HomeMy WebLinkAboutBLDE-23-001200 � -\ Commonwealth of Official Use Only
�E Massachusetts
Permit No. BLDE-23-001200
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/5/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 51 LUMBERJACK TRAIL
Owner or Tenant ADRIANA NASCIMENTO Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (No information submitted)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
Ga c I(/71Z1 '
RECE1VEC
rti commonwealth. Official Use Only
SEn o a99ac u9effa
'{_} '`,� c� Permit No.
a '' _, .2 eparfinenf ol ire �ervice9
BUILDING .e=_any==,' - Occupancy and Fee Checked
By ____—' = SARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:
City or Town of: To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)
Owner or Tenant Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes ❑ No ❑ (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps 120 / 240 Volts Overhead ❑ Undgrd❑ No.of Meters
New Service Amps / Volts Overhead❑ Undgrd n No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Completion of the following table may be waived by the Inspector of Wires.
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
i
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
of
No.of Switches No.of Gas Burners No. Initiatinnggon Dete and
In Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
g Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other
P Connection
No.of Dryers Heating Appliances KW Security Systems:*
rY No.of Devices or Equivalent
No.of Water No.of No.of Data Wiring:
Heaters KW Signs Ballasts No.of Devices or Equivalent
No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring:
Y g No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services LIC.N0.:4316 Al
Licensee: Nathan Ashe Signature 7�4.-- LIC.NO.:21136A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519
Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my; ignature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent 78785943519 PERMIT FEE: $
Signature Telephone No.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OFCONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:9940W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBCIIEBC), W SOLAR MODULES PV-1.0 COVER SHEET
•MODULES:(28)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SERVICE ENTRANCE
LTD:LR4-6OHPB-355M INSTRUCTIONS. PV-2.0 SITE PLAN
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-3.0 LAYOUT
SE7600H-USSN MP MAIN PANEL — —
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. —0 n PV-4.0 ELECTRICAL
SEE DETAIL SNR-DC-00436 - SNR MOUNT PV-5.0 SIGNAGE
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LAATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER _ FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) x METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). -. T-VENT
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S)
� 7 SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
r, DC DISCONNECT(S) FIRE SETBACKS
•11.25 AMPS MODULE SHORT CIRCUIT CURRENT.
•17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE E INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION SHOWN AS DASHED
L J SCALE:NTS
A AMPERE sunrun
AC ALTERNATING CURRENT
AFC! ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION
#180120
DC DIRECT CURRENT
(E) EXISTING 6.MYLEs STANDISH BLVD,TAANTON,MA.027.7.
ESS ENERGY STORAGE SYSTEM FAPXNE%0 °
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
MAG MAGNETIC ADRIANA NASCIMENTO
` MSP MAIN SERVICE PANEL 51 LUMBERJACK TRAIL,
(N) NEW YARMOUTH,MA,02673
NTS NOT TO SCALE
OC ON CENTER TEL.(774)810-5108
PRE-FAB PRE-FABRICATED APN:YARM-000074-000040
9 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER:
PV PHOTOVOLTAIC 223R-051NASC
RSD RAPID SHUTDOWN DEVICE
TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3
TYP TYPICAL MEHARBAN
V VOLTS
W WATTS SHEET
REV NAME DATE COMMENTS COVER SHEET
REV:A 8/292022
PAGE PV-1.0
F
SITE PLAN-SCALE=1/16"=1'-0" ARRAY TRUE MAG PV AREA
PITCH AZIM AZIM (SOFT)
AR-01 40' 180° 194° 313.7
10J
AR-02 15° 0° 14° 235.3
PL PL PL PL PL PL
(E)DETACHED (E)RESIDENCE
STRUCTURE
(N)ARRAY AR-02
' f f
r- a sunrun
PM INV
(N)ARRAY AR-01
0 AC- #180120
6.MYLES STANDISH BLVD TAUNTON MA 027807331
PHONE 0
FAX
CUSTOMER RESIDENCE:
ADRIANA NASCIMENTO
51 LUMBERJACK TRAIL,
YARMOUTH,MA,02673
PL PL
LUMBERJACK TRAIL TEL.(774)810-5108
PL APN:YARM-000074-000040
PROJECT NUMBER:
223R-051NASC
DESIGNER: (415)580-6920 ex3
MEHARBAN
SHEET
SITE PLAN
REV:A 8/29/2022
PAGE PV-2.O
f
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF
Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 13'-0" 16" COMP,SEE DETAIL SNR-DC 00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 11'-6" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 1'-7" STAGGERED 5/16":2.5"MIN EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES:
- - • INSTALLERS SHALL NOTIFY
D7-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL
AZIM:180° STRUCTURAL ISSUES
25'-8"
PITCH:40° 1'_ t__5,_g„ _.. ..14,_2„ , 5,-9„ -I' 10' PRIOR TO 10' } PROCEEDING W/
•
•11" 1 INSTALLATION.
