HomeMy WebLinkAboutBLDE-23-002824 Commonwealth of Official Use Only �.AN% Massachusetts Permit No. BLDE-23-002824 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:11/21/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 1 MAYFLOWER LN Owner or Tenant MAUREEN BROWN Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (9 Panels 3.240 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number , Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 LCit t.„ rg , r RECEIVED NOV 21202X lth / h Official Use Only o aea i o abbac u6et14 * . -gt �/ YRp 'a DEII PARTM EPARTM ','/�`rtment of }ire Services Permit No. V...-5 -:2-462.)k - Occupancy and Fee Checked e `I l :• ' - • • 'R EVE NTION REGULATIONS [Rev. 1/07j,o+ (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: » I 1 a ( 3,2 City or Town of: `f arYY\GU1 To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) Owner or Tenant -I-A-A I Telephone No.,C)pt) 3-1 F�/ ' Owner's Address c Q k J& Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building/, ^ Utility Authorization No. SExisting Service l 00 Amps (� /p((46 Volts Overhead ® Undgrd n No.of Meters (13 New Service Amps / Volts Overhead❑ Undgrd No.of Meters Number of Feeders and Ampacity ) Location and Nature of Proposed Electrical Work: ' e �l s4z,vc,m 9 oct rLu 3 . vr, Completion of the followin&table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Pool Above ❑ In- ❑ No.of Emergency Lighting 0- No.of Luminaires Swimming grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones E No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW _No.of Self-Contained dTotals: Detection/Alerting Devices O) No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection Security Systems: No.of Dryers Heating Appliances KNN No.of Devices or Equivalent * No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: ri (�� `�? Attach additional detail if desired,or as required by the Inspector of Wires. 9 Estimated Value of Electrical Work: 1`l 3 .aJ (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services LIC.N0.:4316 Al Licensee: Nathan Ashe Signature fir LIC.NO.:21136A (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:976 594-3519 Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. tOWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally . required by law. By my signature below,I hereby waive this requirement. I am the(check one)E owner ❑owner's agent. Owner/Agent [PERMIT FEE: $ Signature Telephone No. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION M •SYSTEM SIZE:3240W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), SERVICE ENTRANCE •MODULES:(9)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION PV-1.0 COVER SHEET 2.11g LTD:LR4-60HPH-360M INSTRUCTIONS. PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. MP MAIN PANEL SE3800H-USMN PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL 0 SUB-PANEL SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). AC I AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. O DC DISCONNECT(S) •11.35 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •17,73 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2). ABBREVIATIONS I 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT S u n run AFC ARC FAULT CIRCUIT INTERUPTER �,` CHIMNEY AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 IEI EXISTING FLUSH ATTIC VENT VICINITY MAP OBS MYLES STANDISH BLVD,TAUNTON MA 02]B6)331 ESS ENERGY STORAGE SYSTEM c PVC PIPE VENT „ '" PHONED FAX 0 EXT EXTERIOR N METAL PIPE VENT . • CUSTOMER RESIDENCE: INT INTERIOR MSP MAIN SERVICE PANEL - T-VENT MAYFLOWER LN,YARMOUTH, (N) NEW SATELLITE DISH MA,02664 M NTS NOT TO SCALE TEL.