HomeMy WebLinkAboutBLDE-23-002092 Commonwealth of Official Use Only �1 Massachusetts Permit No. BLDE-23-002092 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked rRev.1/07) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/19/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 37 SHORE SIDE DR Owner or Tenant DALAL AKSHAY N TRS Telephone No. Owner's Address DALAL SHOBHANA A TRS,21 WITS END,WESTQN,MA 02493 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(13 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- 13No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW ,No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers t Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:. No.of Devices or Eauivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No,of Devices or Eauivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: David V Poshkus Licensee: David V Poshkus Signature LIC.NO.: 14823 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:117 MECHANIC ST,CANTON MA 020213111 Alt.Tel.No.: °Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 is(8 1-�, . F.- - - . - 1 T 1 g 2022 iL9aoi maniac etlo Official Use Only ; _ _ Permit No. Z3� zo9 .z, a .„:„.f I t, 'o 0 E NA R I PJl E N Z IIDI dmen' el JN1B Sere ce3 I. =, - Occupancy and Fee Checked ;, : •ARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC), 527 CMR 11.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 10-17-22 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location (Street& Number) 37 SHORESIDE DRIVE Owner or Tenant AKSHAY DALAL Telephone No. (617) 633-1244 Owner's Address 37 SHORESIDE DRIVE, YARMOUTH, MA 02664 Is this permit in conjunction with a building permit? Yes ❑ No Ti (Check Appropriate Box) Purpose of Building Utility Authorization No. 10503742 Existing Service Amps / Volts Overhead Ti Undgrd Ti No. of Meters New Service Amps / Volts Overhead ❑ Undgrd ❑ No. of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: INSTALL OF 13 PANELS FOR ROOFTOP SOLAR Completion of the following table may be waived by the Inspector Wires. No. of Recessed Luminaires No. of CeiL-Susp. (Paddle) Fans No. of Total Transformers KVA No. of Luminaire Outlets No. of Hot Tubs Generators KVA No. of Luminaires Swimming Pool Above ❑ In- ❑ No. of Emergency Lighting grnd. grnd. Batter* Units No. of Receptacle Outlets No. of Oil Burners FIRE ALARMS No. of Zones No. of Switches No. of Gas Burners No. of Detection and 1 Initiating Devices No. of Ranges No. of Air Cond. Toil No. of Alerting Devices Tons r Heat Pump Numbe Tons KW 'No. of Self-Contained No. of Waste Disposers • • --.--.Totals: -- Detection/Alerting Devices No. of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other Connection No. of Dryers Heating Appliances KW Security Systems:* No. of Devices or Equivalent No. of Water KW No. of No. of Data Wiring: Heaters Signs Ballasts No. of Devices or Equivalent No. H•ydromassage Bathtubs No. of Motors Total HP Telecommunications Wiring: No. of Devices or Equivalent OTHER: Attach additional detail if desired or as required by the Inspector of Wires. Estimated Value of Electrical Work: 10000 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10, and upon completion. INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including "completed operation" coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER ❑ (Specify:) I certify, under the pains and penalties of perjury, that the information on this ap lication is true and complete. FIRM NAME: VIRIDIS ENERGY SOLUTIONS LLC -� LIC. NO.: 14823-A Licensee: DAVID V POSHKUS Signature _ / LIC. NO.: 14823 (If applicable. enter "exempt" in the license nwnher line.) j `` us. Tel. No.: 617-669-5534 Address: 15 LANCASTER AVE, REVERE, MA 02151 Alt. Tel. No.: _ *Per M.G.L. c. 147, s. 57-61, security work requires Department of Public Safety "S" License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the (check one) ❑ owner ❑ owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ AKSHAY DALAL- 5.525KW DC,4.992KW AC SYSTEM INFORMATION DC SYSTEM SIZE:5525W SITE PLAN AC SYSTEM SIZE:4992W MODULES: (13)SUNPOWER SPR M425-H-AC 425W SSW INVERTER: F. (13)ENPHASE IQ7HS BRANCH DETAILS: £ 55°OjOo` 1 BRANCH OF 6 AC MODULES c,SNORpFt or 37ShoresideDr. ®S ENGINEER OF RECORD •South Yarmouth,MA ad°a ... B yQ �' -3' .,,ZH OFM1>,q Al VICINITY MAP teUL K. PV-1.0 I SCALE:NTS CTURAL y GENERAL INFORMATION `S31ONALetC' ELECTRIC CODE NEC 2020 RESI�DE�NI7ALDCODE15 V i rid is ENERGYSOLUTIONS BUILDING CODE IBCIRC 2015 185 NEW BOSTON STREET, WIND SPEED 142 MPH WOBURN MA,01801 ' /////'i'1''�� SNOW LOAD 3OPSF CUSTOMER INFORMATION //iQ��j O//////' INDEX NAME&ADDRESS: DALAL /////' 1////i ' INDEX NO. DESCRIPTION 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 /////'///// WA**' PV-1.0 SITE PLAN 41°64'30.3"N 70.20'72.2"W //i/////1/ !