HomeMy WebLinkAboutReview Checklist 7 TOWN OF YARMOUTH % C-' .r / L' � Ijl , 2cti� SEWAGE PLAN REVIEW CHECKLIST /v Location: A.M. Lot 7-'>(, Zone of Contribution: In (yOut_ Acreage Commercial: Residential: Street ! A'.z ,< t_ 1; Village: Floor Plan: l_, - #Bedroom • i I Owner: ` ' ; /" •c" i '; / ,J Installer: b <=2C c,, ,;s41;,.-\ Address: Phone: -,; - y j 7 - c 4 c 3 Phone: Builder: Engineer: ( ; >j ;, a i5 Address: Phone: S L s 3)D ceisp _ '/ Phone: N/A YES NO 1.Required#of copies received 2. Date of soils exam and percolation test not older than 2 years V 3. 4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: / 5. Water line 10 ft from septic components Var.: ✓ 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: i' 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: v 9. Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: _ �✓ 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper,gas baffle on outlet tee / 20. Sewage is under 10,000 gpd for parcel v 21.No garbage disposal V 22. System adequately sized for its intended use ;/ 23. Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size v'" 28. Septic tank/pump chamber to be factory waterproofed ., 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: .,/ 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature .;/ 33.H-20 loading is subject to vehicular traffic,groundwater 1/ 34. Title V Application and permit fee, installer signature 35. Foundation footing min.2 feet above adjusted ground water for new house v 36. Deed Restriction required max. #bedrooms: max. flow:3,2 . gpd v/ 37. Check area lots for groundwater/Label groundwater-in-Ass,ssor's Map L./ Plan reviewed by: 7 C9. , c � _ 6/03/O3