HomeMy WebLinkAboutBLDE-23-003263 Commonwealth of Official Use Only
(fL `1\ Massachusetts Permit No. BLDE-23-003263
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:12/12/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 89 WASHINGTON AVE
Owner or Tenant THACHER LAZZARI Telephone No.
Owner's Address 89 WASHINGTON AVE,WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(28 Panels 9.94 KW-DC)(NO ESS)
Completion of the.following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number _ Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER: I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) ❑ owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
Cap � � � �
Commonwealth o/Maiiacfiueelti �Official Use Only
p., [��
I i �\7 Permit No. 2 lcaJ_3'Z 3
�epar/menl o�Jire Jerl/icei
Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS 'Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICLY1-N' V E D
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR (1�-
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 11/21/2022 s I
City or Town of: Yarmouth MA 02673 To the Inspector of Wirest 2022
By this application the undersigned gives notice of his or her intention to perform the electrical work describe belo
Location(Street&Number)89 WASHINGTON AVE, BUILDING DEPARTMENT
Owner or Tenant THACHER LAZZARI Telephone. o. -
Owner's Address 89 WASHINGTON AVE, Yarmouth MA 02673
Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters
New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of an interconnected PV system including 28 panels at 9.94 Kw DC NO ESS
Completion of the following table may be waived by the Inspector of Wires.
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ ivo.of-Emergency mergence Lighting
grnd. grad. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zone.
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number_ Tons KW No.of Self-Contained
Totals: _..._ ' Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection _
No.of Dryers Heating Appliances KW 'e-curio vstems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
a Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.Hydromassa
g No.of Devices or Equivalent
OTHER:28 Roof Mounted Solar
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $13,568.00 (When required by municipal policy.)
Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of pedury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 4316 Al
Licensee: Nathan Ashe Signature LIC.NO.: 21136 A
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.;978 5943519
Address: 695 Myles Standish Blvd.Taunton. MA 02780 Alt.Tel.No.:978 594-3519
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
SITE PLAN-SCALE=1116"=1'
°L WASHINGTON AVE
-- rn
M
Pt
Pt
(E)RESIDENCE
e
1 BINV PM O
re
1111.1 =MINIM', ...
-- ------
MIMI
-- ----- (N)ARRAY AR-01
(N)ARRAY AR-02
F d
sunrun
#180120
wrcr<0
FM
CUSTOMER RESIDENCE:
THACHER LAZZARI
89 WASHINGTON AVE,
YARMOUTH,MA.02673
ARRAY TRUE MAG PV AREA TEL(901)249.3807
p APN.YARM-000063-000059
\---_______
PITCH AZIM AZIM (SOFT)
AR-01 30° 183° 197° - 353 PROJECT NUMBER:
223R-089LAZZ
_
AR-02 25° 183° 197° 196.1
pi -- DESIGNER: (415)SB08920 ex3
-� NIKESH CHAUHAN
Pt _.__________-- --______j
�� vi SHEET
Pl
SITE PLAN
REV A 11/17/2022
PAGE PV-2.0
rarrOda w +0 rw
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait MAXMAX DISTRIBUTED LOAD:3 PSF
Span Spacing OC Spacing Overhang OC Spacing Overhang SNOW LOAD:30 PSF
11'- RL UNIVERSAL,
SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10" 18" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 3'-0" 1'-6" STAGGERED 140 MPH 3-SEC GUST.
