Loading...
HomeMy WebLinkAboutBLDE-23-001674 Commonwealth of Official use only or 14.7711 '; Massachusetts Permit No. BLDE-23-001674 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:9/28/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 8 WARBLER LN Owner or Tenant CARLENE SMITH Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (20 Panels 7.100 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Ton l No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER: I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 r k55 111412-Z RF C D Commonwealth 0/Massachusetts Official Use On 1,1 =*= cc��r� cc77 Permit No. -Z"A(1 _ l (6 ..LJepartment of.}ire�ervices �='s42i E t Occupancyand Fee Checked SEP •��__�_ BI ARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) By _BUILDING DEPARTMEN , TION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: O / a(aI 2jOa a City or Town of: yarrnoo4#- To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street& Number) 8 WO.X 131.ex Lin Owner or Tenant Car\eat 5(fl t Telephone No. 5 ,1e1 5(d-+LBO() Owner's Address 5f p ri24, cuonv( Is this permit in conjunction with a building permit? Yes a No n (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service I 00 Amps l at / 2L OVolts Overhead V , Undgrd n No.of Meters New Service Amps / Volts Overhead n Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: hniptla+vIn U,F Qn nit -corlinec+td f-00F to e 9 J Sts+c - aO p a -7.i Oov-IV.J Completion of the following table may be waived by the Inspector of Wires. Total No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones of No.of Switches No.of Gas Burners No. Initiatinnggon Dete and In Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW iLocal ElMunicipal DI OtherConnection No.of Dryers Heating Appliances KW Security Systems:* '3 No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications NofDeieor Y g No.of Devices Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: q cociz .oo (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE IN BOND El OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.NO.:4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136A (If applicable, enter "exempt"in the license number line.) Bus.Tel.No.:978-594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)El owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:7100W DC,6000W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SOLAR MODULES •MODULES:(20)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE PV-1.0 COVER SHEET LTD:LR4-6OHPB-355M INSTRUCTIONS. INIlJ o- o ----- -o-------❑ PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. SE6000H-USSN MP MAIN PANEL PV-3.0 LAYOUT •RACKING'.RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL SEE DETAIL SNR-DC-00436 •- SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL - SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER I� Iti' CHIMNEY ---- •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. E'\ ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER E 1 FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. •.• PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). lAC I AC DISCONNECT(S) SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC •11.25 AMPS MODULE SHORT CIRCUIT CURRENT. E=I DC DISCONNECT(S) FIRE SETBACKS •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. CB IQ COMBINER BOX -. j HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). ' -•_-' CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE INTERIOR EQUIPMENT —PL— PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE:NTS A AMPERE sunrun AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 Bayberry Hills BI (E) EXISTING 666 MYlEs srAJDISH BLvo,TAUNTON,MA,onso,6x+ y yOld Town ESS ENERGY STORAGE SYSTEM FAX PHONE Golf Course House Park 6 EXT EXTERIOR r�,� 9 INT INTERIOR CUSTOMER RESIDENCE: { MAG MAGNETIC CARLENE SMITH Sy MSP MAIN SERVICE PANEL 8 WARBLER LN,YARMOUTH, did (N) NEW MA,02673 NTS NOT TO SCALE 9DZ. N OC ON CENTER TEL(508)364-4300 o 108 Warbler Ln, PRE-FAB PRE-FABRICATED APN:YARM-000076-000133 PSF POUNDS PER SQUARE FOOT 7 West Yarmouth,MA... PV PHOTOVOLTAIC PROJECT NUMBER: a RSD RAPID SHUTDOWN DEVICE 223R-008SMIT TL TRANSFORMERLESS DESIGNER: (415)580-6920 ex3 TYP TYPICAL V VOLTS SUPARNA MALIK ''' W WATTS SHEET • REV NAME DATE COMMENTS COVER SHEET REV:A 9/25/2022 ,s,k p,.c, " Psr,c, () ,,S' PAGE PV-1.0 . v .A t-t'a ,1 ARRAY TRUE MAG PVAREA SITE PLAN-SCALE=1/16"=1'-0" PITCH AZIM AZIM (SOFT) AR-01 30° 176' 190' 333.4 tli AR-02 30° 176' 190' 58.8 FO, 0 O PM INV PL L - a PL P 1 \----------- \-- (E)RESIDENCE— - Mill 6•.! . MIIIIIMIIIIIIIIIII Mill a ; iiii athillull Nil ° °� sunrun #180120 695 MYLES STNOSH BLVD,TMMTON.MA.07/1107331 PHONE FA[0 CUSTOMER RESIDENCE: \ \ (N)ARRAY AR-02 I--(N)ARRAY AR-01 4- CARLENE SMITH 8 WARBLER LN,YARMOUTH, MA,02673 TEL.(508)364-4300 Pt PL _� APN:YARM-000076-000133 \_______ -- PL PROJECT NUMBER: PL WARBLER LN 223R-008 MIT DESIGNER: (415)580.6920 ex3 SUPARNA MALIK SHEET SITE PLAN REV.A 9/25/2022 PAGE PV-2.0 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF g yp Detail OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 10'-9" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 10'- 24„ RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 4'-0" 2'-0" STAGGERED 5116":2.5"MIN EMBEDMENT 10" COMP,SEE DETAIL SNR-DC-00436 STRUCTURAL NOTES: • INSTALLERS SHALL NOTIFY D1-AR-01-SCALE:3/16"=1'-0" ENGINEER OF ANY POTENTIAL AZIM:176° -}2'-3" -. - 40'-8" , 3'-1" ( STRUCTURAL ISSUES PITCH:30° OBSERVED PRIOR TO PROCEEDING W/ _ 1'-6" INSTALLATION. 11M2 • IF ARRAY(EXCLUDING SKIRT)REGIONIS WITHIN 12"BOUNDARY M .. - • OF ANY ROOF EDGES(EXCEPT VAALLLEYS)NE THEN ATTACHMENTS NEED • TO BE ADDED ANO OVERHANGS y-� 10'-4 REDUCED WITHIN THE 12" - _ _ _ _ _ BOUNDARY REGION ONLY AS FOLLOWS: r ••ALLOWABLE ATTACHMENT • SPACING INDICATED ON PLANS TO BE REDUCED BY , 50% ••ALLOWABLE OVERHANG 2'-10" INDICATED ON PLANS TO BE • 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS D2-AR-02-SCALE:1/4"=1'-0" AZIM:176° s u n r u n PITCH:30° {— 14'8" — 5'-9"---11"} 1,-6„ __—___ti #180120 695 MYIES STANDISH BLVD,TAUNTON.MA,02780 7331 "NONE0 FAX 0 CUSTOMER RESIDENCE: [1] = CARLENE SMITH 8 WARBLER LN,YARMOUTH, MA,02673 10'4" — STRUCT TEL.(508)364-4300 _ — _ ONL CARLENE YARM-000076-000133 a��.ItN OFM4SS9 o cy PROJECT NUMBER: F� VINCENT ��, 223R-008SMIT cr MWUMVANEZA ,, CIVIL DESIGNER: (415)580-6920 ex3 N°. 2 111—_ e SUPARNA MALIK % Naga 1,-8„ ONRIENr SHEET LAYOUT REV:A 9/25/2022 SEE SITE PLAN FOR NORTH ARROW 18,$„ PAGE PV-3.0 ._ _. 