>0 PV-2.0 GENERAL NOTES ////O'//O/ PV-3.0 MOUNTING DETAILS AHJ:MA-BARNSTABLE IOW PV-3.1 STRUCTURAL DETAILS (E)MAIN SERVICE PANEL / ///Q/// ' PV-4.0 SINGLE LINE DIAGRAM (INTERIOR) //////// O ' U///0/j//// OIIIIIII‘ PV-4.1 STRING WIRING PV 5.0 WARNING CAD[ PROJECT NUMBER: (N)ENPHASE IQ COMBINER 3 r// // (EXTERIOR) T//// (N)UTILITY AC DISCONNECT O PHOTOVOLTAIC ARRAY ON ROOF PV-6.0 MODULE SPEC SHEET SITE PLAN (EXTERIOR) O PV-6.1 RACKING SPEC SHEET (E)UTILITY METER PV-6 2 MOUNT SPEC SHEEP DESIGNER/CHECK ED BY: (EXTERIOR) SOLAROFIX PV-6.3 ENPHASE COMBINER SPEC SHEET A SITE PLAN � 'Ti ► gnu gnu F:AS NOTED PAPER SIZE:17"x11" " W-1.0 SCeI F:3/32"=1'-0" DATE:9/8/22 REV:A PV-1.0 GENERAL NOTES SYSTEM INFORMATION GENERAL NOTES INTERCONNECTION NOTES: DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 26.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 690.64(B)]2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 27.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120%OF BUSBAR MODULES:MODULES:(13)SUNPOWER SPR M425-H-AC 425W 3.DRAWINGS ARE DIAGRAMMATIC,INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL RATING[NEC 705.12(D)(2X3)]. SITE CONDITION MIGHT VARY. 28.WHEN SUM OF THE PV SOURCES EQUALS>100%OF BUSBAR RATING,PV DEDICATED BACKFFED BREAKERS INVERTER: 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(DX2X3)]. (13)ENPHASE IQ7HS ACCORDANCE WITH NEC 110.26(AX1). 29.AT MULTIPLE PV OUTPUT COMBINER PANEL,TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT BRANCH DETAILS: 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/SERVICE EXCEED AMPACITY OF BUSBAR.HOWEVER,THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED 1 BRANCH OF 7 AC MODULES EQUIPMENT. ACCORDING TO NEC 705.12(DX2X3)(C). 1 BRANCH OF 6 AC MODULES 6.ALL CONDUCTORS SHALL BE 600V,75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 30.FEEDER TAP INTER CONNECTION(LOAD SIDE)ACCORDING TO NEC 705.12(DX2X1)SUPPLY SIDE TAP ENGINEER OF RECORD 7.WHEN REQUIRED,A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE REGULATIONS. WITH NEC 230.42 BACK FEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL ADDITIONAL FASTENING[NEC 705.12(DX5)]. JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND GROUNDING NOTES: LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS 31.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES TREES,WIRES OR SIGNS. EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING 32.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC 250.122. 33.METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND ENCLOSURES CONSIDERED GROUNDED IN EQUIPMENT LOCATION: ACCORD WITH 250.134 AND 250.136(A). A.1:tN OVW'R 34.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICRO INVERTER PAUL K. 11.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26(AX1). MANUFACTURER'S INSTRUCTIONS. /, ZACHER 12.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING 35.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER •I STRUCTURAL N TEMPERATURE AS SPECIFIED BY NEC 690.31(A),(C)AND NEC TABLES 310.15(BX2XA)AND 310.15(BX3XC). DOCUMENTATION AND APPROVED BY THE AH).IF WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST t 13.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS INSTALLATION \ •� t.;491 O 4_ 14.ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE REQUIREMENTS. SSTE1'c ' AC SERVICING DISCONNECT. 36.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE �SSiONAI� 15.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. APPLICABLE CODES. 37.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLORED GREEN OR MARKED GREEN IF 16.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE X4 AWG OR LARGER[NEC 250.119] 38.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH VIDEO IF V i ri d i s 'STRUCTURAL NOTES: EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250,NEC 690.47 AND ANI). 17.RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION 39.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.5 IN GENERAL AND NEC 690.5(AX1) E N E R G Y S O L U T I O N S MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND SPECIFICALLY. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAIL 40.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 185 NEW BOSTON STREET, MANUFACTURERS INSTRUCTIONS. 41.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS WOBURN 18.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.IF ROOF-PENETRATING TYPE,IT REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER MA,01801 SHALL BE FLASHED&SEALED PER LOCAL REQUIREMENTS. TERMINALS). CUSTOMER INFORMATION 19.