Loading...
HomeMy WebLinkAboutEngineer PlanII LOCATION MAP NOT TO SCALE II NOTES: 1. PLAN REFERENCES: 1.1. PLAN ENTITLED 'RE -SUBDIVISION PLAN OF BAY RIDGE IN YARMOUTH" RECORDED IN PLAN BOOK 143, PAGE 89. 2. TOPOGRAPHIC AND DETAIL INFORMATION SHOWN HEREON IS BASED UPON AN ON THE GROUND SURVEY PERFORMED BY MERRILL ENGINEER'S AND LAND SURVEYORS DURING SEPTEMBER OF 2023. 3. ALL ELEVATIONS ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988. 4. SUBJECT SITE IS IN THE RESIDENTIAL "R-40" DISTRICT AS DEPICTED ON THE TOWN OF YARMOUTH ZONING MAP. 5. EXISTING UTILITIES, WHERE SHOWN, HAVE BEEN COMPILED BASED ON OBSERVED ABOVE GROUND EVIDENCE AND AVAILABLE RECORD PLANS AND ARE M BE CONSIDERED APPROXIMATE. MERRILL ENGINEERS AND LAND SURVEYORS DOES NOT GUARANTEE THE LOCATION OF THE UNDERGROUND UTILITIES SHOWN OR THAT ALL EXISTING UTILITIES AND/OR SUBSURFACE STRUCTURES ARE SHOWN. ENVIRONMENTAL NOTES: 1. SITE IS NOT WITHIN AN A.C.E.C. (AREA OF CRITICAL ENVIRONMENTAL CONCERN). 2. SITE IS NOT WITHIN AN AREA OF ESTIMATED HABITAT OF RARE WILDLIFE PER NHESP MAP "ESTIMATED HABITATS OF RARE WILDLIFE" FOR USE WITH THE MA WETLANDS PROTECTION ACT REGULATIONS (310 CMR 10)." 3. SITE DOES NOT CONTAIN A CERTIFIED VERNAL POOL PER NHESP MAP "CERTIFIED VERNAL POOLS! 4. SITE IS NOT WITHIN A PRIORITY HABITAT PER NHESP MAP "PRIORITY HABITATS OF RARE SPECIES" FOR SPECIES UNDER THE MASSACHUSETTS ENDANGERED SPECIES ACT, REGULATIONS (321 CMR10). 5. SITE IS NOT LOCATED WITHIN A STATE APPROVED ZONE 11 GROUND WATER RECHARGE PROTECTION AREA. LEGEND ❑ BP BEAN POLE FOUND 13 CB/DH CONCRETE BOUND W/DRILL HOLE FOUND 0 CH8 COUNTY HIGHWAY BOUND FOUND U IP IRON PIPE FOUND -6 HID FIRE HYDRANT 0 POST WOOD POST Q SHRUB SHRUB DECIDUOUS TREE CONIFEROUS TREE 0 UP UTILITY POLE - 0-0-0- POST AND RAIL FENCE --0 -0- STOCKADE FENCE ----34---- - - - - -- CONTOUR LINE G GAS UNE OHW OVERHEAD WIRES W WATER MAIN s PARCEL ID: 137-64.1 #311 MAYFAIR ROAD, YARMOUTH NORMAN HASSAN AND JACQUELINE GUNDBERG 119 LONGWOOD AVENUE PROVIDENCE, RI 02908 DEED BOOK 35295 PAGE 209 LOT 37: PLAN BOOK 143 PAGE 89 FLOOD NOTE: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS LOCATED IN ZONE X OF THE FLOOD INSURANCE RATE MAP, AS SHOWN ON COMMUNITY MAP No. 25001 C0583J, WHICH BEARS AN EFFECTIVE DATE OF JULY 16, 2014, AND IS NOT IN A SPECIAL FLOOD HAZARD AREA. ZONING REQUIREMENTS RESIDENTIAL 'R-40" DISTRICT REQUIRED PROPOSED