APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:11/21/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 1 MAYFLOWER LN
Owner or Tenant MAUREEN BROWN Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (9 Panels 3.240 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number , Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
LCit t.„ rg
,
r RECEIVED
NOV 21202X lth / h Official Use Only
o aea i o abbac u6et14
* . -gt �/
YRp 'a DEII
PARTM EPARTM ','/�`rtment of }ire Services Permit No. V...-5
-:2-462.)k
- Occupancy and Fee Checked
e `I l :• ' - • • 'R EVE NTION REGULATIONS [Rev. 1/07j,o+ (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: » I 1 a ( 3,2
City or Town of: `f arYY\GU1 To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)
Owner or Tenant -I-A-A I Telephone No.,C)pt) 3-1 F�/
' Owner's Address c Q k J&
Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box)
Purpose of Building/, ^ Utility Authorization No.
SExisting Service l 00 Amps (� /p((46 Volts Overhead ® Undgrd n No.of Meters
(13 New Service Amps / Volts Overhead❑ Undgrd No.of Meters
Number of Feeders and Ampacity
) Location and Nature of Proposed Electrical Work: '
e �l s4z,vc,m 9 oct rLu 3 . vr,
Completion of the followin&table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
Pool Above ❑ In- ❑ No.of Emergency Lighting
0- No.of Luminaires Swimming grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
E No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total Tons No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW _No.of Self-Contained
dTotals: Detection/Alerting Devices
O) No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
Security Systems:
No.of Dryers Heating Appliances KNN
No.of Devices or Equivalent
*
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
ri (�� `�? Attach additional detail if desired,or as required by the Inspector of Wires.
9 Estimated Value of Electrical Work: 1`l 3 .aJ (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services LIC.N0.:4316 Al
Licensee: Nathan Ashe Signature fir
LIC.NO.:21136A
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:976 594-3519
Address: 695 Myles Standish BLVD Taunton MA 02780 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
tOWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
. required by law. By my signature below,I hereby waive this requirement. I am the(check one)E owner ❑owner's agent.
Owner/Agent [PERMIT FEE: $
Signature Telephone No.
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE# DESCRIPTION M •SYSTEM SIZE:3240W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
SERVICE ENTRANCE •MODULES:(9)LONGI GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
PV-1.0 COVER SHEET 2.11g
LTD:LR4-60HPH-360M INSTRUCTIONS.
PV-2.0 SITE PLAN •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
MP MAIN PANEL SE3800H-USMN
PV-3.0 LAYOUT •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
PV-4.0 ELECTRICAL 0 SUB-PANEL SEE DETAIL SNR-DC-00436
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
AC I AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
O DC DISCONNECT(S)
•11.35 AMPS MODULE SHORT CIRCUIT CURRENT.
CB IQ COMBINER BOX •17,73 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)].
•PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2).
ABBREVIATIONS I 1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
A AMPERE
L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT S u n run
AFC ARC FAULT CIRCUIT INTERUPTER �,` CHIMNEY
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT #180120
IEI EXISTING FLUSH ATTIC VENT VICINITY MAP
OBS MYLES STANDISH BLVD,TAUNTON MA 02]B6)331
ESS ENERGY STORAGE SYSTEM c PVC PIPE VENT „ '" PHONED
FAX 0
EXT EXTERIOR N METAL PIPE VENT .
• CUSTOMER RESIDENCE:
INT INTERIOR
MSP MAIN SERVICE PANEL - T-VENT MAYFLOWER LN,YARMOUTH,
(N) NEW SATELLITE DISH MA,02664
M
NTS NOT TO SCALE
TEL.(508)371-7500
OC ON CENTER FIRE SETBACKS
APN:YARM-000060-000064
PRE-FAB PRE-FABRICATED PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT HARDSCAPE - - 223R-001 BROW
PV ,PHOTOVOLTAIC •� 9
DESIGNER: (415)580-6920 ex3
RSD RAPID SHUTDOWN DEVICE —PL— PROPERTY LINE ,,,
AMAN SONI
TL TRANSFORMERLESS [_--SOLAR MODULES '� � '
SCALE:NTS SHEET
YP TYPICALG I G q ��� REV NAME DATE COMMENTS COVER SHEET
✓ VOLTS -_ « ";Y. ,
Hy YARt.1GUi
W WATTS IA jar"A t� �"'''',:-I NEST 1iFF J',,��', - REV:A 11/16/2022
8
qq
LAN LANDSCAPE Il SNR MOUNT - --
LAN PORTRAIT S "•'` PAGE PV-1.0
PORSNR MOUNT&SKIRT li;( ...�' _.