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL 42.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A GFAI ANT PER CODE BY A LICENSED CONTRACTOR. VISIBLE-BREAK SWITCH 20.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY 43.RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING NAME&ADDRESS: THE RACKING MANUFACTURER. WITHIN 10 SECONDS.CONTROLLED CONDUCTORS 530V AND 5240VA[NEC 690.12].LOCATION OF LABEL AKSHAY DALAL 21.WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF ACCORDING TO AH3. 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 FRAMING MEMBERS. 44.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9 AND 240. 41°64'30.3"N 70°20'72.2"W 45.MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH WIRING&CONDUIT NOTES: NEC 110.3(B).2.6.7 IF REQUIRED BY AHD,SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. AW:MA-BARNSTABLE 22.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 23.CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. 24.DC WIRING LIMITED TO MODULE FOOTPRINT.MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. PROJECT NUMBER: 25.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:PHASE A OR Ll-BLACK PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3-BLUE,YELLOW,ORANGE**,OR OTHER CONVENTION NEUTRAL-WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO GENERAL NOTES BE MARKED ORANGE[NEC 110.15]. DESIGNER/CHEMED BY: SOLAROFM SCALE:AS NOTED PAPER SIZE:17"xll" DATE:9/8/22 REV:A PV-2.0 DEAD LOAD CALCULATIONS SITE INFORMATION SYSTEM INFORMATION — BOM QUANTITY LBS/UNR TOTAL WEIGHT(LBS) SR.NO AZIMUTH PITCH NCI CW ARRAY AREA ROOF TYPE ATTACHMENT ROOF FRAME TYPE FRAME FRAME MAX RAIL OVER DC SYSTEM SIZE:5525W MODES (SQ.FT.) EXPOSURE SIZE SPACING SPAN HANG �� SIZE:4992W MODULES MODULES 13 48 624.00 - COMPOSITION PEGASUS L MODULES: MID-CLAMP 20 0.050 1.0 MP-01 158° 30° 3 62.34 SHINGLE FOOT(INVISMOUNT) ATTIC RAFTERS 2 X 10 1.-4" 2'-8" 2'-0" (13)SUNPOWER SPR M425-H-AC 425W END-CLAMP 12 0.050 0.6 INVERTER: MP-02 158° 30° 10 207.80 COMPOSITION PEGASUS L ATTIC RAFTERS 2 X 8 1'4" 2'-8" 2'-0" (13)ENPHASE IQ7HS RAIL LENGTH 90 0.680 61.20 SHINGLE FOOT(IMVISMOUNT) BRANCH DETAILS: SPLICE BAR 0 0.360 0.00 1 BRANCH OF 7 AC MODULES 1 BRANCH OF 6 AC MODULES PEGASUS L 42 1.35 56.70 NOTE:FOR ARRAY 1 NOTE:FOR ARRAY 2 ENGINEER OF RECORD FOOT(INVISMOUNT) 2x10 RAFTERS©16"O.C.(VLF) 2x8 RAFTERS(�16"O.C.(VIF) TOTAL WEIGHT OF THE SYSTEM(LBS) 743.50 MAXIMUM HORIZONTAL SPAN MAXIMUM HORIZONTAL SPAN OF THE RAFTERS BETWEEN OF THE RAFTERS BETWEEN TOTAL ARRAY AREA ON THE ROOF(SQ.FT.) 270.14 BEARING SUPPORTS SHALL BEARING SUPPORTS SHALL WEIGHT PER SQ.FT.(LBS) 2.75 NOT EXCEED 19'-0". NOT EXCEED 15'-9". WEIGHT PER PENETRATION(LBS) 25.82 0,°F44Sy+9 PAUL K. �. ZACHER -a v, STRUCTURAL ti No.5D100 " / �+q �'G/STEP \F /oNAIry MODULES DATA SUNPOWER SPR M425-H-AC 425W __, V i ri d i s MODULE DIMS 75.4"x42.2"x1.57" 6 LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT E N E R G Y S O L U T I O N S FIRE SETBACK 185 NEW BOSTON STREET, WOBURN MINIMUM FIRE AfrFSS PATHWAYS PER IFC 2015 /, '.�% A,01801 • f • ••RIDGE TO ARRAY:3'-0" o 4 • • CUSTOMER INFORMATION EAVE TO ARRAY:3'-0" 0 HIP/VALLEY WI ADJACENT ARRAY:1'-6" • • I • • • • • • • • • • NAME&ADDRESS: FACH SIDE HIP/VALLEY W/O ADJACENT ARRAY:0'-0" OII AKSHAY DALAL NOTE:INSTALLER TO VERIFY RAFTER SIZE,SPACING AND SLOPED I • • • • 4 • • 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 SPANS,AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. 41°64'30.3"N 70°20'72.2"W O O I_ AERIAL VIEW • •• •• • • • r AH:MA-BARNSTABLE S�oIE,;tdE DI _ — ED1 V \— 2X10 RAFTERS @ 2X8 RAFTERS @ PROJECT NUMBER: oce'd h r is c��{ V-4"SPACING 1'-4"SPACING h outh Yarmouth,t�A�- ALUMINIUM RAILS ALUMINIUM RAILS MOUNTING DETAILS ARRAY MP-01 ARRAY MP-02 p�"V DESIGNER/CHECKED BY: . r. ' a .• I SOIAROFDC y; 'j /i� k SCALE:AS NOTED PAPER SIZE:IT'xll" w °.�c«`( .'"" B I MOUNTING DETAILS q1i�/ . "-- ::" �• ,. SCALE:1/8"=1'-0" DATE:9/8/22 REV:A PV-3.0 GROUNDING DETAILS ROOF FRAMING DETAIL SYSTEM INFORMATION MODULE TO MODULE&MODULE TO RAIL MP:1 MP] DC SYSTEM SIZE:5525W /—�� 55 BONDING PIN AC SYSTEM SIZE:4992W / RAIL RAIL MODULES: / 1 MID CLAMP INVERTER: /ER SPR M425-H-AC 425W J—_-_—\>,�, ASSEMBLY 6" 6" \ - / (^'ter' SOLAR MODULE SOLAR MODULE / (13)ENPHASE IQ7HS \_ ' BRANCH DETAILS: MODULE PEGASUS IINvm MO 0 WISI M UNI) 1 BRANCH OF 7 AC MODULES FRAME 1 BRANCH OF 6 AC MODULES ENGINEER OF RECORD / 1 /IAA � RAIL RA IFTERSC1'.A' RAFTERS01'-4' // SPACING SPACING \ // CHANNEL NUT GROUNDING MID-CLAMP SCALE NTS DAD BEARING WALL I LOAD BEARING WALL GROUNDING 0ytH UL 44 ' PAUL K. ZACHER 5/16"-18 SS BOLT SCALE:NTS - STRUCTURAL w 6-12 AWG BARE SS SPLIT LOCK WASHER No.50100 /'— \ COPPERw1RE (TORQUE To16FTLes) ATTACHMENT DETAIL-PEGASUS L-FOOT(INVISI MOUNT) AGISTec:4� / ram _ / - 619/ONAL / . mm GROUNDING LUG // \� PV MODULE \ / / =Mi BOUNDING // \ \ / \r✓,..