(508)371-7500 OC ON CENTER FIRE SETBACKS APN:YARM-000060-000064 PRE-FAB PRE-FABRICATED PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE - - 223R-001 BROW PV ,PHOTOVOLTAIC •� 9 DESIGNER: (415)580-6920 ex3 RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE ,,, AMAN SONI TL TRANSFORMERLESS [_--SOLAR MODULES '� � ' SCALE:NTS SHEET YP TYPICALG I G q ��� REV NAME DATE COMMENTS COVER SHEET ✓ VOLTS -_ « ";Y. , Hy YARt.1GUi W WATTS IA jar"A t� �"'''',:-I NEST 1iFF J',,��', - REV:A 11/16/2022 8 qq LAN LANDSCAPE Il SNR MOUNT - -- LAN PORTRAIT S "•'` PAGE PV-1.0 PORSNR MOUNT&SKIRT li;( ...�' _. lirrempale_v n_a 0 el SITE PLAN-SCALE=1/16"=1' T ICJ a ------..........\ (E)RESIDENCE--- Q` w (N)ARRAY AR-01-- MAYFLOWER LN W / w '..-----..-- . ( . _ : , : 5 e** (N)ARRAY AR-02 ♦♦ 1 l*,*° sunrun #180120 G^ ' 885 MYLES 9TANDISM BLVD,TAl1MON,MA,0]i80-]331 P PHONE O FAX / Q' ". / CUSTOMER RESIDENCE: MAUREENAUREENBRO 9, 1 MAYFLOWER LN,YARMOUTH, MA,02664 MP CA ' AC ARRAY TRUE MAG PV AREA TEL.(606) -000000 a_ SE 0 PM tNV PITCH AZIM AZIM (SOFT) APN:YARM-000060-000064 AR-01 33° 246° 262° AR-02 30° 246° 262° 78.4 ` PROJECT NUMBER: _ 223R-0018ROW P� 98 a° DESIGNER: (a/5)580-6920 ex3 -. AMAN SONI SHEET SITE PLAN REV:A 11/16/2022 PAGE PV-2.0 I e maa te_ve.s,on_a 0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA • Max OC Max Landscape Max Landscape Max Portrait Max Portrait ' MAX DISTRIBUTED LOAD:3 PSF Name Type Height Type Span Spacing Detail OC SpacingOverhangOC Spacing Overhang Configuration P 9 P 9 9 SNOW LOAD:30 PSF • RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 5'-11" 18" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 6'-1" 18" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 5/16":2 5"MIN.EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" INSTALLERS SHALL NOTIFY AZIM:248° ENGINEER OF ANY POTENTIAL PITCH:33° STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING WI INSTALLATION. ----12'-7" 11'-7" 14'-10" IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY SKIRT) I REGION OF ANY ROOF PLANE .,......_...-.....-..__..-._...._....__...._._--_-- EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG 6'-10" REDUCED WITHIN THE 12" ❑ BOUNDARY REGION ONLY AS FOLLOWS: "ALLOWABLE ATTACHMENT 4'-3" 4'-8" SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. "ALLOWABLE OVERHANG -,2'-8", INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. D2-AR-02-SCALE:3/16"=1'-0" AZIM:248° s u n r u n PITCH:30° 3'-11" 17-5" .---- , #180120 1-6„ 6.MYLEB STANDISH BLVD,TAUMIXJ.MA,WW1. F.xo CUSTOMER RESIDENCE: MAUREEN BROWN • I.- 1 MAYFLOWER LN,YARMOUTH, 2,-8„ MA,02664 STRUCT 1O'-4" ., • TEL.(508)371-7500 ONL 0��.0 of Mqy.si 6'-11" j _ _ APN:YARM-000060-000064 oy PROJECT NUMBER: o G 4' VINCENT �' g MWUMVANEZA H 223R-001BROW CIVIL NLi 2 , •-......-...__—_- • •. ...._...--- DESIGNER: (415)580.6920 ex3 .. : .*." 4::e I 2,�9„ AMAN SONI ONALbN f I SHEET 1--,-- LAYOUT 1,4„-i I REV:A 11/16/2022 ,... ----11'-8"------ l' PAGE PV-3.0 i rnrp.r w.oe_ao.er 1 120/240 VAC SINGLE PHASE SERVICE METER#: OEVERSOURCE 2290877 NOTE:TOTAL PV BACKFEED=20A UTILITY USED FOR INTERCONNECTION GRID CALCULATIONS / 1 1 EXISTING 100A \T BREAKER V LOAD SIDE TAP (N)LOCKABLE BLADE TYPE (N)MA SMART FUSED AC UTILITY SOLAR EDGE TECHNOLOGIES: I SE3800H-USMN REVENUE I EXISTING 100A METER 3800 WATT INVERTER JUNCTION BOX PV MODULES 3 (3) 3 (2') 2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY C 3) � � A // CO LTD:LR4-6OHPH-360M J MAIN BREAKER �.o. O O v _ �•� — -- +("1:)/ (9)MODULES Y OPTIMIZERS WIRED IN: EXISTING 100A 20A FUSES I I (1)SERIES OF(9)OPTIMIZERS / MAIN PANEL SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT t D221NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS FACILITY 3R,30A UTILITY SIDE OF CIRCUIT COMPLIANT S440 LOADS l=. 