lirrempale_v n_a 0 el
SITE PLAN-SCALE=1/16"=1'
T
ICJ
a ------..........\
(E)RESIDENCE--- Q`
w
(N)ARRAY AR-01--
MAYFLOWER LN
W
/
w
'..-----..-- . ( . _ : , :
5
e**
(N)ARRAY AR-02 ♦♦
1
l*,*°
sunrun
#180120
G^ ' 885 MYLES 9TANDISM BLVD,TAl1MON,MA,0]i80-]331
P PHONE O
FAX
/ Q'
". / CUSTOMER
RESIDENCE:
MAUREENAUREENBRO
9, 1 MAYFLOWER LN,YARMOUTH,
MA,02664
MP
CA
' AC ARRAY TRUE MAG PV AREA TEL.(606) -000000
a_ SE 0 PM tNV PITCH AZIM AZIM (SOFT) APN:YARM-000060-000064
AR-01 33° 246° 262°
AR-02 30° 246° 262° 78.4 ` PROJECT NUMBER:
_ 223R-0018ROW
P� 98
a° DESIGNER: (a/5)580-6920 ex3
-. AMAN SONI
SHEET
SITE PLAN
REV:A 11/16/2022
PAGE PV-2.0
I e maa te_ve.s,on_a 0.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
•
Max OC Max Landscape Max Landscape Max Portrait Max Portrait ' MAX DISTRIBUTED LOAD:3 PSF
Name Type Height Type Span Spacing Detail OC SpacingOverhangOC Spacing Overhang Configuration
P 9 P 9 9 SNOW LOAD:30 PSF
•
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 5'-11" 18" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREW
AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 6'-1" 18" RL UNIVERSAL,SPEEDSEAL TRACK ON 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 5/16":2 5"MIN.EMBEDMENT
COMP,SEE DETAIL SNR-DC-00436
D1-AR-01-SCALE:1/8"=1'-0" INSTALLERS SHALL NOTIFY
AZIM:248° ENGINEER OF ANY POTENTIAL
PITCH:33° STRUCTURAL ISSUES OBSERVED
PRIOR TO PROCEEDING WI
INSTALLATION.
----12'-7" 11'-7" 14'-10" IF ARRAY(EXCLUDING SKIRT)
IS WITHIN 12"BOUNDARY
SKIRT)
I REGION OF ANY ROOF PLANE
.,......_...-.....-..__..-._...._....__...._._--_-- EDGES(EXCEPT VALLEYS),THEN
ATTACHMENTS NEED TO BE
ADDED AND OVERHANG
6'-10" REDUCED WITHIN THE 12"
❑ BOUNDARY REGION ONLY AS
FOLLOWS:
"ALLOWABLE ATTACHMENT
4'-3" 4'-8" SPACING INDICATED ON PLANS
TO BE REDUCED BY 50%.
"ALLOWABLE OVERHANG
-,2'-8", INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS.
D2-AR-02-SCALE:3/16"=1'-0"
AZIM:248° s u n r u n
PITCH:30°
3'-11" 17-5" .---- ,
#180120
1-6„ 6.MYLEB STANDISH BLVD,TAUMIXJ.MA,WW1.