-..... S.S.LAG SCREW
AR-02 COMP SHINGLE-RLU 1-Story 2X8 RAFTERS 18'- 16" RL UNIVERSAL.SPEEDSEAL TRACK ON 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 5/16" 2.5"MIN EMBEDMENT
11" COMP,SEE DETAIL SNR-DC-00436
D1-AR-01-SCALE:3/16"=1'-0" 40-8"
AZIM:183' 1'-10"{— 23,_3" } 5,_11"— 11'_7„— ,—}1_1"
PITCH:30°
1,5"
—6'TYP-
O
6'-10" ❑ ❑ 0 0 ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑
10'-4"
n n ® 9 0 0 ❑ ❑ ❑,
6'-6" h '1 n n _-_ n n— --.-
I
3'
t 4 --__ - - 13'5" #.__ ------ 29,_1„ _. _ ,
D2-AR-02-SCALE:3/16"•1'-0"
AZIM:183° {---4'-7" sunrun
PITCH:25° 1'-10"
4 C INSTALLERS SHALL NOTIFY ENGINEER OF
{-5'4"TYP—' ANY POTENTIAL STRUCTURAL ISSUES
OBSERVED PRIOR TO PROCEEDING WI
STRUCT 4 c INSTALLATION. #180120
ONL `1N or.Mq 0 ❑ 0 E IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" eos•nessr.nasN e�w.uuerw.w.onao_,.0
ay,E➢' ss9rBOUNDARY REGION OF ANY ROOF PLANE o"or•o
yG EDGES(EXCEPT VALLEYS),THEN `'"0
o� VINCENT n,
8 MWUMVANEZA w ATTACHMENTS NEED TO BE ADDED AND CUSTOMER RESIDENCE:
CIVIL 0 0 0 OVERHANG REDUCED WITHIN THE 12" THACHER I A77ARI
o : Speed.11/172022 BOUNDARY REGION ONLY AS FOLLOWS: 89 WASHINGTON AVE,
•;I���EPfG\��� 1T-3" ALLOWABLE ATTACHMENT SPACING YARMOUTH.MA,02673
oNe�cN INDICATED ON PLANS TO BE REDUCED BY
0 ❑ 0 Cl 50 A TEL.(904)249-3807
"ALLOWABLE OVERHANG INDICATED ON
PLANS TO BE 1/5TH OF ALLOWABLE APN:YARM-000063-000059
ATTACHMENT SPACING INDICATED ON PLANS. PROJECT NUMBER:
223R-089LAZZ
❑ a Cl DESIGNER: (415)580.6920 ex3
NIKESH CHAUHAN
_4 ❑ n n__-_. SHEET
LAYOUT
3-2,
I REV:A 11/17/2022
SEE SITE PLAN FOR NORTH ARROW 1'-11"- PAGE PV-3.0
rempde_,e w"_..0.86
f •
N•
120/240 VAC NOTE:TOTAL PV BACKFEED=40A
SINGLE PHASE USED FOR INTERCONNECTION
SERVICE CALCULATIONS
< ® METER M:
EVERSOURCE 1936780
UTILITY
GRID I
1 EXISTING
/ 200A MAIN
BREAKER
I
EXISTING (N)MA SMART
< (N)LOCKABLE UTILITY SOLAREDGE TECHNOLOGIES:
�-, MAIN MAIN BLADE TYPE SE7600H-USSN
FACILITY — PANEL REVENUE
AC DISCONNECT METER 7600 WATT INVERTER JUNCTION BOX PV MODULES
LOADS 3 T 9 (1 OR EQUIVALENT n LONGI GREEN ENERGY TECHNOLOGY
V _-1 0 — __ xV + / CO LTD:LR4-S0HPB-355M
o�ro —a�— M •--.� — —� / (28)MODULES
OPTIMIZERS WIRED IN:
( I (1)SERIES OF(14)OPTIMIZERS
(N)40A .I—a SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT ' (1)SERIES OF(14)OPTIMIZERS
PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R.60A,2P uTILITY SIDE OF CIRCUIT COMPLIANT S440
OF BUSBAR 120240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
Y CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE • NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHWTHWN-2 S u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
*180120
•06 MIAS STAMM lw,iMIMO.M&02116113,
6we0
FAA 0
MODULE CHARACTERISTICS CUSTOMER RESIDENCE:
LONGI GREEN ENERGY OPTIMIZER CHARACTERISTICS: THACHER I A77ARI
MIN INPUT VOLTAGE: 8 VDC
TECHNOLOGY CO LTD. 89 WASHINGTON AVE,
MIN LR4-6OHPB-355M: 355 W MAX INPUT VOLTAGE: 60 VDC YARMOUTH,MA,02673
