Loading...
HomeMy WebLinkAboutBLDE-23-001200 � -\ Commonwealth of Official Use Only �E Massachusetts Permit No. BLDE-23-001200 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/5/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 51 LUMBERJACK TRAIL Owner or Tenant ADRIANA NASCIMENTO Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (No information submitted) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 Ga c I(/71Z1 ' RECE1VEC rti commonwealth. Official Use Only SEn o a99ac u9effa '{_} '`,� c� Permit No. a '' _, .2 eparfinenf ol ire �ervice9 BUILDING .e=_any==,' - Occupancy and Fee Checked By ____—' = SARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: City or Town of: To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) Owner or Tenant Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes ❑ No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps 120 / 240 Volts Overhead ❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd n No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Completion of the following table may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires SwimmingPool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units i No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. Initiatinnggon Dete and In Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other P Connection No.of Dryers Heating Appliances KW Security Systems:* rY No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications Wiring: Y g No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.N0.:4316 Al Licensee: Nathan Ashe Signature 7�4.-- LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my; ignature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent 78785943519 PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OFCONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:9940W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBCIIEBC), W SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(28)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS LISTINGS AND INSTALLATION SERVICE ENTRANCE LTD:LR4-6OHPB-355M INSTRUCTIONS. PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. PV-3.0 LAYOUT SE7600H-USSN MP MAIN PANEL — — •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. —0 n PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 - SNR MOUNT PV-5.0 SIGNAGE •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LAATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER _ FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) x METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). -. T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) � 7 SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC r, DC DISCONNECT(S) FIRE SETBACKS •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE E INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION SHOWN AS DASHED L J SCALE:NTS A AMPERE sunrun AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION #180120 DC DIRECT CURRENT (E) EXISTING 6.MYLEs STANDISH BLVD,TAANTON,MA.027.7. ESS ENERGY STORAGE SYSTEM FAPXNE%0 ° EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC ADRIANA NASCIMENTO ` MSP MAIN SERVICE PANEL 51 LUMBERJACK TRAIL, (N) NEW YARMOUTH,MA,02673 NTS NOT TO SCALE OC ON CENTER TEL.(774)810-5108 PRE-FAB PRE-FABRICATED APN:YARM-000074-000040 9 PSF POUNDS PER SQUARE FOOT PROJECT NUMBER: PV PHOTOVOLTAIC 223R-051NASC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL MEHARBAN V VOLTS W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV:A 8/292022 PAGE PV-1.0 F SITE PLAN-SCALE=1/16"=1'-0" ARRAY TRUE MAG PV AREA PITCH AZIM AZIM (SOFT) AR-01 40' 180° 194° 313.7 10J AR-02 15° 0° 14° 235.3 PL PL PL PL PL PL (E)DETACHED (E)RESIDENCE STRUCTURE (N)ARRAY AR-02 ' f f r- a sunrun PM INV (N)ARRAY AR-01 0 AC- #180120 6.MYLES STANDISH BLVD TAUNTON MA 027807331 PHONE 0 FAX CUSTOMER RESIDENCE: ADRIANA NASCIMENTO 51 LUMBERJACK TRAIL, YARMOUTH,MA,02673 PL PL LUMBERJACK TRAIL TEL.(774)810-5108 PL APN:YARM-000074-000040 PROJECT NUMBER: 223R-051NASC DESIGNER: (415)580-6920 ex3 MEHARBAN SHEET SITE PLAN REV:A 8/29/2022 PAGE PV-2.O f ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 13'-0" 16" COMP,SEE DETAIL SNR-DC 00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 2-Story 2X8 RAFTERS 11'-6" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON 1'-7" STAGGERED 5/16":2.5"MIN EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: - - • INSTALLERS SHALL NOTIFY D7-AR-01-SCALE:1/8"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:180° STRUCTURAL ISSUES 25'-8" PITCH:40° 1'_ t__5,_g„ _.. ..14,_2„ , 5,-9„ -I' 10' PRIOR TO 10' } PROCEEDING W/ • •11" 1 INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), 11'-4" THEN ATTACHMENTS NEED 1 '' NM TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" 16.