HomeMy WebLinkAboutBLDE-23-004547 Commonwealth of Official Use Only fE:.. Massachusetts Permit No. BLDE-23-004547 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked JRev.1/071 APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:2/15/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 66 RITA AVE Owner or Tenant TOWERS DANIEL W Telephone No. Owner's Address TOWERS GRETCHEN E, 66 RITA AVE, SOUTH YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (33 Panels 12.870 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total ,Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons _ KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND ❑ OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement. I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 RECEIVEDLA aa' eommoruveattI of MaiJachaieth Official Use Orly__ FEB 7 t '. 2epartment o`.lire Serviced Permit No. L---L�� - Occupancy and Fee Checked BUILDING `�ENTBOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07 By: _.,' (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 C'MR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: o a / 13 I a-) City or Town of: yar fl1ouw�r, To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street& Number) if& E i+a A,A__Owner or Tenant non 1 cl Tow Telephone No.' 7 1 a 8BO 5OO Owner's Address 5anAR az �N J..t Is this permit in conjunction with a building permit? Yes ❑ No n (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing ServiceaU() Amps lap, ayDVolts Overhead X Undgrd n No.of Meters New Service Amps / Volts Overhead n Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: i n3.i.411 a+i o'i Orcul I Yi*G(Co Yme c4. rcxrto f P✓ 51 a A.yi 33 earl S I a . s-76 vi Completion of the following table may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW rity Systems:* No.of Devices or Equivalent No.of Water KW 'No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No. Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: I_ Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: 11I�3�. 60 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC. NO.:4316 Al Licensee: Nathan Ashe Signature 7,4_, LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel. No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L. c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑ owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE N DESCRIPTION F •SYSTEM SIZE:12870W DC,10000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(33)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET Ng •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE10000H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). OAC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 0 DC DISCONNECT(S) •13.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •20.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)). •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2). ABBREVIATIONS E 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n r u n AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT (E) EXISTING FLUSH ATTIC VENT VICINITY MAP #180120 PHONNE o s STANQIeH txw,TAUNT.,MA,onea.7J], ESS ENERGY STORAGE SYSTEM : y' PVC PIPE VENT . ri: a EXT EXTERIOR ___ s; METAL PIPE VENT '/' — 1111 INT INTERIOR 1( y' CUSTOMER RESIDENCE: MSP MAIN SERVICE PANEL N T-VENT 4F Cilrfk, DANIEL TOWERS "'rw� $,. 