800 WATT INVERTER JUNCTION BOX PV MODULES DISCONNECT( \2) OR EQUIVALENT Ci LONGI GREEN ENERGY TECHNOLOGY r A n / CO LTD:LR4-60HPB-355M �. M _ �� * �/ (14)MODULES � O �' - OPTIMIZERS WIRED IN: AauTr I I (1)SERIES OF(14)OPTIMIZERS (N)20A -.1. o SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT PV BREAKER AT DU221RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 sun ru n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHWTHWN-2 #180120 BBS MYLES STANDISH BLVD,TAUNTON,MA,01780.7331 PHONED FAX CUSTOMER RESIDENCE: SERGEI GLADYSHEV 27 EMERALD AVE,YARMOUTH, MA,02673 MODULE CHARACTERISTICS TEL.(781)572-2054 P401 OPTIMIZER CHARACTERISTICS: LONGI GREEN ENERGY APN:YARM-000022-000174 MIN INPUT VOLTAGE: 8 VDC TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 22 ER: R 027GLAD OPEN CIRCUIT VOLTAGE. 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.25 A MATTHEW ZEIGER SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 4970 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE 480 V REV A 10/19/2022 SYSTEM OPERATING CURRENT: 13.08 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE Pv-4.o , .-a /\WA RN I NG INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE ae6 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION. METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWA .".n. POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC I PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 CAUTION . LABEL LOCATION: UTILITY SERVICE METER AND MAIN ■ SERVICE PANEL. PER AWARNING NEC 2020:705.12(C) MULTIPLE SOURCES OF POWER APID SHUTDOWN SWITCH POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM SOLAR PANELS ON ROOF--- 0,11DO NOT RELOCATE THIS OVERCURRENTDEVICE J LABEL LOCATION: MAIN PANEL AND PV BREAKER II INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2),IFC DISCONNECT (I N T) s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 — OCPD(IF APPLICABLE). PER CODE(S):NEC 2020: a" , SERVICE ENTRANCE— I 705.12(B)(3)(2) �I AC DISCONNECT _ ateotzo AWA SOLAR PV SYSTEM EQUIPPED PV PRODUCTION METER �� #16.10120ES �ew.,.U���.o„� , PHOTOVOLTAIC WITH RAPID SHUTDOWN INVERTER (EXT) " ' ° COMBINER PANEL "` DO NOT ADD LOADS CUSTOMER RESIDENCE: SERGE)GLADYSHEV LABEL LOCATION: 27 EMERALD AVE,YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF APPLICABLE). MA,02673 PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 1 TURN RAPID SHUTDOWN SWITCH TO THE"OFF" TEL.(781)572-2054 POSITION TO SHUT DOWN APN:YARM-000022-000174 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:15.83 AMPS SHOCK HAZARD IN THE ARRAY. 223R-027GLAD NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: 27 EMERALD AVE, YARMOUTH, MA, 02673 MATTHEWZEIGER AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. - -- SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION. ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020 705.10.71010 WAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 10/19/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 1 I.