-2" BOUNDARY REGION ONLY AS FOLLOWS: i ••ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% • ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:3/16"=1'-0" AZIM:0° 32'_3 ' s u n r u n PITCH:15° '-2,-0-, 11-7 ...........- .... _.._.9'-1 ---. , ....__ 11-7' ._----- ..,__.._ 1'-11" - - #180120 2'-0" AZ IMEs srwos"BLVD,rAUN ON,IA.02,e67-13i I PHONE 0 'I' - 0 0 ❑ ❑. FAA ---5'-4"TYP.--- CUSTOMER RESIDENCE: ADRIANA NASCIMENTO ❑ ❑ - ❑ ❑ 51 LUMBERJACK TRAIL, YARMOUTH,MA,02673 • 10'-4" • • I TEL.(774)810-5108 ❑ - ❑ APN:YARM-000074-000040 PROJECT NUMBER: 5'-4"TYp 223R-051 NASC STRUCT ; C) Cl (9 Q_. ONL --------+ 0y1N OFM4ys DESIGNER: (015)580-6920 ex3 _....._..1'}3„ off# 9cyG MEHARBAN F VINCENT w g MWUMVANEZA i, SHEET CIVIL LAYOUT �� e ONALE�`a�� REV:A 8/29/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 r 1 120/240 VAC SINGLE PHASE SERVICE M O METER#: EVERSOURCE 2289906 NOTE:TOTAL PV BACKFEED=40A UTILITY USED FOR INTERCONNECTION GRID CALCULATIONS "I.__SUPPLY SIDE TAP I ,4) 11 EXISTING 100A (N)LOCKABLE BLADE TYPE (N)MA SMART SE7600H-USSN GE WITH SOLAREDGE TECHNOLOGIES: MAIN BREAKER FUSED AC UTILITY REVENUE GRADE METERING I DISCONNECT REVENMETER 7600 7600 WATT INVERTER JUNCTION BOX PV MODULES ".---' (3) (3) (2) OR EQUIVALENT (1) LONGI GREEN ENERGY TECHNOLOGY EXISTING ( / CO LTD:LR4-60HPB-355M �-• 100A MAIN a,�, O �-4--; ( * "/ (28)MODULES —▪ PANEL — U OPTIMIZERS WIRED IN: FACILITY 40A FUSES I I (1)SERIES OF(14)OPTIMIZERS LOADS GROUND SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(14)OPTIMIZERS D222NR8 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 6.MYLES STANDISH BLVD,TAUNTON,MA 02780-7331 PHONE 0 CUSTOMER RESIDENCE: ADRIANA NASCIMENTO 51 LUMBERJACK TRAIL, YARMOUTH,MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(774)810-5108 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000074-000040 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-051NASC OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V DESIGNER: (415)580-8920 ex3 SHORT CIRCUIT CURRENT: 11.25 A MEHARBAN SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 9940 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 14 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 400 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 8/29/2022 SYSTEM OPERATING CURRENT: 24.85 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 7 r /'\WA RN I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690.OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWSE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC /WARNING POWER SOURCE LABEL LOCATION. DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. _-. AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 805.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020,705.12(C) AWARNING RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM 14 DO NOT RELOCATE THIS =� OVERCURRENT DEVICE LABEL LOCATION: L J INSTALLED WITHIN 3'OF RAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):NEC 2020,690.56(C)(2),IFC SOLAR PANELS s u n r u n ADJACENT TO PV BREAKER AND ESS 2012.605 11 1.IFC 2018:1204.5.3 OCPD(IF APPLICABLE). ON ROOF PER CODE(S):NEC 2020: 4" 705 12(3)(3)(2) WARNING SOLAR PV SYSTEM EQUIPPED #180120 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN MAIN- ses uv�ssrwa wo.sN erw•naJ,w•,aneorxa+ PHONE COMBINER PANEL PANEL INTu DO NOT ADD LOADS ( ) __ CUSTOMER RESIDENCE: ' i ADRIANA NASCIMENTO LABEL LOCATION: 51 LUMBERJACK TRAIL, PHOTOVOLTAIC AC COMBINER(IF YARMOUTH,MA,02673 APPLICABLE). L PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN INVERTER (EXT) SWITCH TO THE"OFF" •v•.s,s TEL.(774)810-5108 POSMON TO SHUT DOWN —PV PRODUCTION METER APN:YARM-000074-000040 PV SYSTEM DISCONNECT f PV SYSTEM AND REDUCE PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:31.67 AMPS SHOCK HAZARD IN THEIli —FUSED AC DISCONNECT 223R-051NASC NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. —SERVICE ENTRANCE DESIGNER: (015)580-6920 ex3 LABEL LOCATION: 51 LUMBERJACK TRAIL, YARMOUTH, MA, 02673 MEHARBAN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. -- SHEET PER CODE(S):NEC 2020:690.54 LOCATION:LABEL ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS _ ARE CONNECTED. REV:A 8/29/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0