+ RAIL / RAIL 6 Viridis �I ' RAIL / \ / (E)COMPOSITION SHINGLE ENERGY SOLUTIONS ( ( ROOF 185 NEW BOSTON STREET, NOTES: 1 WOBURN •ALL HARDWARE IS INCLUDED FROM MANUFACTURER 5/16 HEX-BOLT MA,01801 •A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CUSTOMER INFORMATION CONTINUOUS ROW OF MODULES \ / 'GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL \ FPEGASUS L OOT(INVISI MOUNT) •GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARAI I FI NAME&ADDRESS: OR PERPENDICULAR TO RAIL STAINLESS STEEL 5/16"HANGER• / AKSHAY DALAL ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE. BOLT 2.5"EMBEDMENT 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 NT SCALE. S PILOT HOLE REQUIRED \ / 41°64'30.3"N 70°20'72.2"W RAIL TO RAIL \\ / (E)BUILDING _—_, STRUCTURE SELF-DRILLING SCREW AM:MA-BARNSTABLE RAIL SCAT F:NTS MID-CLAMP&END CLAMP DETAIL p�� PROJECT NUMBER: ��__�� MID CLAMP RAIL END CLAMP _ — - PV MODULE STRUCTURAL DETAILS /'� \�\ PV MODULE ♦ RAIL 1 DESIGNER/CHECKED BY: I I 1 SOLAROFD( i I. I 1 INTERNAL SPLICE N\ / \ / SCALE:AS NOTED PAPER SIZE:17"x11" ♦ / • i sra(F•NTS SCAIF NTS - '--' DATE:9/8/22 REV:A PV-3.1 SINGLE LINE DIAGRAM: — 5.525KW DC,4.992KW AC SYSTEM INFORMATION DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W MODULES: (13)SUNPOWER SPR M425-H-AC 425W NOTE: INVERTER: 1.EACH AC MODULES ARE RAPID SHUTDOWN COMPLAINT 705.12(Bx2)(3)(C) (13)ENPHASE IQ7HS 2.AC MODULES ARE UL1741 RATED OCPD CALCULATIONS: BRANCH DETAILS: THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT 3.MA SMART UTILITY REVENUE—METERS ARE BI-DIRECTIONAL,NET ES DEVICES ON PANELBOARDS BOTH LOAD AND SUPPLY MAIN PANEL RATING:125A, 1 BRANCH OF 7 AC MODULES , METER AND UTILITY OWNED.METER LOCATIONS DETERMINED BY 1 BRANO-I OF 6 AC MODULES UTILITY FOR AMR ACCESS REQUIREMENTS. DEVICES,OCCLUDING THE RATING OF MAIN BREAKER RATING:100A ENGINEER OF RECORD THE OVERCURRENT DEVICE PROTECTIN THE BUSBAR, 120%RULE:(125AX1.2)-100A=50A,PV=30A ALLOWABLE BAOGEED IS 50A SHALL NOT EXCEED THE AMPACITY Of THE BUSBAR. INVERTER OVERCURRENT PROTECTION= INVERTER 0/P I X CONTINUOUS LOAD(1.25)X !OF INVERTERS=13X1.6x1.25=264 =>PV BREAKER=30A ALLOWABLE BACKFEED 50A=>30A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(8X2)(3)(C) REQUIREMENTS C70 SO 0 EXISTING 120/240V IPH 6OHZ (E)125A END FED MAIN PANEL H�11- (N)BOA6(N)SUNPOWER S NR 425 V I ri d i s(E)100A QPHPSE 4 25W MODULES MAIN IQ COMBINER 3 v v -•M C -I REAPHp Q7XS BREAKER-el. (X-IQ-AM 1-240-3) (IQ7HS-96-ACM US) E N E R G V SOLUTIONS , y p ma )a°nun (1)BRANCH OF(7)MODULES `y, ,c onraa"r (N)SOLADECK (.IMAM,. _ I (7)SUNPOWER SPR M425-H-AC 425W MODULES 185 NEW BOSTON STREET, WOBURN 2 (N)SUNPOWER SPR M425-H-AC 425W, MA,01801 ® g ad- o o �"�I��WITHINTEGRATED "�Q7XS CUSTOMER INFORMATION ,-1-{--}- (IQ7HS-96-ACM-US) mwa. UTILITY aeidur ME E, W r I 1 :::�(1)BRANCH OF(6)MODULES (E)GROUND ° SOIADECK PV (6)SUNPOWER SPR M425-H-AC 425W MODULES NAME&ADDRESS: ELECTRODE• a punr�irt�o�u*co RI2OFM UNI AC AKSHAY DALAL OUTSICEWN,,,a,Mkt pi. 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 41°64'30.3"N 70°20'72.2"W AH):MA-BARNSTABLE PROJECT NUMBER: SINGLE LINE DIAGRAM DESIGNER/CHECKTD BY: SOLAROFIX SCALE:AS NOTED PAPER SIZE:17"xll" DATE:9/8/22 REV:A PV-4.0 SINGLE LINE DIAGRAM: -5.525kW DC, 4.992kW AC SYSTEM INFORMATION DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W AC MODULE SPECIFICATION EQUIPMENT SCHEDULE MODULES: SUNPOWER DESCRIPTION PART NUMBER NOTES (13)SUNPOWER SPR M425-H-AC 425W MODEL SPR M425-H-AC 425W (13)ENPHASE IQ7HS ACP2,MULTI CIRCUIT SUNPOWER SPR M425-H-AC 425W E TYPE MODULE POWER 0 STC 425W SOLADECK 1.60A BRANCH DETAILS: MAX.CONTINUOUS OUTPUT POWER W AINVALLT ESS,BASE S'-BASE13-12-A 1 BRANCH OF 7 AC MODULES METER/MAIN CCMBO _-. 1 BRANCH OF 6 AC MODULES OUTPUT CURRENT 1.60A ENGINEER OF RECORD CEC WEIGHTED EFFICIENCY 97.5% NO.OF MAX.AC MODULES/STAING 10 ELECTRICAL NOTES: 1.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 2.BREAKER/FUSE SIZES CONFORMS TO NEC 240.6 CODE SECTION. 3.AC GROUNDING B ECTROCE CONDUCTOR SIZED PER NEC 250.66. 4.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON NEC 690.31(A). 5.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON NEC 310.15(BX2)(C)AND 310.15(BX2)(B) 6.AC SYSTEM VOLTAGE CORRECTION IS PER NEC 690.7(A) 7.CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE NEC 310.15(B)(16). 8.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 310.10(D). 