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE GENERAL NOTES: # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 995 MOLES STANDISH BLVD,TAUNTON,MA,DAI50.73S1 PHONED FAX 0 CUSTOMER RESIDENCE: MAUREEN BROWN 1 MAYFLOWER LN,YARMOUTH, MA,02664 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)371-7500 LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000060-000064 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER: LR4-60HPH-360M: 360 W MAX INPUT ISC: 11.75 ADC 223R-001 BROW OPEN CIRCUIT VOLTAGE: 40.5 V MAX POWER VOLTAGE: 34 V MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3 SHORT CIRCUIT CURRENT: 11.35 A AMAN SONI SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 3240 W SHEET SYSTEM OPEN CIRCUIT VOLTAGE: 9 V ELECTRICAL SYSTEM OPERATING VOLTAGE: 380 V MAX ALLOWABLE DC VOLTAGE 480 V REV:A 11/16/2022 SYSTEM OPERATING CURRENT: 8.53 A SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0 Template vervon_40 B7 AWARNING INVERTER I NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 460 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD MAXIMUM SHORT CIRCUIT CURRENT: ElADC WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S), AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWSE SPECIFIED. AC COMBINER PANEL OF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC AWARNING POWER SOURCE LABEL LOCATION: DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. AND PV SOLAR ELECTRIC PERCODE(S):NEC 2020:690.31(0)(2),IFC 2012: SYSTEM 605.11.1.4 CALITIONE LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. ■ PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SwIT • MULTIPLE SOURCES OF POWER AWARNING 401 POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTE SOLAR PANELS ON ROOF- DO NOT RELOCATE THIS e' OVERCURRENT DEVICE LABEL LOCATION: 111 �'�,w INSTALLED WTHIN 3'OF RAPID SHUT DOWN AL LOCATION: 2012:60 PER CODE(S):NEC 2.5.3 690.58(C)(2),IFC , s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2016:1204.5.3 OCPD(IF APPLICABLE). ir PER CODE(S):NEC 2020, 4• 705.12(8)(3)(2) " AWARNING SOLAR PV SYSTEM EQUIPPED Lill aleolzo 4 ■ sss u s sr,woisH BLVD.rr,uvrorv,Mn,OEM,.P"DTDVDLTAIC SYSTEM WITH RAPID SHUTDOWN COMBINER PANEL Paco DO NOT ADD LOADS CUSTOMER RESIDENCE: LABEL LOCATION: MAUREEN BROWN PHOTOVOLTAIC AC COMBINER(IF 1 MAYFLOWER LN,YARMOUTH, L 3" MAIN PANEL L MA,02664 PER CODE(S):NEC 2020:705.12(0)(2)(3)(c) TURN RAPIDSHUTDOWNSWITCH TO THE"OFF" SERVICE ENTRANCE INVERTER (EXT) TEL.(506)371-7500 POSITION TO SHUT DOWN —PRODUCTION APN:YARM-000060-000064 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT) METER PROJECT NUMBER: SHOCK HAZARD IN THE MAXIMUM AC OPERATING CURRENT:15.83 AMPS ARRAY. II 223R-001 BROW NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580-6920 ex3 LABEL LOCATION: 1 MAYFLOWER LN, YARMOUTH, MA, 02664 AMANSONI AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF l INTERCONNECTION. PER CODE(S):NEC 2020:690.54 LABEL LOCATION: SHEET ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 11/16/2022 PER CODE(S):NEC 2020:690.56(C) PAGE PV-5.0 C Tompab h/tlon 4.0 8]