OPEN CIRCUIT VOLTAGE 40.6 V MAX INPUT ISC: 14.5 ADC
MAX POWER VOLTAGE: 34.6 V MAX OUTPUT CURRENT: 15 ADC TEL.(904)249-3807
SHORT CIRCUIT CURRENT. 11,25 A APN:YARM-000063-000059
PROJECT NUMBER:
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 9940 W 223R-089LAZZ
SYSTEM OPEN CIRCUIT VOLTAGE: 14 V
SYSTEM OPERATING VOLTAGE: 400 V DESIGNER: (415)580-6920 ex3
MAX ALLOWABLE DC VOLTAGE: 460 V
NIKESH CHAUHAN
SYSTEM OPERATING CURRENT: 24.85 A
SHEET
SYSTEM SHORT CIRCUIT CURRENT. 30 A ELECTRICAL
REV:A 11/17/2022
PAGE PV-4.0
•-•-I."-*=S_4.Oee
ZI\WARNING INVERTER 1 NOTES AND SPECIFICATIONS.
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF TIE NEC 2020 ARTICLE
ELECTRIC�.I H(!(.N HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECT/ON 690.OR
_ IF REQUESTED BY THE LOCAL AHJ
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT
PER CODE(S)NEC 2020.690.53 INVOLVED.
LABEL LOCATION. •SIGNS AND LABELS SHALL COMPLY WITH ANSI 15 3 5 4-2 01 1,PRODUCT SAFETY
INVERTER(S),AC/DC OSCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE) •DO NOT COVER EXISTING MANUFACTURER LABELS
PER CODE(S),NEC 2020 69013(B)
WARNING:PHOTOVOLTAIC
WARNING POWER SOURCE
LABEL LOCATION
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. -- - -
Ill
AND PV SOLAR ELECTRIC PER COMM:NEC 2020 690.31(D)(2),IFC 2012.
SYSTEM 605.11.1.4 A U T I N
LABEL LOCATION
UTILITY SERVICE METER AND MAIN
SERVICE PANEL ■
PER CODE(S).NEC 2020.705.12(C)
! WARNING
ID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTIONOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS
OVERCURRENT DEVICE LABEL LOCATION
/ INSTALLED WITHIN 3'OF RAPID SHUT DOWN
AENCATION SWITCH 0 PER CODE(S)NEC 2020 690 58(C)121.IFC ADJ CNT TO PV s u n r u n
OCPD(EIF APPLICABLE) RAND ESS 2012.605 11 1 IFC 2078 120453 I' SOLAR PANELS ON
PER CODEISI-NEC 2020 1 ROOF
705 1218X3N2) —
AWARNING"". SOLAR PV SYSTEM EQUIPPED #180120
s swots(BLW,TAUMrw.Mk 0770.73.11
PHOTOVOLTAIC
OMBINERPANEL EM WITH RAPID SHUTDOWN MAIN PANEL (INT)- FAA
DO NOT ADD LOADS I CUSTOMER RESIDENCE:
11 THACHER I A77ARI
LABEL LOCATION 89 WASHINGTON AVE,
PHOTOVOLTAIC AC COMBINER(IF
I -INVERTER (EXT) YARMOUTH,MA,02673
APPLICABLE) 3" TURN RAPID SHUTDOWN
PER CODE(S).NEC 2020 705.1210)(2)13)k)
SWITCH TO THE"OFF" —PRODUCTION METER TEL,(904)249.3807
POSRION TO SHUT DOWN APN:YARM-000083-000059
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE —AC DISCONNECT PROJECT NUMBER'
SHOCK HAZARD IN THE 223R 089LAZZ MAXIMUM AC OPERATING CURRENT:32.00AMPS
NOMINAL OPERATING AC VOLTAGE: 240 VAC ARRAY. ---SERVICE ENTRANCE
DESIGNER: (415)580-6920 ex3
LABEL LOCATION J89 WASHINGTON AVE, YARMOUTH, MA, 02673 NIKESHCHAUHAN
AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION '}LABEL --_- SHEET
PER CODE(S).NEC 2020.590.54 ON OR NOMORE THAT I M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIG NAG E
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV A 11/172022
PER CODE(S).NEC 2020:690.56(C)
PAGE PV-5.0
rempltl.,flA,4oes
I.