9.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC 310.10(C). CONDUIT SCHEDULE TAG ID CONCUR SIZE CONDUCTOR NEUTRAL GROUND V i ri d i s NONE (Z)12 AWG ENPMASE Q CABLE NONE (1)6 AWG BARE COPPER PER BRANCH CIRCUIT EN FRGY SOWTIONS 2 1/2"EMT OR EQUIV (4)12 AWG THHN/TTRWN-2 NONE (1)12 AWG THHN/THWN-2 185 NEW BOSTON STREET, 3 3/4"EMT OR EQUIV (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 WOBURN MA,01801 CUSTOMER INFORMATION NAME&ADDRESS: ELECTRICAL CALCULATION AKSHAY DALAL 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 AC WIRE CALCULATIONS:-MATERIAL:COPPER&TEMPERATURE RATING:90°C 41°64'30.3"N 70°20'72.2"W IAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 1 1.6 X 7 = 112 X 1.25 = 14A 30 X 0.96 X 1 = 28.80A 14A < 20A 14A < 28.80A ANIMA-BARNSTABLE 2 1.6 X 7 = 112 X 1.25 = 14A 30 X 0.96 X 0.8 = 23.04A 14A < 20A 14A < 23.04A 3 1.6 X 13 = 208 X 1.25 = 26A 40 X 0.96 X 1 = 38.40A 26A <= 30A 26A < 38.40A PROJECT NUMBER: ELECTRICAL CALCULATION DESIGNER/CHECKED BY: SOLAROFIX SCALE:AS NOTED PAPER SIZE:17"x11" DATE:9/8/22 REV:A PV-4.1 WARNING PLACARDS SYSTEM INFORMATION ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION,BACKGROUND ON ALL PLACARDS SHALL BE RED DC SYSTEM SIZE:4992W • AC SYSTEM SIZE:4992W PHO TO/OLTAIC SYSTEM AC DISCONNECT SWAT WITH WHITE LETTERING U.O.N. - 20•S r PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS MODULES: ' £ ELECTRIC SHOCK HAZARD - y"•1a A 4.1L Ass +o. APPROVED BY THE LOCAL JURISDICTION (13)SUNPOWER SPR M425-H-AC 425W INVERTER: DC CONDUCTORS OF THIS PHOTOVOLTAIC STSI tM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION NOTE:ALL SIGNAGE CANNOT BE HAND WRITTEN NEC 110.21 AC DISCONNECT,POINT OF INTERCONNECTION (13)ENPHASE IQ7HS LABEL LOCATION [PER CODE:NEC 690.54] WA RN I N G A BRANCH DETAILS: DC DISCONNECi,INVERTER .�., a,,, ! 1 BRANCH OF 7 AC MODULES [PER CODE:NEC 690.41)] WARNING 1 BRANCH OF 6 AC MODULES [To be used when inverter Is ungrounded] V DOER O L.REPOCATOE THIS ION POWER TO THIS BUILDING IS ALSO ENGINEER OF RECORD ARNING-Electric Shock Hazard OVER-CURRENT DEVICE SUPPLIED FROM THE FOLLOWING User Serviceable Parts inside art authorized service provide for LABEL LOCATION SOURCES WITH DISCONNECTS LOCATED assistance POINT OF INTERCONNECTION AS SHOWN LABEL LOCATION (PER CODE:NEC 705.12(2)(b) [...Mrww.e is mind mat iN4R Imo x.•Am al may raft. r INVERTER,JUNCTION BOXES(ROOF), awe.. AC DISCONNECT [PER CODE:NEC 690.13) CAUTION: SOLAR CIRCUIT ARNING:PHO70VOLTAIC LABEL LOCATION POWER SOURCE MARKINGS RACED DV ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES AND CABLE ASSEMBLES AT \ LABEL LOCATION LEAST EVERY 10 FT,AT TURNS AND ABOVE/BELOW CONDUIT,COMBINER BOX PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. [PER CODE:NEC690.31(GX3)1 (PER CODE:IFC605.11.1.4) WARNING SOLAR DISCONNECT '' TRI POWER SOURCE SECOND OY SOURCE 1S PHOTOVOLTAIC SYSTEM LABEL NECT,PO ','''' THIRD POVI• �K&TORS;E DISCONNECT,POINT OF INTERCONNECTION ° �. [PER CODE:NEC690.13(8)J ''' o ,/ PORNfLOCATION INTERCONNECTION CAUTION:SOLAR ELECTRIC 4) Y! k SYSTEM CONNECTEDNS LABEL LOCATION (N)ENPHASE IQ COMBINER 3 WEATHER RESISTANT MATERIAL,DURABLE ADHESDNE, (EXTERIOR) o 0 185 NEW BOSTON STREET, L RNI' UL969 AS STANDARD TO WEATHER RATING(UL LISTING WOBURNERTERS L OF MARKINGS NOT REQUIRED),MIN j"LEI Itit HEIGHT MA,01801 NDER MODU ARIAL OR SIMILAR FONT NON-BOLD,PIACED WITHIN PHOTOVOLTAIC THE MAIN SERVICE DISCONNECT,PLACED ON THE ARRAY ON ROOF CUSTOMER INFORMATION OUTSIDE OF THE COVER WHEN DISCONNECT IS LABEL LOCATION OPERATED WITH THE SERVICE PANEL CLOSED. (N)UTILITY AC DISCONNECT DC DISCONNECT,INVERI'ER (PWER CODE:NEC690.15,690 13(B)) (EXTERIOR) NAME&ADDRESS: [PER CODE:NEC 690.41)) (E)UTILITY METER To be used when!meter Is ungrounded) e ��+"•. r,.,.,.,, (EXTERIOR) AKSHAY HALAL JD SHUTDOWN SWITCH (E)MAIN SERVICE PANEL 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 R AR SYSTEM 41°64'30.3"N 70°20'72.2"W (INTERIOR) LABEL LOCATION INVERTER,POINT OF if ` AHJ:MA-BARNSTABLE INTERCONNECTION SYSTEM UTILIZES (PER CODE:NEC 690.56(CX3)] MICRO-INVERTERS LABEL LOCATION i . LOCATED UNDER POINT OF INTERCONNECTION , , SOLAR MODULE SOLAR PV SYSTEM EQUIPPED CAUTION WITH RAPID SHUTDOWN PROJECT NUMBER: _._,.. �' 37 SHORESIDE DR,SOUTH YARMOUTH, MA 02664 ... TURN RAPID SHUTDOWN SWITCH TO THE - WARNING PLACARDS "OFF"Posrnon TD SHUT DOWN PV SYSTEM RI'6Lg5N H ','` LABEL LOCATIONAND REDUCE DESIGNER/CHECKED BY: NEC 705.12(B)(2X3XC)-BY BREAKER AT SHOCK HAZARD SOLAROFIX DISTRIBUTIONT EQUIPMEN IN THE ARRAY LABEL LOCATION SCALE:AS NOTED PAPER SIZE:17'x11" AC DISCONNECT,DC DISCONNECT,POINT OF LABEL LOCATION (PER INTERCONNECTION CODE:NE0690.56(CXI)(A)) POINT OF INTERCONNECTION DATE:9/8/22 REV:A PV-5.0 SYSTEM INFORMATION DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W MODULES: (13)SUNPOWER SPR M425-H-AC 425W INVERTER: (13)ENPHASEIQ7HS BRANCH DETAILS: 0 S U N P - W E R` M-Series:M440(M435 I M430 I M425 I M420 SunPower®Residential AC Module 1 BRANCH OF 7 AC MODULES 1 BRANCH OF 6 AC MODULES • ENGINEER OF RECORD 'Inverter Model.Type H lEnphase IO7N5) 0240 VAC 0206 VAC 1.