BUILDING COVERAGE <25% 15.7yf MINIMUM YARDS: FRONT YARD 30 FEET 31 FEET SIDE YARD 20 FEET 21 FEET REAR YARD 20 FEET 49 FEET ZONING NOTE: REFER TO THE TOWN OF YARMOUTH ZONING BYLAW FOR EXCEPTIONS AND ADDITIONAL DETAILS. CHB TOP FOUND. = 38.5f 25.Ot MARKING TAPE OVER SYSTEM COMPONENTS EL=28.Ot \7/ `- - -- -PROPOSED - �-, 4"0 PVC SCH 80 PROPOSED 2-20 GONERS rmuru3=u n-1u u-Dun RISER BROUGHT TO WITHIN PROPOSED 4"0 PVC SCH 40 PERFORATED BROUGHT TO WITHIN 6" OF FINISH GRADE INSPECTION PORT. PROVIDE A THREADED CAP. 6" OF FINISH GRADE PORT TO BE ENCLOSED IN A RISER BROUGHT 15' (5' W/ BARRIER) 26.0t FINISH GRADE TO FINISH GRADE I-- - - - - - - - - - - (BREAKOUT EL=22.0) - - -!I CL I MAX. COVER= 36" EL=25.0f(MAX) VENT W/ En I En PROPOSED INLET TEE MN. COVER= 12 12"MIN EL=23.0t(MIN) CHARCOAL '� I O - PROPOSED 4 _ LEVEL FIRST//�\/.(�\�l//�\ TWO FEET - - . -- - �,� I FILTER 3_ s" z" PVC SCH 40 PIPE 4 „ � PYC SC 1 _ 11 MAX 1 ME 3=.uL WHIN 3" S=0.Q1 MIN H-40 FILTER FABRIC TOP EL. 22.Q EL.23.25 _ ` I EL 23.0 S 0_O 1 MIN L1. 2 .5 w,:�;,.�I , r•s+• L. 21.13 o O'er ... " .. 1'-10" .. - 46 EL. CRUSHE 21.33 . ` „ 12 '• 10' MIN INSTALL MA-DEP STONE '� BOT STONE EL. 19.13 4'-0" 4'-0" 4'-0" TO BLDG (TYP) APPROVED EFFLUENT REIN. CONC. DIST. BOX 12"-3/4" TO 1 1 2" FILTER (ZABEL OR 19"X12"X12" INSIDE (M!N}: APPROVED EQUAL) 6" MECHANICALLY COMPACTED (H-10 LOADING) WASHED STONE 12.0 5 1 20' MIN CRUSHED STONE , TO SOIL ABSORPTION SYSTEM (TYP) PROPOSED _ 3 (481 CONCRETE LEACHING CHAMBERS I z 1500 GAL (MIN.) PRECAST CONCRETE 12" STONE BELOW CHAMBERS 4 S ONE ON SIDES ILO TANK W/2 PVC SCH 40 TEES AND 2' STONE ON END (MONOLITHICALLY POURED) TOTAL EFFECTIVE LEACHING AREA = 281 X 12.0 X 2.0'D i 0(SEE) SUBSURFACE LIMIT DF EXC OIL LOGS) T SEWAGE DISPOSAL SYSTEM- (NOT TO SCALE) GROUND WATER EL <14.0 - -I_ NO MOTTLES 11 TH 23-71 #2 SEPTIC DESIGN (NOT DESIGNED FOR A GARBAGE GRINDER) 1. DESIGN DAILY FLOW: 3 BR. x 110 GPD = 330 GPD *USE FOR DESIGN*. 2. SEPTIC TANK: 330 GPD x 2 = 660 GAL (USE 1,500 GAL SEPTIC TANK) 3. LEACHING FIELD: P.R. = 5 MIN/IN, CLASS I , E.LR. = 0.74 GPD/SF TITLE V : (NOT DESIGNED FOR GARBAGE GRINDER) REQUIRED AREA: 330 GPD/0.74 GPD/SF = 446 SF (MIN) USE: 3-48' LEACHING CHAMBERS IN 12'W x 281 x 2.0' DEEP STONE PROPOSED AREA: 28'x12' = 336 S.F., PLUS 2.0' x (28+28'+12'+12')=160 S.F. TOTAL=496 S.F. CAPACITY: 496 S.F. x 0.74 GPD/S.F. = 367 GPD(D.D.F.) > 330 GPD MIN 4. EXCAVATE ALL MATERIAL 5' AROUND SYSTEM TO C LAYER (SEE SOIL LOGS). REPLACE WITH CLEAN COARSE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255 TO TOP OF S.A.S. (SEE PROFILE). EXCAVATION MUST BE INSPECTED BY THE TOWN AND MERRILL CORPORATION BEFORE SOIL PLACEMENT. 