Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 51 Lot / (, Zone of Contribution: In_ Out Acreage Commercial: Residential: W- Street: 7,A S ,' Village: .045 , li'Ls'I1 /j, Floor Plan: ✓ #Bedrooms:_ Owner: L/C(&Q (ó7 I Installer: e/z � . Address: J Phone: � V7 75- - .3 s f 5 Phone: n Builder: Engineer: n// isr/ Address: Phone: 7 7 - 0 -2-71 Phone: N/A YES NO 1.Required#of copies received 1../7 2. Date of soils exam and percolation test not older than 2 years l./.; 3. 4-5 ft of naturally occurring pervious material,above water table l 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands -t./! 7. Septic tank minimum 10 ft from foundation, deck Var.: V 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: -�'- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: tom.. 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: C� 15. System not in top or subsoil(A,B horizons)or 5' removal !^ 16. Proposed contours are suitable t/ 17. System meets slope requirements-min. 1/8", 1/4"preferred l� 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 1� 21.No garbage disposal 22. System adequately sized for its intended use '✓ 23. Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade _./ 25. Inspection port on plastic chambers/leach field `/'- 26. Electrical permit for pump chamber/Separate meter for duplexes �/ 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size �_.-- 28. Septic tank/pump chamber to be factory waterproofed -..---' 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map CPlan reviewed by: 6/03/03