-.._—. _— —_J Max.Com:mews Output Power IA) 394 369 420-440W Residential AC Module Non(1.-L)Vottage/Rarge M- -_ 240/211-264 208n83-229 I_M.ar Continuo.O PA Current(Wns) 160 — _-- 177 ___— -- ' SunPower'Maxeon'Technology i M.unit:per 20 R a-u*ranch d«ur 10 1- • Built specifically for use with the SunPower Equinox*system,the only fully _�Ec Weighted En�aan�y_,. _ 9z0aE 96s� • NomFrequency _._ 60H _ integrated solar solution designed,engineered,and warranted by one company. -E„tended Frequency Range 47ig Hi I - AC Shod Circwraon Curren Oren 3 Clcks 4.82 Amw ® Highest Power AC Density Available. i Overw Port Class AC Po m rAC wna«neeecomen, _ temA • Thepatented,solid-copper foundation Maxeon Gen 6 cell is over e-------_-- - __ -- ------ — ---- PP Rawer race Setting t o r. 5%larger than prior generations,delivering the highest efficiency •Poww Factor I aI blel oestlydmMel/ons«aprdtne) AC solar panel available' rm41.36 8 .235%- sanasu6 YResuo- Wamamles '25yesr Raked power womanly -- NMI HK .sC es.<C 42 _ •251n16, 1.154709t eenanty ___, rvooe Po"er•lvnum)w 410 435 430 s25 420 •uL1741 ACMo Module ' Power Tokrarce 4Y-0% .uL 61730 Module dype2MeraM1 _ MOdleEllkleexy 22811 22.5/1 22.311 22.0% 21.1% •UL62109-,/IEC62109.2 ' Temp.Co (Power) -0.29M/<c ---e. •ICE5.0003 Class c-E a E Stade Tolerance k4552,edmodueJM°WA Power poeoen 'CAN/CSAC222 NO.107.1.01 • •CA Rue 21 NL 1741 5A)• • 1ill':!t'1 Cer,Nice,,,„ (mnudes Vat/War and Reactive Power Pnonty) �• aM •U1 L9ted INRape...ernEGuewnenc Complence •NEC 6 installation module) ar,ce wnm. . Opereeng Temp. d0'Pto<1a5'FI-40•C t0.65•Cl NEC 6906(AC module) 6 I.riu is Part of the SunPower Mat Amble Temp 122•r(50'C) •NEC 690.12 Rapid shutdown Onside aM outside the V Equinox'SoarSystem �ggu Test Snow, 187ps1.WO Pa,917g/rtr front •NEC 690.15 ACC ENERGVSOLUTIDNS $now 125 psf.WOF 611 een•PpM ors,690 3YA1{Eg,7 Deng Las W e 75 ps1 3600 Pa,36 Rg/re•back When used wtth AC modu e O Cables d accessories -Compatible with �C'7 Highest Lifetime Energy and Savings snow,2s p.r 6000 Pa,6)1 Wee from _... lUt 6703 and u1223g1 185 NEW BOSTON STREET, mpaa Rnlstance 1 h(.25 )diameter hag t 52 mph 123 M 1 •Rated for load br d came[ m unPowerlN monitoring —Test -- 1000 V-IEC 62001 _ - - ----. WOBURN Designed to deliver 60%more energy over 25 years in • --- -- ------- - --- ----- Io lea, Seamless aesthetics real-world conditions like partial shade and high temperatures. MA,01801 91 '".'sn _ 1,7: -- - „e r,n r _I 6 ;Front A I 1 . w meow i I mege Solar Ceds Glass a GE M Gen6 -_—. Modules.-.p- e pallet 25 High mssbn per dglas h antl.relMaAe coang acYap gbo Nmendpns7,5 4.42244e0_tn t em I Rance Outdoore0 m I w gn 11 M ouemSepa rieM 3o 13a1aamm1me:ea mg aaa taut „ n915+1072. — mm) P g_o rgn4_ 13007roe590 rm Pallets per container 32 _ _---_ _ --Le welgmper mnwner 41,623mue.ae010 CUSTOMER R INFOR MA TION NAME&ADDRESS: AKSFAY DALAL 37 SHORESIDE DR,SOUTH YARMOUTH,MA 026 64 t. oA 41°64'30.3"N70°20'72.2"W ra,w r <dre 'n.,senlm MMe,rew.,oil,wOsaesa!OP lommuleoers net dun n,nekenre us IN. 033N1 -.... .__..__.nen ermt— -+ FRAME RR°NF n s 1 Iwer f Factory-Integrated Mkroltivester Years of operatem m ''"1 wee v,1(,mgu N, 14 1 gw.dm f �„<,,, nM R AHJ:MA-BARNSTABIE Highest-power integrated inn.del, tier rtod n ral olers rw'',, eea `€ AC module in solar BestReliabilty,BestWarranty wivj1001W""""°"01.1a. �ipNWO12,an<'sh''I2015 1e64"8Rapid"" ° n e,re.oPwt1� e x,�dwn,,r.ar w«.,aaw:).P�"nx mml r„t ti,Nd..PW1sE w,ti r,.,rmm„nm NEC/o,..m Na 217 a,>o Iz.,d rn.I 20„Re.p4:,e R,r.d Engineered and calibrated shuldow,of w:„System for K anti IXroroncto,wn.n.malled w,r.dingto nwlM aver.Imna,nom. • With more than 42.6 million and t5 GW modules deployed around 1 nmentme raring„annm --- - -- — by SunPower for SunPower the world,SunPower technology Is proven to last.That's why we Na mad PROJECT NUMBER: AC modules stand behind our module and microlnverter with the industry's ee<ww.,nnpnw.a,,, mere refere"re In Please IN Wel,.lrmall.Ion lmtmalonl for d"a.. best 25-year Combined Power and Product Warranty. °:p7.z A,nPn.,e o." re Iv change rcmPInn NI r aP,,.em dead.aerw o <.tisoNP er 'o log,.EQUINOX and '^^ „ySUNIOWnm ad"M'pia M vduadi' r"of,m,.e,ernn,,.,.„w..wow ay.e"tCN tsa "'°.' 