44.7 Toy�yN LINE -- PROPOSED ELECTRIC (LOCATION T.B.D. BY ""�-•� UTLTTY COMPANY) �j �^� \ CON o \ R=43.77 CB/bH L4NDCOURT � R`2 1.64 Ilk CBN 1430 �✓� o (NO EASEMENT DOCUMENTS ROUND) +38.5 Gam/ P ." t` `.� - to PARCEL ID:137-65 f { +38.2 n'Y NIF s R N ;� 8P fWD LOT COR 44. STEPHEN P. RODERICK _ - - - - KUEI77U CHANG L.C.C. 208683 r 21' 38.4 \� 38.5+ 45.7 -PROPOSED WATER CONNECTION (LOCATION T.B.D. BY UTILITY COMPANY) PROPOSED GAS CONNECTION (LOCATION T.B.D. BY UTLITY COMPANY) FAVED GARAGE ( 3 SLAB=39.0± PROPOSED 3 _ 2-STORY BP FND LOT LINE BP FND LOT LINE DWELLING 32pF� �1 ` BEtJ^NA!4RK: z, F.F.E.=39.5' I FROI;7 BONNET BOLT INTERIOR PLUMBING TO R; z / T.O.F =38 5 EL=45.57 (NAVD 86) BE ROUTED TO REAR & cn IBSMT=28 5 ELEVATION SET BY { w s PLUMBER u, _ ?,,, y \ PARCEL ID:137-642 I 'ARE - POP. \ ;� ( NMS T. ANGI&AlAVAMCH 1 5 N � � � � CK ao LUARETTA A. LYONS PROPOSED 1,500 `" DEED BOOK: 34681 GALLON SEPTIC TANK N �' I' 1, ; Z PACE: 132 Yr�r'► " 8P fND LOT UNE -15' PROPOSED D-BOX PROPOSED SOIL ABSORPTION SYSTEM (3) FLOW DIFFUSER PRECAST CONCRETE LEACHING CHAMBERS IN TRENCH CONFIGURATION (12 W x 281 x 2'D EFFECTIVE AREA) PARCEL ID:137-66 NIF RICHARD J. FAGAN JR. PAULA FAGAN L.C.C.199943 COPYRIGHT(CD BY MERRILL CORPORATION NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING OR OTHERWISE, WITHOUT THE EXPRESS WRITTEN CONSENT OF MERRILL CORPORATION WITH THE EXCEPTION OF ANY REGULATORY AUTHORITY WHICH MAY REPRODUCE IT IN CONJUNCTION WITH THE PERFORMANCE OF OFFICIAL BUSINESS UNDER ITS JURISDICTION. ANY MODIFICATIONS MADE TO THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF MERRILL CORPORATION SHALL RENDER IT UNUSABLE. VE04 _ _ _4X4' LANDING - IPROPOSED RESERVE AREAL ---22-----1 LOT AREA - 6'1 14,495t-SF - 0.33t ACRES CBIVH S 71'08142" E 81.94' _f PARCEL ID: 137-36 NIF 20 EIDER STREET NOMINEE TRUST DEED BOOK: 30002 PAGE: 8 CHB 1 1 1 •1 .1 ---- Health Department _�i0fTlIt.-.4 Date GENERAL CONSTRUCTION NOTES: 1. THE INSTALLATION OF THE SEPTIC SYSTEM MUST BE PERFORMED BY A LICENSED CONTRACTOR. 2. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL SECURE ALL NECESSARY STATE, MUNICIPAL, AND UTIUTY PERMITS AND VERIFY PROPOSED LOCATION OF UTILITIES WITH UTILITY COMPANIES. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL STANDARDS AND REGULATIONS. 4. CONTRACTOR MUST NOTIFY DIG -SAFE PRIOR TO CONSTRUCTION. EXISTING UTIUTIES, WHERE SHOWN, ARE APPROXIMATE. MERRILL ENGINEERS AND LAND SURVEYORS DOES NOT GUARANTEE THE LOCATION OF THE UNDERGROUND UTILITIES SHOWN OR THAT ALL EXISTING UTILITIES AND/OR SUBSURFACE STRUCTURES ARE SHOWN. 5. CONTRACTOR TO NOTIFY MERRILL ENGINEERS AND LAND SURVEYORS OF ANY INCONSISTENCIES ON THE PLAN. NO CHANGES ARE TO BE MADE IN THE FIELD WITHOUT THE APPROVAL OF THE YARMOUTH BOARD OF HEALTH AND MERRILL ENGINEERS & LAND SURVEYORS. 6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. THE YARMOUTH BOARD OF HEALTH AND MERRILL ENGINEERS AND LAND SURVEYORS TO BE NOTIFIED OF ANY INCONSISTENCIES NOTED IN THE FIELD. 7. ALL YARD WASTE & DEBRIS SHALL BE DISPOSED OF OFF SITE AT AN APPROPRIATE FACILITY. THE YARMOUTH BOARD OF HEALTH & BUILDING INSPECTOR MAY REQUIRE PROOF OF DISPOSAL. 8. ALL AREAS DISTURBED BY CONSTRUCTION AND NOT TO BE PAVED OR OTHERWISE TREATED AS NOTED ON PLAN, SHALL BE GRADED WITH 4" OF SCREENED LOAM AND SEEDED. 9. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE. 10. THE INSTALLER WILL PROVIDE 48 HOURS NOTICE TO THE YARMOUTH BOARD OF HEALTH AND MERRILL ENGINEERS AND LAND SURVEYORS FOR THE FOLLOWING INSPECTIONS: A.) EXCAVATION B.) INSTALLED SYSTEM PRIOR TO BACKFILL 11.THERE WILL BE NO BUOYANT FORCES ACTING ON ANY COMPONENTS OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM. 12.THE CONTRACTOR SHALL ENSURE ALL COMPONENTS OF THE SUBSURFACE SEWAGE DISPOSAL SYSTEM HAVE A MINIMUM OF 10 FT SEPARATION TO WATER SUPPLY LINES. 13.INSTALL RISERS WITH COVERS TO GRADE ON ALL SEPTIC TANK INLET AND OUTLET OPENINGS. 14. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SYSTEM. 15. ELECTRIC, TELEPHONE AND CABLE UTILITIES PER UTILITY COMPANY REQUIREMENTS. 16.MERRILL RECOMMENDS PROPERLY DESIGNED FOUNDATION DRAINS, BY OTHERS, FOR EVERY STRUCTURE WITH A BASEMENT. 17. CONTRACTOR TO CONFIRM GROUNDWATER ELEVATION AT FOUNDATION PRIOR TO CONSTRUCTION. 18. ALL SEPTIC SYSTEM COMPONENTS SHALL BE RATED FOR H-10 LOADING. 19. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT THE GRADING AROUND THE FOUNDATION MEETS THE REQUIREMENT'S OF THE MJ SS. STATE BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE (IRC 2009) SECTION R401.3. THE GRADE SHALL DROP A MINIMUM OF 6" WITHIN 10 FEET OF THE FOUNDATION AS REQUIRED TO ENSURE WATER DRAINS AWAY FROM THE FOUNDATION. ADDITIONALLY, THE MINIMUM DISTANCE FROM FINISH GRADE TO ANY WOOD FRAMING/CONSTRUCTION SHALL MEET THE MINIMUM REQUIREMENTS OF THE MASS. STATE BUILDING CODE AND THE IRC 2009. 20.CONTRACTOR SHALT. OBTAIN STREET OPENING PERMIT FOR PROPOSED CURB CUT ON MAYFAIR ROAD. SOIL LOGS PERFORMED BY: JACK LANDERS-CAULEY, P.E. WITNESSED BY: YARMOUTH BOARD OF HEALTH DATE: AUGUST 3, 2022 T.H. 22-1 T.H. 22-2 EL. 37.5 EL. 37.5 0" TO 4" 0" TO 8" A HORIZON A HORIZON LOAM FILL LOAMY SAND LOAMY SAND 10 YR 3/3 37.2 10 YR 3/2 37.2 4" TO 36" 8" TO 23" B HORIZON B HORIZON LOAMY SAND LOAMY SAND 10 YR 5/6 34.5 10 YR 5/6 34.5 36" TO 120" 23" TO 120" C LAYER C LAYER MEDIUM/ PERC MEDIUM/ FINE SAND ®4B_gg" COARSE SAND 10 YR 7/4 R-5 2.5 YR 6/3 D=10' NO WATER ENCOUNTERE NO MOTTLES 27.5 1 127.5 D=10' NO WATER NCOUNTERED NO MOIRES SOIL LOGS PERFORMED BY: LARRY CARREIRO (MERRILL ENGINEERING) WITNESSED BY: YARMOUTH BOARD OF HEALTH DATE: DECEMBER 13, 2023 T.N. # 1 (23-71) T.H. #2 (23-71) EL. 26.0 EL. 24.0 0" TO 11" 0" TO 11 " A HORIZON A HORIZON LOAM /FILL LOAMY SAND LOAMY SAND 10 YR 3/3 25.1 10 YR 3/2 23.1 11 " TO 48" 11 " TO 48" B HORIZON B HORIZON LOAMY SAND SAND 10 YR 5/6 22.0 0LOAMY 5/6 20.0 48" TO 120" 48" TO 120" C LAYER C LAYER MEDIUM MEDIUM SAND SAND 2.5Y 6/4 2.5 YR 6/3 16.0 1 114.0 D=10' I D=10' NO WATER I NO WATER merrillinc.com REVISIONS 1, I I I i, I 1 1 HOUSE BOX/SITE ADJUSTMENTS 1/17/2 1 NEW PERC TESTS/E RATIONS 12/14/ DRANAN BY KNH DES ISNEO 81' KW CHECKED BY TS SCALE: 1"=20' STAMP: ao-,A or &1414 DEANA o BI(' UMITRI No. 49075 N a Is , . L ZN OF q M TIMOTHY M. N �a SANTOS �s CIVIL -� N0.45070 u' .0 9�G�STEp'�� �ss��Pi 4L `NC3� l P a M e ni Engineers and Land Surveyors 427 Columbia Road Hanover, MA 02339 781-826-9200 40 Court Street, Ste 2A Plymouth, MA 02360 508-746-6060 Marine Division: 26 Union Street Plymouth, MA 02360 508-746-6060 448 N. Falmouth Hwy, Unit A North Falmouth, MA 02556 508-563-2183 PROJECTI* 23-382 PROJECT: PLOT PLAN #311 MAYFAIR ROAD PARCEL ID: 137-64.1 YARMOUTH, MASSACHUSETTS CLIENT: REpurpose Construction, LLC PO BOX 334 BUZZARDS•BAY, MA 02532 DRAWING PATH: H:\23-382\DESIGN\23-382 SITE PLAN.DWG DATE: DECEMBER 7, 2023 PLAN OF PROPOSED DWELLING & PROPOSED SEWAGE DISPOSAL SYSTEM SHEET 1 of 1 1ilw#1 Capwdim