66 RITA AVE,YARMOUTH,MA, (N) NEW '�' s 02664 SATELLITE DISH NTS NOT TO SCALE oes Path C TEL.(774)238-0500 OC ON CENTER FIRE SETBACKS `i• r,,,„, APN:YARM-000089-000182 PRE-FAB PRE-FABRICATED PROJECT NUMBER: — PSF POUNDS PER SQUARE FOOT Old TOW(I House RA HARDSCAPE ♦ 223R-066TOW1 PV PHOTOVOLTAIC DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE 66 Rita South n TRANSFORMERLESS SOLAR MODULES I JORGE ELIAS SCALE:NTS Ave.Yaouth,MA e'er SHEET u -- — iir266rm TYP TYPICAL --�-a-- -- -- 04,United States a COVER SHEET REV NAME DATE COMMENTS ✓ VOLTS ,10111111' W WATTS ! LAN LANDSCAPE --II._. ___-.n _-.. ..a o . South Yarmouth — REV:A 2/10/2023 • --SNR MOUNT PAGE POR PORTRAIT l i---SNR MOUNT&SKIRT _ 1.Q, E .,g i'West DennisPV-'I.O rempate_v ,,a 0.87 SITE_\PLAN-SCALE=1/16"=1'-0" 1'�1T (N)ARRAY AR-02--1 (N)ARRAY AR-01 --' (E)FENCE---- Pt . PL -------------" PL ------------\ Pt 0_,--_- --••• (E)DETACHED \-------- • g STRUCTURE . __ I .,, • M SIB1 ( RESIDENCE \\ E> \ .: rz 1, 1 \ W sunrun a a r K #180120 \ , i Cyr 595 MULES STA0 SH BLVD,TAUNTON,Mn 02730-MIPHONED SE ACPM INV No CUSTOMER RESIDENCE: • DANIEL TOWERS P 66 RITA AVE,YARMOUTH,MA, L__ PL -------------------ir F.,_ 02664 P� - Pi TEL.(774)238-0500 ARRAY TRUE MAG PV AREA APN:YARM-000089-000162 PITCH AZIM AZIM (SOFT) PROJECT NUMBER: AR-01 40° 261° 275° 413.9 223R-066TOW1 (E)GATE AR-02 27° 81° 95' 269 DESIGNER: (415)580-6920 ex3 JORGE ELIAS SHEET SITE PLAN REV:A 2/10/2023 PAGE PV-Z.O T.mp.n waon_4.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 5'-0" 16" COMP,SEE DETAIL SNR-DC-00436 -0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW RL UNIVERSAL,SPEEDSEAL TRACK ON 5/16":2.5"MIN.EMBEDMENT AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 11'-6" 16" COMP,SEE DETAIL SNR-DC-00436 -0" 2'-0" STAGGERED D1-AR-01-SCALE:3/16"=1'-0" AZIM:261° PITCH:40° .� _. _.-- -29'__.._. __. _.__.. _...... , r 1,_7„ 1 2,_9., • ❑ ❑ ❑ I-I 11 f1 iI .--H-4-.. o ❑ ❑ if it ❑ 0STRUCT ; • ONL I i i i 14,-7„ �' VI::: y�� o MWUMVANEZA N CIVIL ❑ ❑ - (I it ii I it i, 9'•,%J:. - 7 Signed:02/10/2023 Q``ONALEV'. 5'-4"TYP • 0 O 0 ( 0 0 0 0 sunrun D2-AR-02-SCALE:3/16"=1'-0" AZIM:81° , 7' • 23.-2" • ,1'-11" PITCH:27° #180120 • .\... ♦ 995 MYLES STANDISH BLVD.TAUNTON.MA.02790.7331 '� _._1'6° PHONE CI 0 ❑ 0 0 0 - FAA O INSTALLERS SHALL NOTIFY ENGINEER OF ANY 5,2„ • CUSTOMER RESIDENCE: POTENTIAL STRUCTURAL ISSUES OBSERVED DANIEL TOWERS PRIOR TO PROCEEDING W/INSTALLATION. ❑ ❑ ❑ -_.____.__.Q. O ❑ ❑ ❑ 66 RITA AVE,YARMOUTH,MA, 02664 IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE • 10'-11" TEL.(774)238-0500 EDGES(EXCEPT VALLEYS),THEN APN:YARM-000089-000162 ATTACHMENTS NEED TO BE ADDED AND 7'�3„ p ❑ 1 ❑ ❑ 0 0 0 0 - ❑ i PROJECT NUMBER: OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: .�- 5'-4"TYP j 223R-OB6TOW1 ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. d ° )� b Q . DESIGNER: (415)580-6920 ex3 . __-. JORGE ELIAS ••ALLOWABLE OVERHANG INDICATED ON L. PLANS TO BE 1/5TH OF ALLOWABLE SHEET ATTACHMENT SPACING INDICATED ON PLANS. LAYOUT REV:A 2/10/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 r,„..r.,...,_ao.er -t t • 120/240 VAC SINGLE PHASE SERVICE METER#: NOTE:TOTAL PV BACKFEED=53A O EVERSOURCE 2362798 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID I I� SUPPLY SIDE TAP (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: 1 DISCONNECT METERVUE SE10000H-USSN 10000 WATT INVERTER JUNCTION BOX PV MODULES (3 j (3) (2) OR EQUIVALENT (i) TRINA SOLAR:TSM-390DE09C.07 EXISTING �� 100A MAIN ° i1 ,_/� h n +(�)// (33)MODULES RED IN: PANEL �� I) 0 �� U " - Y / ((11))SERIES OF PTIMIZERS (111)OPTIMIZERS FACILITY 60A FUSES -I e ) (1)SERIES OF(11)OPTIMIZERS LOADS-.1.