539973 RevB MODULE SPECSHEET n,.P January 2022 DESIGNER/CHECKED BY: SOLAROTIK SCALE:AS NOTED PAPER SIZE:17'c11" DATE:9/8/22 REV:A PV-6.0 SYSTEM INFORMATION DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W +r-x t 1 -.' �,,r a= r ( r MODULES: �, x ti e -r (13)SUNPOWER SPR M425-H-AC 425W s ;t,• ,a`�" `r p '�t 1 �,4.Yra.�,. ' INVERTER: ' (3)ENPHASE7H5 f. dery l.. _... •. BRANCH DETAILS: r�II11RR (13)ENPHASE - '• v. . �pq `• , 1 BRANCH OF 7 AC MODULES 1 1 1 BRANCH OF 6 AC MODULES `" • ENGINEER OF RECORD ,i,-fl C"^ ^er 1 •est ential Mountie:". • r -Residential Mounting System Simple and Fast Installation •Integrated module to rail grounding •Pre-assembled mid and end clamps Module`low Clamp and Rail Module.i End Clamp and Rag •Mid clamp ng mid clamp for easy placement `�' • amp width fac litates Beenri fi viiiiistainfiii ri Ira m d module spacing •Simple,predrllled rail splice •UL 2703 Listed integrated grounding Flexible Design 111111 I. •Addresses nearly all sloped residential roofs •Design in landscape and portrait MU Comp End(lamp Rag&Rail space Ground Lug Assemnt; [M Cap easy tacle •Rails enable referr dAesheticsent Customuleandf#1 mounting Aesthetics Olhe ri 1111111.4 •xi module and ut mounting aesthetics --'ff.fenkfe IE •Best-in-class system aesthetics Elegant Simplicity \ ``i . s •Premium,low-profile design 6 {Y/ r'd's •Black anodized components SunPower°InvlsiMount"'is a SunPower-designed •hidden mid clamps and end clamps rail-based mounting system.The InvisiMount system r a.eaal walgnl Taanperxure -+a•ccoso•c t-ao•Em tsn°n ENERGY S O L U T I ON 5 uplift End CI — -- hardware,and capped,Flush rails --- - Max.Load 2sno Pa r addresses residential sloped roofs and combines faster Mb o,m, w ix l ims Sea 63 g(22 ) .. __ ____ ____.._ ca _. 185 NEW BOSTON STREET, Part of Superior System File. on ed alloy 601 a•T6 t 0 g(3 Bg t _ WOBUFLN Installation time,design flexibility,and superior aesthetics. Bari n a k as d aluminum Clew 6005 T6 830On(9 rfu MA,01801 •Built for use with SunPoeser DC and AC modules as I spike Alummurn alloy 6005 T5 830 gin(9 m/td warrarnies 25ye productwarranty The lnvlsiMount product was specificalyenvisioned and le 5 a nnc w my CUSTOMER INFORMATION •BesElrndass system reliability and aesthetics Ground wf, 3da 1lw s 1 __, -- Hgm:3.2so1 engineered topair with SunPower modules.The resultinguaemmy ez_ro t ,.pwmd copper Rag •Combine with SunPower modules and 8 C -- - ----- uL 2703 Listed End Cap BM(k a[euallPOMl copolymer loA VP 37 uxl� monitoring app system-level approach will amplify the aesthetic and cervn(ane,s Crass A Ere rating when divancebeeii.n NAME&ADDRESS: .o<,rardaea and oamm nr wnpuwer installation benefits for both homeowners and Installers. module frame ias 3.5' AKSHAY DALAL -- -------- 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 c ppu SB g e retr —��— 41°64'30.3"N 70°20'72.2"W Pypliration •C sh gl o kra k g h ent •Curved and r+a r Roof n ,IJ//// wersal Int,(Jur frrr Other Roof n ms serer m roof mam ent hardware manufacturers d enrxlon AW:MA-BARNSTABLE sunpower.com OM a"i.r,ae maiscnepsrae n a» a I.n,m, nrMra �..«, P. s„^Pw..,o ,nnn.A.wgrna w. wsm.Powcz m.wmP°wtn ma as amanawn r.r.,,,n.an_a r E.. Pme.mar «rer�.a-a""ez PROJECT NUMBER: `swu" wu".,w.0»,mna.�,...r.wa.dme,r7Ma�,.rM..e ` oocurmx ��': SUNP W E R SUNP WE R RACKING SPECSHEET DESIGNER/CHECKED BY: SOLAROFIx SCALE:AS NOTED PAPER SIZE:1Tx11" DATE:9/8/22 REV:A PV-6.1 }\ § %} ! �� [! ƒ T 4 \} \ I& | �a ( !1 � O 0 \ �� 1 2 2 .k ! . } \ ., c. }\ 9. . . }\ 77 :I . ® : 2 � # { § - - \ r • \ - { 2 | . _ _ \ § i { \ \} }\ }\\ — 0 ,ram 5 >= .. 0 ¢! S § _ : - _ ; 0 \ \ , ` ( ¥ ( i , ! 3 l , 3l1f [ ( ? r 0« li \ .4 ( \ ••Re. a2 �� . \/ `5(� o { ( c z \ ; : -I } f.. - §j= . ` ( \ . . . 11/ ir : ! r R . . I = ! { g f\ . - _ ;;,:!§/ ~ ` 5 � ` I \ } \ Ro 1� \—�\ }\ /}},}\ ! g s - : � ; : . . e 2 ` / 2 � ~ 4:Ip _ —g AR ) ( k m n m (\k\\\/ V& 0 ` Qf § E $ a§ \ § Z[j§§ )� 2§0 co 2 ` i } k �• R�>u� § 3 ■ z )27 7J \33 § �3§ ` " »& z f j .. -o § § §§q § �' ?(m k» q § 7 ) \ CL rn n j 2 ) _ § � 0 $ •1 ! § ° 2 w ( 2 1 SYSTEM INFORMATION DC SYSTEM SIZE:5525W AC SYSTEM SIZE:4992W MODULES: (13)SUNPOWER SPR M425-H-AC 425W INVERTER: (13)ENPHASEIQ7HS D.-.1.,sloe! Enphase IQ Combiner 3 Enphase Networking MOREL NUMBER BRANCH DETAILS: 1 BRANCH OF 7 AC MODULES X-Gnmbmera production ductiner3terng((ANSI i0 Envoy.204/`printed d CH.,ptinal.cforumptianedormrinprase PV.5 X-IQ-AMr-240-3 peodueuun metering(ANSI C12.20 0/-0.5%)and opuonar consumption mor,mnng(01.2,5%). 