I.
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE N DESCRIPTION 2NISERVICE ENTRANCE •SYSTEM SIZE:9940W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH
PV-1.0 COVER SHEET Sit •MODULES:(28)LONGI GREEN ENERGY TECHNOLOGY CO ED.CMR 780(2015 IRCABC/IEBC),MUNICIPAL CODE,AND ALL MANUFACTURERS'
LTD:LR4-6OHPB-355M LISTINGS AND INSTALLATION INSTRUCTIONS.
PV-2.0 SITE PLAN MP MAIN PANEL •INVERTERS:(1)SOLAREDGE •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
PV-3.0 LAYOUT TECHNOLOGIES:SE7600H-USSN
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
PV-4 0 ELECTRICAL SP SUB-PANEL COMP,SEE DETAIL SNR-DC-00436 •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-5 0 SIGNAGE —
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
0 SUNRUN METER •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM DEDICATED PV METER •SNAPNRACK RACKING SYSTEMS.IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
AC AC DISCONNECT(S)
O •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
IDC I DC DISCONNECT(S) •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
•11.25 AMPS MODULE SHORT CIRCUIT CURRENT.
CB IQ COMBINER BOX •17.57 AMPS DERATED SHORT CIRCUIT CURRENT[890.8(A)8 690.8(B)].
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)
ABBREVIATIONS I- 1 INTERIOR EQUIPMENT (2).CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
L J SHOWN AS DASHED A AMPERE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC A FAULT R4TT $u n r u n
AFC ARC FAULT CIRCUIT PrtERUPTER ;j CHIMNEY
KW AZIMUTH
COMP COMPOSITION
OC pRECTCURRENT ATTIC VENT
#180120
(RI EXISTING FLUSH ATTIC VENT VICINITY MAP
w NMI ST.1.1 SLw.TA„NTON M..oT,a»,
ESS ENERGY STORAGE SYSTEM P PI V N COPlINE
FAA
NUT EXTERIOR METAL PIPE VENT..
CUSTOMER RESIDENCE
INr INTERIOR .- T-VENT - THACHER I A77ARI
MSP MAIN SERVICE PANEL
89 WASHINGTON AVE,
a (1-1 NEW SATELLITE DISH YARMOUTH,MA,02673
NTS NOT TO SCALE
TEL.(904)249.3807
OC ON CENTER FIRE SETBACKS r,,,y ,�;r.. �rt•-+ ' APN:YARM•000063-000059
PROJECT NUMBER:
PREFAB PRE-FABRICATED
MO POUNDS PER SOUARE FOOT _7.1 HARDSCAPE • - 223R-089LAZZ
PV PHOTOVOLTAIC
RSD RAPIO SNUTDOVR1 DEVICE —PL— PROPERTY LINE - DESIGNER (415)580$920 ex3
r TMNSFORMERlE85 SOLAR MODUSCALE:LES 76 NIKESH CHAUHAN
NTS :-
SHEET
IVY TYPICAL MNI= •. - . - -" REV NAME DATE COMMENTS COVER SHEET
V VOLTS
w WATTS 1111111111111. • REV:A 11/17/2022
AN LANDSCAPE - SNR MOUNT
tYANMI5 .I E- PAGE PV-1.0
NOR PORTRAIT SNR MOUNT&SKIRT ,.. f.,.,.
r npsa_.anal_4oss