4 120/240 VAC SINGLE PHASE SERVICE METER#: O EVERSOURCE 2289733 NOTE:TOTAL PV BACKFEED=31A UTILITY USED FOR INTERCONNECTION GRID I CALCULATIONS / -SUPPLY SIDE TAP c_ (N)LOCKABLE I EXISTING 100A BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: DISCONNECT REVENUE SE6000H-USSN I METER 6000 WATT INVERTER JUNCTION BOX PV MODULES �� CZ� OR EQUIVALENT EXISTING 3 A C) LONGI GREEN ENERGY TECHNOLOGY — AAAAJ 1J // CO LTD:LR4 60HPB 355M 100A MAIN to, _ A f ��i _ �_ + / (20)MODULES is PANEL M ___ OPTIMIZERS WIRED IN: FACILITY 35A FUSES I i 1 (1)SERIES OF(10)OPTIMIZERS LOADS- -zG ouHo SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT L (1)SERIES OF(10)OPTIMIZERS D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT P401 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE k CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 805 MOLES STANDISH BLVD.TAUNTON.MA,02700 7331 RIPE 0 AAx o CUSTOMER RESIDENCE: CARLENE SMITH 8 WARBLER LN,YARMOUTH, MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)364-4300 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000076-000133 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4.60HPB-355M: 355 W MAX INPUT ISC: 11.75 ADC 223R-008SMIT OPEN CIRCUIT VOLTAGE: 40.6 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE: 34.6 V SHORT CIRCUIT CURRENT: 11.25 A DESIGNER: (415)580-8920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SUPARNA MALIK SYSTEM SIZE: 7100 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 10 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE: 480 V REV:A 9/25/2022 SYSTEM OPERATING CURRENT: 18.68 A SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 , /TWA R N I N G INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ELECTRICAL SHOCK HAZARD ik' PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS,COLORS AND SYMBOLS. TERMINALS ON LINE AND LOAD •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2020:690.53 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING , POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PER CODE(S):CEC 2019:690.31(G)(3),690.31(G)(4), SYSTEM NEC 2017:690.31(G)(3),690.31(G)(4)IFC 2012: 605.11.1.4 LABEL LOCATION: CAUTION : UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020:705.12(C) AWARNING MULTIPLE SOURCES OF POWER PER SOURCE OUTPUT CONNECTIONIIDSHUTDOWNSWITCH R SOLAR PV SYSTEM SOLAR PANELS ON ROOF- DO NOT RELOCATE THIS1 Ilk OVERCURRENT DEVICE LABEL LOCATION: INSTALLED WITHIN(3'ONECRAPID SHUT DOWN LABEL LOCATION: SWITCH PER CODE(S):20):NC 2020:890.58(C)(2),IFC V �— s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3 OCPD(IF APPLICABLE). — PER CODE(S):NEC 2020: _ 705.12(B)(3)(2) AWARNING SOLAR PV SYSTEM EQUIPPED #180120 695 MYIES STANOSH 9LVD,TAUNTON,MA,027604331 PHOTOVOLTAIC SYSTEM WITH RAPID SHUTDOWN COMBINER PANEL FAX PHONED DO NOT ADD LOADS MAIN CUSTOMER RESIDENCE: CARLENE SMITH LABEL LOCATION: PANEL(I N T) 8 WARBLER LN,YARMOUTH, PHOTOVOLTAIC AC COMBINER OF APPLICABLE). 3" TURN RAPID SHUTDOWN MA,02673 PER CODE(S):NEC 2020:705.12(0)(2)(3)(c) SWITCH TO THE"OFF" ro.ELs TEL(508)364-4300 POSITION TO SHUT DOWN APO:YARM-000076-000133 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE INVERTER (EXT)- -SERVICE ENTRANCE PROJECT NUMBER: SHOCK HAZARD I"THE PV PRODUCTION FUSED AC MAXIMUM AC OPERATING CURRENT:25_00 AMPS ARRAY. MA 223R-OOBSMIT NOMINAL OPERATING AC VOLTAGE: 240 VAC METER DISCONNECT DESIGNER: (415)580-6920 ex3 LABEL LOCATION: SUPARNA MALIK AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF 8 WARBLER LN, YARMOUTH, MA, 02673 INTERCONNECTION. SHEET PER CODE(S):NEC 2020:690.54 LABEL LOCATION: PER CODE(S):NEC 2020:705.10,710.10 S I G NAG E ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 9/25/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0