F.xo
CUSTOMER RESIDENCE:
MAUREEN BROWN
• I.- 1 MAYFLOWER LN,YARMOUTH,
2,-8„
MA,02664
STRUCT 1O'-4"
., •
TEL.(508)371-7500
ONL 0��.0 of Mqy.si 6'-11" j _ _ APN:YARM-000060-000064
oy PROJECT NUMBER:
o G
4' VINCENT �'
g MWUMVANEZA H 223R-001BROW
CIVIL
NLi 2 , •-......-...__—_- • •. ...._...--- DESIGNER: (415)580.6920 ex3
.. : .*." 4::e I 2,�9„ AMAN SONI
ONALbN f
I SHEET
1--,-- LAYOUT
1,4„-i I REV:A 11/16/2022
,... ----11'-8"------ l' PAGE PV-3.0
i
rnrp.r w.oe_ao.er
1
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
OEVERSOURCE 2290877 NOTE:TOTAL PV BACKFEED=20A
UTILITY USED FOR INTERCONNECTION
GRID CALCULATIONS
/
1 1 EXISTING 100A
\T BREAKER
V
LOAD SIDE TAP
(N)LOCKABLE
BLADE TYPE (N)MA SMART FUSED AC UTILITY SOLAR
EDGE TECHNOLOGIES:
I SE3800H-USMN
REVENUE
I EXISTING 100A METER 3800 WATT INVERTER JUNCTION BOX PV MODULES
3 (3) 3 (2')
2 OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY
C 3) � �
A // CO LTD:LR4-6OHPH-360M
J MAIN BREAKER �.o. O O v _ �•� — -- +("1:)/ (9)MODULES
Y OPTIMIZERS WIRED IN:
EXISTING 100A 20A FUSES I I (1)SERIES OF(9)OPTIMIZERS
/ MAIN PANEL SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT
t
D221NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN SOLAREDGE POWER OPTIMIZERS
FACILITY 3R,30A UTILITY SIDE OF CIRCUIT COMPLIANT S440
LOADS l=. 120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE GENERAL NOTES:
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n
3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
995 MOLES STANDISH BLVD,TAUNTON,MA,DAI50.73S1
PHONED
FAX 0
CUSTOMER RESIDENCE:
MAUREEN BROWN
1 MAYFLOWER LN,YARMOUTH,
MA,02664
MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: TEL.(508)371-7500
LONGI GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC APN:YARM-000060-000064
TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
LR4-60HPH-360M: 360 W MAX INPUT ISC: 11.75 ADC
223R-001 BROW
OPEN CIRCUIT VOLTAGE: 40.5 V
MAX POWER VOLTAGE: 34 V MAX OUTPUT CURRENT: 15 ADC DESIGNER: (415)580-6920 ex3
SHORT CIRCUIT CURRENT: 11.35 A
AMAN SONI
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 3240 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 9 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE 480 V
REV:A 11/16/2022
SYSTEM OPERATING CURRENT: 8.53 A
SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE PV-4.0
Template vervon_40 B7
AWARNING INVERTER I NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
ELECTRICAL SHOCK HAZARD IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 460 VDC
•SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD MAXIMUM SHORT CIRCUIT CURRENT: ElADC WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WRING
METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),
AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWSE SPECIFIED.
AC COMBINER PANEL OF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
AWARNING POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PERCODE(S):NEC 2020:690.31(0)(2),IFC 2012:
SYSTEM 605.11.1.4
CALITIONE
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL. ■
PER CODE(S):NEC 2020:705.12(C) RAPID SHUTDOWN SwIT •
MULTIPLE SOURCES OF POWER
AWARNING 401
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTE SOLAR PANELS ON ROOF-
DO NOT RELOCATE THIS e'
OVERCURRENT DEVICE LABEL LOCATION: 111
�'�,w
INSTALLED WTHIN 3'OF RAPID SHUT DOWN
AL LOCATION:
2012:60 PER CODE(S):NEC 2.5.3 690.58(C)(2),IFC , s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2016:1204.5.3
OCPD(IF APPLICABLE). ir
PER CODE(S):NEC 2020, 4•
705.12(8)(3)(2) "
AWARNING SOLAR PV SYSTEM EQUIPPED Lill
aleolzo
4 ■ sss u s sr,woisH BLVD.rr,uvrorv,Mn,OEM,.P"DTDVDLTAIC SYSTEM WITH RAPID SHUTDOWN
COMBINER PANEL Paco
DO NOT ADD LOADS
CUSTOMER RESIDENCE:
LABEL LOCATION:
MAUREEN BROWN
PHOTOVOLTAIC AC COMBINER(IF 1 MAYFLOWER LN,YARMOUTH,
L 3" MAIN PANEL L
MA,02664
PER CODE(S):NEC 2020:705.12(0)(2)(3)(c) TURN RAPIDSHUTDOWNSWITCH TO THE"OFF" SERVICE ENTRANCE INVERTER (EXT) TEL.(506)371-7500
POSITION TO SHUT DOWN —PRODUCTION APN:YARM-000060-000064
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT) METER PROJECT NUMBER:
SHOCK HAZARD IN THE
MAXIMUM AC OPERATING CURRENT:15.83 AMPS ARRAY. II
223R-001 BROW
NOMINAL OPERATING AC VOLTAGE: 240 VAC DESIGNER: (415)580-6920 ex3
LABEL LOCATION: 1 MAYFLOWER LN, YARMOUTH, MA, 02664 AMANSONI
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF l
INTERCONNECTION.
PER CODE(S):NEC 2020:690.54 LABEL LOCATION: SHEET
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 11/16/2022 PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0
C
Tompab h/tlon 4.0 8]