• IF ARRAY(EXCLUDING SKIRT)
IS WITHIN 12"BOUNDARY
REGION OF ANY ROOF PLANE
EDGES(EXCEPT VALLEYS),
11'-4" THEN ATTACHMENTS NEED
1 '' NM
TO BE ADDED AND OVERHANG
REDUCED WITHIN THE 12"
16.-2" BOUNDARY REGION ONLY AS
FOLLOWS:
i
••ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
• ••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
D2-AR-02-SCALE:3/16"=1'-0"
AZIM:0° 32'_3 ' s u n r u n
PITCH:15° '-2,-0-, 11-7 ...........- .... _.._.9'-1 ---. , ....__ 11-7' ._----- ..,__.._ 1'-11"
- - #180120
2'-0" AZ IMEs srwos"BLVD,rAUN ON,IA.02,e67-13i
I PHONE 0
'I' - 0 0 ❑ ❑. FAA
---5'-4"TYP.--- CUSTOMER RESIDENCE:
ADRIANA NASCIMENTO
❑ ❑ - ❑ ❑ 51 LUMBERJACK TRAIL,
YARMOUTH,MA,02673
•
10'-4"
•
• I TEL.(774)810-5108
❑ - ❑ APN:YARM-000074-000040
PROJECT NUMBER:
5'-4"TYp 223R-051 NASC
STRUCT ;
C) Cl (9 Q_. ONL
--------+ 0y1N OFM4ys DESIGNER: (015)580-6920 ex3
_....._..1'}3„ off# 9cyG MEHARBAN
F VINCENT w
g MWUMVANEZA i, SHEET
CIVIL LAYOUT
�� e
ONALE�`a�� REV:A 8/29/2022
SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0
r
1
120/240 VAC
SINGLE PHASE
SERVICE
M O METER#:
EVERSOURCE 2289906 NOTE:TOTAL PV BACKFEED=40A
UTILITY USED FOR INTERCONNECTION
GRID CALCULATIONS
"I.__SUPPLY SIDE TAP
I ,4)
11 EXISTING 100A
(N)LOCKABLE
BLADE TYPE (N)MA SMART SE7600H-USSN GE WITH SOLAREDGE TECHNOLOGIES:
MAIN BREAKER FUSED AC UTILITY REVENUE GRADE METERING
I DISCONNECT REVENMETER 7600
7600 WATT INVERTER JUNCTION BOX PV MODULES
".---' (3) (3) (2) OR EQUIVALENT (1) LONGI GREEN ENERGY TECHNOLOGY
EXISTING ( / CO LTD:LR4-60HPB-355M
�-• 100A MAIN a,�, O �-4--; ( * "/ (28)MODULES
—▪ PANEL —
U OPTIMIZERS WIRED IN:
FACILITY 40A FUSES I I (1)SERIES OF(14)OPTIMIZERS
LOADS GROUND SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(14)OPTIMIZERS
D222NR8 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401
120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120
6.MYLES STANDISH BLVD,TAUNTON,MA 02780-7331
PHONE 0
CUSTOMER RESIDENCE:
ADRIANA NASCIMENTO
51 LUMBERJACK TRAIL,
YARMOUTH,MA,02673
MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)810-5108
LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000074-000040
TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-051NASC
OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC
MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-8920 ex3
SHORT CIRCUIT CURRENT: 11.25 A
MEHARBAN
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 9940 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 400 V
MAX ALLOWABLE DC VOLTAGE: 480 V
REV:A 8/29/2022
SYSTEM OPERATING CURRENT: 24.85 A
SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0
7
r
/'\WA RN I N G INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS,COLORS AND SYMBOLS.
TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S),
SIGNS AND LABELS,UNLESS OTHERWSE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
/WARNING
POWER SOURCE
LABEL LOCATION.
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. _-.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012:
SYSTEM 805.11.1.4
LABEL LOCATION: CAUTION :
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S):NEC 2020,705.12(C)
AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM 14
DO NOT RELOCATE THIS =�
OVERCURRENT DEVICE LABEL LOCATION:
L J INSTALLED WITHIN 3'OF RAPID SHUT DOWN
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020,690.56(C)(2),IFC SOLAR PANELS s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012.605 11 1.IFC 2018:1204.5.3
OCPD(IF APPLICABLE). ON ROOF
PER CODE(S):NEC 2020: 4"
705 12(3)(3)(2)
WARNING SOLAR PV SYSTEM EQUIPPED #180120
PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN MAIN- ses uv�ssrwa wo.sN erw•naJ,w•,aneorxa+
PHONE
COMBINER PANEL PANEL INTu
DO NOT ADD LOADS ( ) __ CUSTOMER RESIDENCE:
' i ADRIANA NASCIMENTO
LABEL LOCATION: 51 LUMBERJACK TRAIL,
PHOTOVOLTAIC AC COMBINER(IF YARMOUTH,MA,02673
APPLICABLE). L PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN INVERTER (EXT)
SWITCH TO THE"OFF" •v•.s,s TEL.(774)810-5108
POSMON TO SHUT DOWN —PV PRODUCTION METER APN:YARM-000074-000040
PV SYSTEM DISCONNECT f PV SYSTEM AND REDUCE PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT:31.67 AMPS
SHOCK HAZARD IN THEIli —FUSED AC DISCONNECT 223R-051NASC
NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY.
—SERVICE ENTRANCE DESIGNER: (015)580-6920 ex3
LABEL LOCATION: 51 LUMBERJACK TRAIL, YARMOUTH, MA, 02673 MEHARBAN
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. -- SHEET
PER CODE(S):NEC 2020:690.54 LOCATION:LABEL ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS _
ARE CONNECTED. REV:A 8/29/2022
PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0