«o No SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(11)OPTIMIZERS SOLAREDGE D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (6)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (6)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 680 MYLES STANOISN.VD.TAUNTON,MA,0 278 613 31 PHONE 0 FAX O CUSTOMER RESIDENCE: DANIEL TOWERS 66 RITA AVE,YARMOUTH,MA, 02664 MODULE CHARACTERISTICS TEL.(774)238-0500 S440 OPTIMIZER CHARACTERISTICS: TRINA SOLAR:TSM-390DE09C.07: 390 W APN:YARM-000089-000162 MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 223R-066TOW1 SHORT CIRCUIT CURRENT: 13.35 A MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 JORGE ELIAS SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 12870 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 11 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 2/10/2023 SYSTEM OPERATING CURRENT: 32.17 A SYSTEM SHORT CIRCUIT CURRENT: 45 A PAGE PV-4.0 Temp'ate_ s n_00.87 QVAI„w RNi INVERTER1 NOTES AND SPECIFICATIONS: - _ - •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCALAHJ. MAXIMUM SYSTEM VOLTAGE 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY LABEL LOCATION: INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) AWARNING DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE -- -- — --- — _ -- SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, UTILITY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS, CAUTION : SERVICE PANEL. ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023,705.30(C) PER CODE(S):NEC 2023:690.31(0)(2) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECT SOLAR PANELS ON ROOF P. FOR SOLAR PV SYSTEMIlk p DO NOT RELOCATE THIS ___ __� OVERCURRENT DEVICE LABEL LOCATION: LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC S u n r u n OCPD(IF APPLICABLE). 2018:1204.5.3 • PER CODE(S):NEC 2023:705.12(B)(2) 4" • A WARNING SOLAR PV SYSTEM EQUIPPED #180120 THIS EQUIPMENTIPMENT .TOTED WITH RAPID SHUTDOWNif: oss*uJoise eLvo,Tnumonl,Me,oneo-na( MULTIPLE SOURCES.TOTAL (I- � Faxo RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN L CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE INVERTER (EXT) DANIEL TOWERS SHALL NOT EXCEED AMPACITY OF PRODUCTION METER 66 RITA AVE,YARMOUTH,MA, LABEL LOCATION:BUSBAR - TURN RAPID SHUTDOWN —FUSED AC DISCONNECT 02664 PV LOAD CENTER(IF APPLICABLE)AND SWITCH TO THE"OFF" LAR wLEG R ess`s —SERVICE ENTRANCE TEL.(774)238-0500 ANY PANEL THAT UTILIZES'THE SUM POSITION TO SHUT DOWN APN:VARM-000089.000162 OF BREAKERS RULE". PV SYSTEM AND REDUCE PROJECT NUMBER: 11111 PER CODE(S):NEC 2023:705.12(B)(3) sHOCK HAZARD IN THE -MAIN PANEL(I N T) 223R-O66TOW1 ARRAY. PV SYSTEM DISCONNECT DESIGNER: (415)580-6920 ex3 MAXIMUM AC OPERATING CURRENT 42.00 AMPS 66 RITA AVE, YARMOUTH, MA, 02664 JORGE ELIAS NOMINAL OPERATING AC VOLTAGE: 240 VAC ` - — -- SHEET LABEL LOCATION. PER CODE(S):NEC 2023:705.10(2) S I G NAG E LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV:A 2/10/2023 PER CODE(S):NEC 2023:690.54. PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 Templa(e_vervor,0 08? I! /.