Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out ----Acreage � / Commercial: Residential: -- ' Street: / 5 /V u4 1, Village: S. Y . Floor Plan: L #Bedrooms: (-/ Owner: Do V.eh pod- Gom04,..;o f Installer: 30.,rio i; Address: ,2 w LME. .,\St. Phone: uK- yl,D -„96 63 Phone: Builder: Engineer: J , Q2�, ��.1 £/WU G Address: Phone: c . S - 6C/ l Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years c/ 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1/ 9. Leaching minimum 100 ft from wetlands Var.: V 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: `/ 11.Tank/leaching minimum 10 ft from property line Var.: V 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: ✓ 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: t/ 15. System not in top or subsoil(A,B horizons)or 5' removal ✓� 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '''4"preferred v 18. System meets breakout requirements PVC liner: Wall: V 19. Specified tee sizes are proper,gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal ✓ 22. System adequately sized for its intended use N/ 23. Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade t/ 25. Inspection port on plastic chambers/leach field t/ 26.Electrical permit for pump chamber/Separate meter for duplexes 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed / v 29.Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber ,j 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic,groundwater 34. Title V Application and permit fee,installer signature ✓ 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwate • is Map Plan reviewed by: 7,2 6/• c9c f 6/03/03