1 BRANCH OF 6 AC MODULES ACCESSORIES and REPLACEMENT (not Included,orderaeparetey) __. ENGINEER OF RECORD ECELLM Mobile 3(4G/12- CELLMOOEM-01(3G/5-yeart dale ear date lan) Plug end play Irrdualliegrade ecellular,Canada, with for,and opt.60 CELLMODE 441(40/asedit'Mlt-yn) crre there is adeq ate c cellularn th<serviceatleMeeMllatio. en rflico,antl the US glrgin blares. CELLmption Mt(4Ging.CLTE-M/S�ertlna plan)w lit corec irr ederansf transformers nablle tn hole Installation area) The Enphase ID Combiner 3'"with Enphase Consumption Monitoring.CT Split core current trans/ormere enable whole bonus consumption metering HI-2.5%). Enphase I>hee p C-2OOSPLIT • w eCommunicw„nsKltrea ,y.� IQCombiner 3 IQEnvoy"consolidates interconnection Ensemble C0MMS-KIT-ot Communications Kil InstaEirpo led ancetr the witcEnvoh.For communicationseUs ble for conEnphase ntcIS Envoy storageEnphase 10 Combiner' equipment into a single enclosure and and po wirelesson0R10.BR2communication,BR20,wit 0230,Encha ge and00240 00250, Circuit Breakers Supports Eaton BR210,BR215,BR220.BR230,BP240,BR250,end BP260 circuit beakers. (X-IQ-AM1-240-3) streamlines PV and storage installations by BAN-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 providing a consistent,pre-wired solution for ORE20A-2P•240 Circuit breaker,2 pole,20.0,Eaton BR220 EPLC-01 Power tins carrier(communication bridge pair),quantity-one pair residential applications.It offers up to four XA-OOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the EnpMae Enpower"smart switch and the Enphase Encherge'storage system 2-pole input circuits and Eaton BR series XA.PLUG-120.3 Accessory receptacle for Power Line Carrier In IO Combiner 3(required for EPLC-01) busbar assembly. XA-ENV-PCBA-3 Replacement 10 Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busber rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Smart Branch circuits(solar and/or storage) Up to lour 2-pole Eaton BR series Distributed Generation(DG)breakers only(not Included) ° -- •Includes 10 Envoy for communication Max continuous current rating(input from PV) 64A R and control Mee.total branch circuit breaker rating(Input) BOA of distributed generation/95 A with IS Envoy breaker Included• • • • ,Y Flexible networking supports Wi Fi, 6 Envoy 0 aka 10A or 15AratingGEOline/SI Type OP/E ton BR series included ( as. FlnameLetce(IUIariridis 1 I� .'j .Optional AC receptacle available for PLC bridge Production Metering CT 200 A sad p 1 stalled and d to 10 Envoy T f -Provides production metering and optional consumption MECHANICAL DATA ENERGY SOLUTIONS 11 monitoring Dimensions(WeMeD) 495 x 37.5 x 168 cm(19.5"41475 e663').HegMM 21.06'(5350tn with mounting brackets). • `e 185 NEW BOSTON STREET, •Supports Ensemble Communications Kit for Weight 7.5 kg(16.51bs) communication with EEnphaee Encharge'storage and Ambient temperature range -40°CWN6°C(40°to true F) WCBURN a. Ivn.M Enpower amen switchMA,01801 Cooling Natural convection,plus heat shield Simple Enclosure environmental rating Outdoor,NRTL-cenlhed,NEMA type 3R,polycatbonsteconstruction CUSTOMER INFORMATION • Wire sizes •20 A to 50 A breaker inputs:14 to 4 AWG copper conductors •Reduced size from previous combiner •60 A breaker branch Input 4 to 1/0 AWG copper conductors •Centered mounting brackets support single stud •Main lug combined output 10 to 2/0 AWG copper conductors NAME&ADDRESS: •Neutral and ground: 0 copper conductor, mountingAlways follow local code requirements for conductor sizing. AKSHAY DALAL •Supports back and side conduit entry Altitude To 2000 meters(6560 feet) 37 SHORESIDE DR,SOUTH YARMOUTH,MA 02664 •Up to four 2-pole branch circuits for 240 VAC plug-in INTERNET CONNECTION OPTIONS 41°64'30.3"N 70°20'72.2"W beakers(not included) IMeyrated WI-Fl 802.11b/y/n •84 A total PV or storage branch circuits Ethernet Optional,802.3,CatSE(or Cet 6 UT Ethernet cable p ) not included) Cellular CELLMOOEM-Ml 4o based LTE-M cellular modem(not Included).Note that an Enphase Mobile Reliable Connect cellular modem is required for aBinnsemble inafellabons. AFU:MA-BARNSTABLE •Durable NRTL-certified NEMA type COMPLIANCE 3R enclosure Compliance,Combiner UL 1741 CAN/CSA C22,2 No 1071 47 CFR,Part 15 Class B,ICES 003 •Ronyear limited warranty ca Production metering ANSI accuracy classOS(PV production) 0Complbn 10E y _ UL 60601_t/CANCSA 22.2 No.61 fi10101 •UL I'sted LINED to team more Roout enpnese merino,vise Ram.00m PROJECT NUMBER: To learn more about Enphase Offerings,visit pBpLl_ase.com ENPHASE .2021Enphe Energy rights E Nose.ire Enyuaoe tools i0cnrnOwer3,and Nneraenemaooct swag naves antl.* `j ENPHASE mderen a EngraaeEegv,Inc Data 6.,ed to cnanot.2021.05-20 ENPHASE IQ COMBINER 3 DESIGNER/CHEO(ED BY: SOLAROFIX SCALE:AS NOTED PAPER SIZE:1TX11" DATE:9/8/22 REV:A PV-6.3 0